Tokenizer-Generator Coupling in Medical Image Generation
Update NeurIPS 2026 submission xImy5OosQz: 5 notes
@openreview[bot] · 2026-11-24 15:57 UTC · a8c1a2798421 ·
reviews/openreview/ximy5oosqz/notes/73ny6jd1pe.json added
+++ b/reviews/openreview/ximy5oosqz/notes/73ny6jd1pe.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "73NY6jD1PE",+ "replyTo": "YqfN40JeIO",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the careful reading and constructive comments. We used the discussion period to run additional experiments addressing the main points in the meta-review. Unless stated otherwise, the results below were obtained after submission.\n\nBoth concerns in the meta-review are fair. The observation that reconstruction quality does not predict generation quality is already established in natural-image work. We will cite that literature more directly and will not present this observation by itself as the novelty of the paper.\n\nOne new result from the discussion period is a generator-free analysis of the token fields. Reconstruction PSNR has Spearman correlation +0.01 with downstream generation quality. Marginal token entropy also does not separate the tokenizer families, with rank-AUC 0.50. This matters because marginal entropy was the explanation proposed in the submitted paper.\n\nNeighbour-conditional predictive gain performs better in this analysis. It measures how much knowing the token immediately to the left or above reduces uncertainty about the current token. Using smoothing selected on a validation split, it separates the three VQ tokenizers from the six LFQ and FSQ tokenizers with rank-AUC 1.00. There are only nine tokenizers, so we will report this as a small-sample result rather than a general law about tokenizer modelability. It nevertheless provides an intrinsic measurement that was absent from the submitted paper.\n\nThe other contribution is the interaction measured within the matched factorial. LFQ is best under AR and D3PM, while FSQ is best under MaskGIT. Sampler selection can also change the apparent ordering of generators. We are not aware of prior work that measures all of these factors together in the same controlled design, although the individual observations are clearly related to prior natural-image results.\n\nThe submitted paper used one training run per cell. We have now retrained the vocabulary-1024 block using seeds 42, 43, and 44, with all runs evaluated on the same GPU. Six of the nine pairwise quantizer comparisons are larger than three times the pooled standard deviation, including the comparisons that establish the quantizer–generator interaction. Three comparisons remain within seed variation, and we will not claim an ordering for them. The seeded evidence covers this block; the wider 18-cell grid remains single-seed.\n\nWe also compared FID-192 with standard FID-2048 using the same samples from 12 representative cells. Their Spearman correlation is 0.80, and they agree on the broad separation between good and poor models. A classifier two-sample test agrees with FID-192 at Spearman 0.78 and does not use Inception features or a Gaussian approximation.\n\nThis comparison showed that the claim in Appendix C that FID-2048 is degenerate at 64 x 64 is wrong. At 10,000 samples, the real-versus-real FID-2048 floor is 2.31, with no negative values across 20 resamples. We will correct this and describe FID-192 as a lower-dimensional internal metric whose broad ranking agrees with standard FID-2048.\n\nWe will also remove the suggestion that the PneumoniaMNIST reversal is explained by its smaller training set. When ChestMNIST is subsampled to 4,700 examples, LFQ+AR still outperforms VQ+AR, with FID-192 of 0.946 versus 2.023. LFQ remains better at every tested ChestMNIST size. This rules out the simple size explanation but does not identify what causes the reversal on PneumoniaMNIST.\n\nThe medical framing will be narrowed as well. The experiments use low-resolution medical-style images and do not test subtle clinical variation at higher resolution. The current evidence does not support claims about medical image generation in general.\n\nThe current generators are unconditional, so a direct synth-then-classify experiment would not be well defined because the generated images do not have pathology labels. We added a classifier two-sample test as a label-free comparison, but we will not present it as evidence of clinical utility. A proper downstream study would require pathology-conditional generation and valid labels.\n\nThe revised paper will therefore make a narrower claim than the submitted version. It provides a controlled study of quantizer, rate, generator, and sampler in low-resolution medical-image generation, shows that these choices interact within the seeded block, and reports an initial generator-free statistic associated with the observed tokenizer differences. The practical recommendation remains to evaluate the tokenizer together with the generator and sampler rather than selecting it from reconstruction quality alone.\n\nWe hope the additional seed, metric, and modelability analyses address the two reasons given against acceptance in the meta-review."+ },+ "createdAt": "2026-07-28T16:09:44.143Z",+ "modifiedAt": "2026-11-19T16:42:46.602Z",+ "url": "https://openreview.net/forum?id=xImy5OosQz¬eId=73NY6jD1PE",+ "license": "CC-BY-4.0"+}
