Selective Answering for Medical VQA via Parallel Independent Claim Verification
Import NeurIPS 2026 submission jPgQvPpJTX: 5 notes
@openreview[bot] · 2026-11-22 17:58 UTC · f51debc24f48
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,23 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "jPgQvPpJTX"+ }+ ],+ "title": "Selective Answering for Medical VQA via Parallel Independent Claim Verification",+ "authors": [+ "Donghee Han",+ "Jiwon Jeong",+ "Mun Yong Yi"+ ],+ "abstract": "Medical visual question answering is a safety-critical decision problem in which abstaining on inputs the image cannot support matters as much as answer accuracy. Existing inference-time agentic methods address hallucination by adding a verification step, but they collapse the final decision at a single language-model judge that integrates all evidence in one prompt and is systematically biased toward declaring inputs answerable. We propose PICV (Parallel Independent Claim Verification), which reformulates selective medical VQA as independent claim verification with transparent aggregation: the question is decomposed into a small set of typed visual claims, each is verified by an isolated prompt with no access to the other verdicts, and the verdicts are combined by a deterministic rule rather than another model, yielding an answer/abstain decision together with a typed unanswerability reason. We evaluate PICV efficiently on an automated answerability benchmark we construct over two public radiology datasets via three reproducible corruption procedures, requiring neither heavy VLM judging nor human annotation at evaluation time. Across four VLM backbones, PICV consistently outperforms strong prompting and agentic baselines; ablations attribute the gains specifically to per-claim isolation and rule-based aggregation rather than to agentic decomposition alone.",+ "year": 2026,+ "venue": "NeurIPS 2026",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/jpgqvppjtx/forms.json added
+++ b/reviews/openreview/jpgqvppjtx/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/jpgqvppjtx/notes/6zgjbhxhgz.json added
+++ b/reviews/openreview/jpgqvppjtx/notes/6zgjbhxhgz.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "6zGjbHxhgz",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair bBz1",+ "content": {+ "metareview": "This paper addresses an important problem in medical visual question answering: selective answering, where models should abstain when the available image evidence is insufficient to support a reliable answer. It proposes Parallel Independent Claim Verification (PICV), which decomposes questions into independent visual claims, verifies each claim separately, and combines a deterministic rule-based decision process. The paper also introduces an automatically constructed answerability benchmark based on reproducible corruption procedures over two public radiology VQA datasets. The evaluation across multiple VLM backbones demonstrates consistent improvements in answerability prediction. However, several important questions remain:\n\n1. Evaluation beyond answerability prediction. Reviewers noted that the current evaluation primarily measures answerability decisions rather than the correctness of the generated medical answers themselves. Since PICV ultimately produces answers whenever it decides an input is answerable, please clarify whether the proposed framework also maintains or improves answer correctness on answerable cases, and discuss how selective answering interacts with downstream VQA accuracy.\n2. Generalizability of the proposed benchmark and evaluation protocol. Reviewers raised concerns that the benchmark is constructed using corruption types that closely align with PICV’s verifier taxonomy, potentially favoring the proposed method. Please clarify the intended scope of the benchmark, discuss this potential source of evaluation bias, and explain how the proposed framework is expected to generalize to naturally occurring unanswerable clinical scenarios beyond the current synthetic corruption setting.\n3. Scope of empirical validation. The current evaluation is conducted on relatively small subsets of two radiology VQA benchmarks. Please clarify the robustness of the reported improvements, discuss the limitations imposed by the current benchmark size and domain coverage, and explain how the proposed approach is expected to scale to broader medical VQA settings.\n4. Evidence supporting the claimed architectural advantage. Reviewers requested additional clarification regarding whether the reported improvements arise specifically from deterministic aggregation, rather than from the claim decomposition itself or other design choices. Please clarify the contribution of the individual components of PICV and discuss the extent to which deterministic aggregation is responsible for the observed performance gains.\n5. Presentation of practical trade-offs. Since the paper emphasizes both improved safety and inference efficiency, reviewers suggested presenting these trade-offs more explicitly. Please clarify the computational cost relative to competing agentic approaches and discuss the practical implications of the proposed framework for deployment.\n\nWhether these issues can be satisfactorily addressed will significantly influence my final assessment."+ },+ "createdAt": "2026-07-21T11:07:20.548Z",+ "modifiedAt": "2026-11-18T15:22:10.137Z",+ "url": "https://openreview.net/forum?id=jPgQvPpJTX¬eId=6zGjbHxhgz",+ "license": "CC-BY-4.0"+}
