potentialpaper

Selective Answering for Medical VQA via Parallel Independent Claim Verification

Update NeurIPS 2026 submission jPgQvPpJTX: 5 notes

@openreview[bot] · 2026-11-24 15:54 UTC · 723c5050e47a ·

Evidence

reviews/openreview/jpgqvppjtx/notes/1homaatkq7.json added

+++ b/reviews/openreview/jpgqvppjtx/notes/1homaatkq7.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "1HomaatKQ7",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Summary of rebuttal",
+ "comment": "We thank the reviewer again for the constructive feedback. Based on the reviews and the Meta Reviewer’s guidance, we conducted additional analyses addressing the shared concerns regarding final-answer correctness, benchmark–method alignment, statistical precision, architectural attribution, and inference cost.\n\nIn particular, we now show that:\n\n- PICV maintains nearly unchanged conditional answer accuracy relative to Direct answering (0.593 vs. 0.598), while substantially reducing harmful answers from 69.4 to 41.4 per 100 queries.\n- Its safety–coverage advantage remains under a taxonomy-disjoint visual-degradation condition, after removing choice_missing, and on open-ended questions.\n- Holding claim-level evidence fixed, deterministic aggregation outperforms a prompted same-backbone judge at matched coverage and harm budgets.\n- The SLAKE image-mismatch analysis identifies benchmark noise, while excluding the affected cases further strengthens the safety–coverage result.\n- We explicitly report the computational and engineering trade-offs, including 4.65 calls per sample and the limited coverage of the manually constructed entity–region map.\n\nWe have consequently narrowed the paper’s central claim: PICV does not improve unconditional VQA accuracy or establish general clinical robustness; rather, within the evaluated English radiology VQA setting, it improves the safety–coverage frontier by preserving independently verified negative evidence.\n\nWe would be grateful if the reviewer could let us know whether these additional results and the revised claim address the main concerns raised in the review, or whether any critical issue remains unresolved."
+ },
+ "createdAt": "2026-08-03T02:50:18.019Z",
+ "modifiedAt": "2026-11-19T16:51:40.958Z",
+ "url": "https://openreview.net/forum?id=jPgQvPpJTX&noteId=1HomaatKQ7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jpgqvppjtx/notes/6zgjbhxhgz.json modified

+++ b/reviews/openreview/jpgqvppjtx/notes/6zgjbhxhgz.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair bBz1",
"content": {
- "metareview": "This paper addresses an important problem in medical visual question answering: selective answering, where models should abstain when the available image evidence is insufficient to support a reliable answer. It proposes Parallel Independent Claim Verification (PICV), which decomposes questions into independent visual claims, verifies each claim separately, and combines a deterministic rule-based decision process. The paper also introduces an automatically constructed answerability benchmark based on reproducible corruption procedures over two public radiology VQA datasets. The evaluation across multiple VLM backbones demonstrates consistent improvements in answerability prediction. However, several important questions remain:\n\n1. Evaluation beyond answerability prediction. Reviewers noted that the current evaluation primarily measures answerability decisions rather than the correctness of the generated medical answers themselves. Since PICV ultimately produces answers whenever it decides an input is answerable, please clarify whether the proposed framework also maintains or improves answer correctness on answerable cases, and discuss how selective answering interacts with downstream VQA accuracy.\n2. Generalizability of the proposed benchmark and evaluation protocol. Reviewers raised concerns that the benchmark is constructed using corruption types that closely align with PICV’s verifier taxonomy, potentially favoring the proposed method. Please clarify the intended scope of the benchmark, discuss this potential source of evaluation bias, and explain how the proposed framework is expected to generalize to naturally occurring unanswerable clinical scenarios beyond the current synthetic corruption setting.\n3. Scope of empirical validation. The current evaluation is conducted on relatively small subsets of two radiology VQA benchmarks. Please clarify the robustness of the reported improvements, discuss the limitations imposed by the current benchmark size and domain coverage, and explain how the proposed approach is expected to scale to broader medical VQA settings.\n4. Evidence supporting the claimed architectural advantage. Reviewers requested additional clarification regarding whether the reported improvements arise specifically from deterministic aggregation, rather than from the claim decomposition itself or other design choices. Please clarify the contribution of the individual components of PICV and discuss the extent to which deterministic aggregation is responsible for the observed performance gains.\n5. Presentation of practical trade-offs. Since the paper emphasizes both improved safety and inference efficiency, reviewers suggested presenting these trade-offs more explicitly. Please clarify the computational cost relative to competing agentic approaches and discuss the practical implications of the proposed framework for deployment.\n\nWhether these issues can be satisfactorily addressed will significantly influence my final assessment."
