potentialpaper

SOAR: Semantic Organ-Aware Pretraining for 3D CT Image Understanding

Import NeurIPS 2026 submission xwakWJUI55: 8 notes

@openreview[bot] · 2026-11-22 18:00 UTC · f3d42590bf19 ·

Evidence

reviews/openreview/xwakwjui55/forms.json added

+++ b/reviews/openreview/xwakwjui55/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xwakwjui55/notes/bqpzirg13x.json added

+++ b/reviews/openreview/xwakwjui55/notes/bqpzirg13x.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "bqPZirg13x",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer PZ3k",
+ "content": {
+ "summary": "The authors introduce SOAR, a pre-training method for CT imaging. SOAR consists of three main components: organ-level masked reconstruction, organ-level vision-language alignment, and organ-level supervision, which are combined in one objective with the aim of pre-training a ViT vision encoder for downstream application. They experiment with multiple tasks and demonstrate performance superior to self-supervised baselines.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "I read the paper in detail and found several strengths and weaknesses:\n\nStrengths:\n- Experimental results including selected metrics are quite elaborate and conducted on multiple datasets. \n- SOAR generalizes well to multiple downstream tasks.\n- SOAR, in general, outperforms self-supervised baselines on the presented tasks.\n- SOAR is well-motivated. The task of foundational ViT CT pre-training is relevant to the community and could potentially benefit multiple applications.\n- The method is in general easy to follow.\n- The authors claim that code will be available.\n\nWeaknesses:\n- Extremely underwhelming and confusing ablation studies. It is unclear to me how ‘replacing random patch masking with random organ masking improves multiple-choice accuracy from 85.76% to 88.64%’ (L314-315), given that Tab3 exclusively compares the number of classes used for masking, L_organ-super, and the use of organ-specific mask tokens in L_organ-recon, and L_organ-align. The method consists of three loss components: L_organ-super, L_organ-recon, and L_organ-align. There is no ablation on switching individual loss components off, which would yield insights into their necessity. Further, ablations of core components should be conducted on multiple downstream tasks.\n- Missing baselines. Given that the model uses ground truth labels for pre-training, it does not classify as self-supervised. I, therefore, disagree strongly with the authors statement: 'SOAR can also be viewed as a self-supervised pre-training method, since it does not rely on manual anatomical annotations but instead uses automatically derived anatomical priors from medical image segmentation foundation models' (L100-103). Given that, it is essential to compare to supervised baselines, such as [1, 2, 3] or simply encoders of pre-trained anatomical segmentation models such as [4, 5, 6].\n- Conceptual issues. The Organ-level Vision-language Alignment module is not based on reports, but rather on simple class labels and does therefore not account for abnormal structures and diseases. Further, simple alignment to an embedding derived from the class name is far from ‘vision-language alignment’. I am interested in seeing the performance of SOAR if their tokens derived from PubMedBERT are exchanged with simple, fixed class tokens. This needs to be ablated in detail.\n- Missing downstream tasks. It would be interesting to see SOAR’s performance on segmentation and detection tasks.\n- No statistical significance for ablation results. These are necessary, given low performance delta in Tab3.\n- It is unclear whether their in-house esophageal cancer screening dataset will be release to the public.\n- SOAR depends heavily on TotalSegmentator, which does not represent the state-of-the-art [5]. It is therefore inherently limited to CT (and MR) images.\n\nIn summary, the weaknesses clearly outweigh the strengths of this paper. In particular, the ablations are incomplete and the baseline selection is unfair, which prevents a valid assessment of SOAR's contribution. Although the paper is well-motivated and there is a clear need of foundational CT encoders in the medical community, I can not recommend to accept SOAR at NeurIPS.\n\n[1] Varma, Maya, et al. \"MedVAE: Efficient automated interpretation of medical images with large-scale generalizable autoencoders.\" arXiv preprint arXiv:2502.14753 (2025).\\\n[2] Chen, Qi, et al. \"Foundation VAEs for 3D CT Reconstruction, Augmentation, and Generation.\" arXiv preprint arXiv:2605.30893 (2026).\\\n[3] Guo, Pengfei, et al. \"Maisi: Medical ai for synthetic imaging.\" 2025 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV). IEEE, 2025.\\\n[4] Wasserthal, Jakob, et al. \"TotalSegmentator: robust segmentation of 104 anatomic structures in CT images.\" Radiology: Artificial Intelligence 5.5 (2023): e230024.\\\n[5] Xu, Murong, et al. \"CADS: A Comprehensive Anatomical Dataset and Segmentation for Whole-Body Anatomy in Computed Tomography.\" arXiv preprint arXiv:2507.22953 (2025).\\\n[6] He, Yufan, et al. \"VISTA3D: A unified segmentation foundation model for 3D medical imaging.\" Proceedings of the Computer Vision and Pattern Recognition Conference. 2025.",
+ "quality": 1,
+ "clarity": 3,
+ "significance": 2,
+ "originality": 3,
+ "questions": "Suggestion: Please compare to supervised baselines for fair comparison.\\\nSuggestion: SOAR needs to be ablated in detail (each introduced component individually).\\\nSuggestion: I would appreciate downstream experiments on segmentation tasks.",
+ "limitations": "yes",
+ "rating": 2,
+ "confidence": 4,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "none",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "As discussed in the rebuttal, I find the paper's framing issues to be deeply rooted. Even though the authors have backtracked on positioning SOAR as self-supervised, I believe that all experimental results require comparison against multiple fully supervised baselines - verification that goes beyond what can be done within the narrow time frame of the rebuttal period. Given that, I still favor rejecting the paper."
+ },
+ "createdAt": "2026-06-16T09:06:54.388Z",
+ "modifiedAt": "2026-11-18T13:40:03.020Z",
+ "url": "https://openreview.net/forum?id=xwakWJUI55&noteId=bqPZirg13x",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xwakwjui55/notes/movikhivue.json added