reviews/openreview/jpgqvppjtx/notes/ffwwgpj5kx.json added
+++ b/reviews/openreview/jpgqvppjtx/notes/ffwwgpj5kx.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "FFWwgPJ5kx",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "This paper addresses an important problem in medical visual question answering: selective answering, where models should abstain when the available image evidence is insufficient to support a reliable answer. It proposes Parallel Independent Claim Verification (PICV), which decomposes questions into independent visual claims, verifies each claim separately, and combines a deterministic rule-based decision process. The paper also introduces an automatically constructed answerability benchmark based on reproducible corruption procedures over two public radiology VQA datasets. The evaluation across multiple VLM backbones demonstrates consistent improvements in answerability prediction. However, several important questions remain:\n\n1. Evaluation beyond answerability prediction. Reviewers noted that the current evaluation primarily measures answerability decisions rather than the correctness of the generated medical answers themselves. Since PICV ultimately produces answers whenever it decides an input is answerable, please clarify whether the proposed framework also maintains or improves answer correctness on answerable cases, and discuss how selective answering interacts with downstream VQA accuracy.\n2. Generalizability of the proposed benchmark and evaluation protocol. Reviewers raised concerns that the benchmark is constructed using corruption types that closely align with PICV’s verifier taxonomy, potentially favoring the proposed method. Please clarify the intended scope of the benchmark, discuss this potential source of evaluation bias, and explain how the proposed framework is expected to generalize to naturally occurring unanswerable clinical scenarios beyond the current synthetic corruption setting.\n3. Scope of empirical validation. The current evaluation is conducted on relatively small subsets of two radiology VQA benchmarks. Please clarify the robustness of the reported improvements, discuss the limitations imposed by the current benchmark size and domain coverage, and explain how the proposed approach is expected to scale to broader medical VQA settings.\n4. Evidence supporting the claimed architectural advantage. Reviewers requested additional clarification regarding whether the reported improvements arise specifically from deterministic aggregation, rather than from the claim decomposition itself or other design choices. Please clarify the contribution of the individual components of PICV and discuss the extent to which deterministic aggregation is responsible for the observed performance gains.\n5. Presentation of practical trade-offs. Since the paper emphasizes both improved safety and inference efficiency, reviewers suggested presenting these trade-offs more explicitly. Please clarify the computational cost relative to competing agentic approaches and discuss the practical implications of the proposed framework for deployment.\n\nWhether these issues can be satisfactorily addressed will significantly influence my final assessment.",+ "final_justification": "I have read the authors’ response in full, including the additional analyses and the post-rebuttal reviewer discussion. My initial meta-review leaned toward rejection because the original submission did not adequately establish final-answer correctness, benchmark neutrality, the specific benefit of deterministic aggregation, statistical robustness, or the practical cost of the method. The rebuttal provides substantial new evidence on each of these points and appropriately narrows the paper’s claims. On balance, this changes my recommendation to acceptance.\n\nThe engaged reviewers reached a similar conclusion. Two reviewers raised their ratings from Borderline Reject to Borderline Accept after examining the new analyses. One explicitly concluded that all major concerns had been addressed, while the other found that the evidence regarding retained-answer accuracy, benchmark-method alignment, and deterministic aggregation materially improved the paper. The remaining reviewer did not provide the requested final rating or justification after rebuttal and did not document a reassessment under the corrected Use-inspired contribution type. Following the Program Chairs’ guidance, I therefore place less weight on that unchanged score, while still considering the substantive concerns raised in the review.