potentialpaper

UltraVoxelGS: Voxel-First Feed-Forward Gaussian Splatting for 3D Ultrasound Reconstruction

Update NeurIPS 2026 submission Jo1hZK6YQ8: 16 notes

@openreview[bot] · 2026-11-24 15:49 UTC · 58649d767d1e ·

Evidence

reviews/openreview/jo1hzk6yq8/notes/0ztlbu64yj.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/0ztlbu64yj.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "0ZtlBU64yJ",
+ "replyTo": "CPDkhTpXS6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you very much for your constructive feedback and valuable suggestions. We will incorporate the corresponding modifications and additional results into the revised manuscript. We sincerely appreciate your time and effort."
+ },
+ "createdAt": "2026-08-04T06:44:43.681Z",
+ "modifiedAt": "2026-11-19T17:07:54.046Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=0ZtlBU64yJ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/5wzclxlpfw.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/5wzclxlpfw.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "5WzclXlPFW",
+ "replyTo": "JeSlQCS0H3",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**Q1. Runtime clarification paired with quality.**\n\nThe gap between the appendix (0.18 s, 2.63 s/view) and this rebuttal (3.62 ms, 623 ms/view) stems from the **rendering-stage** implementation-level engineering changes only. The reconstruction pipeline, hardware, training stage and evaluation protocol are all unchanged (V100, same data and metrics). \n\nA key distinction motivates these changes. During *reconstruction*, global context is essential: voxel compounding aggregates all input frames, and the voxel-to-Gaussian network processes the full volume to produce the Gaussian scene. However, once reconstruction is complete, all global information has already been encoded into *local* Gaussian primitives. During *rendering*, each Gaussian contributes to a pixel only when that pixel falls within the primitive's $3\\\\sigma$ support, so a Gaussian whose $3\\\\sigma$ extent does not reach the queried plane contributes nothing to that view. Because Gaussian scales are bounded during training, the $3\\\\sigma$ extent of the largest admissible Gaussian is bounded as well; we therefore define a slab whose half-thickness exceeds this bound, guaranteeing that every primitive able to reach the queried plane is retained. Excluding the remaining distant, non-contributing Gaussians is thus *lossless by construction*. \n\nTwo factors contribute to the speedup. First, the originally reported time redundantly reloaded the full Gaussian scene from CPU to GPU memory on every rendered view. Second, slab filtering as described above excludes the distant, non-contributing Gaussians, substantially reducing the number of primitives evaluated during rasterization.\n\nFor *direct rendering*, removing the redundant reload and applying slab filtering bring the per-view cost from 0.18 s to 3.62 ms (rasterization 2.53 ms + filtering 1.09 ms). For *RAA*, we additionally restrict optimization to the local slab rather than the full scene, reducing the per-view cost from 2.63 s to 623 ms while preserving the same 50-iteration refinement objective. As a result, the outputs are *identical* to those reported in the submission, because the speedups remove only redundant I/O and zero-contribution primitives. As summarized in Table 1, each runtime is paired with its corresponding quality.\n\nApart from this, we note that the w/o-RAA PSNR is reported as 19.87 dB in the supplementary material, which is a typographical error; the correct value, consistent with the main text, is 19.76 dB (SSIM 0.5770, LPIPS 0.5130). We will correct this in the revision.\n\n*Table 1: Per-view runtime paired with the quality (Dataset A).*\n\n$$\n\\\\begin{array}{llcccc}\n\\\\hline\n\\\\text{Mode} & \\\\text{Setting} & \\\\text{Time/view} & \\\\text{PSNR}\\\\uparrow & \\\\text{SSIM}\\\\uparrow & \\\\text{LPIPS}\\\\downarrow \\\\\\\\\n\\\\hline\n\\\\text{w/o RAA} & \\\\text{reported} & 180\\\\ \\\\text{ms} & 19.76 & 0.5770 & 0.5130 \\\\\\\\\n& \\\\text{ours} & 3.62\\\\ \\\\text{ms} & 19.76 & 0.5770 & 0.5130 \\\\\\\\\n\\\\hline\n\\\\text{RAA50} & \\\\text{reported} & 2630\\\\ \\\\text{ms} & 24.29 & 0.8329 & 0.2384 \\\\\\\\\n& \\\\text{ours} & 623\\\\ \\\\text{ms} & 24.29 & 0.8329 & 0.2384 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\n**Q2. Clarification about highest quality**\n\n**We agree that the highest reconstruction quality is obtained by the RAA mode rather than the direct real-time mode; this is a deliberate design choice rather than a limitation.** The two modes serve different clinical needs: the *direct rendering* mode supports real-time browsing and navigation during scanning ($3.62$ ms/view), while the *RAA* mode supports sub-second, high-fidelity inspection ($623$ ms/view) once the operator has located a clinically relevant plane. We will revise our claims accordingly."
+ },
+ "createdAt": "2026-08-02T08:42:36.289Z",
+ "modifiedAt": "2026-11-19T17:07:54.568Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=5WzclXlPFW",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/abkczjj9kw.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/abkczjj9kw.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "aBKCZjJ9kW",
+ "replyTo": "EARPv1NBMr",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 21Lz",
+ "content": {
+ "comment": "Thank you for the comprehensive clarification. The revised runtime-quality breakdown clearly distinguishes real-time direct rendering from the higher-quality RAA mode and adequately explains the timing discrepancy. The streaming evaluation, repeated pose-noise experiments, corrected characterization of the SAM2 analysis, and Dataset C results further strengthen the work. These responses address my remaining concerns."
+ },
+ "createdAt": "2026-08-03T03:42:24.392Z",
+ "modifiedAt": "2026-11-19T17:07:54.145Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=aBKCZjJ9kW",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/ahvp2rdgsp.json modified

+++ b/reviews/openreview/jo1hzk6yq8/notes/ahvp2rdgsp.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair LYbU",
"content": {
- "metareview": "Summary: the overall initial consensus leans positive, with reviewers finding the core idea technically sound and well-supported.\nMain strengths: problem formulation is well motivated, proposed method is effective on real and simulated dataset with faster reconstruction times.\nMain weaknesses: questions regarding the RAA module in evaluation should be further clarified, and lack of discussion on practical clinical use case and dataset consideration."
