Update NeurIPS 2026 submission raQ4FzC3ZA: 3 notes
@openreview[bot] · 2026-11-24 15:56 UTC · 082689e4777c ·
reviews/openreview/raq4fzc3za/notes/1vxycdwdgw.json added
+++ b/reviews/openreview/raq4fzc3za/notes/1vxycdwdgw.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "1VxYcdWdgw",+ "replyTo": "dy8PxFq0NH",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "**Additional response to Q4 (Sensitivity to the observed frame index).** \n\nThank you for this valuable suggestion. We agree that the original random-frame evaluation does not directly isolate sensitivity to the observed cardiac phase. We therefore conduct an additional **phase-stratified evaluation** on EchoNet-Dynamic. All ECHO videos are temporally resampled to 125 frames. For each test subject, we evaluate four matched observation-phase settings using the same trained checkpoint and inference protocol, while changing only the observed frame and its temporal index. The ED/ES annotations are used only to define the phase groups for this analysis and are never provided to the model. Using circular temporal indexing, the four settings are defined as follows: \n\n- **near ED:** frames within ±2 frames of the annotated ED reference frame, yielding a five-frame window; \n\n- **near ES:** frames within ±2 frames of the annotated ES reference frame, also yielding a five-frame window; \n\n- **contraction:** intermediate frames after the near-ED window and before the near-ES window along the ED-to-ES trajectory; \n\n- **relaxation:** intermediate frames after the near-ES window and before the next near-ED window along the ES-to-ED trajectory.\n\n**Table R4. Sensitivity to the observed-frame phase on EchoNet-Dynamic.**\n\n| Observed-frame phase | PSNR ↑ | FVD ↓ | EF MAE ↓ |\n| :--- | :---: | :---: | :---: |\n| near ED | 27.92 | 128.92 | 4.10 |\n| near ES | 27.84 | 135.04 | 4.08 |\n| contraction | 27.72 | 140.57 | 4.23 |\n| relaxation | 27.68 | 144.82 | 4.26 |\n| Random observation | 27.73 | 137.70| 4.17 |\n\nNear-ED and near-ES observations perform slightly better than contraction and relaxation observations. This ordering is qualitatively consistent with the Trajectory Sufficiency Principle, since motion-extremal states provide stronger constraints on the cardiac trajectory than intermediate phases. Nevertheless, the maximum variation remains small, only 0.24 dB in PSNR, 15.9 in FVD, and 0.18 in EF MAE, indicating that phase conditioning and two-stage anchoring largely compensate for less informative observation positions.\nThese findings are **consistent with the trajectory-sufficiency intuition** while demonstrating that CardioFAD has only **limited sensitivity to the observed-frame phase**. We will add this analysis to the **Appendix** *Sensitivity to the observed frame index*.\n\n---\n\nWe hope these additions address the remaining concerns, and we are happy to provide further analysis during the discussion period. We sincerely appreciate the constructive feedback, which has helped strengthen our manuscript."+ },+ "createdAt": "2026-07-29T01:02:03.384Z",+ "modifiedAt": "2026-11-19T16:46:42.459Z",+ "url": "https://openreview.net/forum?id=raQ4FzC3ZA¬eId=1VxYcdWdgw",+ "license": "CC-BY-4.0"+}
reviews/openreview/raq4fzc3za/notes/ccdjevtd4x.json modified
+++ b/reviews/openreview/raq4fzc3za/notes/ccdjevtd4x.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 5Kw1","content": {- "metareview": "CardioFAD synthesizes cardiac dynamics from a single visual observation by learning motion-salient keyframes, aligning them with ECG or phase guidance, and generating the sequence in two diffusion stages. It reports consistent gains on CMR and ECHO datasets. The Focus–Align–Diffuse decomposition is clear, and the diagnostic analyses and learned keyframe alignment provide stronger evidence than a standard aggregate comparison alone.\n\nThe remaining questions are:\n\n1. On the ECHO datasets, the pseudo-ECG appears to be a patient-independent phase template. Separate gains from genuine patient-specific ECG information from those due to a generic phase prior and two-stage anchoring, and clarify which experiments support the ECG-aware claim.