+ "metareview": "This paper addresses an important problem in medical visual question answering: selective answering, where models should abstain when the available image evidence is insufficient to support a reliable answer. It proposes Parallel Independent Claim Verification (PICV), which decomposes questions into independent visual claims, verifies each claim separately, and combines a deterministic rule-based decision process. The paper also introduces an automatically constructed answerability benchmark based on reproducible corruption procedures over two public radiology VQA datasets. The evaluation across multiple VLM backbones demonstrates consistent improvements in answerability prediction. However, several important questions remain:\n\n1. Evaluation beyond answerability prediction. Reviewers noted that the current evaluation primarily measures answerability decisions rather than the correctness of the generated medical answers themselves. Since PICV ultimately produces answers whenever it decides an input is answerable, please clarify whether the proposed framework also maintains or improves answer correctness on answerable cases, and discuss how selective answering interacts with downstream VQA accuracy.\n2. Generalizability of the proposed benchmark and evaluation protocol. Reviewers raised concerns that the benchmark is constructed using corruption types that closely align with PICV’s verifier taxonomy, potentially favoring the proposed method. Please clarify the intended scope of the benchmark, discuss this potential source of evaluation bias, and explain how the proposed framework is expected to generalize to naturally occurring unanswerable clinical scenarios beyond the current synthetic corruption setting.\n3. Scope of empirical validation. The current evaluation is conducted on relatively small subsets of two radiology VQA benchmarks. Please clarify the robustness of the reported improvements, discuss the limitations imposed by the current benchmark size and domain coverage, and explain how the proposed approach is expected to scale to broader medical VQA settings.\n4. Evidence supporting the claimed architectural advantage. Reviewers requested additional clarification regarding whether the reported improvements arise specifically from deterministic aggregation, rather than from the claim decomposition itself or other design choices. Please clarify the contribution of the individual components of PICV and discuss the extent to which deterministic aggregation is responsible for the observed performance gains.\n5. Presentation of practical trade-offs. Since the paper emphasizes both improved safety and inference efficiency, reviewers suggested presenting these trade-offs more explicitly. Please clarify the computational cost relative to competing agentic approaches and discuss the practical implications of the proposed framework for deployment.\n\nWhether these issues can be satisfactorily addressed will significantly influence my final assessment.",
+ "final_justification": "I have read the authors’ response in full, including the additional analyses and the post-rebuttal reviewer discussion. My initial meta-review leaned toward rejection because the original submission did not adequately establish final-answer correctness, benchmark neutrality, the specific benefit of deterministic aggregation, statistical robustness, or the practical cost of the method. The rebuttal provides substantial new evidence on each of these points and appropriately narrows the paper’s claims. On balance, this changes my recommendation to acceptance.\n\nThe engaged reviewers reached a similar conclusion. Two reviewers raised their ratings from Borderline Reject to Borderline Accept after examining the new analyses. One explicitly concluded that all major concerns had been addressed, while the other found that the evidence regarding retained-answer accuracy, benchmark-method alignment, and deterministic aggregation materially improved the paper. The remaining reviewer did not provide the requested final rating or justification after rebuttal and did not document a reassessment under the corrected Use-inspired contribution type. Following the Program Chairs’ guidance, I therefore place less weight on that unchanged score, while still considering the substantive concerns raised in the review.\n\nOverall, the paper identifies a concrete and safety-relevant failure mode in single-judge medical VQA verification, proposes a transparent inference-time alternative, and provides evidence across four VLM backbones that independently verified claims and deterministic aggregation improve the safety-coverage frontier. The additional rebuttal analyses resolve the main concerns underlying my initial recommendation, while the remaining limitations principally constrain the scope of the claims rather than invalidate the contribution. I therefore recommend acceptance as a poster. \n\nFinally, the reference “3d-RAD: A comprehensive 3d radiology med-VQA dataset with multi-temporal analysis and diverse diagnostic tasks” was flagged because the publication year is incorrect. The authors must correct this reference in the final version."