+ "metareview": "Summary: the overall initial consensus leans positive, with reviewers finding the core idea technically sound and well-supported.\nMain strengths: problem formulation is well motivated, proposed method is effective on real and simulated dataset with faster reconstruction times.\nMain weaknesses: questions regarding the RAA module in evaluation should be further clarified, and lack of discussion on practical clinical use case and dataset consideration.",
+ "final_justification": "I have read the authors' response and agree with the reviewers' comments that it successfully addressed the issues raised in my initial meta-review. My final recommendation is accept."
},
"createdAt": "2026-07-22T01:00:14.664Z",
- "modifiedAt": "2026-11-18T15:21:49.973Z",
+ "modifiedAt": "2026-11-19T05:01:06.790Z",
"url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=aHVP2RDGsp",
"license": "CC-BY-4.0"
}

reviews/openreview/jo1hzk6yq8/notes/b26wy5rxwx.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/b26wy5rxwx.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "B26WY5RXwX",
+ "replyTo": "HeNQbwxiOJ",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**Q5. Is the reconstructed 3D anatomy consistent?**\n\nWe add a 3D anatomical geometry evaluation on Dataset B, where the CT-derived liver segmentation provides the reference anatomy. For each sequence, we use the CT-derived mask on an observed anchor frame as the mask prompt to initialize the same frozen SAM2 model, and propagate the mask to the novel views rendered by each method. The predicted 2D masks are then lifted using their corresponding poses and fused into a 3D anatomical mask and mesh. Because all methods use identical SAM2 initialization and fusion protocol, differences in 3D Dice/IoU are attributable to the geometric and appearance fidelity of each method's rendered views. As shown in Table 1, UltraVoxelGS achieves the best 2D Dice, 3D Dice, and 3D IoU among all evaluated methods, demonstrating superior preservation of 3D anatomical geometry. \n\nThis 3D geometry evaluation also directly relates to scan-guidance quality. In practice, scan guidance requires identifying which anatomical regions remain insufficiently covered. Given a more geometrically faithful reconstruction, the operator can reliably compare the reconstructed liver volume against the expected anatomy and localize regions with missing or degraded coverage. UltraVoxelGS therefore enables more trustworthy scan guidance.\n\n*Table 1: Segmentation-based 3D anatomical consistency (volume overlap) on Dataset B.*\n\n$$\n\\\\begin{array}{lccc}\n\\\\hline\n\\\\text{Method} & \\\\text{2D Dice}\\uparrow & \\\\text{3D Dice}\\uparrow & \\\\text{3D IoU}\\uparrow \\\\\\\\\n\\\\hline\n\\\\text{UltraVoxelGS} & \\\\mathbf{0.8469} & \\\\mathbf{0.8787} & \\\\mathbf{0.7866} \\\\\\\\\n\\\\text{3DGS} & 0.7441 & 0.8593 & 0.7557 \\\\\\\\\n\\\\text{ImplicitVol} & 0.6419 & 0.7283 & 0.5758 \\\\\\\\\n\\\\text{UltraGauss} & 0.5153 & 0.6802 & 0.5188 \\\\\\\\\n\\\\text{Kernel interpolation} & 0.6937 & 0.7683 & 0.6277 \\\\\\\\\n\\\\text{Ultra-NeRF} & 0.5215 & 0.5776 & 0.4115 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\n**Q6. Validation on true handheld freehand ultrasound.**\n\nWe first correct the dataset description: Dataset A was acquired using a robotic ultrasound system and then temporally subsampled, whereas Dataset B is simulated liver ultrasound data.\n\nRegarding temporal subsampling, Table 3 already evaluates the effect of decreasing the sampling stride: performance does not degrade as the input becomes denser (the $2\\times$ setting contains over 1,600 frames), confirming that subsampling is not masking a difficulty. It is also computationally necessary, since per-scene optimization on the full-density input can exceed one hour, which is impractical for real-world use. \n\nWe acknowledge that robotic and handheld acquisitions differ in trajectory characteristics. To directly evaluate the handheld setting, we test the trained model on tracked-handheld Dataset C---paired with Dataset A but differing in acquisition trajectory---without retraining and under the same protocol as Dataset A (Table 2). No baseline is optimized for this handheld setting, yet UltraVoxelGS remains close to its own robotic performance and still outperforms the per-scene UltraGauss, confirming that it generalizes to the more complex trajectories of real-world handheld scanning.\n\n*Table 2: Performance on dataset A and dataset C.*\n\n$$\n\\\\begin{array}{lccc}\n\\\\hline\n\\\\text{Setting} & \\\\text{PSNR}\\uparrow & \\\\text{SSIM}\\uparrow & \\\\text{LPIPS}\\downarrow \\\\\\\\\n\\\\hline\n\\\\text{UltraGauss (Handheld acquisition)} & 20.05 & 0.5858 & 0.5580 \\\\\\\\\n\\\\text{UltraVoxelGS (Robotic acquisition)} & 24.29 & 0.8329 & 0.2384 \\\\\\\\\n\\\\text{UltraVoxelGS (Handheld acquisition)} & 23.96 & 0.7703 & 0.3356 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$"
+ },
+ "createdAt": "2026-07-31T10:45:52.055Z",
+ "modifiedAt": "2026-11-19T17:07:54.269Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=B26WY5RXwX",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/cpdkhtpxs6.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/cpdkhtpxs6.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "CPDkhTpXS6",
+ "replyTo": "EzNLHwocHz",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer wZmx",
+ "content": {
+ "comment": "Thank you for the detailed response and extensive additional experiments. My major concerns are resolved, and please ensure that all these modification and new experimental results are fully incorporated in the revised version. I will raise my score accordingly."
