potentialpaper

Rethinking Visual Attribution for Chest X-ray Reasoning in Large Vision Language Models

Update NeurIPS 2026 submission YoNjeiTDbj: 4 notes

@openreview[bot] · 2026-11-24 15:52 UTC · 6d85db6387ca ·

Evidence

reviews/openreview/yonjeitdbj/notes/7qr5ihsefn.json modified

+++ b/reviews/openreview/yonjeitdbj/notes/7qr5ihsefn.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair saN2",
"content": {
- "metareview": "(a) Summary: The paper takes on a trust problem in medical vision language models, namely that their answers are often not actually grounded in the right visual evidence. It offers two contributions. First, MedGround-Bench, a causally validated CXR-VQA attribution benchmark that uses counterfactual image editing to check whether a prediction really depends on the clinically relevant region, and it uses this to show that 11 existing attribution methods often fail to point at the evidence driving the decision. Second, MedFocus, a concept-based causal attribution method that measures how much each anatomical region influences the output through targeted interventions, and returns pixel-, concept-, and token-level attributions with a single forward pass per concept. Experiments span three CXR datasets, several LVLMs, and both direct-answer and reasoning modes.\n\n(b) Main strengths: Reviewers agree the problem is important and closely tied to clinical trust. Moving from correlation-based evaluation to a causal one built on counterfactual editing is seen as a solid methodological step. MedFocus is efficient because it relies on a single forward pass, which matters for real deployment, and attributing the reasoning trace at the token and concept level is a novel and interesting direction. The experimental setup is broad and well controlled, covering three datasets, multiple models, and a multi-step filtering pipeline that isolates whether the prediction is truly driven by the relevant region.\n\n(c) Main weaknesses: A few concerns are shared across reviewers. The foreground/background split is oversimplified and may not handle diagnoses that need evidence from several regions or global cues such as cardiothoracic ratio, bilateral symmetry, or diffuse bilateral disease, and the causal filter may silently drop these cases. The evaluation also looks unfair to the baselines, since all pixel-level saliency maps are turned into boxes with a fixed 90th-percentile threshold, while MedFocus outputs a concept box directly, so the comparison is not on equal footing. The zero-masking intervention can add boundary artifacts and out-of-distribution patterns, so the model may react to image damage rather than to missing evidence, and gentler edits such as healthy-tissue inpainting or cross-disease replacement are not compared. Reviewers also flag a human-centric bias since faithfulness is anchored to human annotations, a possible finding-versus-anatomy mismatch in the IoU measurement, limited in-domain LVLM coverage, and that the binary VQA setup does not capture the full range of clinical reasoning.\n\n(d) First, an evaluation-fairness check that shows whether MedFocus stays ahead when the baselines are allowed validation-tuned adaptive thresholds instead of a fixed one. Second, a comparison across intervention types (zero-masking versus healthy-tissue inpainting versus cross-disease replacement) to rule out results that are driven by masking artifacts rather than true removal of evidence. Third, some handling of the multi-region and global-cue cases, at least an analysis of how often they are excluded by the filter, plus per-region support and metrics. Clear answers on evaluation fairness and the intervention design would matter most."