+++ b/reviews/openreview/xwakwjui55/notes/movikhivue.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "MoVIKHiVuE",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer ZNxd",
+ "content": {
+ "summary": "This paper proposes SOAR, a 3D CT pretraining framework that uses automatically generated organ segmentation masks to inject organ-level structure and semantics into visual representation learning. The method combines three objectives, organ-level masked reconstruction, organ-level vision-language alignment using organ-name prompts, and an auxiliary organ segmentation loss. The authors pretrain on CT-RATE and evaluate on multiple downstream tasks, including VQA, disease screening, and abnormality detection, reporting consistent gains over MAE, CLIP, fVLM, ViSD, and VoCo. The main claim is that organ-aware supervision reduces the semantic mismatch of report-based 3D CT pretraining and yields more transferable CT representations.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "**`Strengths`**\n\n1. **Clear and well-motivated problem setting**: The paper identifies a plausible mismatch between dense anatomical information in 3D CT and sparse report-based supervision, and Figure 1 illustrates this issue effectively. Using organs as an intermediate unit of supervision is a natural and intuitive design choice.\n\n2. **Simple method with reasonably broad evaluation**: Figure 2 clearly presents the three components—organ-level reconstruction, segmentation supervision, and vision-language alignment—and the overall framework is modular. The experiments cover multiple VQA, disease screening, and abnormality detection tasks, providing reasonably broad evidence of effectiveness.\n\n3. **Results generally support the central hypothesis**: SOAR is competitive on most tasks in Tables 1 and 2. Table 3 suggests that the proposed components may provide complementary benefits, while Figure 3 offers preliminary qualitative support for improved anatomical localization.\n\n**`Weaknesses`**\n\n1. **The degree of technical novelty remains somewhat unclear**: The method mainly combines organ-guided masking, regional feature aggregation, contrastive learning, and auxiliary segmentation at the organ level. A more systematic comparison with closely related work would help clarify the exact technical contribution.\n\n2. **The role of the external segmentation prior is not sufficiently disentangled**: SOAR relies on pseudo-labels generated by TotalSegmentator, but the paper lacks a segmentation-only baseline, robustness tests under noisy pseudo-labels, and controls with matched masking ratios. As a result, the independent contribution of each design choice is not fully established.\n\n3. **The strength of the results and the scope of generalization remain limited**: Some gains are small and SOAR is not consistently best across all metrics. The qualitative examples are mainly lung-focused, and pretraining is conducted primarily on non-contrast chest CT, so broader applicability to general 3D CT settings requires further validation.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 2,
+ "questions": "1. **Robustness to pseudo-label quality**: Can the authors evaluate how SOAR performs when TotalSegmentator masks are degraded, partially removed, or merged into coarser anatomical groups? A lightweight sensitivity analysis would help clarify the method’s dependence on the quality and granularity of the external segmentation prior.\n\n2. **Broader qualitative evidence**: Can the authors provide one or two abdominal or multi-organ qualitative examples, preferably from AMOS-MM, to better support the broader organ-aware claim beyond the predominantly pulmonary cases currently shown?\n\nI have limited familiarity with this specific research area and will therefore also take the other reviewers’ comments and assessments into account when forming my final judgment.",
+ "limitations": "yes",
+ "rating": 4,
+ "confidence": 2,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No major issues.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The rebuttal addresses most of my empirical concerns. The added TotalSegmentator baseline, distorted-mask experiment, and masking-ratio analysis better disentangle the contribution of the proposed organ-aware objectives, while the additional abdominal examples strengthen the evidence for generalization beyond chest CT. My main remaining reservation is the degree of technical novelty: although the rebuttal clarifies the distinction from related methods, I still view SOAR primarily as an effective integration of existing techniques around fine-grained organ-aware supervision. Overall, the rebuttal provides meaningful additional evidence and resolves most of my original concerns, so I maintain my positive recommendation."
+ },
+ "createdAt": "2026-06-28T19:45:52.853Z",
+ "modifiedAt": "2026-11-18T13:40:00.035Z",
+ "url": "https://openreview.net/forum?id=xwakWJUI55&noteId=MoVIKHiVuE",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xwakwjui55/notes/okqalrmagi.json added

+++ b/reviews/openreview/xwakwjui55/notes/okqalrmagi.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "OKqaLrMAgi",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair SYb6",
+ "content": {
+ "metareview": "The proposal of SOAR—to inject organ-level anatomical priors into 3D CT visual representation learning—and its core motivation of alleviating the semantic mismatch between sparse diagnostic-report supervision and dense 3D CT anatomical information, received unanimous recognition from the three reviewers. However, the reviewers' scores diverged significantly (4: Borderline Accept, 5: Accept, 2: Reject), reflecting deep-seated disagreements over the paper's technical rigor and experimental completeness. One reviewer explicitly pointed out that SOAR should not be categorized as a self-supervised method, since it relies on pseudo-labels generated by TotalSegmentator as supervisory signals, which is fundamentally different from truly self-supervised pre-training approaches such as MAE. Therefore, the authors must supplement fair comparisons with supervised pre-training baselines (e.g., MedVAE, Foundation VAEs, pre-trained segmentation model encoders); otherwise, the baseline selection suffers from serious unfairness. In addition, two reviewers jointly noted critical omissions in the ablation study: the paper does not perform independent on/off ablations for each loss component, making it impossible to assess the necessity and individual contribution of each component. Moreover, a comparison between PubMedBERT embeddings and simple fixed class tokens is missing, which is essential to support the claimed technical contribution of \"organ-level visual-language alignment.\" Regarding the evaluation scope, two reviewers pointed out that the current qualitative examples are overly focused on the lungs, the pre-training data is limited to non-contrast chest CTs, and fine-grained downstream tasks such as segmentation and detection are absent—all of which weaken the generalizability evidence for the claimed \"organ-aware\" capability. Another reviewer also noted potential class imbalance in the organ labels and suggested supplementing organ-coverage statistics. The reviewers also raised concerns about the availability of the internal dataset, which affects result reproducibility. Overall, SOAR's core idea demonstrates clear problem awareness and application potential. However, the current version has substantive deficiencies in terms of method positioning accuracy, fairness of baseline comparisons, completeness of ablation designs, and systematic analysis of dependence on external segmentation priors. The experimental evidence is not yet sufficient to fully support its core claims. Therefore, my inclination is toward the borderline of acceptance, and the final decision is left to the SAC."
+ },
+ "createdAt": "2026-07-13T06:59:23.193Z",
+ "modifiedAt": "2026-11-18T15:21:49.469Z",
+ "url": "https://openreview.net/forum?id=xwakWJUI55&noteId=OKqaLrMAgi",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xwakwjui55/notes/quysiyprap.json added