+ },
+ "createdAt": "2026-08-03T20:30:02.620Z",
+ "modifiedAt": "2026-11-19T17:07:54.086Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=CPDkhTpXS6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/djut3vixaf.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/djut3vixaf.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "DJut3VIxAf",
+ "replyTo": "6zwl9ZLLa6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**Q3. Discussion about expressive support and RAA**\n\nThe current voxel support is chosen for simplicity and interpretability. More adaptive representations (ACORN, hash-grid, or TensoRF) are valuable future extensions because their adaptive multi-resolution structures may preserve sharper local details during support construction.\n\nTo examine whether a sharper spatial support can reduce the effect of RAA, we increase the voxel resolution at inference time without changing the model or retraining it. As shown in Table 3, the denser support provides a modest improvement for UltraVoxelGS w/o RAA, but increases the Gaussian count from approximately 38.0M to 90.5M. Meanwhile, the complete UltraVoxelGS (w/ RAA) still achieves substantially better performance.\n\nThese results suggest that exploring more adaptive and expressive supports is valuable because they can further strengthen the proposed framework. However, stronger spatial support does not replace RAA for two reasons. First, representations such as ACORN or hash grids mainly improve spatial compression and resolution, but do not explicitly address how to preserve direction-dependent appearance under ultrasound anisotropy. Second, consolidating many frame-specific observations into a structured global support inevitably discards some local appearance details unless the compression is entirely lossless. RAA therefore remains necessary to compensate for these lost query-specific details.\n\n*Table 3: Expressive support-density analysis.*\n\n$$\n\\\\begin{array}{llccc}\n\\\\hline\n\\\\text{Support resolution} & \\\\text{Method} & \\\\text{PSNR}\\uparrow & \\\\text{SSIM}\\uparrow & \\\\text{LPIPS}\\downarrow \\\\\\\\\n\\\\hline\n0.75\\ \\\\text{mm} & \\\\text{UltraVoxelGS w/o RAA} & 19.76 & 0.5770 & 0.5130 \\\\\\\\\n0.75\\ \\\\text{mm} & \\\\text{UltraVoxelGS} & \\\\mathbf{24.29} & \\\\mathbf{0.8329} & \\\\mathbf{0.2384} \\\\\\\\\n0.50\\ \\\\text{mm} & \\\\text{UltraVoxelGS w/o RAA} & 20.14 & 0.5909 & 0.4719 \\\\\\\\\n0.50\\ \\\\text{mm} & \\\\text{UltraVoxelGS} & 24.22 & 0.8200 & \\\\mathbf{0.2131} \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\n**Q4. Isolate ultrasound-specific contribution**\n\nWe agree that it is necessary to isolate the ultrasound-specific contribution of UltraVoxelGS using a generic feed-forward GS baseline. However, directly applying VolSplat to long ultrasound sequences is computationally impractical because its native formulation jointly processes a limited number of input views before lifting their features into a 3D feature space and decoding the scene.\n\nWe therefore adapt VolSplat to our long-sequence setting while preserving its original training paradigm. During training, randomly sampled source views are used as input, their features are lifted into a 3D feature space, and the complete scene is decoded. During inference, we divide all source views into groups, process each group independently to obtain lifted 3D features, fuse the features from all groups into a common global feature space, and decode the scene representation once. This allows VolSplat to use the full source sequence.\n\nThe results on Dataset A are shown in Table 4. UltraVoxelGS w/o RAA substantially outperforms the adapted VolSplat baseline. This gap reflects the distinct reconstruction paradigms. VolSplat must process limited view subsets independently, losing the global scene context and making it difficult to aggregate information distributed across different subset views. In contrast, UltraVoxelGS first consolidates the complete sequence into a unified 3D support and then predicts Gaussians only from the view-interacted local regions. Owing to ultrasound thin-slab locality, each such local region contains the relevant context from the globally constructed support without requiring repeated whole-scene decoding. The result therefore supports the contribution of the ultrasound-specific voxel-first formulation and local-to-global reconstruction strategy.\n\n*Table 4: Feed-forward comparison on Dataset A.*\n\n$$\n\\\\begin{array}{llccc}\n\\\\hline\n\\\\text{Method} & \\\\text{Regime} & \\\\text{PSNR}\\uparrow & \\\\text{SSIM}\\uparrow & \\\\text{LPIPS}\\downarrow \\\\\\\\\n\\\\hline\n\\\\text{VolSplat} & \\\\text{Feed-forward} & 15.70 & 0.4522 & 0.5884 \\\\\\\\\n\\\\text{UltraVoxelGS w/o RAA} & \\\\text{FF + DRA} & 19.76 & 0.5770 & 0.5130 \\\\\\\\\n\\\\text{UltraVoxelGS} & \\\\text{FF + DRA + RAA} & 24.29 & 0.8329 & 0.2384 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\n**Q5. Speedup Clarification**\n\nThe earlier \"over $60\\times$\" and \"over $10\\times$\" statements used different references and were ambiguous. We now use a single, explicitly defined comparison: UltraVoxelGS constructs the global 3D representation in\n$10.2$ s, approximately $35\\times$ faster than the fastest per-scene optimization baseline (ImplicitVol, $5.95$ min)."
+ },
+ "createdAt": "2026-07-31T10:31:34.610Z",
+ "modifiedAt": "2026-11-19T17:07:54.335Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=DJut3VIxAf",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/earpv1nbmr.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/earpv1nbmr.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "EARPv1NBMr",