+ "metareview": "(a) Summary: The paper takes on a trust problem in medical vision language models, namely that their answers are often not actually grounded in the right visual evidence. It offers two contributions. First, MedGround-Bench, a causally validated CXR-VQA attribution benchmark that uses counterfactual image editing to check whether a prediction really depends on the clinically relevant region, and it uses this to show that 11 existing attribution methods often fail to point at the evidence driving the decision. Second, MedFocus, a concept-based causal attribution method that measures how much each anatomical region influences the output through targeted interventions, and returns pixel-, concept-, and token-level attributions with a single forward pass per concept. Experiments span three CXR datasets, several LVLMs, and both direct-answer and reasoning modes.\n\n(b) Main strengths: Reviewers agree the problem is important and closely tied to clinical trust. Moving from correlation-based evaluation to a causal one built on counterfactual editing is seen as a solid methodological step. MedFocus is efficient because it relies on a single forward pass, which matters for real deployment, and attributing the reasoning trace at the token and concept level is a novel and interesting direction. The experimental setup is broad and well controlled, covering three datasets, multiple models, and a multi-step filtering pipeline that isolates whether the prediction is truly driven by the relevant region.\n\n(c) Main weaknesses: A few concerns are shared across reviewers. The foreground/background split is oversimplified and may not handle diagnoses that need evidence from several regions or global cues such as cardiothoracic ratio, bilateral symmetry, or diffuse bilateral disease, and the causal filter may silently drop these cases. The evaluation also looks unfair to the baselines, since all pixel-level saliency maps are turned into boxes with a fixed 90th-percentile threshold, while MedFocus outputs a concept box directly, so the comparison is not on equal footing. The zero-masking intervention can add boundary artifacts and out-of-distribution patterns, so the model may react to image damage rather than to missing evidence, and gentler edits such as healthy-tissue inpainting or cross-disease replacement are not compared. Reviewers also flag a human-centric bias since faithfulness is anchored to human annotations, a possible finding-versus-anatomy mismatch in the IoU measurement, limited in-domain LVLM coverage, and that the binary VQA setup does not capture the full range of clinical reasoning.\n\n(d) First, an evaluation-fairness check that shows whether MedFocus stays ahead when the baselines are allowed validation-tuned adaptive thresholds instead of a fixed one. Second, a comparison across intervention types (zero-masking versus healthy-tissue inpainting versus cross-disease replacement) to rule out results that are driven by masking artifacts rather than true removal of evidence. Third, some handling of the multi-region and global-cue cases, at least an analysis of how often they are excluded by the filter, plus per-region support and metrics. Clear answers on evaluation fairness and the intervention design would matter most.",
+ "final_justification": "The paper makes a clear and clinically motivated contribution, and the benchmark and method are technically sound. All reviewers voted Accept or Weak Accept, and maintained their ratings after the rebuttal, which addressed the substantive concerns. The two remaining points (evaluation fairness under adaptive thresholds, and intervention design beyond zero-masking) are refinements to the evaluation rather than challenges to the core claims. I therefore recommend acceptance, and ask the authors to include these additions, along with the promised adaptive-threshold fairness check and intervention-type comparison, in the camera-ready."
},
"createdAt": "2026-07-19T11:37:42.296Z",
- "modifiedAt": "2026-11-18T15:21:32.205Z",
+ "modifiedAt": "2026-11-19T05:00:56.352Z",
"url": "https://openreview.net/forum?id=YoNjeiTDbj&noteId=7qr5IHsEFn",
"license": "CC-BY-4.0"
}