+++ b/reviews/openreview/xwakwjui55/notes/quysiyprap.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "qUysiyPrAp",
+ "replyTo": "WX0HvbdAwV",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Dear Reviewer Vm6a,\nWe sincerely thank you for your thoughtful and constructive feedback. We address each point below.\n\n> **W1**: The organ-level vision-language alignment mainly uses organ-name prompts rather than disease-aware or finding-aware text. This design is effective for anatomical grounding, but it may not fully capture fine-grained pathological semantics.\n\nWe appreciate this important observation. SOAR does not explicitly inject disease semantics during pretraining; instead, it preserves fine-grained visual information in anatomically grounded visual tokens through reconstruction and structural learning. During downstream instruction tuning, the LLM learns to associate these visual features with disease concepts and findings. Despite using only organ-name prompts during pretraining, SOAR achieves the best results across all anomaly-detection metrics on 3D-RAD and the highest disease-analysis accuracy on AMOS-MM, supporting the effectiveness of this training strategy. We explicitly acknowledge this design scope in Appendix C.\n\n> **W2**: The pretraining data are mainly chest and abdominal CT from CT-RATE. The organ labels could be highly imbalanced. Reporting organ coverage statistics would help clarify the robustness of the organ-level objectives.\n\nWe appreciate this helpful suggestion. As shown below, we computed organ-presence statistics from the TotalSegmentator masks across 50,185 valid CT-RATE volumes. Although coverage is imbalanced, it remains broad: 69 of 117 structures occur in at least 98\\% of volumes, and 82 occur in at least 90%. Coverage is nearly complete for thoracic structures, including the lung lobes (98.37\\%-98.45\\%) and heart (98.37\\%), and remains high for abdominal structures, including the liver (98.36\\%), spleen (98.18\\%), stomach (98.31\\%), pancreas (97.84\\%), kidneys (93.91\\%-96.10\\%), duodenum (92.56\\%), and colon (95.72\\%). Cranial and distal lower-body structures occur less frequently because they are not consistently included in routine thoracoabdominal CT acquisition ranges; for example, the skull appears in (43.07\\%) of volumes.\n\nConsistent with this broad abdominal coverage, SOAR achieves the best average performance on AMOS-MM, an abdominal CT benchmark. We will include the complete 117-class coverage statistics in the revision and release our pretrained weights and source code.\n\n| ID | Organ | Cov.(%) | # Vol. | ID | Organ | Cov.(%) | # Vol. | ID | Organ | Cov.(%) | # Vol. |\n|---:|:---|---:|---:|---:|:---|---:|---:|---:|:---|---:|---:|\n| 1 | spleen | 98.18 | 49272 | 40 | vertebrae_T4 | 98.36 | 49363 | 79 | spinal_cord | 99.96 | 50164 |\n| 2 | kidney_right | 93.91 | 47131 | 41 | vertebrae_T3 | 98.39 | 49376 | 80 | gluteus_maximus_left | 0.54 | 270 |\n| 3 | kidney_left | 96.10 | 48230 | 42 | vertebrae_T2 | 98.39 | 49377 | 81 | gluteus_maximus_right | 0.28 | 143 |\n| 4 | gallbladder | 88.02 | 44172 | 43 | vertebrae_T1 | 98.39 | 49379 | 82 | gluteus_medius_left | 0.42 | 210 |\n| 5 | liver | 98.36 | 49361 | 44 | vertebrae_C7 | 97.68 | 49020 | 83 | gluteus_medius_right | 0.41 | 208 |\n| 6 | stomach | 98.31 | 49336 | 45 | vertebrae_C6 | 73.44 | 36856 | 84 | gluteus_minimus_left | 0.16 | 82 |\n| 7 | pancreas | 97.84 | 49101 | 46 | vertebrae_C5 | 28.59 | 14349 | 85 | gluteus_minimus_right | 0.17 | 83 |\n| 8 | adrenal_gland_right | 97.74 | 49050 | 47 | vertebrae_C4 | 5.09 | 2554 | 86 | autochthon_left | 98.57 | 49469 |\n| 9 | adrenal_gland_left | 97.29 | 48827 | 48 | vertebrae_C3 | 2.40 | 1204 | 87 | autochthon_right | 98.53 | 49449 |\n| 10 | lung_upper_lobe_left | 98.45 | 49407 | 49 | vertebrae_C2 | 2.12 | 1062 | 88 | iliopsoas_left | 88.44 | 44382 |\n| 11 | lung_lower_lobe_left | 98.41 | 49388 | 50 | vertebrae_C1 | 2.09 | 1050 | 89 | iliopsoas_right | 90.44 | 45387 |\n| 12 | lung_upper_lobe_right | 98.43 | 49398 | 51 | heart | 98.37 | 49368 | 90 | brain | 3.25 | 1631 |\n| 13 | lung_middle_lobe_right | 98.37 | 49369 | 52 | aorta | 98.40 | 49384 | 91 | skull | 43.07 | 21617 |\n| 14 | lung_lower_lobe_right | 98.41 | 49385 | 53 | pulmonary_vein | 98.32 | 49341 | 92 | rib_left_1 | 98.22 | 49293 |\n| 15 | esophagus | 98.44 | 49403 | 54 | brachiocephalic_trunk | 98.20 | 49282 | 93 | rib_left_2 | 98.24 | 49304 |\n| 16 | trachea | 98.49 | 49428 | 55 | subclavian_artery_right | 98.28 | 49320 | 94 | rib_left_3 | 98.39 | 49375 |\n| 17 | thyroid_gland | 98.36 | 49361 | 56 | subclavian_artery_left | 98.29 | 49329 | 95 | rib_left_4 | 98.37 | 49367 |\n| 18 | small_bowel | 89.55 | 44941 | 57 | common_carotid_artery_right | 98.24 | 49303 | 96 | rib_left_5 | 98.36 | 49364 |\n| 19 | duodenum | 92.56 | 46450 | 58 | common_carotid_artery_left | 98.36 | 49360 | 97 | rib_left_6 | 98.37 | 49366 |\n| 20 | colon | 95.72 | 48036 | 59 | brachiocephalic_vein_left | 98.26 | 49310 | 98 | rib_left_7 | 98.36 | 49364 |\n| 21 | urinary_bladder | 1.29 | 649 | 60 | brachiocephalic_vein_right | 98.27 | 49319 | 99 | rib_left_8 | 98.35 | 49358 |\n| 22 | prostate | 0.14 | 69 | 61 | atrial_appendage_left | 98.13 | 49246 | 100 | rib_left_9 | 98.34 | 49352 |\n| 23 | kidney_cyst_left | 3.16 | 1586 | 62 | superior_vena_cava | 98.32 | 49340 | 101 | rib_left_10 | 98.32 | 49340 |\n| 24 | kidney_cyst_right | 4.20 | 2110 | 63 | inferior_vena_cava | 98.34 | 49353 | 102 | rib_left_11 | 98.23 | 49298 |\n| 25 | sacrum | 1.76 | 882 | 64 | portal_vein_and_splenic_vein | 96.67 | 48513 | 103 | rib_left_12 | 95.01 | 47681 |\n| 26 | vertebrae_S1 | 0.37 | 184 | 65 | iliac_artery_left | 0.76 | 380 | 104 | rib_right_1 | 98.22 | 49293 |\n| 27 | vertebrae_L5 | 1.00 | 500 | 66 | iliac_artery_right | 0.85 | 425 | 105 | rib_right_2 | 98.25 | 49305 |\n| 28 | vertebrae_L4 | 5.72 | 2871 | 67 | iliac_vena_left | 0.46 | 231 | 106 | rib_right_3 | 98.38 | 49371 |\n| 29 | vertebrae_L3 | 32.96 | 16539 | 68 | iliac_vena_right | 0.39 | 198 | 107 | rib_right_4 | 98.37 | 49369 |\n| 30 | vertebrae_L2 | 75.66 | 37968 | 69 | humerus_left | 98.14 | 49252 | 108 | rib_right_5 | 98.37 | 49365 |\n| 31 | vertebrae_L1 | 94.30 | 47323 | 70 | humerus_right | 98.16 | 49262 | 109 | rib_right_6 | 98.37 | 49366 |\n| 32 | vertebrae_T12 | 98.00 | 49182 | 71 | scapula_left | 98.47 | 49416 | 110 | rib_right_7 | 98.36 | 49363 |\n| 33 | vertebrae_T11 | 98.28 | 49324 | 72 | scapula_right | 98.46 | 49413 | 111 | rib_right_8 | 98.36 | 49360 |\n| 34 | vertebrae_T10 | 98.32 | 49344 | 73 | clavicula_left | 98.44 | 49400 | 112 | rib_right_9 | 98.34 | 49351 |\n| 35 | vertebrae_T9 | 98.35 | 49356 | 74 | clavicula_right | 98.44 | 49403 | 113 | rib_right_10 | 98.32 | 49344 |\n| 36 | vertebrae_T8 | 98.34 | 49351 | 75 | femur_left | 1.59 | 796 | 114 | rib_right_11 | 98.24 | 49300 |\n| 37 | vertebrae_T7 | 98.35 | 49356 | 76 | femur_right | 0.66 | 329 | 115 | rib_right_12 | 95.10 | 47728 |\n| 38 | vertebrae_T6 | 98.33 | 49348 | 77 | hip_left | 6.06 | 3040 | 116 | sternum | 98.38 | 49372 |\n| 39 | vertebrae_T5 | 98.35 | 49356 | 78 | hip_right | 3.24 | 1625 | 117 | costal_cartilages | 98.40 | 49380 |"
+ },
+ "createdAt": "2026-07-28T08:31:50.328Z",
+ "modifiedAt": "2026-11-18T17:17:11.983Z",
+ "url": "https://openreview.net/forum?id=xwakWJUI55&noteId=qUysiyPrAp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xwakwjui55/notes/rjxx7esqb6.json added