+ "replyTo": "EmHTt5iNCH",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**Q4. Update of pose noise experiment.**\n\nTo address the reviewer's specific questions: (1) perturbations are sampled independently per frame for each translational and rotational axis; (2) we originally reported a single realization and now re-run with three independent random seeds to verify stability and reproducibility. As shown in Table 3, the results are highly stable (PSNR std $\\\\le 0.10$ dB) confirming that the conclusions from our initial response are not artifacts of a particular noise realization.\n\n*Table 3: Reproducibility of controlled pose experiment on dataset B.*\n\n$$\n\\\\begin{array}{cclccc}\n\\\\hline\n\\\\sigma_t\\\\ (\\\\text{mm}) & \\\\sigma_r\\\\ ({}^\\\\circ) & \\\\text{Condition} & \\\\text{PSNR}\\\\uparrow & \\\\text{SSIM}\\\\uparrow & \\\\text{LPIPS}\\\\downarrow \\\\\\\\\n\\\\hline\n0 & 0 & \\\\text{A} & 20.86 & 0.3158 & 0.6206 \\\\\\\\\n\\\\hline\n8 & 4 & \\\\text{B} & 20.92 \\\\pm 0.01 & 0.3177 \\\\pm 0.0001 & 0.6199 \\\\pm 0.0001 \\\\\\\\\n& & \\\\text{C} & 20.11 \\\\pm 0.08 & 0.3017 \\\\pm 0.0015 & 0.6336 \\\\pm 0.0013 \\\\\\\\\n& & \\\\text{D} & 19.92 \\\\pm 0.08 & 0.2985 \\\\pm 0.0016 & 0.6384 \\\\pm 0.0043 \\\\\\\\\n\\\\hline\n12 & 6 & \\\\text{B} & 20.87 \\\\pm 0.10 & 0.3165 \\\\pm 0.0027 & 0.6232 \\\\pm 0.0052 \\\\\\\\\n& & \\\\text{C} & 19.62 \\\\pm 0.01 & 0.2920 \\\\pm 0.0007 & 0.6423 \\\\pm 0.0004 \\\\\\\\\n& & \\\\text{D} & 19.48 \\\\pm 0.03 & 0.2900 \\\\pm 0.0002 & 0.6448 \\\\pm 0.0016 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\n**Q5. Anatomical consistency (SAM2).**\n\nWe agree this should be described as **segmentation-based anatomical consistency** rather than a direct measurement of Gaussian geometry, and will revise the wording accordingly.\n\n**Q6. Dataset C (tracked-handheld) --- actual numbers.**\n\nWithout retraining, our method on handheld acquisition stays close to robotic acquisition and clearly surpasses the UltraGauss optimization baseline, supporting robustness to trajectory change and pose noise. \n\n*Table 4: Subject-level macro-average on robotic and tracked-handheld (Dataset C) test cases.*\n\n$$\n\\\\begin{array}{lccc}\n\\\\hline\n\\\\text{Setting} & \\\\text{PSNR}\\\\uparrow & \\\\text{SSIM}\\\\uparrow & \\\\text{LPIPS}\\\\downarrow \\\\\\\\\n\\\\hline\n\\\\text{UltraGauss (Handheld / Dataset C)} & 20.05 & 0.5858 & 0.5580 \\\\\\\\\n\\\\text{UltraVoxelGS (Robotic acquisition)} & 24.29 & 0.8329 & 0.2384 \\\\\\\\\n\\\\text{UltraVoxelGS (Handheld / Dataset C)} & 23.96 & 0.7703 & 0.3356 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$"
+ },
+ "createdAt": "2026-08-02T08:47:04.182Z",
+ "modifiedAt": "2026-11-19T17:07:54.148Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=EARPv1NBMr",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/emhtt5inch.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/emhtt5inch.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "EmHTt5iNCH",
+ "replyTo": "5WzclXlPFW",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "**Q3. Streaming reconstruction.**\n\nThe core contribution of our method is a voxel-first *paradigm* for ultrasound reconstruction, and the main paper deliberately instantiates it as a single-pass support construction over the full sequence, the setting in which the paradigm is cleanly presented and evaluated. As a natural extension, we have implemented and evaluated Streaming/periodic reconstruction, which we will include in the appendix of the revised paper.\n\nIn streaming reconstruction, for each voxel $\\\\mathbf{x}$ we maintain two persistent fusion accumulators, the weighted numerator $A(\\\\mathbf{x})$ and denominator $W(\\\\mathbf{x})$:\n\n$$\nA_t(\\\\mathbf{x}) = \\\\sum \\\\omega_{i,p}(\\\\mathbf{x})\\\\,I_i(p), \\\\qquad W_t(\\\\mathbf{x}) = \\\\sum \\\\omega_{i,p}(\\\\mathbf{x}),\n$$\n\nwhere the summation aggregates the contributions of all frames processed so far. When a new chunk of frames arrives, they add their contributions $(\\\\Delta A_t, \\\\Delta W_t)$ only to the voxels they affect, and the voxel intensity is the updated ratio:\n\n$$\nA_{t+1} = A_t + \\\\Delta A_t, \\\\qquad W_{t+1} = W_t + \\\\Delta W_t, \\\\qquad V_{t+1}(\\\\mathbf{x}) = \\\\frac{A_{t+1}(\\\\mathbf{x})}{W_{t+1}(\\\\mathbf{x}) + \\\\epsilon}.\n$$\n\nThis incremental fusion follows directly from Eq. 6. For the Gaussian stage, only the blocks whose voxel support has been updated by the current chunk, $\\\\mathcal{U}_t = \\\\{\\\\mathbf{x} \\\\mid \\\\Delta W_t(\\\\mathbf{x}) > 0\\\\}$, are re-processed by the voxel-to-Gaussian network, since these are the only blocks that have received new information; all remaining blocks keep their previous Gaussians unchanged:\n\n$$\nG_{t+1}^{b} = f(V_{t+1}^{b}), \\\\quad b \\\\in B_t.\n$$\n\n$$\n\\\\mathbf{G}_{t+1}^{b} = \\\\mathbf{G}_t^{b}, \\\\quad b \\\\notin \\\\mathcal{B}_t.\n$$\n\nWe evaluate the streaming mode in two ways. Compared with direct reconstruction, which builds the voxel support from the full sequence, generates the Gaussians block-wise, and evaluates all novel views at once, the two streaming settings proceed incrementally. In *progressive streaming*, every $L$ incoming frames update the current voxel support (following the equations above), and only the blocks whose support has changed are re-processed by the feed-forward model to refresh the corresponding Gaussians. Right after each update, we evaluate the novel views whose target planes fall within the spatial extent of the newly updated blocks; each novel view is evaluated exactly once, immediately after the update that covers it, using only the information available at that point.\n*Final streaming* shares this exact construction but evaluates all novel views once at the end, using the representation obtained after the full sequence is processed. \n\nIn streaming experiments we set the chunk size to $L=10$ frames. As shown in Table 2, both settings are comparable to direct reconstruction, confirming that the online paradigm is practical without sacrificing fidelity. Final streaming is slightly better than progressive streaming, as it evaluates every view using the complete sequence, whereas progressive streaming can only use the frames seen up to each point. Direct reconstruction performs slightly better than final streaming because the feed-forward model is trained under the direct (full-volume) setting; the streaming pipeline **reuses the same model without any retraining or fine-tuning**, so the minor gap is expected and reflects only the mismatch between training and inference procedures rather than a fundamental limitation of the streaming paradigm.\n\n*Table 2: Performance of streaming reconstruction on dataset A.*\n\n$$\n\\\\begin{array}{lccc}\n\\\\hline\n\\\\text{Setting} & \\\\text{PSNR}\\\\uparrow & \\\\text{SSIM}\\\\uparrow & \\\\text{LPIPS}\\\\downarrow \\\\\\\\\n\\\\hline\n\\\\text{Progressive streaming} & 24.08 & 0.8240 & 0.2555 \\\\\\\\\n\\\\text{Final streaming} & 24.11 & 0.8280 & 0.2476 \\\\\\\\\n\\\\text{Direct reconstruction} & \\\\mathbf{24.29} & \\\\mathbf{0.8329} & \\\\mathbf{0.2384} \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$"
