Extremely Sparse-View Computed Tomography from 2D Projections via Pose-Aware Diffusion Priors
Update NeurIPS 2026 submission HvYYOiRYrE: 8 notes
@openreview[bot] · 2026-11-24 15:48 UTC · 011f9a4f91e6 ·
reviews/openreview/hvyyoiryre/notes/1kclnlzauz.json modified
+++ b/reviews/openreview/hvyyoiryre/notes/1kclnlzauz.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair aDMb","content": {- "metareview": "This paper addresses the challenge of Extremely Sparse-View Computed Tomography (xSV-CT) under a highly restrictive \"train-sparse / infer-sparse\" paradigm. The authors propose a framework consisting of: (1) A 2D denoising diffusion probabilistic model (DDPM) trained on only a single 2D projection per training sample, augmented with sinusoidal pose encoding and multi-scale cross-attention injection to learn angle-conditioned projection statistics; and (2) A testing-time guidance loop that directs reverse diffusion sampling using two complementary constraints: a geometric coherency loss and a physics-informed consistency loss. Evaluations on two public datasets (CT-RATE and SinoCT) show state-of-the-art performance in synthesizing novel views and reconstructing highly accurate 3D volumes under 1-, 4-, and 8-view contexts. \n\nThe manuscript received mixed reviews with major concerns around evaluation and the situation of the work in the body of existing methods. Specifically, the negative review points out a large body of published works on sparse view CT that the authors did not discuss or compare to in detail; however, without specifying any specific work that the authors miss discussing. The authors did address this concern in the discussion phase with additional discussion of the broader landscape of related methods. The review panel agreed to recommend this work for acceptance."+ "metareview": "This paper addresses the challenge of Extremely Sparse-View Computed Tomography (xSV-CT) under a highly restrictive \"train-sparse / infer-sparse\" paradigm. The authors propose a framework consisting of: (1) A 2D denoising diffusion probabilistic model (DDPM) trained on only a single 2D projection per training sample, augmented with sinusoidal pose encoding and multi-scale cross-attention injection to learn angle-conditioned projection statistics; and (2) A testing-time guidance loop that directs reverse diffusion sampling using two complementary constraints: a geometric coherency loss and a physics-informed consistency loss. Evaluations on two public datasets (CT-RATE and SinoCT) show state-of-the-art performance in synthesizing novel views and reconstructing highly accurate 3D volumes under 1-, 4-, and 8-view contexts. \n\nThe manuscript received mixed reviews with major concerns around evaluation and the situation of the work in the body of existing methods. Specifically, the negative review points out a large body of published works on sparse view CT that the authors did not discuss or compare to in detail; however, without specifying any specific work that the authors miss discussing. The authors did address this concern in the discussion phase with additional discussion of the broader landscape of related methods. The review panel agreed to recommend this work for acceptance.",+ "final_justification": "See metareview."},"createdAt": "2026-07-22T19:28:47.435Z",- "modifiedAt": "2026-11-18T15:21:35.781Z",+ "modifiedAt": "2026-11-19T05:00:57.605Z","url": "https://openreview.net/forum?id=HvYYOiRYrE¬eId=1KCLnlZAUZ","license": "CC-BY-4.0"}
reviews/openreview/hvyyoiryre/notes/3wr6pzas3t.json added
+++ b/reviews/openreview/hvyyoiryre/notes/3wr6pzas3t.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "3Wr6pzAs3T",+ "replyTo": "DCtl6FDBZC",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer KBVa",+ "content": {+ "comment": "Thank you for the detailed response. The rebuttal has addressed some of my questions, particularly W3 (projection-domain versus slice-domain priors), W4, and Q1. I appreciate the authors’ willingness to incorporate these discussions into the final version. In particular, I believe that a more thorough discussion of W3 would help the community better understand when each of these two paradigms should be preferred.\n\nHowever, I still have several concerns regarding the remaining issues.\n\n**W1: Motivation, validation of the proposed setting, and novelty** \n\nThe authors provide clearer examples of the scenarios for which the proposed train-sparse / infer-sparse setting may be relevant, including evolving batteries, beating hearts, and delicate biological or archaeological specimens that may be damaged by prolonged X-ray exposure. However, it is unfortunate that the method is not actually evaluated on data from any of these scenarios.