reviews/openreview/ximy5oosqz/notes/c31qfwdbss.json added
+++ b/reviews/openreview/ximy5oosqz/notes/c31qfwdbss.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "c31qFwDbSs",+ "replyTo": "VKMimajjfs",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer GTqK",+ "content": {+ "title": "Answer to rebuttal",+ "comment": "Thank you for the detailed rebuttal. The multi-seed experiments mostly address my concern about whether the tokenizer generator interaction and the D3PM/SEDD tuning improvements are robust to seed variation. In particular, the reversal between LFQ and FSQ under AR/D3PM versus MaskGIT appears way larger than the observed seed variation which seem convincing, I also appreciate the clarification that sampler settings are selected separately on the validation set for each trained model. I think the claim that validation based sampler selection consistently improves both models, rather than one fixed sampler configuration transferring across seeds is great and should be reflected clearly in the revised paper. The medical-specific concern is also clearer now. I appreciate that the authors do not claim that the observations are unique to medical imaging and will limit the empirical claims to the low-resolution medical setting tested here. The ChestMNIST subsampling experiment is useful for ruling out dataset size as the simple explanation for the PneumoniaMNIST reversal, although it does not replace the requested natural-image replication. I view this primarily as a remaining limitation on external validity rather than a problem with the supported claims, so no problems there. \n\nI have two remaining questions:\n\n* The seeded experiments support the existence of a tokenizer-generator interaction within the vocabulary-1024 block, but Table 3’s exact variance-decomposition percentages are still based on the full single-seed grid. Do the authors plan to present these percentages only as descriptive results and avoid implying that their precise magnitudes are statistically established? I think the multi-seed subset now supports the qualitative interaction claim, but not necessarily the exact quantitative decomposition across the complete grid.\n* For the 12-cell FID-2048 comparison, could the authors provide the individual FID-192 and FID-2048 values, or at least confirm whether the central tokenizer-generator reversals are preserved under FID-2048? A Spearman correlation of 0.80 and agreement on the broad regimes are reassuring, but it would be useful to know whether the interaction underlying the main claim is also visible under the standard metric."+ },+ "createdAt": "2026-07-30T23:24:20.358Z",+ "modifiedAt": "2026-11-19T16:42:46.690Z",+ "url": "https://openreview.net/forum?id=xImy5OosQz¬eId=c31qFwDbSs",+ "license": "CC-BY-4.0"+}
reviews/openreview/ximy5oosqz/notes/hagaofa3of.json added
+++ b/reviews/openreview/ximy5oosqz/notes/hagaofa3of.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "HagAOfa3OF",+ "replyTo": "c31qFwDbSs",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the follow-up. We agree with both remaining points and have revised the scope of the claims accordingly.\n\nFor Table 3, the variance decomposition should be treated as descriptive of the observed full grid. The three-seed subset supports the qualitative conclusion that quantizer and generator are not separable, but it does not make the exact 38.7%, 18.8%, and 17.0% shares inferential. Those percentages were calculated from the single-seed full grid, so we will label them as descriptive and will not attach statistical significance to their precise values.\n\nWe also computed FID-192 and FID-2048 on the same 10,000 generated images for the nine vocabulary-1024 interaction cells:\n\n| Generator | Quantizer | FID-192 | FID-2048 |\n| --------- | --------- | ------: | -------: |\n| AR | VQ | 2.15 | 192.4 |\n| AR | LFQ | 0.34 | 52.0 |\n| AR | FSQ | 0.42 | 35.4 |\n| MaskGIT | VQ | 1.41 | 295.5 |\n| MaskGIT | LFQ | 1.91 | 78.3 |\n| MaskGIT | FSQ | 1.15 | 195.1 |\n| D3PM | VQ | 1.55 | 238.5 |\n| D3PM | LFQ | 0.44 | 42.4 |\n| D3PM | FSQ | 1.14 | 59.3 |\n\nThe main conclusion still holds under FID-2048: the quantizer ranking depends on the generator. Under FID-2048, FSQ is best with AR, while LFQ is best with MaskGIT and D3PM. There is therefore no single quantizer ranking that applies across generators.