+ },
+ "createdAt": "2026-08-02T08:46:42.241Z",
+ "modifiedAt": "2026-11-19T17:07:54.145Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=EmHTt5iNCH",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/eznlhwochz.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/eznlhwochz.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "EzNLHwocHz",
+ "replyTo": "6zwl9ZLLa6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the detailed questions regarding RAA, spatial support, feed-forward baselines, and runtime.\n\n**Q1.Table 1 report w/o RAA and comparison between feed-forward path and optimization baseline**\n\nWe add UltraVoxelGS w/o RAA (i.e. the feed-forward path with DRA only) to the main comparison table (Table 1). On Dataset B, the feed-forward prediction alone already matches the optimization-based baselines in PSNR; on Dataset A, however, it is noticeably weaker. We attribute this discrepancy to the different pose densities of the two datasets.\n\nOn Dataset A, the dense, closely-spaced poses cause interpolation to oversmooth fine structures and degrade the feed-forward prediction; as the dense acquisition also places anchors close to the target, RAA effectively recovers the lost detail, yielding a large gain of about 4 dB. On Dataset B, the sparse poses induce far less smoothing and the feed-forward prediction is already sharp, matching the other baselines; RAA still compensates for the residual interpolation-induced detail loss, contributing a smaller but still substantial gain of about 2 dB..\n\nOverall, the feed-forward pass and RAA are complementary: whenever interpolation smooths out detail, RAA restores it—decisively when the effect is severe (Dataset A) and as a consistent refinement when it is mild (Dataset B). RAA is thus an integral component, not an optional add-on, keeping UltraVoxelGS robust across acquisition densities.\n\n*Table 1: Quantitative comparison on real-world and simulated ultrasound datasets.*\n\n$$\n\\\\begin{array}{llccc|ccc}\n\\\\hline\n& & & \\\\text{Dataset A} & & & \\\\text{Dataset B} & \\\\\\\\\n\\\\text{Method} & \\\\text{Type} & \\\\text{PSNR}\\uparrow & \\\\text{SSIM}\\uparrow & \\\\text{LPIPS}\\downarrow & \\\\text{PSNR}\\uparrow & \\\\text{SSIM}\\uparrow & \\\\text{LPIPS}\\downarrow \\\\\\\\\n\\\\hline\n\\\\text{Kernel Interpolation} & \\\\text{Interpolation} & 13.52 & 0.3952 & 0.5419 & 17.47 & 0.2391 & 0.6259 \\\\\\\\\n\\\\text{ImplicitVol} & \\\\text{Per-scene optimization} & 19.13 & 0.6128 & 0.5218 & 18.97 & 0.2837 & 0.7192 \\\\\\\\\n\\\\text{UltraNeRF} & \\\\text{Per-scene optimization} & 18.49 & 0.4056 & 0.5761 & 17.75 & 0.1975 & \\\\mathbf{0.5985} \\\\\\\\\n\\\\text{3DGS} & \\\\text{Per-scene optimization} & 22.55 & 0.6695 & 0.3884 & 18.04 & 0.2532 & 0.6702 \\\\\\\\\n\\\\text{UltraGauss} & \\\\text{Per-scene optimization} & 22.06 & 0.6220 & 0.4750 & 15.01 & 0.1838 & 0.7057 \\\\\\\\\n\\\\text{UltraVoxelGS w/o RAA} & \\\\text{FF + DRA} & 19.76 & 0.5770 & 0.5130 & 18.25 & 0.2690 & 0.7860 \\\\\\\\\n\\\\text{UltraVoxelGS} & \\\\text{FF + DRA + RAA} & \\\\mathbf{24.29} & \\\\mathbf{0.8329} & \\\\mathbf{0.2384} & \\\\mathbf{20.87} & \\\\mathbf{0.3138} & 0.6190 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\n**Q2. Real-time justification and comparison about per-scene optimization**\n\nWe have optimized the rendering pipeline by removing Gaussians outside the queried slab before rasterization, exploiting ultrasound's thin-slice geometry.\nThe originally reported 2.63 s/view in Table 6 rasterized all Gaussians in the scene; slab-based culling removes over 99.4% of them as irrelevant to the queried slice, reducing rendering time to 2.53,ms/view for direct rendering and 623,ms/view with RAA, without affecting any quality metric.\nDirect rendering is real-time (2.53 ms); RAA is interactive (623 ms). Both suit the intended clinical workflow where an operator reviews reconstructed slices on demand.\n\nUnder this setting, RAA differs from short per-scene optimization in two aspects (shown in Table 2). First, they differ in *what is optimized*: RAA adapts transient appearance parameters while keeping the reconstructed geometry frozen, whereas per-scene optimization updates the full scene representation itself. Second, they differ in *how the cost scales*: RAA is a query-time refinement with a fixed per-query cost that is independent of the number of source views, whereas per-scene optimization scales with the length of the input sequence, making it ill-suited to long ultrasound acquisitions. Overall, RAA is not a shortened per-scene reconstruction but a query-time appearance adaptation, offering a more practical refinement strategy for interactive ultrasound inspection.\n\n*Table 2: Per-scene optimization versus RAA.*\n\n$$\n\\\\begin{array}{lll}\n\\\\hline\n\\\\text{Aspect} & \\\\text{Per-scene optimization} & \\\\text{RAA} \\\\\\\\\n\\\\hline\n\\\\text{Target} & \\\\text{Complete scene} & \\\\text{Current queried view} \\\\\\\\\n\\\\text{Updated variables} & \\\\text{Geometry and appearance} & \\\\text{Transient }\\rho,\\beta \\\\\\\\\n\\\\text{Global representation} & \\\\text{Optimized per scene} & \\\\text{Feed-forward and fixed} \\\\\\\\\n\\\\text{Scope} & \\\\text{Entire scene} & \\\\text{Query-relevant local support} \\\\\\\\\n\\\\text{Persistence} & \\\\text{Stored in the scene} & \\\\text{Discarded after rendering} \\\\\\\\\n\\\\text{Runtime} & \\\\text{Increases with scene scale and input views} & \\\\text{Independent of source views (623 ms / 50 steps)} \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$"
+ },
+ "createdAt": "2026-07-31T10:28:01.158Z",
+ "modifiedAt": "2026-11-19T17:07:54.373Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=EzNLHwocHz",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/henqbwxioj.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/henqbwxioj.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "HeNQbwxiOJ",