\n\nI understand that acquiring such data may be difficult. Nevertheless, these applications constitute the central motivation for the proposed setting, and they may present challenges that differ substantially from those found in conventional medical CT data, such as temporal changes, non-standard materials, severe distribution shifts, or different imaging physics. Consequently, evaluation only on standard medical CT datasets leaves a gap between the motivating applications and the current experimental validation.\n\nI would also like to correct one point concerning SinoCT. According to the official dataset description, the SinoCT sinograms were simulated using GE’s CatSim software. Although CatSim is a validated, high-fidelity simulator for GE scanners, these sinograms should not be described as physically acquired projection data. They are more realistic than projections generated using a simplified Radon transform, but they remain simulated rather than directly measured.\n\nThe authors also emphasize that this is “the first work among existing publications to explicitly study” the train-sparse / infer-sparse setting. However, Lai et al. [1] appear to have explored a conceptually related setting. Their method, which is similar in spirit to pixelNeRF, reconstructs knee CT volumes from sparse biplanar X-rays using a self-supervised neural field without relying on high-quality CT volumes as supervision. Their training projections are not as sparse as the one-view-per-sample setting considered here, so the two settings are not identical. Nevertheless, this prior work seems sufficiently related that the novelty claim should be qualified and the distinction discussed explicitly.\n\n**W2: Reproduction of C²RV**\n\nI remain unconvinced that the reported C²RV results constitute a reasonable reproduction. The authors’ explanation that “it behaves correctly as the view count grows” is insufficient. It is expected that reconstruction quality improves as more views are provided; this trend alone does not validate the absolute quality of the reproduction.\n\nIn particular, the C²RV results in Figs. 20 and 23 remain highly blurred even with eight input views. By contrast, Fig. 5 of the original C²RV paper presents substantially sharper reconstructions using only six views. This discrepancy is difficult to explain because both studies primarily operate on volumes of approximately ($256^3$) resolution, and the CT-RATE training set used in this submission appears to contain more training cases.\n\nThe authors should therefore provide a more convincing explanation for this gap, together with sufficient implementation details to establish that C²RV was trained and evaluated appropriately. Simply showing that its performance improves monotonically with the number of views does not resolve the concern that this baseline may be significantly underperforming relative to its original implementation."+ },+ "createdAt": "2026-08-03T05:31:58.658Z",+ "modifiedAt": "2026-11-19T17:09:11.165Z",+ "url": "https://openreview.net/forum?id=HvYYOiRYrE¬eId=3Wr6pzAs3T",+ "license": "CC-BY-4.0"+}
reviews/openreview/hvyyoiryre/notes/mf9jjpzhe4.json added
+++ b/reviews/openreview/hvyyoiryre/notes/mf9jjpzhe4.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "mf9jJPzHe4",+ "replyTo": "wCQZRxsinu",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the careful follow-up and for pressing on these points.\n\n## W1.\n\n**Lai et al.** Thank you for pointing this out. **As Reviewer KBVa notes, the training settings are not identical**: their method uses 90 projections per training sample with a fixed biplanar protocol at inference, whereas ours uses a single projection per sample at arbitrary poses. We agree, however, that the work is sufficiently related to warrant explicit discussion. We will therefore discuss the distinction clearly in revision, describing our contribution as introducing a train-sparse / infer-sparse setting with arbitrary acquisition poses for extremely sparse-view CT.\n\n**SinoCT.** Thank you for pointing this out. Our intention was to highlight that **SinoCT, being a publicly available large-scale projection dataset, provides a more realistic evaluation by modeling scanner-specific physics beyond our simplified CT-RATE simulation**. We apologize that our description was imprecise. The sinograms are CatSim simulations, not physically acquired measurements, and we will correct it in revision accordingly. CatSim models a polychromatic source and detector response, which are not included in naively noised Radon projections of CT-RATE. Therefore, SinoCT evaluates our method under more realistic scanner physics than those assumed in simple Radon transform.\n\n**Motivating scenarios.** We agree the gap exists, as listed in the limitation in our paper. Closing it is not straightforward: quantitative evaluation needs paired dense references for learning-based baselines, and in these scenarios they do not exist by construction. Public dense-view datasets are a controlled proxy, with dense views withheld from our method and used only for metrics. Currently, our work serves to **validate that projection-domain priors can be used for tomographic reconstruction under sparse view inputs.