potentialpaper

UltraVoxelGS: Voxel-First Feed-Forward Gaussian Splatting for 3D Ultrasound Reconstruction

Import NeurIPS 2026 submission Jo1hZK6YQ8: 5 notes

@openreview[bot] · 2026-11-22 17:55 UTC · 0f8c635ca7f4 ·

Evidence

reviews/openreview/jo1hzk6yq8/forms.json added

+++ b/reviews/openreview/jo1hzk6yq8/forms.json
@@ -0,0 +1,227 @@
+{
+ "schema": "forms/1",
+ "forms": {
+ "Meta_Review": {
+ "label": "Meta-review",
+ "fields": [
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ }
+ ]
+ },
+ "Decision": {
+ "label": "Decision",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "hidden": true
+ },
+ {
+ "key": "decision",
+ "label": "Decision",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ },
+ {
+ "key": "metareview",
+ "label": "Meta-review",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Comment": {
+ "label": "Comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Public_Comment": {
+ "label": "Public comment",
+ "fields": [
+ {
+ "key": "title",
+ "label": "Title",
+ "type": "choice"
+ },
+ {
+ "key": "comment",
+ "label": "Comment",
+ "type": "text"
+ }
+ ]
+ },
+ "Withdrawal": {
+ "label": "Withdrawal",
+ "fields": [
+ {
+ "key": "withdrawal_confirmation",
+ "label": "Confirmation",
+ "hidden": true
+ }
+ ]
+ },
+ "Desk_Rejection": {
+ "label": "Desk rejection",
+ "fields": [
+ {
+ "key": "desk_reject_comments",
+ "label": "Reason",
+ "type": "text"
+ }
+ ]
+ },
+ "Official_Review": {
+ "label": "Official review",
+ "summary": [
+ "rating",
+ "confidence",
+ "quality",
+ "clarity",
+ "significance",
+ "originality"
+ ],
+ "fields": [
+ {
+ "key": "rating",
+ "label": "Rating",
+ "type": "score",
+ "min": 1,
+ "max": 6
+ },
+ {
+ "key": "confidence",
+ "label": "Confidence",
+ "type": "score",
+ "min": 1,
+ "max": 5
+ },
+ {
+ "key": "quality",
+ "label": "Quality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "clarity",
+ "label": "Clarity",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "significance",
+ "label": "Significance",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "originality",
+ "label": "Originality",
+ "type": "score",
+ "min": 1,
+ "max": 4
+ },
+ {
+ "key": "contribution_type",
+ "label": "Contribution type",
+ "type": "choice"
+ },
+ {
+ "key": "summary",
+ "label": "Summary",
+ "type": "text"
+ },
+ {
+ "key": "strengths_and_weaknesses",
+ "label": "Strengths and weaknesses",
+ "type": "text"
+ },
+ {
+ "key": "questions",
+ "label": "Questions",
+ "type": "text"
+ },
+ {
+ "key": "limitations",
+ "label": "Limitations",
+ "type": "text"
+ },
+ {
+ "key": "final_justification",
+ "label": "Final justification",
+ "type": "text"
+ },
+ {
+ "key": "paper_formatting_concerns",
+ "label": "Formatting concerns",
+ "type": "text"
+ },
+ {
+ "key": "ethical_concerns",
+ "label": "Ethical concerns",
+ "type": "choice"
+ },
+ {
+ "key": "code_of_conduct_acknowledgement",
+ "label": "Code of conduct",
+ "hidden": true
+ },
+ {
+ "key": "responsible_reviewing_acknowledgement",
+ "label": "Responsible reviewing",
+ "hidden": true
+ }
+ ]
+ },
+ "Rebuttal": {
+ "label": "Rebuttal",
+ "fields": [
+ {
+ "key": "rebuttal",
+ "label": "Rebuttal",
+ "type": "text"
+ }
+ ]
+ },
+ "Ethics_Review": {
+ "label": "Ethics review",
+ "fields": [
+ {
+ "key": "scope_of_ethics_concerns",
+ "label": "Scope",
+ "type": "choice"
+ },
+ {
+ "key": "ethics_review",
+ "label": "Ethics review",
+ "type": "text"
+ }
+ ]
+ }
+ },
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/6zwl9zlla6.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/6zwl9zlla6.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "6zwl9ZLLa6",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer wZmx",
+ "content": {
+ "summary": "This paper proposes a feed-forward Gaussian-splatting framework for 3D freehand ultrasound reconstruction. It lifts all posed 2D slices into a shared voxel support via local inverse-distance interpolation, then predicts voxel-aligned Gaussian primitives from per-target local sub-volumes. Rendering uses a Decoupled Reflection-and-Attenuation (DRA) model (SH reflection × cumulative attenuation), plus a test-time Render-time Appearance Adaptation (RAA) that fine-tunes appearance parameters against the nearest observed slice. On a real robotic lumbar-spine dataset and a simulated liver dataset, it reports the best PSNR/SSIM/LPIPS among the chosen baselines while reducing reconstruction from $\\approx$10-20 min to $\\approx$10 s.