+ "replyTo": "V9k1fuaTAl",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the constructive suggestions and thoughtful comments on our method.\n\n**Q1. What is the primary clinical application?**\n\nUltraVoxelGS is a general ultrasound reconstruction framework rather than a method designed for a specific anatomical structure. We consider its primary clinical applications to be extended-field-of-view imaging and other static or near-static ultrasound examinations. Representative examples include scoliosis monitoring, long-bone fracture assessment, thyroid imaging, liver, and late-gestation fetal assessment. In these settings, a 3D anatomical representation can provide important diagnostic value, while the native field of view of a dedicated 3D probe may be insufficient to cover the entire region of interest. UltraVoxelGS is not restricted to a fixed 3D probe acquisition volume; instead, its reconstructed field of view can expand with the trajectory of a conventional 2D ultrasound sweep. Moreover, since it requires only a conventional 2D probe, it avoids the additional cost and specialized hardware of dedicated 3D transducers, improving clinical accessibility. \n\nOur experiments demonstrate this capability in two extended-field-of-view settings: Dataset A, consisting of real-world robot-assisted lumbar-spine ultrasound sequences with tracked probe poses, and Dataset B, consisting of simulated liver ultrasound sequences generated from abdominal CT volumes.\nWe will strengthen the clinical motivation in the revised introduction accordingly.\n\n**Q2. How does UltraVoxelGS differ from PIUR and other commercial systems?**\n\nThe key difference lies in the underlying scene representation. UltraVoxelGS uses a direction-aware Gaussian representation, which allows it to model ultrasound-specific appearance factors such as anisotropic reflection and cumulative attenuation. This representation better accommodates flexible scanning trajectories, including local revisits and changes in scanning direction.\n\nIn contrast, many conventional or commercial reconstruction systems form an isotropic voxel volume by lifting registered 2D slices into 3D space and compounding their intensities, producing a tomographic-style representation similar to CT or MRI volumes. Such reconstruction commonly favors smooth, approximately uniform sweeps with limited dwelling or repeated sampling of the same region, because redundant observations are often averaged during voxel compounding, which may smooth local details. This can constrain the acquisition trajectory and, consequently, the applicable scanning scenarios.\n\nThis difference is particularly relevant near interfaces with large acoustic-impedance differences, where strong specular reflection or acoustic shadowing may hide structures from a single insonification direction. Additional observations from different probe directions can therefore be important. UltraVoxelGS is designed to preserve and render such direction-dependent observations within a unified representation rather than collapsing them into a single isotropic intensity value.\n\n**Q3--Q4. How do \"live\" reconstruction and visual feedback work?**\n\nReal-time scan guidance requires two capabilities: (i) fast 3D reconstruction and rendering that keeps pace with the ongoing scan, and (ii) a mechanism to identify under-reconstructed regions and translate them into actionable probe-pose suggestions. This work addresses capability (i). UltraVoxelGS enables a live reconstruction workflow: as the operator scans, the system simultaneously streams acquired frames into a voxel support and, at fixed intervals, generates local GS representations and fuses them into the global scene. This construction proceeds in the background, overlapping with the scan rather than waiting for it. When inspection is needed, the operator can render corresponding views in real time.\n\nRegarding capability (ii), reconstruction incompleteness is already visually observable in the rendered views (see Fig. 11), but it has not yet been converted into explicit guidance. One natural extension is to associate uncertainty with the Gaussian representation and compute a pose-dependent cumulative uncertainty score for candidate poses, directing the operator toward under-observed regions. Beyond visual inspection, the reconstructed scene also supports downstream analysis such as 3D segmentation (see Q5 below), which can further assist the operator in assessing anatomical coverage. These extensions are enabled by, and fundamentally depend on, the fast reconstruction and rendering prerequisite addressed in this work."
+ },
+ "createdAt": "2026-07-31T10:38:42.895Z",
+ "modifiedAt": "2026-11-19T17:07:54.597Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=HeNQbwxiOJ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/jeslqcs0h3.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/jeslqcs0h3.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "JeSlQCS0H3",
+ "replyTo": "VzZzsYRu0B",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 21Lz",
+ "content": {
+ "comment": "Thank you for the additional experiments; the anchor, pose-noise, anatomical-consistency, and attenuation analyses strengthen the evaluation. My main remaining concern is the runtime framing.\nThe submitted appendix reports 0.18 s/view without RAA and 2.63 s/view with RAA, whereas the rebuttal reports 2.53 ms and 623 ms. Please explain the implementation, hardware, or timing-protocol changes and pair each runtime with its corresponding quality. The submitted ablation shows 19.87 PSNR without RAA versus 24.29 with RAA, so the highest reported quality is not obtained by the direct real-time mode.\nPlease also clarify whether the claimed streaming/periodic reconstruction was implemented and evaluated or is only a proposed workflow, since the submitted method describes constructing the support from the input sequence. For pose noise, specify whether perturbations are independent per frame and how many realizations were used. The SAM2 experiment is useful but should be described as segmentation-based anatomical consistency rather than a direct measurement of Gaussian geometry. Please also include the actual Dataset C numbers. These clarifications will affect my final assessment."