},
"createdAt": "2026-07-21T11:07:20.548Z",
- "modifiedAt": "2026-11-18T15:22:10.137Z",
+ "modifiedAt": "2026-11-19T05:01:18.435Z",
"url": "https://openreview.net/forum?id=jPgQvPpJTX&noteId=6zGjbHxhgz",
"license": "CC-BY-4.0"
}

reviews/openreview/jpgqvppjtx/notes/7epczmcfsi.json added

+++ b/reviews/openreview/jpgqvppjtx/notes/7epczmcfsi.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "7EpCzmcfsI",
+ "replyTo": "USwtT2YAXP",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal to Reviewer KNee",
+ "comment": "We thank the reviewer for emphasizing that answerability prediction alone is insufficient to establish the usefulness of selective medical VQA. \nWe added analyses of retained-answer correctness, safety–coverage trade-offs, benchmark validity, entity-map coverage, and learned aggregation baselines.\n\n\n---\n\n## W1 & Q1. Final-Answer Correctness\n\n> “The primary metric AnsF1 is defined over the answer/abstain decision. It does not directly evaluate whether the generated answer is medically correct when the model chooses to answer.”\n\n> “Can the authors evaluate final answer correctness on answerable cases, not only answerability F1?”\n\nWe now evaluate answers on the same 366 answerable cases for which PICV selects `ANSWER`. Conditional SoftAcc is **0.593 for PICV and 0.598 for Direct**, showing that the accuracy of retained answers is nearly unchanged.\n\nWhen abstentions are counted as errors over all answerable cases, accuracy decreases from **0.613 to 0.543**. We therefore distinguish retained-answer accuracy, coverage, and overall answerable-case accuracy rather than implying that abstention is cost-free.\n\nPICV reduces harmful answers—wrong answers on answerable cases or unsupported answers on unanswerable cases—from **69.4 to 41.4 per 100 queries**. At the same harmful-answer budget, it answers more questions than all seven baselines; at the same coverage, it produces fewer harmful answers than Direct, Two-stage, and ReAct-Med.\n\nOur revised claim is that PICV improves the **safety–coverage trade-off**, not that it improves unconditional VQA accuracy. We will describe SoftAcc as benchmark answer equivalence rather than clinician-verified medical correctness.\n\n---\n\n## W2. Limited Sample Size\n\n> “The per-cell sample size may be too limited for broad claims about robust medical VQA behavior.”\n\nWe agree. The current per-cell results support consistent improvement over Direct, but do not establish universal superiority over every baseline.\n\nWe will narrow the paper’s claims to the controlled benchmark setting, report exact denominators, and expand the per-cell evaluation in the final version. Because the same source questions are evaluated across multiple backbones, we will also report source-question-clustered uncertainty estimates rather than treating all outputs as independent.\n\n\n---\n\n## W3. Restricted Datasets and Modalities\n\n> “The evaluation is restricted to two public English radiology datasets, SLAKE and VQA-RAD.”\n\nWe agree that the current results do not establish general medical VQA robustness. We will explicitly scope the title, abstract, and conclusion to **selective answering on two English radiology VQA datasets**.\n\nPathology, fundus imaging, non-radiology modalities, non-English questions, and clinical deployment will be identified as untested settings. We will also add a broader-domain evaluation in the final version.\n\n\n---\n\n## Q2. Naturally Occurring Unanswerability\n\n> “How well does PICV perform on naturally occurring unanswerable or ambiguous clinical questions, rather than synthetically corrupted inputs?”\n\nWe added a taxonomy-disjoint `visual_degradation` condition that weakens visual evidence without changing the image identity, question, or choices. No PICV verifier is explicitly designed for this corruption.\n\n| Method | AnsF1 | Coverage at equal harm | AURC |\n| -------- | --------: | ---------------------: | --------: |\n| Direct | 0.667 | 0.787 | 0.800 |\n| ReAct | 0.693 | 0.762 | 0.717 |\n| **PICV** | **0.710** | **0.838** | **0.677** |\n\nPICV has the best observed result among the three evaluated methods. However, this remains a synthetic evidence-degradation setting, not naturally occurring clinical ambiguity.\n\nWe will add naturally occurring ambiguous or insufficient-evidence cases in the final version and report them separately from corruption-based evaluation.\n\n\n---\n\n## Q3. Entity–Region Map Robustness\n\n> “How robust is the 60-entry entity-region table when moving beyond SLAKE and VQA-RAD?”\n\nThe implementation contains **62 manually engineered entries**. Across the current traces, the region verifier maps 49% of the claims for which it is invoked; unmatched entities return `UNCLEAR`.