** We will scope the motivation accordingly, and are collecting specimen data for a qualitative prospective study in future work.\n\n\n## W2. C²RV\n\nWe will clarify our protocol further in the revision. There is a possible training-scheme difference, from which we believe the performance discrepancy stems from. To ensure a fair comparison with our method that selects a random pose-projection pair for each sample, C²RV (and DSDF) are retrained per-view-count under **the same random training pair selection**; while the original C²RV, judging from its code implementation, **reuse the same relative poses at training and inference with uniform pair selection**, so it is built for a matched, dataset-wise geometry, which is why they degrade under arbitrary pose.\n\nFollowing this, we ran the implied check (a short run for 8-view reconstruction at 17 epochs, not a complete training) with matching poses for training and inference, and we observe that the blurring effect is substantially reduced. Yet the low-contrast abdominal organs remain visually inseparable (like the 6-view reconstruction in Fig.5 of original paper), and a visual gap to our method persists. In revision, we will report C²RV and DSDF under both protocols with full training details, isolating how much of the gap comes from the pose-matching requirement and how much from extreme sparsity.\n\n## Additional concern: Runtime\n\nWe thank the reviewer for the pointers to DDS, ISCS and DiffusionBlend, which minimize latency. We also agree that **we have comparable** (47 minutes on 8-view 256³ reconstruction, against 48 minutes for DDS and 32 minutes for DiffusionBlend++, as reported in Tab.9 in DiffusionBlend)**, rather than superior, efficiency to more recent baselines**. We will clearly describe our method as removing the requirement for densely scanned training data while having comparable runtime as the latest baselines.\n\n## Overall assessment: When a projection-domain prior is preferable.\n\n We will make this explicit in the main text. **Where a corpus of dense projections cannot be assembled** (because targets are non-repeatable or dense acquisition is itself the constraint), a projection-domain prior trains on measurements being collected easier and outperforms self-supervised per-scene methods at low acquisition cost. **Its advantage also concentrates at extreme sparsity**: at the 1/4/8-view settings evaluated here, projection-domain priors degrade less than slice-domain priors under insufficient regularization (Fig. 7), and the margin narrows as views increase. We will mark these boundaries explicitly in revision."+ },+ "createdAt": "2026-08-04T10:27:40.739Z",+ "modifiedAt": "2026-11-19T17:09:11.182Z",+ "url": "https://openreview.net/forum?id=HvYYOiRYrE¬eId=mf9jJPzHe4",+ "license": "CC-BY-4.0"+}
reviews/openreview/hvyyoiryre/notes/uzvip6glnr.json added
+++ b/reviews/openreview/hvyyoiryre/notes/uzvip6glnr.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "UzvIp6gLnr",+ "replyTo": "MeJD7i5Ctw",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Brief summary of our previous rebuttal",+ "comment": "Dear Reviewer NpsB,\n\nThank you again for the time you spent on our submission. We provide a pointer to where your main concerns are addressed here (updated after discussion with Reviewer KBVa); please see our earlier response for other details:\n\n- On inference time: although reducing reconstruction latency is not our primary target, compared with more recent baselines DiffusionBlend, DDS for sparse-view reconstruction as pointed by Reviewer KBVa, our model retains **comparable inference latency**, rather than being superior. We will clearly describe our method as removing the requirement for densely scanned training data while having comparable runtime as the latest baselines.\n- On positioning: we will add the **single-/few-view X-ray-to-CT generation line**, including \"Patient-specific reconstruction…\" (Nature BME'19), X2CT-GAN, and MedM2G, crediting them as establishing that networks can infer volumetric structure from very few views. We will also make clear how our setting differs: like the volume-based methods we already discuss, these approaches still **form their training pairs from reconstructed slices or volumes**, and are non-trivial to retrain or apply at a different view count than they were designed for. We would also include the work Lai et al. (ISBI'24) from Reviewer KBVa, which also **assumes dense-view supervision, but learns solely on projections.** If other work belongs in this discussion, we would welcome the pointers, now or for the revision.