\n\nThe clearest interaction is the D3PM row, where both metrics give the same ordering:\n\nLFQ < FSQ < VQ\n\nThe gaps are also large under both metrics. FID-192 gives 0.44, 1.14, and 1.55, while FID-2048 gives 42.4, 59.3, and 238.5. VQ is also the weakest quantizer under both AR and D3PM for both metrics.\n\nSome of the finer orderings are not stable. Under AR, LFQ is slightly better than FSQ under FID-192, while FSQ is better under FID-2048. This is already one of the comparisons that falls within seed variation: the mean gap is 0.18, compared with a three-standard-deviation threshold of 0.65. We therefore do not claim an ordering between LFQ and FSQ under AR.\n\nThe MaskGIT row is also metric-dependent. FID-192 favours FSQ, while FID-2048 favours LFQ. These cells are all in the relatively poor FID-192 range of 1.15–1.91, and their ordering is sensitive to both training seed and feature representation. We will therefore treat the MaskGIT ordering as unresolved.\n\nThe revised claim will be at the level supported by both analyses. The structural interaction is robust: the preferred quantizer changes with the generator under both FID-192 and FID-2048. The large D3PM differences are stable across metrics, and VQ remains weakest under AR and D3PM. We will not make claims about the exact ordering of the closer AR and MaskGIT cells, where neither the seed analysis nor the metric comparison gives a stable answer."+ },+ "createdAt": "2026-07-31T18:53:07.653Z",+ "modifiedAt": "2026-11-19T16:42:46.520Z",+ "url": "https://openreview.net/forum?id=xImy5OosQz¬eId=HagAOfa3OF",+ "license": "CC-BY-4.0"+}
reviews/openreview/ximy5oosqz/notes/u3bq7cbvwz.json added
+++ b/reviews/openreview/ximy5oosqz/notes/u3bq7cbvwz.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "u3bq7CBvwZ",+ "replyTo": "YqfN40JeIO",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Closing summary for the AC and PCs",+ "comment": "Thank you again to the AC and reviewers for the time spent on the paper and discussion. Since the meta-review was written before the additional experiments, we wanted to leave a brief summary of what changed before the discussion closes. We have responded to each question in the individual threads, including the experiments we could not complete.\n\nWe agree that the observation that reconstruction quality does not predict generation quality is already established in natural-image work. We will cite that work directly and will not present this observation alone as the novelty of the paper. The additional result from the discussion is a generator-free statistic, neighbour-conditional predictive gain, which separates the tokenizer families in the current nine-tokenizer analysis with rank-AUC 1.00, whereas reconstruction PSNR has Spearman correlation +0.01 and marginal token entropy has rank-AUC 0.50. Given the small sample, we will present this as an initial result rather than a general measure of tokenizer modelability.\n\nWe also believe the matched factorial supports a more specific contribution: tokenizer, generator, and sampler choices are not separable. The best quantizer changes with the generator, and validation-based sampler selection can change the apparent generator ranking. We are not aware of prior work that studies this full interaction in one matched design, although the individual observations are clearly related to earlier natural-image results.\n\nThe evidence for this claim is now stronger than in the submitted paper. We retrained the vocabulary-1024 interaction block using three seeds, all evaluated on the same GPU. Six of the nine pairwise quantizer comparisons are larger than three times the pooled standard deviation. We have also identified the three comparisons that remain within seed variation and will no longer claim those orderings. The exact variance-decomposition percentages in Table 3 remain descriptive because they were calculated from the single-seed full grid; the seeded subset supports the qualitative interaction, not the precise percentage shares.\n\nWe also repeated the full validation-based sampler-selection procedure for D3PM and SEDD at all three seeds. The tuned mean FID-192 values are 0.113 and 0.112, compared with defaults of 0.44 and 0.41, corresponding to mean improvements of 3.9x and 3.7x. The selected setting varies between seeds, but the improvement is present in every case. The revised claim will therefore concern validation-based selection for each trained model, not transfer of one fixed sampler setting between seeds.\n\nFor the metric concern, FID-192 and standard FID-2048 have Spearman correlation 0.80 across 12 cells, and a classifier two-sample test agrees with FID-192 at Spearman 0.78. Looking at the individual vocabulary-1024 cells, the structural interaction remains under FID-2048. In particular, the D3PM ordering is identical under both metrics, LFQ < FSQ < VQ, and VQ is weakest under both AR and D3PM. Some closer AR and MaskGIT orderings change between metrics or fall within seed variation, so we will treat those specific orderings as unresolved rather than claiming a winner.