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "Strengths:\n- The paper observes that ultrasound slices share only line-like intersections and are view-dependent, invalidating the assumptions of optical feed-forward GS; decoupling representation size from input count via a shared voxel support is a sensible response.\n- The method demonstrates long-sequence scalability (Table 3), and the runtime breakdown (Table 6) is specific.\nWeakness:\n- From a general 3D vision / feed-forward Gaussian Splatting perspective, the core components (voxel-grid interpolation, Transformer-based primitive prediction, and test-time fine-tuning) represent an incremental combination of existing architectures tailored to a specific domain, rather than a broad algorithmic breakthrough for general scene representation.\n- As a general feed-forward submission, the paper should include feed-forward 3DGS baselines (e.g., VolSplat) to isolate what the proposed architecture contributes over existing general feed-forward paradigms.\n- The headline claim (feed-forward matching per-scene optimization) is carried by RAA, a test-time per-view optimization. Per Table 2, FF+DRA reaches only 19.76 PSNR, below 3DGS (22.55) and UltraGauss (22.06), and RAA alone adds +4.53 dB to 24.29, at 2.63 s/view. This is in tension with the \"feed-forward, real-time\" framing; Table 1 should report results without RAA.\n- \"over 60× faster\" (abstract) vs \"over 10× speedup\" (§1), pick one and define the reference.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 2,
+ "originality": 2,
+ "questions": "- Please report Table 1 results without RAA. Since FF+DRA reaches only 19.76 PSNR (below 3DGS and UltraGauss), how does the pure feed-forward path compare to the optimization baselines?\n- RAA is a 50-step per-view optimization at 2.63 s/view. How is the \"real-time\" claim justified, and how does it differ from a short per-scene optimization?\n- Would a more expressive support (ACORN, hash-grid, or TensoRF) preserve the detail lost by voxel interpolation and reduce reliance on RAA?\n- Can you add a feed-forward baseline (e.g., VolSplat) to isolate the ultrasound-specific contribution?",
+ "limitations": "N/A. It is in the appendix.",
+ "rating": 5,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "N/A",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "My major concerns regarding the performance, feed-forward baselines, and ablation study have been successfully resolved. The provided w/o RAA ablation also clarifies the role of appearance adaptation across different pose densities. Overall, the updated paper is technically solid with convincing experiments, justifying a higher score."
+ },
+ "createdAt": "2026-06-23T13:17:13.041Z",
+ "modifiedAt": "2026-11-18T13:40:02.833Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=6zwl9ZLLa6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/ahvp2rdgsp.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/ahvp2rdgsp.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "aHVP2RDGsp",
+ "replyTo": null,
+ "kind": "meta_review",
+ "invitation": "Meta_Review",
+ "signature": "Area Chair LYbU",
+ "content": {
+ "metareview": "Summary: the overall initial consensus leans positive, with reviewers finding the core idea technically sound and well-supported.\nMain strengths: problem formulation is well motivated, proposed method is effective on real and simulated dataset with faster reconstruction times.\nMain weaknesses: questions regarding the RAA module in evaluation should be further clarified, and lack of discussion on practical clinical use case and dataset consideration."
+ },
+ "createdAt": "2026-07-22T01:00:14.664Z",
+ "modifiedAt": "2026-11-18T15:21:49.973Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=aHVP2RDGsp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/tyobywlzs7.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/tyobywlzs7.json
@@ -0,0 +1,19 @@
+{
+ "schema": "review/1",
+ "id": "TYOBywLzs7",
+ "replyTo": null,
+ "kind": "decision",
+ "invitation": "Decision",
+ "signature": "Program Chairs",
+ "content": {
+ "title": "Paper Decision",
+ "decision": "Accept (poster)",
+ "comment": "",
+ "metareview": "Summary: the overall initial consensus leans positive, with reviewers finding the core idea technically sound and well-supported.\nMain strengths: problem formulation is well motivated, proposed method is effective on real and simulated dataset with faster reconstruction times.\nMain weaknesses: questions regarding the RAA module in evaluation should be further clarified, and lack of discussion on practical clinical use case and dataset consideration.",