+++ b/reviews/openreview/xwakwjui55/notes/rjxx7esqb6.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "rJXX7eSqB6",
+ "replyTo": "bqPZirg13x",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Dear Reviewer PZ3k, we sincerely thank you for your thoughtful and constructive feedback. We address each point below.\n\n> **W1** Extremely underwhelming and confusing ...\n\nThe apparent discrepancy arises because these results appear in different tables: 85.76% is the random-patch MAE baseline in Table 1, whereas 88.64% is the organ-level reconstruction model with 30 masked organs in Table 3. We will add the MAE baseline to Table 3 in the revised paper.\n\nRegarding ablation studies of different losses, presented below, we performed the requested ablation study in the manuscript. Each component is isolated through a paired comparison. $\\Delta$ denotes the change relative to the preceding configuration. \n\n| Configuration | VQA Acc (%) | $\\Delta$ |\n|:---|---:|---:|\n| Random-patch MAE (no organ-level losses) | 85.76 | — |\n| $\\mathcal{L}_{\\text{organ-recon}}$ only | 88.64 | $+2.88$ |\n| $+\\mathcal{L}_{\\text{organ-super}}$ | 89.37 | $+0.73$ |\n| $+\\mathcal{L}_{\\text{organ-align}}$ (i.e., Full SOAR) | 89.87 | $+0.50$ |\n| Full SOAR w/o organ-conditioned mask tokens | 89.63 | $-0.24$ |\n\nFollowing the reviewer’s suggestion, we further evaluated all six ablation configurations on pneumonia classification and CT-RATE abnormality detection. As shown below, the proposed SOAR (last row) consistently provides robust overall performance across VQA and detection tasks.\n\nBest results are shown in **bold**, and second-best results are $\\underline{\\text{underlined}}$.\n\n| Organ-level reconstruction (# masked organs) | Organ-level supervision | Organ-conditioned mask tokens | Organ-level alignment | COVID-19 | Common pneumonia | Normal | Average | CT-RATE abnormality detection |\n|:---:|:---:|:---:|:---:|---:|---:|---:|---:|---:|\n| ✓ (10) | | | | 96.25 | 95.43 | 95.61 | 95.76 | 74.12 |\n| ✓ (30) | | | | 97.52 | 96.66 | 97.59 | 97.26 | $\\underline{74.71}$ |\n| ✓ (60) | | | | 95.69 | 94.51 | 94.97 | 95.06 | 74.00 |\n| ✓ (30) | ✓ | | | 97.67 | 96.39 | 97.19 | 97.08 | 73.23 |\n| ✓ (30) | ✓ | ✓ | | $\\underline{98.03}$ | $\\underline{97.30}$ | $\\underline{97.62}$ | $\\underline{97.58}$ | 74.28 |\n| ✓ (30) | ✓ | ✓ | ✓ | **98.79** | **97.47** | **97.72** | **97.99** | **75.38** |\n\n> **W2** Missing baselines. ......\n\nWe would like to clarify that SOAR does not use ground-truth anatomical labels during pretraining. As stated in Lines 100–103, manual organ annotations are unavailable for our pretraining dataset; instead, a frozen, open-source TotalSegmentator automatically derives coarse anatomical masks used only as auxiliary spatial priors, not as ground-truth supervision.\n\nAmong the six suggested baselines, MedVAE [1] provides a directly transferable CT encoder, whereas Foundation VAE [2] does not introduce or train a method-specific CT encoder and is contemporaneous work under the NeurIPS 2026 policy. MAISI [3] is a diffusion-based CT synthesis framework without a visual-token interface for downstream understanding and is therefore outside our scope. References [4–6] are segmentation foundation models. We therefore added two representative and directly comparable baselines: MedVAE [1] and TotalSegmentator [4]. We selected TotalSegmentator because it is the exact pseudo-label generator used by SOAR, making its encoder the most direct segmentation-only control for determining whether SOAR’s performance is inherited from segmentation pretraining.\n\nAs shown below, SOAR outperforms MedVAE by 0.55–14.17 points and the TotalSegmentator encoder by 1.60–7.30 points across all CT-RATE VQA metrics, confirming SOAR’s superior performance over both autoencoder- and segmentation-based baselines.\n\nEach $\\Delta$ denotes SOAR’s improvement over the corresponding baseline.\n\n| Task | Metric | MedVAE | TotalSegmentator | SOAR | $\\Delta_{\\text{MedVAE}}$ | $\\Delta_{\\text{TotalSeg}}$ |\n|:---|:---|---:|---:|---:|---:|---:|\n| Closed-ended VQA | Accuracy (%) | 75.70 | 87.12 | **89.87** | $\\uparrow 14.17$ | $\\uparrow 2.75$ |\n| Open-ended VQA | BLEU-1 | 44.29 | 41.97 | **49.27** | $\\uparrow 4.98$ | $\\uparrow 7.30$ |\n| | BLEU-2 | 34.21 | 33.20 | **38.19** | $\\uparrow 3.98$ | $\\uparrow 4.99$ |\n| | ROUGE-1 | 50.49 | 49.76 | **54.65** | $\\uparrow 4.16$ | $\\uparrow 4.89$ |\n| | METEOR | 45.84 | 46.67 | **51.15** | $\\uparrow 5.31$ | $\\uparrow 4.48$ |\n| | BERT-F1 | 91.45 | 90.40 | **92.00** | $\\uparrow 0.55$ | $\\uparrow 1.60$ |\n\n> **W3** Conceptual issues ......\n\nWe agree that our pretraining objective does not use radiology reports and therefore does not explicitly inject disease or abnormality semantics. Instead, SOAR preserves fine-grained visual information in anatomically grounded visual tokens through reconstruction and structural learning. During downstream instruction tuning, the LLM learns to associate these visual features with disease concepts and findings. The superior performance across the downstream benchmarks reported in the paper demonstrates the effectiveness of this design.