reviews/openreview/yonjeitdbj/notes/clej64kk82.json added

+++ b/reviews/openreview/yonjeitdbj/notes/clej64kk82.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "CleJ64KK82",
+ "replyTo": "u0U4Ynj8ZW",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer cSVb",
+ "content": {
+ "comment": "Thank you for the detailed rebuttal. The addition of another medical LVLM has improved the paper's experimental strength, and exposing that models fail even with trivially correlated anatomical grounding indeed demonstrates the method's effectiveness. This, along with the additional experimental results, resolves the majority of my concerns. I still think the method has an inductive advantage in that it builds on concepts rather than pixel-based methods, regardless of the dataset used. I would also note that the concepts used are limited to anatomical regions and do not capture the finer clinical descriptors that a radiologist would use to ground pathologies in an image."
+ },
+ "createdAt": "2026-08-03T22:21:09.683Z",
+ "modifiedAt": "2026-11-19T16:58:42.361Z",
+ "url": "https://openreview.net/forum?id=YoNjeiTDbj&noteId=CleJ64KK82",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/yonjeitdbj/notes/gox8cxunig.json added

+++ b/reviews/openreview/yonjeitdbj/notes/gox8cxunig.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "gOX8cxUNig",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Dear Reviewers and Area Chair,\n\nThank you for your thorough and insightful reviews. We are encouraged by your positive feedback about the methodological novelty (Area Chair `saN2`, Reviewers `qr8X`, `cSVb`) and experimental breadth (Area Chair `saN2`, Reviewers `qr8X`, `cSVb`) on this clinically important problem (Area Chair `saN2`, Reviewer `jfsJ`). Following the comments and suggestions, we have revised our paper to address all concerns raised in the review process. Below, we summarize how our revisions address the main concerns mentioned in the meta review:\n- **Handling of multi-region cues**: We clarified that our benchmark construction and method implementation are not restricted to one-region attribution. The original human annotation for foreground/background editing in the construction of MedGround-Bench may inherently include multiple pathological changes, and our method MedFocus supports the identification of region unions for model attribution. We presented further analysis to show that multi-region-based diagnosis is well-represented in MedGround-Bench, and that MedFocus provides better attribution than the baselines on multi-region cases such as bilateral lung regions. Moreover, we provided per-region analysis to show the consistent advantage of MedFocus across different anatomical regions.\n- **Evaluation fairness**: We applied a single fixed threshold to convert all saliency maps to bounding boxes, ensuring a uniform evaluation protocol across baselines. Following the suggestion, we provided additional results with per-method tuned threshold values, showing that the baseline methods achieve higher IoU/F1 at the cost of lower precision, but remain inferior to MedFocus across metrics. To address the concern that saliency-map-based attribution methods may be disadvantaged on questions with coarse-grained annotations under the IoU metric, we highlighted the precision scores already reported in our paper and provided a detailed per-model breakdown, showing that MedFocus achieves the highest average precision across models.\n- **Intervention design**: In addition to the zero-masking intervention used in MedFocus, we discussed the \"healthy-tissue inpainting\" alternative in our original paper. As suggested, we included an additional comparison to the \"cross-disease replacement\" intervention, which underperforms the adopted zero-masking strategy across metrics. This strengthens the justification of using zero-masking in our method. Moreover, we performed analysis to show that the advantage of zero-masking is driven by the targeted concept masking instead of generic image corruption.\n- **Evaluation scope and model coverage**: We further clarified that our benchmark is anchored to human annotations and that binary VQA was chosen to enable clean causal filtering given the annotation resources available for CXR datasets. To account for differences in annotation granularity across datasets, we reported precision, recall, and F1 in addition to IoU. Based on the suggestion, we added another in-domain LVLM (Lingshu-7B), on which MedFocus achieves the best overall attribution performance, consistent with findings across the original six models.\n\nWe believe these revisions have strengthened our paper. We would be happy to provide further clarifications if there are any remaining concerns.\n\nThank you again for your time and consideration.\n\nSincerely,\n\nAuthors of Submission 15134"
+ },
+ "createdAt": "2026-08-01T22:19:43.621Z",
+ "modifiedAt": "2026-11-19T16:58:42.402Z",
+ "url": "https://openreview.net/forum?id=YoNjeiTDbj&noteId=gOX8cxUNig",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/yonjeitdbj/notes/oesw43hiir.json added

+++ b/reviews/openreview/yonjeitdbj/notes/oesw43hiir.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "oesW43hIir",
+ "replyTo": "CleJ64KK82",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you for your engagement and thoughtful follow-up. We are glad that our rebuttal \"**resolves the majority of**\" your concerns, and would like to provide the following clarifications on the remaining points.\n\nWe agree that our MedFocus has an inductive advantage over pixel-based methods, and this is a deliberate design choice for better alignment with human understanding. Regarding evaluation, concept-level attribution can be an advantage or disadvantage depending on the granularity of the ground-truth annotation. For example, in our main experiments (Table 1), MedFocus shows lower precision on VinDR-CXR and PadChest-GR than on ImaGenome because these datasets provide finer-grained finding-level annotations, closer to the \"finer clinical descriptors\" you mentioned, but MedFocus still provides more precise attribution than most baselines and shows the highest IoU/F1 scores.\n\nAdditionally, MedFocus is proposed as a general framework whose concept vocabulary is not limited to anatomical regions. As discussed in the \"Vocabulary granularity\" paragraph of Appendix D, the vocabulary can be expanded with finer clinical concepts for more detailed grounding. Given your remaining concern, we will make this extensibility more prominent in the revised paper, noting the limitations of the current anatomical-region-based implementation and describing its extension to finer-grained concepts as a future direction.\n\nThank you again for your constructive feedback and for recognizing our concept-level attribution method as \"**novel and an intriguing research direction that is also clearly motivated**\". We hope these clarifications resolve your remaining concerns."
+ },
+ "createdAt": "2026-08-04T00:38:49.575Z",
+ "modifiedAt": "2026-11-19T16:58:42.198Z",
+ "url": "https://openreview.net/forum?id=YoNjeiTDbj&noteId=oesW43hIir",
+ "license": "CC-BY-4.0"
+}