+ "final_justification": "I have read the authors' response and agree with the reviewers' comments that it successfully addressed the issues raised in my initial meta-review. My final recommendation is accept."
+ },
+ "createdAt": "2026-09-24T11:21:22.782Z",
+ "modifiedAt": "2026-11-18T14:55:28.290Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=TYOBywLzs7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/v9k1fuatal.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/v9k1fuatal.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "V9k1fuaTAl",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer cGgJ",
+ "content": {
+ "summary": "The paper introduces UltraVoxelGS, a 3D ultrasound reconstruction framework that generates fast volumetric reconstructions and physically realistic renderings from 2D ultrasound scans. The method incorporates ultrasound-specific physical properties, including attenuation, reflection, and scattering, into the rendering process. The authors evaluate the method against several baselines and report improved reconstruction/rendering quality, particularly in SSIM, along with substantially faster reconstruction times. Qualitative results also suggest visually impressive 3D reconstructions.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "This paper addresses an important technical challenge in ultrasound imaging: reconstructing 3D volumetric information from 2D ultrasound acquisitions. The proposed UltraVoxelGS framework is technically interesting because it incorporates ultrasound-specific imaging physics, including attenuation, reflection, and scattering, into the rendering process rather than treating ultrasound as a generic image reconstruction problem. This is a meaningful strength and improves the relevance of the method for ultrasound data.\n\nThe manuscript is generally well written and easy to follow. The literature review includes relevant prior work, and the experimental results are promising. The reported improvements in SSIM over the evaluated baselines are significant, and the qualitative results are visually impressive. Another important strength is the substantial reduction in reconstruction time compared with baseline methods, which is highly relevant if the long-term goal is real-time or near-real-time 3D ultrasound visualization.\n\nHowever, the clinical motivation needs to be clarified. Not every ultrasound application requires 3D reconstruction from 2D scans. In some domains, such as echocardiography, dedicated 3D probes are already available, while in many other applications 2D ultrasound remains the standard clinical workflow. The paper would be stronger if it clearly identified the intended clinical use case. For example, extended field-of-view ultrasound for scoliosis monitoring, long-bone fracture assessment, thyroid imaging, or other anatomy-specific applications could provide clearer motivation for why 3D reconstruction from 2D ultrasound is clinically necessary.\n\nA related limitation is the lack of discussion of existing industry solutions. Commercial approaches already exist for 3D reconstruction from 2D ultrasound acquisitions, such as PIUR Imaging. The paper should explain how UltraVoxelGS differs from these systems, what limitations it overcomes, and why the proposed method would be clinically or technically advantageous. This is difficult to evaluate without a clearer clinical focus.\n\nThe description of live 3D reconstruction during acquisition is also unclear. It is not evident how the system can provide a live 3D view before the acquisition is complete. If the goal is sparse acquisition followed by 3D rendering, this should be stated clearly. If instead the method is intended to reconstruct during scanning and guide the operator toward poorly reconstructed regions, then the paper should describe how this feedback is provided. This is especially important because the introduction suggests novice users may struggle with freehand scanning. Without explicit real-time feedback, it is unclear how a novice user would know where to move the probe to improve missing or low-quality regions. The authors should also discuss whether such an interactive workflow could increase total scan time compared with conventional approaches.