\n\nOverall, the paper identifies a concrete and safety-relevant failure mode in single-judge medical VQA verification, proposes a transparent inference-time alternative, and provides evidence across four VLM backbones that independently verified claims and deterministic aggregation improve the safety-coverage frontier. The additional rebuttal analyses resolve the main concerns underlying my initial recommendation, while the remaining limitations principally constrain the scope of the claims rather than invalidate the contribution. I therefore recommend acceptance as a poster. \n\nFinally, the reference “3d-RAD: A comprehensive 3d radiology med-VQA dataset with multi-temporal analysis and diverse diagnostic tasks” was flagged because the publication year is incorrect. The authors must correct this reference in the final version."+ },+ "createdAt": "2026-09-24T11:21:53.595Z",+ "modifiedAt": "2026-11-18T14:55:47.184Z",+ "url": "https://openreview.net/forum?id=jPgQvPpJTX¬eId=FFWwgPJ5kx",+ "license": "CC-BY-4.0"+}
reviews/openreview/jpgqvppjtx/notes/iogsh4smcl.json added
+++ b/reviews/openreview/jpgqvppjtx/notes/iogsh4smcl.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "ioGsH4smCl",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer of7B",+ "content": {+ "summary": "This study targets selective answering in medical VQA, where models abstain when the image evidence is insufficient to support the question. The authors propose PICV, which decomposes a question into atomic visual claims, including entity presence, body region, and answer choice validity. Each claim is then verified using an isolated prompt, and the results are combined through a rule-based decision process. The system outputs either an answer or an abstention, along with a supporting rationale.\n\nThe evaluation uses a benchmark constructed by deterministically corrupting instances from SLAKE and VQA-RAD (100 instances each) along three axes: image mismatch, question corruption, and choice removal. Across four VLM backbones (Gemini, GPT-5.4-mini, MedGemma-4B, and Qwen2.5-VL-7B), PICV achieves the highest AnsF1 in 7 out of 8 settings, with gains of +0.6 to +9.6 percentage points over the strongest baseline.\n\nThe contribution is use-inspired, targeting clinical safety in radiology VQA.",+ "contribution_type": "use_inspired",+ "strengths_and_weaknesses": "Strengths\n1. **Well-identified failure mode with empirical evidence**. The paper documents a concrete, quantifiable failure: the single-judge variant produces zero REFUTED verdicts for choice or region claims across 200+ missed unanswerable cases. This observation makes the study motivation direct and clearly linked to clinical meaning. \n2. **Cross-backbone consistency**. PICV is tested on four meaningfully different backbones: two frontier APIs and two on-premise models including a medical-domain-specialized VLM. The consistent improvement direction (7/8 cells) with statistical confirmation (sign test p=0.035, Wilcoxon p=0.016) strengthens the generalizability claim. The finding that MedGemma-4B exhibits the same systematic failure to abstain as general-purpose VLMs is an independently valuable observation.\n\nWeakness\n1. **Benchmark-method alignment inflates apparent gains**. The benchmark tests exactly the three failure types that PICV is built to catch: wrong body region, missing entity, and invalid answer choices. Each corruption type has a matching PICV verifier designed to detect it, while the baselines have no such specialized detectors. This makes the comparison inherently favorable to PICV. The method may not perform as well on real-world unanswerable cases that don't fit these three categories, such as poor image quality or ambiguous clinical questions. The authors acknowledge the benchmark is synthetic but don't flag this structural alignment.\n2. **No answer accuracy evaluation**. AnsF1 measures only the binary answer/abstain decision. The paper never reports whether the answers produced by A4 (when d=ANSWER) are actually correct.\n3. **Small benchmark size limits statistical precision**. Each dataset has only 100 instances (50 answerable + 50 unanswerable). On SLAKE, which uses three corruption axes, each axis has 17 unanswerable instances. Per-corruption TAR values computed from 17 samples have substantial sampling uncertainty (~±10–15 pp for proportions). The cross-cell sign test has very low power at n=8. No bootstrap confidence intervals are reported at the per-cell level.",+ "quality": 3,+ "clarity": 3,+ "significance": 2,+ "originality": 2,+ "questions": "1. The central thesis is that deterministic aggregation outperforms LLM-based aggregation. Can you run an ablation using the same A0–A2 decomposition and verification but replacing A3 with a lightweight LLM judge that receives all verdicts? This would directly isolate the aggregation mechanism from the decomposition design. \n2. Can you report accuracy of A4’s answers on the answerable subset where d=ANSWER? A system that correctly decides to answer but produces wrong answers is not useful for clinical deployment.