\n- We also thank Reviewer KBVa for pointing out that our previous description of SinoCT was insufficiently precise. We will clarify the original question Q2 in the following: To quantitatively evaluate the performance of different methods under a more realistic setting, we included SinoCT with CatSim-simulated projections. Currently, our work serves to **validate that projection-domain priors can be used for tomographic reconstruction under sparse view inputs.** We will scope the motivation accordingly, and are collecting specimen data for a qualitative prospective study in future work.\n\n\nWe remain available for any further clarification while the author discussion window is open."+ },+ "createdAt": "2026-08-02T11:16:23.243Z",+ "modifiedAt": "2026-11-19T17:09:11.181Z",+ "url": "https://openreview.net/forum?id=HvYYOiRYrE¬eId=UzvIp6gLnr",+ "license": "CC-BY-4.0"+}
reviews/openreview/hvyyoiryre/notes/wcqzrxsinu.json added
+++ b/reviews/openreview/hvyyoiryre/notes/wcqzrxsinu.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "wCQZRxsinu",+ "replyTo": "3Wr6pzAs3T",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer KBVa",+ "content": {+ "comment": "**Additional concern: runtime comparisons and omitted accelerated baselines**\n\nI also noticed the discussion of inference time in the response to reviewer NpsB. In my view, the current runtime comparison is selective and risks overstating the efficiency advantage of the proposed method.\n\nThe authors use DiffusionMBIR and TPDM as representative diffusion-based baselines. However, both methods are exceptionally slow and are no longer representative of the computational efficiency achievable by diffusion-based 3D reconstruction methods in 2026. Several subsequent methods were developed specifically to address this limitation and reduce the runtimes of $256³$ volume reconstruction on the order of tens of minutes. Such as DDS [2], ISCS [3] and DiffusionBlend [4].\n\nThese methods are more appropriate references when discussing the practical efficiency of modern slice-domain or volumetric diffusion priors. Comparing primarily against DiffusionMBIR and TPDM makes the proposed method appear faster than it would under a more current baseline set. I therefore encourage the authors to revise the runtime discussion and include, or at least explicitly acknowledge, these accelerated alternatives.\n\n**Overall assessment**\n\nBased on the rebuttal, I will maintain my current score.\n\nI believe that the submission still has some distance to go before being sufficiently convincing for presentation at NeurIPS. My remaining concerns primarily involve:\n\n1. the lack of validation on the application scenarios used to motivate the proposed train-sparse / infer-sparse setting;\n2. the questionable reproduction quality of an important baseline;\n3. the strength of the novelty claim; and\n4. the selectivity of the performance and efficiency comparisons.\n\nTo me, the most compelling potential contribution of this paper is that it appears to make a projection-domain prior genuinely effective for extremely sparse-view CT reconstruction, whereas previous projection-domain approaches have often performed poorly. This could be useful and informative for the community. However, the central question still requires more careful examination: **under what acquisition conditions or application scenarios is a projection-domain prior actually preferable to a slice-domain prior?** The current experiments and rebuttal do not yet provide a sufficiently clear answer.\n\n\n\n> [1] Lai, Shuyang, et al. “Reconstructing Knee CT Volumes from Biplanar X-Rays via Self-Supervised Neural Field.” *IEEE International Symposium on Biomedical Imaging (ISBI)*, 2024.\n>\n> [2] Chung, Hyungjin, Suhyeon Lee, and Jong Chul Ye. “Decomposed Diffusion Sampler for Accelerating Large-Scale Inverse Problems.” *International Conference on Learning Representations (ICLR)*, 2024.\n>\n> [3] Du, Chenhe, et al. “Improving 2D Diffusion Models for 3D Medical Imaging with Inter-Slice Consistent Stochasticity.” *International Conference on Learning Representations (ICLR)*, 2026.\n>\n> [4] Song, Bowen, et al. “DiffusionBlend: Learning 3D Image Prior through Position-Aware Diffusion Score Blending for 3D Computed Tomography Reconstruction.” *Advances in Neural Information Processing Systems*, 2024."+ },+ "createdAt": "2026-08-03T05:32:19.329Z",+ "modifiedAt": "2026-11-19T17:09:11.231Z",+ "url": "https://openreview.net/forum?id=HvYYOiRYrE¬eId=wCQZRxsinu",+ "license": "CC-BY-4.0"+}
reviews/openreview/hvyyoiryre/notes/yjfjls2zp7.json added