\n\nA major weakness is that 3D reconstruction accuracy is not directly evaluated. The paper reports image similarity metrics and qualitative visualizations, but it remains unclear whether the reconstructed 3D anatomy is geometrically accurate. For clinical applications, geometric fidelity may be as important as visual realism. The authors should include or discuss metrics that assess 3D spatial accuracy, such as landmark error, surface distance, volumetric overlap, or comparison against ground-truth 3D ultrasound, CT, MRI, or tracked acquisition data where available.\n\nAnother important concern is the nature of Dataset B. Since Dataset B is acquired using a robotic ultrasound system and the authors simulate the data by selecting certain frames, this does not represent a true freehand ultrasound acquisition as illustrated in Figure 1. For a proof-of-concept study this may be acceptable, but the manuscript should avoid describing this as “real-world” freehand acquisition unless actual freehand data are used. The absence of validation on true freehand ultrasound data limits confidence in the practical applicability of the method.\n\nOverall, UltraVoxelGS presents a technically promising and visually impressive framework for fast 3D ultrasound reconstruction. Its incorporation of ultrasound imaging physics and its reconstruction speed are important strengths. However, the paper would benefit from a clearer clinical use case, comparison or discussion relative to existing commercial 3D ultrasound reconstruction systems, direct evaluation of 3D geometric accuracy, and validation on true freehand ultrasound acquisitions.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 2,
+ "questions": "What is the primary clinical application targeted by UltraVoxelGS? The paper would benefit from a clearer motivation for why 3D reconstruction from 2D ultrasound is needed in the selected use case.\n\nHow does UltraVoxelGS differ from existing commercial 2D-to-3D ultrasound reconstruction solutions, such as PIUR Imaging? Please clarify what technical or clinical limitation the proposed method overcomes.\n\nHow is live 3D reconstruction intended to work during acquisition? Is the method reconstructing from sparse views after acquisition, or does it provide real-time feedback to guide the operator toward missing or poorly reconstructed regions?\n\nHow would a novice user know where to move the probe to improve the reconstruction? If real-time guidance is part of the intended workflow, the paper should describe the feedback mechanism and whether this affects total scan time.\n\nCan the authors evaluate 3D geometric reconstruction accuracy? Metrics such as landmark error, surface distance, volume overlap, or comparison against a tracked/freehand ground truth would strengthen the validation.\n\nWhy was the method not validated on true freehand ultrasound data? Since Dataset B is acquired using a robotic ultrasound system and then subsampled, it may not represent the challenges of actual freehand scanning.\n\nCan the authors revise the terminology around Dataset B? Since the data are simulated from robotic acquisition, describing this as real-world freehand ultrasound reconstruction may be misleading.",
+ "limitations": "no i have questions and also see the weakness part",
+ "rating": 5,
+ "confidence": 5,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "no concerns",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "All my comments have been clearly addressed. The most important inclusion is the addition of the new true freehand ultrasound evaluation (Dataset C). I strongly suggest that the authors include this new experiment in the final camera-ready version. The work will generate important discussions during the meeting. I have upgraded my score to accept"
+ },
+ "createdAt": "2026-06-11T16:47:44.835Z",
+ "modifiedAt": "2026-11-18T13:40:05.111Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=V9k1fuaTAl",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/vzzzsyru0b.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/vzzzsyru0b.json
@@ -0,0 +1,32 @@
+{
+ "schema": "review/1",
+ "id": "VzZzsYRu0B",
+ "replyTo": null,
+ "kind": "review",
+ "invitation": "Official_Review",
+ "signature": "Reviewer 21Lz",
+ "content": {
