Tokenizer-Generator Coupling in Medical Image Generation
Keep the title, authors and abstract in paper.json
potentialpaper · 2026-11-23 20:43 UTC · 863a37a3e597 ·
.potentialpaper/metadata.json modified
+++ b/.potentialpaper/metadata.json@@ -1,21 +1,5 @@{- "layout": 5,- "identifiers": [- {- "scheme": "openreview",- "value": "xImy5OosQz"- }- ],- "title": "Tokenizer-Generator Coupling in Medical Image Generation",- "authors": [- "Liam Chalcroft"- ],- "abstract": "Latent generative models for medical images usually treat the tokenizer as a fixed preprocessing step, with evaluation focused on the generator. This separation was tested in a controlled ChestMNIST study at $64\\times64$ that crosses discrete tokenizers, generator families and sampler settings on a shared latent grid, alongside continuous-latent reference cells. Rankings were found to depend jointly on all three components, with the best quantizer changing with the generator, and the interaction held when the vocabulary-1024 block was retrained at three seeds, where 4 of 9 pairwise quantizer comparisons exceed three seed standard deviations, including a reversal between LFQ and FSQ from MaskGIT to D3PM. Reconstruction quality was not a reliable guide to generation quality. Sampler settings also changed the conclusions, since validation-selected retuning of D3PM and SEDD on LFQ-1024 reduced FID-192 from 0.44 and 0.41 to 0.09 and 0.10 at lower NFE, replicated across seeds, bringing both close to the strongest continuous references. FID-192 is used as an internal ranking metric and agrees with standard FID-2048 (Spearman 0.89) and with a label-free two-sample test (0.86). The results fit a rate-distortion-modelability tradeoff in which modelability depends on the generator, sampler and inference budget. The scope is limited to 54 discrete and 16 continuous cells on low-resolution medical-style images, with unconditional generation, non-clinical FID-based evaluation and single-seed training outside the seeded block.",- "year": 2026,- "venue": "NeurIPS 2026",- "source": "openreview",- "license": {- "metadata": "CC0-1.0",- "abstract": "CC0-1.0"- }+ "layout": 6,+ "kind": "paper",+ "key": "6dfa5565-2de0-46dd-9a5c-a5d1164b73d9"}
paper.json added
+++ b/paper.json@@ -0,0 +1,11 @@+{+ "title": "Tokenizer-Generator Coupling in Medical Image Generation",+ "authors": [+ "Liam Chalcroft"+ ],+ "abstract": "Latent generative models for medical images usually treat the tokenizer as a fixed preprocessing step, with evaluation focused on the generator. This separation was tested in a controlled ChestMNIST study at $64\\times64$ that crosses discrete tokenizers, generator families and sampler settings on a shared latent grid, alongside continuous-latent reference cells. Rankings were found to depend jointly on all three components, with the best quantizer changing with the generator, and the interaction held when the vocabulary-1024 block was retrained at three seeds, where 4 of 9 pairwise quantizer comparisons exceed three seed standard deviations, including a reversal between LFQ and FSQ from MaskGIT to D3PM. Reconstruction quality was not a reliable guide to generation quality. Sampler settings also changed the conclusions, since validation-selected retuning of D3PM and SEDD on LFQ-1024 reduced FID-192 from 0.44 and 0.41 to 0.09 and 0.10 at lower NFE, replicated across seeds, bringing both close to the strongest continuous references. FID-192 is used as an internal ranking metric and agrees with standard FID-2048 (Spearman 0.89) and with a label-free two-sample test (0.86). The results fit a rate-distortion-modelability tradeoff in which modelability depends on the generator, sampler and inference budget. The scope is limited to 54 discrete and 16 continuous cells on low-resolution medical-style images, with unconditional generation, non-clinical FID-based evaluation and single-seed training outside the seeded block.",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}