\n\nThis fail-open behavior avoids map-only false `REFUTED` decisions, but reduces the ability to detect mismatches involving unseen or fine-grained entities. We will therefore describe the map as **task-specific knowledge engineering**, not domain-general adaptation, and make no robustness claim for pathology-specific or fine-grained anatomy without additional evaluation.\n\n\n---\n\n## Q4. Fine-Tuned Selective-Prediction Baseline\n\n> “Can the authors compare against a fine-tuned abstention classifier or selective prediction baseline?”\n\nWe trained a supervised aggregation head using the same claim-level verdicts as the deterministic rule.\n\n| Aggregator | Answer rate | AnsF1 | Harmful/100 |\n| ------------------------------ | ----------: | ----: | ----------: |\n| Trained, leave-one-cell-out | 0.635 | 0.819 | 36.9 |\n| Trained, leave-one-dataset-out | 0.535 | 0.742 | 32.0 |\n| Deterministic rule | 0.685 | 0.772 | 41.4 |\n\nThe trained head performs better within the same datasets. Under cross-dataset evaluation, it operates at substantially lower coverage, so the native results do not establish that either approach is superior.\n\nWe will compare the trained head and deterministic rule at matched coverage and matched harmful-answer budgets in the final version. We will also add a leakage-controlled end-to-end selective-prediction baseline.\n\nSeparately, replacing the deterministic rule with the same backbone that generated the verification evidence reduces performance at matched operating points. At equal coverage, the rule achieves higher AnsF1 and **2.25 fewer harmful answers per 100**.\n\nThis supports the narrower claim that deterministic aggregation preserves isolated negative evidence more reliably than a prompted same-backbone judge.\n\n---\n\n## Q5. Weak SLAKE `image_mismatch` Performance\n\n> “Can the authors provide more analysis of the weak image_mismatch TAR on SLAKE?”\n\nWe found that **25 of 166 SLAKE `image_mismatch` cases** retain a donor-image annotation that answers the same normalized question. These cases therefore do not reliably remove the required evidence and provide an automatic lower bound on benchmark noise.\n\nAfter excluding them, PICV’s safety–coverage advantage remains and its harmful-answer rate decreases from **41.4 to 33.7 per 100**.\n\nWe have prepared a blinded 50-case clinician-audit set. The completed adjudication will be reported in the final version in either direction. Until then, we treat the automatic analysis as evidence consistent with label noise, not a clinician-verified noise estimate.\n\n---\n\n## Revision Summary\n\nThe final version will jointly report answerability, retained-answer correctness, overall answerable-case accuracy, coverage, harmful answers, false refusals, and inference cost. We will also explicitly acknowledge the limited sample size, two-dataset radiology scope, synthetic ambiguity, incomplete entity-map coverage, and absence of clinician-adjudicated correctness."
+ },
+ "createdAt": "2026-07-28T15:40:38.035Z",
+ "modifiedAt": "2026-11-19T16:51:40.955Z",
+ "url": "https://openreview.net/forum?id=jPgQvPpJTX&noteId=7EpCzmcfsI",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jpgqvppjtx/notes/bd9k0f1ske.json added

+++ b/reviews/openreview/jpgqvppjtx/notes/bd9k0f1ske.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Bd9k0f1sKe",
+ "replyTo": "ioGsH4smCl",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal to Reviewer of7B",
+ "comment": "We thank the reviewer for identifying three central concerns: benchmark–method alignment, missing answer-accuracy evaluation, and limited statistical precision. We added direct controls for each and revise the primary evaluation from raw AnsF1 to **coverage at equal harm** and **harmful answers at equal coverage**.\n\n---\n\n## W1. Benchmark–Method Alignment\n\n> “Each corruption type has a matching PICV verifier designed to detect it, while the baselines have no such specialized detectors.”\n\nWe agree that the original benchmark is structurally aligned with PICV’s typed verifiers. We therefore added a taxonomy-disjoint `visual_degradation` condition that weakens visual evidence without changing the image identity, question, or answer choices. No PICV verifier or rule is explicitly specialized to this condition.\n\n| Method | AnsF1 | Coverage at equal harm | AURC |\n| -------- | --------: | ---------------------: | --------: |\n| Direct | 0.667 | 0.787 | 0.800 |\n| ReAct | 0.693 | 0.762 | 0.717 |\n| **PICV** | **0.710** | **0.838** | **0.677** |\n\nPICV has the best observed result among the three evaluated methods, providing initial evidence beyond its original taxonomy. We will report this as limited synthetic evidence rather than proof of robustness to naturally occurring ambiguity.