+ "summary": "The paper introduces UltraVoxelGS, a method for reconstructing 3D ultrasound from posed 2D ultrasound sequences. It lifts slices into a shared voxel support, predicts voxel-aligned Gaussian primitives from local slab regions, and renders target views with a decoupled reflection/attenuation model. A render-time appearance adaptation step refines transient appearance parameters using a nearby observed slice. Experiments on real robotic ultrasound and simulated liver ultrasound report improved held-out slice reconstruction and faster reconstruction than per-scene optimization baselines.",
+ "contribution_type": "general",
+ "strengths_and_weaknesses": "The voxel-first formulation is well motivated by the limited slice overlap and view-dependent appearance of ultrasound. The method combines shared voxel support construction, local Gaussian prediction, and ultrasound-aware rendering in a technically coherent way. The real-data results and long-sequence scalability analysis are practically relevant.\n\nThe main concern is that the largest quality gain comes from Render-time Appearance Adaptation: in the ablation, PSNR rises from 19.76 without RAA to 24.29 with RAA on Dataset A. This makes the \"feed-forward\" and \"real-time\" framing somewhat dependent on how per-view adaptation cost is counted. The evaluation also focuses on held-out slice reconstruction rather than direct 3D anatomical accuracy, diagnostic utility, or scan-guidance performance. Since the real dataset uses healthy lumbar spine robotic scans, the generality to broader freehand ultrasound, pose noise, device shift, and pathology remains uncertain.",
+ "quality": 3,
+ "clarity": 3,
+ "significance": 3,
+ "originality": 3,
+ "questions": "1. Please report total runtime including RAA for realistic numbers of rendered target views.\n\n2. How does RAA performance vary with distance or angle between the target pose and the nearest observed anchor slice?\n\n3. Please add controlled pose-noise experiments, since the method depends on accurate tracking.\n\n4. Can the authors evaluate 3D geometry or scan-guidance quality beyond held-out slice PSNR/SSIM/LPIPS?\n\n5. For simulated data, can attenuation/reflection components be quantitatively compared with simulator references?",
+ "limitations": "The limitations section is useful and covers tracking accuracy, sparse coverage, shadowing, simplified physics, and lack of clinical validation. It should also state more directly that the main evaluation is held-out slice reconstruction and that RAA adds per-view optimization.",
+ "rating": 5,
+ "confidence": 3,
+ "ethical_concerns": [
+ "NO or VERY MINOR ethics concerns only"
+ ],
+ "paper_formatting_concerns": "Minor language and spacing issues are present.",
+ "code_of_conduct_acknowledgement": "Yes",
+ "responsible_reviewing_acknowledgement": "Yes",
+ "final_justification": "The rebuttal resolved my main concerns through a clear runtime-quality breakdown, an evaluated streaming implementation, repeated pose-noise experiments, and additional Dataset C and anatomical-consistency results. The authors also appropriately distinguished real-time direct rendering from the slower, higher-quality RAA mode and agreed to revise the claims. RAA still introduces per-view optimization, and clinical validation remains limited, but these limitations are now clearly characterized and are outweighed by the method’s technical contribution and strengthened empirical evidence. I therefore recommend acceptance."
+ },
+ "createdAt": "2026-06-26T08:59:53.364Z",
+ "modifiedAt": "2026-11-18T13:40:00.789Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=VzZzsYRu0B",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/submission.json added

+++ b/reviews/openreview/jo1hzk6yq8/submission.json
@@ -0,0 +1,12 @@
+{
+ "schema": "submission/1",
+ "id": "Jo1hZK6YQ8",
+ "venue": {
+ "id": "NeurIPS.cc/2026/Conference",
+ "name": "NeurIPS 2026",
+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"
+ },
+ "number": 16273,
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8",
+ "license": "CC-BY-4.0"
+}

versions/v_zrcb8tbw.json added

+++ b/versions/v_zrcb8tbw.json
@@ -0,0 +1,22 @@
+{
+ "date": "2026-05-03",
+ "kind": "submitted",
+ "label": "NeurIPS 2026",
+ "submissions": [
+ {
+ "venue": "NeurIPS 2026",
+ "status": "accepted",
+ "decision": "Accept (poster)",
+ "number": 16273,
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8",
+ "reviews": "openreview/jo1hzk6yq8",
+ "evidence": [
+ "https://openreview.net/forum?id=Jo1hZK6YQ8"
+ ]
+ }
+ ],
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8",
+ "evidence": [
+ "https://openreview.net/forum?id=Jo1hZK6YQ8"
+ ]
+}