+++ b/reviews/openreview/hvyyoiryre/notes/yjfjls2zp7.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "yjFjLs2Zp7",+ "replyTo": "rc8r9gpUEV",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Brief summary of our previous rebuttal",+ "comment": "Dear Reviewer KBVa,\n\nThank you again for your careful reading. We provide a brief pointer to where each of your main concerns is addressed here as a summary; please see our earlier response for the full details:\n\n- On the train-sparse setting: each training sample is a **single (projection, pose) pair**, and samples are never grouped by object identity, so the model never observes two views of the same object.\n- On baselines and implementation: we used the **official code for each method, retraining per-dataset and per-view-count where needed**. For C²RV, the indication that our implementation is faithful is that its quality rises steadily with view count and reaches non-blurry reconstructions (Fig. 7, Appendix E); the blur is a property of the M ≤ 8 regime.\n- On projection- vs. volume-domain gains: we explain why our result does not contradict DiffNR's observation, and why **projection-based modeling is preferable when a large dense-view dataset cannot easily be curated and/or a high level of sparsity is required**.\n- On off-model physics: as requested, we introduce synthetic beam-hardening artifacts into the input measurements and find that **our method remains meaningfully robust, accurately locating the metal presence while suppressing the streak artifacts around the synthetic metal**.\n\nWe are also happy to address any further questions you might have during the author discussion phase."+ },+ "createdAt": "2026-08-02T11:11:07.525Z",+ "modifiedAt": "2026-11-19T17:09:11.248Z",+ "url": "https://openreview.net/forum?id=HvYYOiRYrE¬eId=yjFjLs2Zp7",+ "license": "CC-BY-4.0"+}
reviews/openreview/hvyyoiryre/notes/zkiysbzvsh.json added
+++ b/reviews/openreview/hvyyoiryre/notes/zkiysbzvsh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "zKiySbZVsH",+ "replyTo": "EmQZWN7jG3",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Brief summary of our previous rebuttal",+ "comment": "Dear Reviewer JyFa,\n\nThank you again for your careful reading. Here is a brief note on how your comment will shape the revision, we are also open to any further question you may have in mind during the author discussion phase.\n\nFollowing your suggestion, we have posted a response discussing the connection between our sampling guidance and the DPS and DDNM families, covering both the similarities (a **DPS-style gradient update through the Tweedie estimate**, and a **DDNM-like range/null-space view of the consistency loss**) and a key difference: our prior is learned from single, pose-conditioned 2D projections with **no target-domain (reconstruction) data guidance at any stage**, combined with guidance objectives specific to tomography rather than generic data fidelity."+ },+ "createdAt": "2026-08-02T11:13:11.919Z",+ "modifiedAt": "2026-11-19T17:09:11.246Z",+ "url": "https://openreview.net/forum?id=HvYYOiRYrE¬eId=zKiySbZVsH",+ "license": "CC-BY-4.0"+}
reviews/openreview/hvyyoiryre/notes/zsbtcqwsog.json added
+++ b/reviews/openreview/hvyyoiryre/notes/zsbtcqwsog.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "zSBTCQwSog",+ "replyTo": "1KCLnlZAUZ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Area Chair aDMb",+ "comment": "**We sincerely thank the Area Chair for the clear and constructive summary of the reviews and for identifying the key issues that should be addressed during the discussion period. We carefully prepared our rebuttal to directly address each of these concerns.**\n\n**Regarding the empirical validation**, we have added a per-baseline implementation description and an explanation of C²RV's behavior at M≤8, an off-model physics stress test, a sharper definition of the train-sparse setting (for KBVa), and a inference-time analysis (for NpsB). All methods are evaluated on two datasets, one with a simple Radon model and the other with a realistic scanner-physics simulator, to probe performance under both ideal and more realistic scenarios. (for NpsB, updated after discussion with Reviewer KBVa).\n\n**Regarding the positioning with respect to prior work**, following the Area Chair’s suggestion, we expanded the discussion of the relevant sparse-view CT and X-ray-to-CT generation literature we believe NpsB has in mind, and credited it explicitly; **each still forms its training pairs from reconstructed volumes, the requirement our train-sparse setting removes**. If the reviewer names any specific work or baseline they consider missing, we will discuss or run it within the discussion period.\n\nThe remaining concerns, including technical clarity and the underlying assumptions, are addressed point by point in our rebuttal. We would be grateful for any additional feedback from the Area Chair or the reviewers and are happy to provide further clarifications or experiments if they would be helpful during the discussion period."+ },+ "createdAt": "2026-07-29T07:29:37.688Z",+ "modifiedAt": "2026-11-19T17:09:11.250Z",+ "url": "https://openreview.net/forum?id=HvYYOiRYrE¬eId=zSBTCQwSog",+ "license": "CC-BY-4.0"+}