\n\nThe standard-FID analysis also showed that Appendix C is wrong to describe FID-2048 as degenerate at 64 x 64. Its real-versus-real floor at 10,000 samples is 2.31, with no negative values across 20 resamples. We will correct this and present FID-192 as a lower-dimensional internal metric whose broad ranking agrees with standard FID, not as a necessary replacement.\n\nFinally, we tested whether the PneumoniaMNIST reversal could be explained simply by training-set size. Subsampling ChestMNIST to 4,700 examples did not cause VQ to overtake LFQ, so sample count alone is not the explanation. This does not establish the cause of the reversal, and we still lack the requested natural-image and higher-resolution replications. We will therefore restrict the claims to the low-resolution medical-style setting tested and retain external validity and clinical utility as limitations.\n\nWe think the revised paper is more narrowly framed and better supported than the submitted version: it establishes the tokenizer–generator interaction within the seeded block, shows that validation-based sampler selection is robust across seeds, reports an initial generator-free statistic related to modelability, and gives a practical recommendation to evaluate the tokenizer jointly with the generator and sampler rather than selecting it from reconstruction alone. We are grateful to the reviewers for the comments that led to these experiments and revisions, and we would welcome reconsideration in light of the discussion."+ },+ "createdAt": "2026-08-04T11:28:19.021Z",+ "modifiedAt": "2026-11-19T16:42:46.687Z",+ "url": "https://openreview.net/forum?id=xImy5OosQz¬eId=u3bq7CBvwZ",+ "license": "CC-BY-4.0"+}
reviews/openreview/ximy5oosqz/notes/yqfn40jeio.json modified
+++ b/reviews/openreview/ximy5oosqz/notes/yqfn40jeio.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair egPa","content": {- "metareview": "This paper presents a controlled empirical study of tokenizer-generator-sampler coupling in low-resolution medical image generation. The reviewers generally found the paper clearly written, technically careful, and valuable as an empirical study, while also raising several important concerns, including limited novelty, limited external validity, reliance on single-seed evaluation, and the use of non-standard FID-192 as the primary metric.\n\nThe main weaknesses are as follows. First, the experimental scope is limited: the primary setting is 64 x 64 ChestMNIST, and the cross-dataset replication is also limited. This setting is appropriate for controlled analysis, but it does not support broad conclusions about high-resolution or clinically realistic medical image generation. Second, the original full experimental grid remains largely single-seed. The authors added multi-seed evidence for the vocabulary-1024 block in the rebuttal, but this is not equivalent to a full multi-seed replication of the entire 54-cell design. Therefore, the exact variance-decomposition values and some fine-grained rankings should be interpreted as descriptive rather than inferential. Third, the use of FID-192 remains a limitation. The FID-2048 comparison added after the rebuttal is reassuring at the level of broad trends, but some closer AR/MaskGIT rankings are sensitive to the evaluation metric. Finally, the medical-image-generation framing should remain narrow: the work does not demonstrate clinical utility, pathology-conditional generation, radiologist evaluation, or downstream augmentation benefit.\n\nNevertheless, the rebuttal substantially strengthens the case for acceptance. The authors directly addressed the most important reviewer concerns with additional experiments rather than only textual clarification. They added three-seed validation for a representative vocabulary-1024 block, showing that the key tokenizer-generator interaction is larger than the observed seed variation in the main comparisons. They also repeated validation-based sampler selection for D3PM and SEDD across seeds, supporting the claim that default sampler settings may substantially underestimate the performance of these models. In addition, they compared FID-192, FID-2048, and a classifier two-sample test, acknowledged and corrected the overstatement that FID-2048 degenerates at this resolution, and appropriately narrowed claims where metric or seed sensitivity remains.\n\nThe core contribution of the paper is that, in a low-resolution medical-style benchmark, it uses a matched factorial design to show that tokenizer, generator, and sampler choices interact, making independent component ranking unreliable. This provides practical guidance for system design: tokenizer selection should be evaluated jointly with the downstream generator and sampler, rather than decided solely from reconstruction metrics. The neighbour-conditional predictive gain analysis added in the rebuttal is also a useful preliminary attempt to characterize tokenizer modelability, although it should be presented as exploratory given the small number of tokenizer configurations.