\n3. Given that image_mismatch detection is essentially non-functional on SLAKE, would the authors report PICV results with image_mismatch instances excluded from the SLAKE benchmark to show performance on the corruption types where PICV is actually operative?",+ "limitations": "The authors provide a thorough limitations discussion. Three remaining gaps: \n1) The structural alignment between the benchmark’s corruption axes and PICV’s verifier types is not explicitly acknowledged as a limitation, even though it represents the most significant threat to generalizability. \n2) The absence of an evaluation of answer accuracy is not mentioned.\n3) There are missing ablation studies to test whether deterministic aggregation outperforms LLM-based aggregation, and whether question-blind grounding effectively prevents entity inflation.",+ "rating": 4,+ "confidence": 5,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No formatting concerns.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The rebuttal addresses all three major concerns with new experiments: a taxonomy-disjoint degradation condition, answer accuracy analysis, and the deterministic vs. LLM aggregator ablation. The appropriately narrowed claims and honest acknowledgment of limitations justify revising the score from 3 to 4."+ },+ "createdAt": "2026-06-26T03:53:27.954Z",+ "modifiedAt": "2026-11-18T13:40:29.299Z",+ "url": "https://openreview.net/forum?id=jPgQvPpJTX¬eId=ioGsH4smCl",+ "license": "CC-BY-4.0"+}
reviews/openreview/jpgqvppjtx/notes/uswtt2yaxp.json added
+++ b/reviews/openreview/jpgqvppjtx/notes/uswtt2yaxp.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "USwtT2YAXP",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer KNee",+ "content": {+ "summary": "This paper studies selective answering for medical visual question answering, where a model should answer only when the image provides sufficient evidence and abstain otherwise. The authors propose Parallel Independent Claim Verification (PICV), an inference-time framework that decomposes a medical VQA query into typed visual claims, verifies each claim independently using isolated prompts, and then applies a deterministic aggregation rule to decide whether to answer or abstain with a typed reason. The paper also constructs an answerability benchmark from public radiology VQA datasets using deterministic corruption procedures, including image mismatch, question corruption, and choice removal. Experiments on SLAKE and VQA-RAD with four vision-language model backbones show that PICV generally improves answerability F1 over direct answering, prompting-based abstention, and agentic verification baselines, while providing more transparent abstention reasons and lower inference cost than some multi-step agentic methods",+ "contribution_type": "use_inspired",+ "strengths_and_weaknesses": "Strengths:\n1. The paper addresses an important safety problem in medical VQA. The Introduction clearly explains that many Medical VQA systems assume every input is answerable, which may force models to produce confident answers even when the image lacks necessary evidence.\n2. The motivation is well grounded in a concrete failure mode. The paper argues that a confident wrong answer may be more harmful than refusal in clinical settings. This is a reasonable and clinically meaningful motivation.\n3. The deterministic aggregation step is a strength. Unlike single-judge agentic methods, PICV does not ask one VLM to combine all evidence into a final decision. Algorithm 1 specifies how verifier outputs are combined by rule.\n\nWeaknesses:\n1. The biggest quality concern is that the benchmark evaluates answerability, not full VQA correctness. The primary metric AnsF1 is defined over the answer/abstain decision. It does not directly evaluate whether the generated answer is medically correct when the model chooses to answer.\n2. The sample size is relatively small. Appendix A states that each backbone-dataset cell draws 50 answerable seeds and pairs them with 50 corrupted variants. This gives a clean benchmark, but the per-cell sample size may be too limited for broad claims about robust medical VQA behavior.\n3. The evaluation is restricted to two public English radiology datasets, SLAKE and VQA-RAD. Appendix E also acknowledges that pathology, fundus, non-radiology modalities, and broader population coverage are out of scope. This limits the significance for general medical VQA.",+ "quality": 3,+ "clarity": 2,+ "significance": 3,+ "originality": 3,+ "questions": "1. Can the authors evaluate final answer correctness on answerable cases, not only answerability F1? Since A4 generates an answer when PICV decides to answer, the paper should report whether those answers are medically correct.