\n\nWe also removed all `choice_missing` cases. Raw AnsF1 gains become substantially smaller, confirming that multiple-choice verification contributes to the original margin. However, at an equal harmful-answer budget, PICV still answers more questions than 6 of 7 baselines, and the same pattern holds on open-ended questions.\n\nOur revised claim is therefore:\n\n> Benchmark alignment contributes to the raw AnsF1 gain, but PICV’s safety–coverage advantage is not limited to corruption types explicitly matched by its verifiers.\n\nThe final version will additionally include naturally occurring ambiguous or insufficient-evidence cases.\n\n---\n\n## W2 & Q2. Final-Answer Accuracy\n\n> “The paper never reports whether the answers produced by A4, when (d=\\text{ANSWER}), are actually correct.”\n\nWe now evaluate A4’s answers on the same 366 answerable cases retained by PICV. Conditional SoftAcc is **0.593 for PICV and 0.598 for Direct**, indicating that the accuracy of retained answers is nearly unchanged.\n\nWhen abstentions are counted as incorrect over all answerable cases, accuracy decreases from **0.613 to 0.543**. We will therefore report conditional accuracy, overall answerable-case accuracy, and coverage together rather than implying that abstention is cost-free.\n\nPICV reduces harmful answers—wrong answers on answerable cases or unsupported answers on unanswerable cases—from **69.4 to 41.4 per 100 queries**. At equal coverage, it produces fewer harmful answers than Direct, Two-stage, and ReAct-Med.\n\nOur supported conclusion is that PICV improves the **safety–coverage trade-off**, not unconditional VQA accuracy. We will describe SoftAcc as benchmark answer equivalence rather than clinician-verified medical correctness.\n\n---\n\n## W3. Benchmark Size and Statistical Precision\n\n> “Each dataset has only 100 instances… No bootstrap confidence intervals are reported at the per-cell level.”\n\nWe agree that the original statistical framing was too broad. Per-cell analysis supports a more consistent improvement over Direct than over the strongest alternative baseline, so we will treat cross-baseline rankings as descriptive and remove universal robustness claims.\n\nBecause the same source questions are evaluated across multiple backbones, the final version will use **source-question-clustered uncertainty estimates**, report exact corruption-specific denominators, and expand the per-cell evaluation. The `visual_degradation` analysis will similarly be clustered by source pair.\n\n\n---\n\n## Q1. Deterministic Rule versus an LLM Aggregator\n\n> “Can you replace A3 with a lightweight LLM judge that receives the same verdicts?”\n\nWe replaced only the final aggregation rule with the same backbone that generated each verification trace, while keeping A0–A2 and all claim-level evidence fixed.\n\n| Aggregator | Answer rate | AnsF1 | Harmful/100 |\n| --------------------------- | ----------: | --------: | ----------: |\n| **Deterministic rule** | 0.730 | **0.752** | **47.50** |\n| Same-backbone judge, native | 0.580 | 0.602 | 37.00 |\n| Judge at rule coverage | 0.730 | 0.659 | 49.75 |\n| Judge at rule harm budget | 0.708 | 0.650 | 47.50 |\n\nAt equal coverage, the deterministic rule achieves higher AnsF1 and **2.25 fewer harmful answers per 100**. At the same harmful-answer budget, it provides additional coverage.\n\nThis supports the narrower claim that deterministic aggregation preserves isolated negative evidence more reliably than the evaluated prompted same-backbone judge. We do not claim superiority over every possible learned aggregator.\n\n\n---\n\n## Q3. SLAKE without `image_mismatch`\n\n> “Would the authors report PICV results with `image_mismatch` instances excluded from SLAKE?”\n\nYes. Removing all SLAKE `image_mismatch` cases leaves 86 samples per backbone. PICV ranks first in prior-balanced AnsF1 across all four SLAKE backbone settings, with scores from **0.729 to 0.870** and margins of **0.062–0.136** over the strongest baseline.\n\nThis shows that PICV’s SLAKE performance is not dependent on the weak `image_mismatch` axis.\n\nWe also found that 25 of 166 SLAKE `image_mismatch` cases retain a donor-image annotation answering the same normalized question, indicating that some swaps do not remove the required evidence. A blinded clinician audit will be reported in the final version. Until it is completed, we treat the automatic analysis only as evidence consistent with label noise.\n\n\n---\n\n## Revised Contribution\n\nWe will narrow the contribution to:\n\n1. identifying and quantifying supported bias in single-judge selective VQA;\n2. showing that isolated claim verification improves the safety–coverage trade-off; and\n3. demonstrating that deterministic aggregation preserves claim-level negative evidence better than a prompted same-backbone aggregator under matched operating points.\n\nWe will explicitly scope these findings to two English radiology VQA datasets and avoid claims of comprehensive clinical robustness."