+ },
+ "createdAt": "2026-08-01T05:56:14.215Z",
+ "modifiedAt": "2026-11-19T17:07:54.267Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=JeSlQCS0H3",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/pahweef1zl.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/pahweef1zl.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "PAhWEeF1zL",
+ "replyTo": "VzZzsYRu0B",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "### Q3. Controlled pose-noise experiments\n\nThe purpose of this experiment is to evaluate whether UltraVoxelGS remains stable when the input poses contain tracking errors. Since training data can be curated with offline pose refinement, we focus on the clinically relevant scenario of inference-time tracking noise. Pose information is used in three stages of our framework: constructing the global representation (fusion), selecting the observed anchor (anchor), and querying the target view (query).\n\nTo isolate the sensitivity of each stage, we decompose the effect across four conditions: (A) clean setting; (B) noisy poses are used only for scene fusion; (C) noisy poses are used for both scene fusion and anchor selection; and (D) noisy poses are used for all three stages. Specifically, we inject zero-mean Gaussian noise independently on each translational and rotational axis at two levels ($\\sigma_t=8$ mm/$\\sigma_r=4^\\circ$ and $\\sigma_t=12$ mm/$\\sigma_r=6^\\circ$; the latter corresponds to a realized 3-DoF RMS of $20.8$ mm/$10.3^\\circ$). As shown in Table 2, fusion is essentially unaffected (B remains at the clean-pose level, within run-to-run variation), and the degradation is concentrated in anchor selection, while target querying adds little. Notably, even under such large perturbations (realized RMS $20.8$ mm/$10.3^\\circ$), PSNR drops by only $\\sim$1.3 dB, demonstrating that UltraVoxelGS is robust to realistic tracking errors.\n\n*Table 2: Controlled pose-noise decomposition on Dataset B.*\n\n| Noise | Condition | PSNR$\\uparrow$ | SSIM$\\uparrow$ | LPIPS$\\downarrow$ |\n|---|---|---:|---:|---:|\n| Clean | A | 20.86 | 0.3158 | 0.6206 |\n| 8 mm/4$^\\circ$ | B | 20.93 | 0.3176 | 0.6199 |\n| | C | 20.20 | 0.3033 | 0.6322 |\n| | D | 19.86 | 0.2969 | 0.6372 |\n| 12 mm/6$^\\circ$ | B | 20.94 | 0.3181 | 0.6200 |\n| | C | 19.63 | 0.2925 | 0.6419 |\n| | D | 19.51 | 0.2900 | 0.6439 |\n\n### Q4. Evaluation of 3D geometry\n\nWe add a 3D anatomical geometry evaluation on Dataset B, where the CT-derived liver segmentation provides the reference anatomy. For each sequence, we use the CT-derived mask on an observed anchor frame as the mask prompt to initialize the same frozen SAM2 model, and propagate the mask to the novel views rendered by each method. The predicted 2D masks are then lifted using their corresponding poses and fused into a 3D anatomical mask and mesh. Because all methods use identical SAM2 initialization and fusion protocol, differences in 3D Dice/IoU are attributable to the geometric and appearance fidelity of each method's rendered views. As shown in Table 3, UltraVoxelGS achieves the best 2D Dice, 3D Dice, and 3D IoU among all evaluated methods, demonstrating superior preservation of 3D anatomical geometry. \n\nThe reconstructed 3D anatomical surface also offers a potential form of scan guidance: the operator can directly inspect whether the accumulated organ boundary is complete or exhibits gaps corresponding to under-scanned regions. A higher 3D Dice/IoU indicates that the reconstruction more faithfully preserves the true organ geometry, making such coverage gaps easier to identify and localize. UltraVoxelGS achieves the best scores on both metrics, suggesting it provides the most reliable geometric basis for this type of volumetric coverage feedback.\n\n*Table 3: Segmentation-based 3D anatomical consistency on Dataset B.*\n\n| Method | 2D Dice$\\uparrow$ | 3D Dice$\\uparrow$ | 3D IoU$\\uparrow$ |\n|---|---:|---:|---:|\n| UltraVoxelGS | **0.8469** | **0.8787** | **0.7866** |\n| 3DGS | 0.7441 | 0.8593 | 0.7557 |\n| ImplicitVol | 0.6419 | 0.7283 | 0.5758 |\n| UltraGauss | 0.5153 | 0.6802 | 0.5188 |\n| Kernel interpolation | 0.6937 | 0.7683 | 0.6277 |\n| Ultra-NeRF | 0.5215 | 0.5776 | 0.4115 |\n\n### Q5. Quantitative evaluation of learned physical components\n\nWe quantitatively compare the learned attenuation factor with the simulator attenuation reference on Dataset B: $\\mathrm{Pearson}=0.6966\\pm0.0259,\\quad \\mathrm{Spearman}=0.6699\\pm0.0331$. Compared with a depth-linear decay baseline, whose slope and intercept are least-squares fitted to the reference ($\\mathrm{Pearson}=0.6648$, $\\mathrm{Spearman}=0.6545$), our results confirm that the factorization captures non-trivial attenuation structure despite receiving no supervision.\n\nThe simulator does not provide an independent reference corresponding to the reflection component; Nonetheless, the qualitative visualization in Fig. 7 shows that the reflection component captures boundary structures consistent with tissue interfaces.\n\n### Q6. generality to broader freehand ultrasound,\n\nWe directly test our Dataset A–trained model on Dataset C, a paired handheld freehand dataset with a different acquisition trajectory. Without retraining, UltraVoxelGS still remains close to its own robotic performance (see cGgJ.Q6), indicating robustness to trajectory change and pose noise."