\n2. How well does PICV perform on naturally occurring unanswerable or ambiguous clinical questions, rather than synthetically corrupted inputs?\n3. How robust is the 60-entry entity-region table when moving beyond SLAKE and VQA-RAD? Does performance degrade when questions involve more fine-grained anatomy or pathology-specific entities?\n4. Can the authors compare against a fine-tuned abstention classifier or selective prediction baseline? This would clarify whether PICV’s advantage comes from its structure or from avoiding training.\n5. Can the authors provide more analysis of the weak image_mismatch TAR on SLAKE? Table 2 shows very low image_mismatch TAR in several SLAKE settings, which seems important for visual grounding.",+ "limitations": "Yes. The authors have addressed the limitations appropriately and have substantially narrowed the claims. A few limitations nevertheless remain. The evaluation is still relatively small and largely based on synthetic unanswerable cases from two English radiology VQA datasets, so robustness to naturally occurring clinical ambiguity and broader medical domains remains unverified. In addition, the manually constructed entity–region map has limited coverage, and some statistical analyses and clinician-adjudicated validation are deferred to the final version.",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No major formatting concerns.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "I appreciate the authors’ detailed rebuttal. The additional analyses address several of my main concerns, particularly regarding retained-answer accuracy, benchmark–method alignment, and deterministic aggregation. The revised framing around the safety–coverage trade-off is better supported and appropriately scoped. While some limitations remain, the new evidence improves my overall assessment. I have therefore revised my score from 3 to 4."+ },+ "createdAt": "2026-06-26T06:06:42.387Z",+ "modifiedAt": "2026-11-18T13:40:27.747Z",+ "url": "https://openreview.net/forum?id=jPgQvPpJTX¬eId=USwtT2YAXP",+ "license": "CC-BY-4.0"+}
reviews/openreview/jpgqvppjtx/notes/yxjlqsz9e6.json added
+++ b/reviews/openreview/jpgqvppjtx/notes/yxjlqsz9e6.json@@ -0,0 +1,31 @@+{+ "schema": "review/1",+ "id": "YxJLQSZ9e6",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Ci6h",+ "content": {+ "summary": "This paper studies selective answering for medical VQA, where a model must answer when the image supports the question and abstain when it does not. The authors argue that existing inference-time agentic verifiers underperform because they ultimately collapse all evidence into a single VLM judge that is biased toward declaring inputs answerable, overwriting strong negative signals from individual visual probes. They propose PICV (Parallel Independent Claim Verification), which decomposes a question into typed atomic visual claims, verifies each in isolation (no access to the question, the other verdicts, or any draft answer), and combines the verdicts with a deterministic programmatic rule that emits an answer/abstain decision together with a typed abstention reason. To score abstention without a VLM judge or human labels, the authors construct an answerability benchmark by deterministically corrupting answerable SLAKE/VQA-RAD instances along three axes (image mismatch, choice removal, question corruption). Across four VLM backbones, PICV attains the highest answerability-F1 in 7 of 8 cells, and ablations attribute the gains to per-claim isolation and rule-based aggregation rather than to agentic decomposition alone.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "## Strengths\n\n- Important, under-served problem (Significance). Abstention in medical VQA is safety-critical yet ignored by standard benchmarks that contain only answerable inputs. The paper targets exactly this gap.\n- Sharp diagnostic contribution (Quality/Originality). The \"single-judge supported bias\" — agentic verifiers produce per-probe negative evidence but collapse the final call into one biased VLM judge — is a genuine, useful observation. The statistic that this judge emits REFUTED zero times across 200+ missed unanswerable cases is crisp evidence.\n- Clean, well-motivated design (Quality). Replacing the judge with per-claim isolation plus a deterministic aggregation rule is a sensible architectural commitment. The typed abstention reasons are practically meaningful because they route to different downstream clinical actions.\n- Practical and reproducible (Quality). The method is no-fine-tuning and black-box-compatible, the benchmark construction is deterministic, and code is released. The ablations are honest and correctly localize the gain to per-claim isolation rather than decomposition itself.