\n\nFollowing the reviewer’s suggestion, we replaced the PubMedBERT-derived organ embeddings with fixed class tokens and retrained the encoder under identical settings. Presented below, the results on pneumonia and abnormality detection show that PubMedBERT-derived organ embeddings provide more effective supervision than simple class identifiers.\n\nAll results are AUC (%). $\\Delta$ denotes the improvement of SOAR over the fixed-class-token model.\n\n| Benchmark | Task/Class | Fixed class token | SOAR | $\\Delta$ |\n|:---|:---|---:|---:|---:|\n| Pneumonia classification | COVID-19 | 93.21 | **98.79** | $\\uparrow 5.58$ |\n| | Common pneumonia | 90.81 | **97.47** | $\\uparrow 6.66$ |\n| | Normal | 94.22 | **97.72** | $\\uparrow 3.50$ |\n| | Average | 92.75 | **97.99** | $\\uparrow 5.24$ |\n| CT-RATE abnormality | Average | 70.90 | **75.38** | $\\uparrow 4.48$ |\n\n> **W4** Missing downstream tasks. ......\n\n**Detection**: We would like to draw your attention to Tables 1-2 that evaluate SOAR on detection-oriented tasks, including anatomy and abnormality detection in 3D-RAD and AMOS-MM, scan-level disease detection, and 18-class abnormality detection on CT-RATE. Together, they assess whether SOAR representations capture the presence of anatomical structures and abnormalities.\n\n**Segmentation**: We agree that the original evaluation did not include segmentation. SOAR is designed primarily to produce fine-grained visual tokens for CT understanding tasks such as VQA and report generation. We therefore initially focused on these understanding tasks. Moreover, because SOAR pretraining already includes an auxiliary segmentation loss, a segmentation evaluation could inherently favor SOAR.\n\nTo fully address your concern, we evaluated all frozen encoders on KiTS19 using the same segmentation decoder and training protocol. SOAR achieves the highest mean Dice score of 0.897, compared with 0.726 for MAE, 0.663 for CLIP, 0.681 for fVLM, 0.837 for ViSD, and 0.868 for VoCo.\n\n> **W5** No statistical significance for ablation results. ......\n\nWe appreciate this suggestion. We performed paired t-tests on the per-example open-ended VQA scores and added the results to the original Table 3 of the manuscript. As shown in the table below, full SOAR significantly outperforms the ablated models on most metrics.\n\nNumbers in parentheses indicate the number of masked organs used during pretraining. Superscripts report paired t-test significance against the full SOAR model in the last row: \\*p<0.05$, \\**p<0.005, and \\***p<0.00005.\n\n| Organ-level reconstruction (# masked organs) | Organ-level supervision | Organ-conditioned mask tokens | Organ-level alignment | Multiple-choice accuracy (%) | BLEU-1 | BLEU-2 | ROUGE-1 | METEOR | BERT-F1 | GREEN |\n|:---:|:---:|:---:|:---:|---:|---:|---:|---:|---:|---:|---:|\n| ✓ (10) | | | | 84.44 | 48.37$^{***}$ | 37.25$^{***}$ | 53.57$^{***}$ | 50.46$^{***}$ | 91.86$^{***}$ | 45.44$^{***}$ |\n| ✓ (30) | | | | 88.64 | 48.88$^{***}$ | 38.02$^{*}$ | 54.36$^{***}$ | 50.76$^{***}$ | 91.94$^{***}$ | 46.53$^{**}$ |\n| ✓ (60) | | | | 85.79 | 48.16$^{***}$ | 37.63$^{***}$ | 53.82$^{***}$ | 50.46$^{***}$ | 91.86$^{***}$ | 46.37$^{***}$ |\n| ✓ (30) | ✓ | | | 89.37 | 49.05$^{**}$ | 38.17 | 54.56 | 50.88$^{***}$ | 91.92$^{***}$ | 46.22$^{***}$ |\n| ✓ (30) | ✓ | ✓ | | 89.63 | 48.78$^{***}$ | 37.94$^{**}$ | 54.24$^{***}$ | 50.71$^{***}$ | 91.90$^{***}$ | 46.14$^{***}$ |\n| ✓ (30) | ✓ | ✓ | ✓ | **89.87** | **49.27** | **38.19** | **54.65** | **51.15** | **92.00** | **46.83** |\n\n> **W6** It is unclear whether their in-house esophageal cancer screening dataset will be release to the public.\n\nThe in-house esophageal cancer screening dataset was obtained under a data transfer agreement with the providing hospital. It can be made available to qualified researchers through a standard and straightforward data transfer agreement process. We will clarify this procedure in the revised Data Availability statement and release our pretrained weights and source code.\n\n> **W7** SOAR depends heavily on TotalSegmentator, .... It is therefore inherently limited to CT (and MR) images.\n\nWe respectfully clarify that SOAR is not inherently tied to TotalSegmentator. It serves only as an offline pseudo-label generator and can be replaced by any compatible anatomical segmentation model without modifying SOAR’s architecture or objectives. Therefore, developing or using a particular state-of-the-art segmentation architecture is not a prerequisite of SOAR.\n\nWe selected TotalSegmentator because it is a mature and widely adopted community tool. According to its paper, it was validated on heterogeneous routine clinical CT data spanning different scanners, sites, protocols, body regions, and major pathologies. Importantly, its documented training data exclude CT-RATE, whereas CADS [5] was trained on 3,134 CT-RATE volumes, creating potential data overlap.\n\nFinally, the present work is intentionally scoped to 3D CT understanding, as explicitly stated in the title; extending SOAR to other modalities remains future work."
+ },
+ "createdAt": "2026-07-28T11:42:33.058Z",
+ "modifiedAt": "2026-11-18T17:17:12.439Z",
+ "url": "https://openreview.net/forum?id=xwakWJUI55&noteId=rJXX7eSqB6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xwakwjui55/notes/snh2yc6ijy.json added