+ },
+ "createdAt": "2026-07-31T10:12:47.424Z",
+ "modifiedAt": "2026-11-19T17:07:54.525Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=PAhWEeF1zL",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/vvvqqm0skd.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/vvvqqm0skd.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "vvvQQM0SKd",
+ "replyTo": "VzZzsYRu0B",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the reviewer for the focused questions regarding RAA, evaluation, and the physical interpretation of the learned components.\n\n### Q1. Runtime including RAA\n\nIn the intended clinical workflow, reconstruction runs in the background during scanning: our method streams incoming frames into the voxel support and periodically fuses local GS representation into the global scene. The one-time global construction completes in 10.04s, which is well within typical scanning durations, so the representation is ready by the time the operator needs feedback, with no separate reconstruction wait.\n\nOnce the global scene is available, the operator-perceived latency per queried view has two modes: (1) direct free-viewpoint rendering at 2.53ms/view (real-time), sufficient for browsing; and (2) RAA-refined rendering at 623,ms/view (sub-second, interactive-rate) for a selected plane requiring physically faithful appearance. (Note: The 2.53ms/view and 623ms/view reflect removing Gaussians outside the queried slab before rasterization, which exploits ultrasound's thin-slice geometry. This does not affect any quality metric; we will update Table 6 accordingly in the revision.) Since construction is fully overlapped with scanning, the latency the operator perceives at inspection time is purely the rendering cost. For $K$ RAA-refined views, this is $T_{\\text{inspect}}(K)=\\underbrace{623}_{\\text{RAA}}\\times K$ ms\n, i.e., 6.23s for 10 planes, or 62.3s for 100 views. (Even without overlap, the one-time construction adds only 10s.)\n\nBy comparison, per-scene optimization baselines require around 10 minutes even on our $5\\times$ subsampled benchmark (approximately 600 frames, corresponding to only approximately 20 s of acquisition at 30 FPS), and their cost grows with input view count (potentially exceeding one hour on denser real-world acquisitions). For background reconstruction to be feasible, its latency must remain shorter than the scanning time; otherwise the representation is still unavailable when feedback is needed. These baselines cannot meet this constraint, making real-time guidance during scanning impractical.\n\n### Q2. RAA sensitivity to target--anchor spatial and angular discrepancy.\n\nTo analyze the sensitivity of RAA to pose variation, we rank all candidate anchors for each target view by either translational distance or rotational discrepancy, and apply RAA using anchors at different ranks (Top-1, Top-3, Top-5, and Top-10). As shown in Table 1, RAA maintains strong refinement within a small spatial and angular neighborhood, and although the benefit gradually decreases as the anchor's translational or rotational discrepancy grows, it consistently outperforms UltraVoxelGS w/o RAA even at Top-10.\n\nThese results support the design motivation of RAA. The feed-forward prediction provides a stable geometric representation, but voxel-interpolation may lead to locally smoothed reconstruction details. Inspired by ultrasound imaging physics, speckle structures preserve local acoustic continuity across neighboring observations. RAA leverages this continuity from nearby anchors to compensate for missing details in the target view while maintaining target-view's geometry. As the spatial or angular discrepancy increases, the local acoustic continuity gradually weakens, leading to reduced refinement benefits.\n\n*Table 1: RAA refinement under translation- and rotation-ranked anchors at different Top-$k$ ranks on Dataset B.*\n\n| Strategy | Anchor | Translation distance (mm) | Rotation angle ($^\\circ$) | PSNR$\\uparrow$ | SSIM$\\uparrow$ | LPIPS$\\downarrow$ |\n|---|---|---:|---:|---:|---:|---:|\n| UltraVoxelGS | Top-1 | $7.87\\pm3.52$ | $2.78\\pm2.31$ | 20.87 | 0.3138 | 0.6190 |\n| Translation | Top-3 | $14.09\\pm5.56$ | $5.16\\pm3.87$ | 19.89 | 0.2889 | 0.6919 |\n| | Top-5 | $19.09\\pm6.83$ | $6.80\\pm4.47$ | 19.39 | 0.2813 | 0.7018 |\n| | Top-10 | $28.86\\pm8.27$ | $10.28\\pm6.12$ | 18.76 | 0.2719 | 0.7136 |\n| Rotation | Top-3 | $16.98\\pm10.25$ | $4.11\\pm1.95$ | 19.91 | 0.2889 | 0.6922 |\n| | Top-5 | $22.24\\pm10.46$ | $5.59\\pm2.39$ | 19.41 | 0.2812 | 0.7020 |\n| | Top-10 | $34.32\\pm14.24$ | $8.45\\pm3.10$ | 18.68 | 0.2707 | 0.7156 |\n| UltraVoxelGS w/o RAA | - | - | - | 18.25 | 0.2690 | 0.7860 |"
+ },
+ "createdAt": "2026-07-31T10:06:14.880Z",
+ "modifiedAt": "2026-11-19T17:07:54.507Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=vvvQQM0SKd",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/yw88uljklq.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/yw88uljklq.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "YW88uLjKLQ",
+ "replyTo": "aHVP2RDGsp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We thank the AC for the constructive summary. Below we address the two flagged concerns and highlight additional experiments conducted during the rebuttal.\n\nFirst, regarding the **role of RAA**, our method supports two complementary modes: a direct mode for real-time browsing during scanning, and an RAA mode for sub-second, high-fidelity inspection of selected views. RAA complements rather than replaces the feed-forward reconstruction, compensating for residual details lost in voxel interpolation. As the two modes target different operating points (i.e., real-time browsing versus highest-fidelity inspection), we will make this distinction explicit in the revision. (see 21lz.Q1 and wZmx.Q1-Q3).\n\nSecond, regarding **clinical applicability and dataset considerations**, the primary motivation is extended-field 3D ultrasound imaging, and unlike existing commercial solutions, our direction-aware representation preserves view-dependent acoustic appearance for more flexible scanning. To further validate applicability under real-world deployment conditions, we provide freehand dataset evaluation (Dataset C) and controlled pose-noise experiments, demonstrating robustness under more realistic acquisition (see cGgJ.Q1-Q2, cGgJ.Q6-Q7, and 21lz.Q3). \n\nAdditionally, following reviewers' suggestions, we strengthen the paper in several directions. Regarding the intended **workflow and real-time capability**, reconstruction runs in the background during scanning: incoming frames are streamed into the voxel support and periodically fused into the global scene, making the reconstructed representation available in real time as scanning proceeds, so the operator can obtain feedback without any separate reconstruction step. We also implement and evaluate a streaming reconstruction variant demonstrating this workflow, and resolve a runtime discrepancy noted during review by applying a rendering-stage optimization that accelerates inference while leaving all quality metrics unchanged (see 21lz.Q1 and cGgJ.Q3-Q4). Regarding **volumetric reconstruction quality**, we additionally supplement a segmentation-based 3D anatomical consistency evaluation, demonstrating the superior anatomical geometry preservation of our method over baselines.(see 21lz.Q4 and cGgJ.Q5). Regarding **the ultrasound-specific contribution**, we additionally include a generic (physics-agnostic) baseline, demonstrating the benefit of our ultrasound physics modeling (see wZmx.Q4).\n\n\nWe hope these clarifications and experiments address the AC's and reviewers' concerns and strengthen our work."
+ },
+ "createdAt": "2026-08-04T11:58:12.988Z",
+ "modifiedAt": "2026-11-19T17:07:54.038Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=YW88uLjKLQ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jo1hzk6yq8/notes/zccbfpi0dg.json added

+++ b/reviews/openreview/jo1hzk6yq8/notes/zccbfpi0dg.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "ZccBfpi0dg",
+ "replyTo": "aBKCZjJ9kW",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you again for your insightful comments and constructive suggestions. They have greatly strengthened our work and helped us improve the clarity, completeness, and rigor of the paper. We sincerely appreciate your time and effort."
+ },
+ "createdAt": "2026-08-03T07:08:15.741Z",
+ "modifiedAt": "2026-11-19T17:07:54.329Z",
+ "url": "https://openreview.net/forum?id=Jo1hZK6YQ8&noteId=ZccBfpi0dg",
+ "license": "CC-BY-4.0"
+}