\n- Strong clarity. The paper is well-organized and Figures 1–2 communicate the corruption protocol and the pipeline cleanly.\n\n## Weakness\n\n- Limited conceptual novelty (Originality/Significance). Decompose-then-verify, parallel-vs-iterative verification, deterministic aggregation, and typed selective prediction are recombinations of existing inference-time patterns. The work reads as a careful engineering instantiation for one domain; the only fresh element is the supported-bias diagnosis, which is somewhat expected once stated.\n- Pareto claim without cost in the main result (Quality). Table 1 reports only answerability-F1, yet the headline advantage on frontier backbones is explicitly \"comparable accuracy at half the cost.\" Omitting the cost axis from the figure that makes the argument is not a defensible Pareto claim — a cost–quality scatter or an avg-calls/equal-budget column is needed.\n- Self-constructed benchmark co-designed with the method (Quality/fairness). The three corruption axes map almost 1:1 onto PICV's own typed reasons, while baselines do not share this taxonomy. This raises a construct-validity concern that the benchmark is not neutral with respect to the method being evaluated.\n- \"Exact\" labels are leaky (Quality). The authors admit SLAKE within-modality swaps share broad regions (abdomen/thorax), so the very low SLAKE image_mismatch true-abstain rates conflate label noise with model failure. A small clinician audit of ~50 \"unanswerable\" labels would settle this cheaply.\n- Overstated statistical strength. Each cell has only 100 samples (~17 per corruption type), so the large per-corruption deltas in Tables 2–3 (e.g. $+65$ pp) rest on tiny subsamples with no confidence intervals. The sign/Wilcoxon tests also treat 8 correlated cells as independent, making the $p$-values optimistic.\n- Concentrated, narrow gains (Significance). Tables 2–3 show the advantage is driven overwhelmingly by choice_missing (per-option MCQ verification), while image_mismatch is weak and question_corruption is SLAKE-only. An open-ended-only / excluding-choice_missing breakdown is needed to support the \"consistent across scenarios\" framing.\n- Compressed metric (Quality). Because each cell is balanced 50/50, a trivial \"always answer\" policy already scores $\\text{AnsF1}=0.667$ (recall $1.0$, precision $0.5$). Several PICV results ($0.70$–$0.78$) sit only marginally above this floor, so the absolute numbers overstate how much is actually being gained.\n- \"No fine-tuning\" understates the manual effort (Clarity). P2's ability to catch image_mismatch is bounded by a hand-built 60-entry entity-to-region table, not by the model. The paper frames PICV as \"no fine-tuning,\" but this hides a real component of dataset-specific knowledge engineering that performance depends on.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 2,+ "questions": "- Cost in the main table. Please add an avg-calls column (or AnsF1-vs-calls scatter) to Table 1, since the Pareto claim is central yet not directly shown — my score rises if the cost–quality position is visible per cell.\n- Benchmark neutrality. Your corruption axes map ~1:1 onto PICV's own typed reasons that baselines don't use, so please show PICV still wins on a corruption not aligned to its taxonomy — this is my main concern and a convincing answer would meaningfully raise my score.\n- Label validity. A ~50-case clinician audit of SLAKE image_mismatch \"unanswerable\" labels (which can share a broad region) would show how much the low TAR is label noise vs. model failure — score drops if many are actually answerable.\n- Where the gain comes from. Please report AnsF1 split by question type (or excluding choice_missing) to separate general selective answering from per-option MCQ verification — score rises if the advantage survives outside choice_missing.",+ "limitations": "None",+ "rating": 3,+ "confidence": 3,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes"+ },+ "createdAt": "2026-06-22T14:41:56.529Z",+ "modifiedAt": "2026-11-18T13:40:31.194Z",+ "url": "https://openreview.net/forum?id=jPgQvPpJTX¬eId=YxJLQSZ9e6",+ "license": "CC-BY-4.0"+}
reviews/openreview/jpgqvppjtx/submission.json added
+++ b/reviews/openreview/jpgqvppjtx/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "jPgQvPpJTX",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 17547,+ "url": "https://openreview.net/forum?id=jPgQvPpJTX",+ "license": "CC-BY-4.0"+}
versions/v_2x6fvqa2.json added
+++ b/versions/v_2x6fvqa2.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-03",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 17547,+ "url": "https://openreview.net/forum?id=jPgQvPpJTX",+ "reviews": "openreview/jpgqvppjtx",+ "evidence": [+ "https://openreview.net/forum?id=jPgQvPpJTX"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=jPgQvPpJTX",+ "evidence": [+ "https://openreview.net/forum?id=jPgQvPpJTX"+ ]+}