+++ b/reviews/openreview/xwakwjui55/notes/snh2yc6ijy.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "Snh2YC6IJY",
+ "replyTo": "MoVIKHiVuE",
+ "kind": "comment",
+ "invitation": "Rebuttal",
+ "signature": "Authors",
+ "content": {
+ "rebuttal": "Dear Reviewer ZNxd, we sincerely thank you for your thoughtful and constructive feedback. We address each point below.\n\n> **W1**: The degree of technical novelty remains somewhat unclear: The method mainly combines organ-guided masking, regional feature aggregation, contrastive learning, and auxiliary segmentation at the organ level. ......\n\nWe thank you for requesting clearer positioning. SOAR's technical novelty lies in reformulating 3D CT pretraining around fine-grained organs as the fundamental supervision units. Specifically, it combines organ-level masking with organ-conditioned tokens, report-free organ-level vision-language alignment, and voxel-level anatomical supervision to jointly learn structural and semantic representations. Unlike MAE, CLIP, and VoCo, SOAR explicitly models organ identity; unlike fVLM and ViSD, it preserves the original 117-class anatomical granularity without paired reports or organ grouping. The following table presents the systematic comparison to clarify these distinctions, which will be added to the revised manuscript.\n\n**Table: Systematic comparison with closely related 3D CT pretraining methods.** Unlike fVLM and ViSD, which merge fine-grained structures into broader report-aligned regions, SOAR retains the original 117-class anatomical granularity without requiring paired reports. Performance below SOAR is averaged across all 41 metrics in the manuscript.\n| Method | Anatomical granularity | Language supervision | Paired reports needed | Performance Compared with SOAR (%) |\n|---|---|---|---|---|\n| MAE | None | None | No | −4.07% |\n| CLIP | Global | Whole radiology report | Yes | −5.69% |\n| fVLM | Coarse anatomical groups | Report-derived regional text | Yes | −5.18% |\n| ViSD | Coarse anatomical groups | Report-derived regional text | Yes | −7.41% |\n| VoCo | Spatial context | None | No | −4.41% |\n| **SOAR** | **117 fine-grained structures** | **Organ-name embeddings** | **No** | **Reference** |\n\n> **W2** The role of the external segmentation prior is not sufficiently disentangled: ......\n\nThank you for identifying the need to better disentangle the external segmentation prior. We have added three additional experiments to address your concerns.\n\n**Segmentation-only baseline.** To isolate the contribution of segmentation pretraining alone, we evaluated the pretrained TotalSegmentator encoder using the same VQA, disease-screening, and abnormality-detection protocols as the other encoders (Table A). SOAR outperforms this baseline on every metric, including +2.75 points in closed-ended VQA, +1.60–7.30 points across open-ended VQA metrics, +3.20 points in pneumonia AUC, and +6.78 points in CT-RATE abnormality AUC. Thus, SOAR's gains cannot be attributed solely to representations inherited from segmentation pretraining; the proposed organ-aware objectives substantially improve transfer to downstream CT-understanding tasks.\n\n**Robustness to noisy pseudo-labels.** We retrained SOAR with partially corrupted organ masks. Pneumonia average AUC decreases from 97.99 to 87.15, and CT-RATE abnormality AUC from 75.38 to 68.13 (Table B). This result supports SOAR's motivation that accurate organ masks establish explicit correspondences between local visual regions and organ identities, enabling fine-grained anatomical representation learning. The degradation under corrupted masks confirms that SOAR benefits from meaningful anatomical priors rather than arbitrary structured masking.\n\n**Masking-ratio control.** We would like to note that the 60-organ setting in Table 3 (in the paper) provides an approximate masking-ratio control for MAE. Across 1,500 sampled volumes, masking 60 organs produces a mean patch-masking ratio of 79.10% (range: 47.39%–94.97%; standard deviation: 7.75%), close to MAE's fixed 75% ratio. At this comparable ratio, the improvement over MAE is substantially smaller (85.79% vs. 85.76% accuracy; 46.37 vs. 46.18 GREEN score). This is expected because selecting more organs masks most of the volume, making organ masking increasingly similar to MAE's random masking. Among the evaluated settings, masking 30 organs achieves the best results, with 88.64% accuracy and 46.53 GREEN score.\n\n**Table A: Comparison between the TotalSegmentator encoder and SOAR across CT-RATE VQA, pneumonia classification, and CT-RATE abnormality detection.** Classification results are reported as AUC (%). For each task, both encoders are evaluated under the same downstream protocol. Δ denotes the improvement of SOAR over TotalSegmentator.\n\n| Benchmark | Task/Class | Metric | TotalSegmentator | **SOAR** | Δ |\n|---|---|---|---|---|---|\n| CT-RATE VQA | Closed-ended VQA | Accuracy (%) | 87.12 | **89.87** | ↑2.75 |\n| CT-RATE VQA | Open-ended VQA | BLEU-1 | 41.97 | **49.27** | ↑7.30 |\n| CT-RATE VQA | Open-ended VQA | BLEU-2 | 33.20 | **38.19** | ↑4.99 |\n| CT-RATE VQA | Open-ended VQA | ROUGE-1 | 49.76 | **54.65** | ↑4.89 |\n| CT-RATE VQA | Open-ended VQA | METEOR | 46.67 | **51.15** | ↑4.48 |\n| CT-RATE VQA | Open-ended VQA | BERT-F1 | 90.40 | **92.00** | ↑1.60 |\n| Pneumonia classification | COVID-19 | AUC (%) | 93.95 | **98.79** | ↑4.84 |\n| Pneumonia classification | Common Pneumonia | AUC (%) | 94.27 | **97.47** | ↑3.20 |\n| Pneumonia classification | Normal | AUC (%) | 96.16 | **97.72** | ↑1.56 |\n| Pneumonia classification | Average | AUC (%) | 94.79 | **97.99** | ↑3.20 |\n| CT-RATE abnormality | Average | AUC (%) | 68.60 | **75.38** | ↑6.78 |\n\n**Table B: Robustness analysis under distorted organ masks.** All results are AUC (%). The distorted-mask model is pretrained using corrupted pseudo-segmentation masks. Δ denotes the improvement of SOAR over the distorted-mask model.\n\n| Benchmark | Task/Class | Distorted masks | **SOAR** | Δ |\n|---|---|---|---|---|\n| Pneumonia classification | COVID-19 | 87.58 | **98.79** | ↑11.21 |\n| Pneumonia classification | Common Pneumonia | 83.55 | **97.47** | ↑13.92 |\n| Pneumonia classification | Normal | 90.32 | **97.72** | ↑7.40 |\n| Pneumonia classification | Average | 87.15 | **97.99** | ↑10.84 |\n| CT-RATE abnormality | Average | 68.13 | **75.38** | ↑7.25 |\n\n> **W3** The strength of the results and the scope of generalization remain limited: ...... \n\nWe thank you for raising this concern. Across Tables 1–2, SOAR is best or tied on 36 of 41 reported metrics, including all primary or aggregate measures. Where it ranks second, the differences are marginal (e.g., $0.11$ BLEU-2 and $0.07$ METEOR).\n\nAlthough CT-RATE primarily contains chest CT, SOAR’s visual representations generalize well to AMOS-MM, an abdominal CT benchmark. SOAR achieves $75.38\\%$ average accuracy, outperforming VoCo, ViSD, and fVLM by $4.55$, $5.41$, and $5.45$ percentage points, respectively. We further highlight three representative non-chest abdominal examples below. SOAR correctly identifies the absence of abnormalities in the upper abdomen and normal bilateral adrenal glands, whereas the comparison methods hallucinate unsupported findings. SOAR also precisely localizes a renal lesion to the upper pole of the right kidney, whereas the comparison methods predict the wrong structure, laterality, renal pole, or only coarse kidney localization. These quantitative and qualitative results provide direct evidence of transfer beyond chest CT. Due to limited space, additional examples will be added in the revised manuscript.\n\n### Representative abdominal VQA examples\n\n**Bold** denotes correct information, whereas $\\underline{\\text{underlining}}$ denotes incorrect or unsupported information.\n\n| Case | Entry | Question, reference answer, or model output |\n|:---|:---|:---|\n| Upper abdomen | Question | What is observed in the upper abdomen sections? |\n| | Ground truth | No feature was observed in the upper abdomen sections. |\n| | MAE | A $\\underline{3\\,\\mathrm{mm}\\text{ diameter calculus}}$ is observed in the upper pole of the left kidney. |\n| | CLIP | A $\\underline{16\\,\\mathrm{mm}\\text{ diameter nodular lesion}}$ is observed in the left adrenal gland, which is evaluated in favor of adenoma. |\n| | fVLM | A $\\underline{2\\,\\mathrm{mm}\\text{ diameter calculus}}$ is observed in the middle part of the left kidney. |\n| | VoCo | A $\\underline{3\\,\\mathrm{mm}\\text{ diameter calculus}}$ is observed in the middle zone of the left kidney. |\n| | ViSD | A $\\underline{2\\,\\mathrm{mm}\\text{ diameter calculus}}$ was observed in the upper pole of the left kidney. |\n| | **SOAR (Ours)** | **No features were detected in the upper abdomen sections.** |\n| Adrenal glands | Question | What type of changes were observed in the bilateral adrenal glands? |\n| | Ground truth | Bilateral adrenal gland calibration was normal. |\n| | MAE | $\\underline{\\text{Diffuse thickening}}$ was observed in the bilateral adrenal glands. |\n| | CLIP | $\\underline{\\text{Diffuse thickening}}$ was observed in both adrenal glands. |\n| | fVLM | $\\underline{\\text{Diffuse thickening}}$ was observed in the bilateral adrenal glands. |\n| | VoCo | $\\underline{\\text{Nodular thickening}}$ was observed in the bilateral adrenal glands. |\n| | ViSD | $\\underline{\\text{Diffuse thickening}}$ was observed in both adrenal glands. |\n| | **SOAR (Ours)**| **Bilateral adrenal glands were normal**, and no space-occupying lesion was detected. |\n| Renal lesion | Question | Where is the hypodense, well-circumscribed lesion located? |\n| | Ground truth | Upper pole of the right kidney. |\n| | MAE | $\\underline{\\text{Lower pole}}$ of the **right kidney**. |\n| | CLIP | $\\underline{\\text{Left kidney}}$. |\n| | fVLM | **Right kidney**. |\n| | VoCo | $\\underline{\\text{Left adrenal gland}}$. |\n| | ViSD | **Right kidney**. |\n| | **SOAR (Ours)** | **Right kidney upper pole.** |"
+ },
+ "createdAt": "2026-07-28T10:41:20.905Z",
+ "modifiedAt": "2026-11-18T17:17:11.333Z",
+ "url": "https://openreview.net/forum?id=xwakWJUI55&noteId=Snh2YC6IJY",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xwakwjui55/notes/vrv7gye29a.json added