+ },
+ "createdAt": "2026-07-28T15:54:45.998Z",
+ "modifiedAt": "2026-11-19T16:51:40.879Z",
+ "url": "https://openreview.net/forum?id=jPgQvPpJTX&noteId=Bd9k0f1sKe",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/jpgqvppjtx/notes/i95zg23yct.json added

+++ b/reviews/openreview/jpgqvppjtx/notes/i95zg23yct.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "I95Zg23YcT",
+ "replyTo": "YxJLQSZ9e6",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Rebuttal to Reviewer Ci6h",
+ "comment": "We thank the reviewer for identifying concrete analyses that could change the assessment. We completed the requested cost analysis, taxonomy-disjoint evaluation, `choice_missing`-excluded analysis, and label-quality investigation. We also revise the primary evaluation from raw AnsF1 to **coverage at matched harm and harm at matched coverage**.\n\n---\n\n## W1. Limited Conceptual Novelty\n\n> “The work reads as a careful engineering instantiation for one domain; the only fresh element is the supported-bias diagnosis.”\n\nWe agree that decomposition, verification, and deterministic rules are not individually new primitives. We will narrow the contribution to:\n\n1. the empirical diagnosis of **supported bias**, where a single judge systematically fails to preserve negative evidence;\n2. isolated claim verification for conflicting medical evidence; and\n3. evidence that deterministic aggregation preserves this evidence more reliably than a prompted same-backbone judge under matched operating points.\n\nWe will not claim that PICV introduces each component independently or outperforms every learned selective predictor.\n\n---\n\n## W2 & Q1. Cost–Quality Trade-off\n\n> “Please add an avg-calls column or AnsF1-vs-calls scatter to Table 1.”\n\nPICV uses an average of **4.65 calls per sample**, compared with 8.86 for MediQ-Scale.\n\n| Method | Mean calls/sample |\n| ----------- | ----------------: |\n| CoT-Abstain | 1.00 |\n| Two-stage | 1.33 |\n| Self-Ask | 1.75 |\n| ReAct-Med | 2.00 |\n| **PICV** | **4.65** |\n| MediQ-Scale | 8.86 |\n\nPICV is therefore more call-efficient than the iterative MediQ-Scale baseline, but more expensive than single- or short-pass methods. We will add calls per sample to the main table and include a cost–quality scatter. We will describe this as **call efficiency**, not a general monetary or latency advantage.\n\n---\n\n## W3 & Q2. Benchmark Neutrality\n\n> “The corruption axes map almost 1:1 onto PICV’s typed reasons.”\n\n> “Please show PICV still wins on a corruption not aligned to its taxonomy.”\n\nWe added a taxonomy-disjoint `visual_degradation` condition that weakens visual evidence without changing the image identity, question, or choices. No PICV verifier or aggregation rule is explicitly specialized to this condition.\n\n| Method | AnsF1 | Coverage at equal harm | AURC |\n| -------- | --------: | ---------------------: | --------: |\n| Direct | 0.667 | 0.787 | 0.800 |\n| ReAct | 0.693 | 0.762 | 0.717 |\n| **PICV** | **0.710** | **0.838** | **0.677** |\n\nPICV achieves the best observed result among the three evaluated methods. This provides taxonomy-independent evidence, although the current sample remains limited. We will report source-pair-clustered uncertainty and add naturally occurring insufficient-evidence cases in the final version.\n\n---\n\n## W4 & Q3. SLAKE Label Validity\n\n> “A ~50-case clinician audit would show how much the low TAR is label noise versus model failure.”\n\nWe found that **25 of 166 SLAKE `image_mismatch` cases** retain a donor-image annotation answering the same normalized question. These cases do not reliably remove the required evidence and constitute an automatic lower bound on invalid unanswerable labels.\n\nAfter excluding them, PICV’s safety–coverage advantage remains, and its harmful-answer rate decreases from **41.4 to 33.7 per 100 queries**.\n\nA blinded 50-case clinician-audit set is prepared. The completed adjudication will be reported in the final version in either direction. Until then, we describe the automatic result as evidence consistent with label noise, not a clinician-verified estimate.