\n\nOverall, I find this submission technically solid, honest about its limitations, and meaningfully strengthened by the rebuttal. Although its scope and generality remain limited, the controlled experimental design and post-rebuttal robustness checks make its empirical contribution sufficiently valuable for the conference. I recommend acceptance, with the expectation that the camera-ready version clearly narrows the claims, labels the variance decomposition as descriptive, reports the FID-2048 comparison, and avoids overclaiming clinical relevance or universal tokenizer rankings."+ "metareview": "This paper presents a controlled empirical study of tokenizer-generator-sampler coupling in low-resolution medical image generation. The reviewers generally found the paper clearly written, technically careful, and valuable as an empirical study, while also raising several important concerns, including limited novelty, limited external validity, reliance on single-seed evaluation, and the use of non-standard FID-192 as the primary metric.\n\nThe main weaknesses are as follows. First, the experimental scope is limited: the primary setting is 64 x 64 ChestMNIST, and the cross-dataset replication is also limited. This setting is appropriate for controlled analysis, but it does not support broad conclusions about high-resolution or clinically realistic medical image generation. Second, the original full experimental grid remains largely single-seed. The authors added multi-seed evidence for the vocabulary-1024 block in the rebuttal, but this is not equivalent to a full multi-seed replication of the entire 54-cell design. Therefore, the exact variance-decomposition values and some fine-grained rankings should be interpreted as descriptive rather than inferential. Third, the use of FID-192 remains a limitation. The FID-2048 comparison added after the rebuttal is reassuring at the level of broad trends, but some closer AR/MaskGIT rankings are sensitive to the evaluation metric. Finally, the medical-image-generation framing should remain narrow: the work does not demonstrate clinical utility, pathology-conditional generation, radiologist evaluation, or downstream augmentation benefit.\n\nNevertheless, the rebuttal substantially strengthens the case for acceptance. The authors directly addressed the most important reviewer concerns with additional experiments rather than only textual clarification. They added three-seed validation for a representative vocabulary-1024 block, showing that the key tokenizer-generator interaction is larger than the observed seed variation in the main comparisons. They also repeated validation-based sampler selection for D3PM and SEDD across seeds, supporting the claim that default sampler settings may substantially underestimate the performance of these models. In addition, they compared FID-192, FID-2048, and a classifier two-sample test, acknowledged and corrected the overstatement that FID-2048 degenerates at this resolution, and appropriately narrowed claims where metric or seed sensitivity remains.\n\nThe core contribution of the paper is that, in a low-resolution medical-style benchmark, it uses a matched factorial design to show that tokenizer, generator, and sampler choices interact, making independent component ranking unreliable. This provides practical guidance for system design: tokenizer selection should be evaluated jointly with the downstream generator and sampler, rather than decided solely from reconstruction metrics. The neighbour-conditional predictive gain analysis added in the rebuttal is also a useful preliminary attempt to characterize tokenizer modelability, although it should be presented as exploratory given the small number of tokenizer configurations.\n\nOverall, I find this submission technically solid, honest about its limitations, and meaningfully strengthened by the rebuttal. Although its scope and generality remain limited, the controlled experimental design and post-rebuttal robustness checks make its empirical contribution sufficiently valuable for the conference. I recommend acceptance, with the expectation that the camera-ready version clearly narrows the claims, labels the variance decomposition as descriptive, reports the FID-2048 comparison, and avoids overclaiming clinical relevance or universal tokenizer rankings.",+ "final_justification": "My final justification for the recommendation is provided in the meta-review above, taking into account the reviews, author response, and reviewer discussion."},"createdAt": "2026-07-24T05:00:31.204Z",- "modifiedAt": "2026-11-18T15:22:02.928Z",+ "modifiedAt": "2026-11-19T05:01:14.490Z","url": "https://openreview.net/forum?id=xImy5OosQz¬eId=YqfN40JeIO","license": "CC-BY-4.0"}