+++ b/reviews/openreview/xwakwjui55/notes/vrv7gye29a.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "VRv7GYe29A",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "The proposal of SOAR—to inject organ-level anatomical priors into 3D CT visual representation learning—and its core motivation of alleviating the semantic mismatch between sparse diagnostic-report supervision and dense 3D CT anatomical information, received unanimous recognition from the three reviewers. However, the reviewers' scores diverged significantly (4: Borderline Accept, 5: Accept, 2: Reject), reflecting deep-seated disagreements over the paper's technical rigor and experimental completeness. One reviewer explicitly pointed out that SOAR should not be categorized as a self-supervised method, since it relies on pseudo-labels generated by TotalSegmentator as supervisory signals, which is fundamentally different from truly self-supervised pre-training approaches such as MAE. Therefore, the authors must supplement fair comparisons with supervised pre-training baselines (e.g., MedVAE, Foundation VAEs, pre-trained segmentation model encoders); otherwise, the baseline selection suffers from serious unfairness. In addition, two reviewers jointly noted critical omissions in the ablation study: the paper does not perform independent on/off ablations for each loss component, making it impossible to assess the necessity and individual contribution of each component. Moreover, a comparison between PubMedBERT embeddings and simple fixed class tokens is missing, which is essential to support the claimed technical contribution of \"organ-level visual-language alignment.\" Regarding the evaluation scope, two reviewers pointed out that the current qualitative examples are overly focused on the lungs, the pre-training data is limited to non-contrast chest CTs, and fine-grained downstream tasks such as segmentation and detection are absent—all of which weaken the generalizability evidence for the claimed \"organ-aware\" capability. Another reviewer also noted potential class imbalance in the organ labels and suggested supplementing organ-coverage statistics. The reviewers also raised concerns about the availability of the internal dataset, which affects result reproducibility. Overall, SOAR's core idea demonstrates clear problem awareness and application potential. However, the current version has substantive deficiencies in terms of method positioning accuracy, fairness of baseline comparisons, completeness of ablation designs, and systematic analysis of dependence on external segmentation priors. The experimental evidence is not yet sufficient to fully support its core claims. Therefore, my inclination is toward the borderline of acceptance, and the final decision is left to the SAC.",
+ "final_justification": ""
+ },
+ "createdAt": "2026-09-24T11:21:21.852Z",
+ "modifiedAt": "2026-11-18T14:55:27.811Z",
+ "url": "https://openreview.net/forum?id=xwakWJUI55&noteId=VRv7GYe29A",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xwakwjui55/notes/wx0hvbdawv.json added