\n\n---\n\n## W5. Statistical Strength\n\n> “Each cell has only 100 samples, and the sign/Wilcoxon tests treat correlated cells as independent.”\n\nWe agree that the original statistical framing was too strong. The per-cell evidence is more consistent against Direct than against the strongest baseline, and we will present the latter as descriptive rather than confirmatory.\n\nBecause the same questions are evaluated across multiple backbones, the final version will use **source-question-clustered uncertainty estimates**, report exact corruption-specific denominators, and avoid broad claims of universal medical VQA robustness.\n\n---\n\n## W6 & Q4. Gains Outside `choice_missing`\n\n> “Please report results excluding `choice_missing` to separate general selective answering from per-option MCQ verification.”\n\nThe reviewer’s concern is supported by raw AnsF1: after removing `choice_missing`, PICV is the top method in only 1 of 8 cells.\n\nHowever, raw AnsF1 compares systems operating at substantially different answer rates. At the same harmful-answer budget, PICV answers more questions than 6 of 7 baselines after removing `choice_missing`:\n\n| Comparator | Coverage gain at equal harm |\n| ------------ | --------------------------: |\n| Self-Ask | **+0.325** |\n| CoT-Abstain | **+0.245** |\n| MediQ-Scale | **+0.211** |\n| MediQ-Binary | **+0.192** |\n| Two-stage | **+0.122** |\n| ReAct-Med | **+0.039** |\n| Direct | +0.033 |\n\nThe same qualitative pattern holds on open-ended questions.\n\nWe therefore revise the claim to:\n\n> `choice_missing` drives much of the raw AnsF1 margin, but PICV’s safety–coverage advantage remains outside multiple-choice verification.\n\n---\n\n## W7. Trivial-Policy Floors\n\n> “A trivial Always-Answer policy already scores 0.667, so absolute AnsF1 may overstate the gain.”\n\nWe agree. We will report Always-Answer and Always-Abstain references beside the corresponding metrics and no longer use raw AnsF1 as the sole headline result.\n\nOur primary comparisons instead fix the operating point:\n\n* At the same harmful-answer budget, PICV answers more questions than all seven baselines on the full benchmark.\n* At the same coverage, PICV produces fewer harmful answers than Direct, Two-stage, and ReAct-Med.\n\nNeither comparison can be improved merely by answering less.\n\n---\n\n## W8. Manual Entity–Region Mapping\n\n> “‘No fine-tuning’ understates the dataset-specific knowledge engineering.”\n\nWe agree. PICV uses a manually defined **62-entry entity–region map**. It covers 175 of 357 invoked region claims; unmatched claims return `UNCLEAR`.\n\nThis fail-open behavior avoids map-only false `REFUTED` decisions but reduces detection power for unseen entities. We will replace “no fine-tuning” with:\n\n> “No gradient-based model update, with a task-specific entity–region map.”\n\nWe will also report mapping coverage and make no out-of-domain robustness claim.\n\n---\n\n## Additional Evaluation\n\nPICV reduces harmful answers from **69.4 to 41.4 per 100 queries**, while the conditional accuracy of the answers it retains remains close to Direct answering (0.593 vs. 0.598). Overall answerable-case accuracy is lower when abstentions are counted as errors, so we will report accuracy, coverage, harmful answers, and false refusals jointly.\n\nHolding claim-level evidence fixed, the deterministic rule also outperforms a prompted same-backbone aggregator at matched operating points. At equal coverage, it achieves higher AnsF1 and **2.25 fewer harmful answers per 100**. We interpret this only as evidence that deterministic aggregation better preserves isolated negative evidence than the evaluated prompted judge.\n\nThe final version will add matched comparisons with the supervised aggregation head and a leakage-controlled selective-prediction baseline."
+ },
+ "createdAt": "2026-07-28T15:46:39.089Z",
+ "modifiedAt": "2026-11-19T16:51:40.958Z",
+ "url": "https://openreview.net/forum?id=jPgQvPpJTX&noteId=I95Zg23YcT",
+ "license": "CC-BY-4.0"
+}