+++ b/reviews/openreview/xwakwjui55/notes/wx0hvbdawv.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "WX0HvbdAwV",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer Vm6a",
+ "content": {
+ "summary": "The paper presents SOAR, a novel pretraining framework for 3D CT image understanding that incorporates automatically generated organ masks as fine-grained anatomical priors. Its motivation is clear: conventional CLIP-style vision-language pretraining is often too coarse for 3D CT, as it aligns whole volumes with sparse diagnostic reports and provides limited supervision for local anatomical structures. To address this issue, SOAR integrates organ-level masked reconstruction, organ-level vision-language alignment, and auxiliary organ segmentation supervision. Experiments on VQA, report generation, and abnormality detection across multiple medical imaging benchmarks show consistent improvements over recent baselines, while ablation studies further validate the effectiveness of its key components.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths \n\n- The paper is easy to follow and addresses an important and timely problem in 3D medical imaging.\n- The proposed method is novel, intuitive, and clinically grounded, effectively incorporating anatomical structures into medical vision pretraining.\n- The authors conduct broad and diverse evaluations across multiple datasets and downstream tasks, together with well-designed ablation studies, to demonstrate the effectiveness of the proposed framework and validate the contribution of each component.\n\nWeaknesses\n\n- The organ-level vision-language alignment mainly uses organ-name prompts rather than disease-aware or finding-aware text. This design is effective for anatomical grounding, but it may not fully capture fine-grained pathological semantics.\n- The pretraining data are mainly chest and abdominal CT from CT-RATE. The organ labels could be highly imbalanced. Reporting organ coverage statistics would help clarify the robustness of the organ-level objectives.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 4,
+ "originality": 4,
+ "questions": "See Weaknesses.",
+ "limitations": "Yes.",
+ "rating": 6,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "No.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "I remain convinced of the novelty and feasibility of the proposed framework and appreciate that the authors have clearly explained its key details. I strongly support acceptance of this paper."
+ },
+ "createdAt": "2026-06-25T04:57:47.178Z",
+ "modifiedAt": "2026-11-18T13:40:01.571Z",
+ "url": "https://openreview.net/forum?id=xwakWJUI55&noteId=WX0HvbdAwV",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/xwakwjui55/submission.json added

+++ b/reviews/openreview/xwakwjui55/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "xwakWJUI55",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 16216,
+ "url": "https://openreview.net/forum?id=xwakWJUI55",
+ "license": "CC-BY-4.0"
+}

versions/v_ukuyuadd.json added

+++ b/versions/v_ukuyuadd.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-05-03",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 16216,
+ "url": "https://openreview.net/forum?id=xwakWJUI55",
+ "reviews": "openreview/xwakwjui55",
+ "evidence": [
+ "https://openreview.net/forum?id=xwakWJUI55"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=xwakWJUI55",
+ "evidence": [
+ "https://openreview.net/forum?id=xwakWJUI55"
+ ]
+}