\n2. Clarify the intended clinical use of one-frame ECHO synthesis and the evidence for clinical fidelity. Discuss whether pathology-specific motion is preserved and how applying an EF regressor trained on real videos to generated videos affects interpretation. The paper should not imply diagnostic validity beyond the available evidence.\n\n If the role of ECG is established and the clinical claims are appropriately scoped, I would be ready to support acceptance."+ "metareview": "CardioFAD synthesizes cardiac dynamics from a single visual observation by learning motion-salient keyframes, aligning them with ECG or phase guidance, and generating the sequence in two diffusion stages. It reports consistent gains on CMR and ECHO datasets. The Focus–Align–Diffuse decomposition is clear, and the diagnostic analyses and learned keyframe alignment provide stronger evidence than a standard aggregate comparison alone.\n\nThe remaining questions are:\n\n1. On the ECHO datasets, the pseudo-ECG appears to be a patient-independent phase template. Separate gains from genuine patient-specific ECG information from those due to a generic phase prior and two-stage anchoring, and clarify which experiments support the ECG-aware claim.\n2. Clarify the intended clinical use of one-frame ECHO synthesis and the evidence for clinical fidelity. Discuss whether pathology-specific motion is preserved and how applying an EF regressor trained on real videos to generated videos affects interpretation. The paper should not imply diagnostic validity beyond the available evidence.\n\n If the role of ECG is established and the clinical claims are appropriately scoped, I would be ready to support acceptance.",+ "final_justification": "The reviewers were generally positive, with two Accept and one Borderline Accept rating. The rebuttal adequately distinguishes patient-specific ECG gains on UKBB from generic phase guidance on ECHO, strengthens the robustness and functional-consistency evaluations, and appropriately limits the clinical claims. The remaining limitations are clearly acknowledged and do not outweigh the technical contributions. I therefore recommend acceptance."},"createdAt": "2026-07-22T14:35:30.194Z",- "modifiedAt": "2026-11-18T15:22:10.560Z",+ "modifiedAt": "2026-11-19T05:01:18.822Z","url": "https://openreview.net/forum?id=raQ4FzC3ZA¬eId=ccdjEvTd4X","license": "CC-BY-4.0"}
reviews/openreview/raq4fzc3za/notes/putp9u1cyl.json added
+++ b/reviews/openreview/raq4fzc3za/notes/putp9u1cyl.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "PUTP9u1CYl",+ "replyTo": "ccdjEvTd4X",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "General Response",+ "comment": "# General Response\n\nWe sincerely thank the AC and all reviewers for their careful evaluation and constructive feedback. The meta-review identifies two remaining conditions concerning **the attribution of ECG-related gains** and **the clinical use and scope of clinical-fidelity claims**. Below, we map each condition to the corresponding new evidence and planned manuscript revisions.\n\nWe believe these additions **directly respond to the two remaining questions** identified in the meta-review by establishing the role of ECG and appropriately scoping the clinical claims.\n\n---\n\n## I. Shared Strengths\n\n- **Important problem and formulation** *(AC, AU6p, 7WCE)*\n- **Clear Focus–Align–Diffuse design** *(AC, 7WCE)*\n- **Strong controlled and diagnostic evidence** *(AC, EPkX, 7WCE)*\n- **Broad evaluation across CMR and ECHO** *(AC, AU6p)*\n\n---\n\n## II. Responses to key concerns\n\n| Key concerns | Reviewers | New evidence and response | Commitment to revision |\n| :--- | :---: | :--- | :--- |\n| **Attribution of ECG-related gains.** Separate patient-specific ECG information from generic phase guidance and two-stage anchoring. | **AC-1**; AU6p-Q2; EPkX-Q1; 7WCE-Q1 | On UKBB, paired ECG improves PSNR from **29.24 with null ECG to 32.41**, while correct subject pairing adds **+1.29** dB over shuffled ECG. On ECHO, correct phase guidance and two-stage anchoring each outperform their matched controls. Thus, **patient-specific ECG utility is supported only on UKBB; ECHO supports generic phase guidance and two-stage anchoring**. | Restrict patient-specific ECG claims to UKBB and describe ECHO consistently as phase-guided in the **Abstract, Problem Formulation, Contributions, dataset-specific terminology, Conclusion, and Limitations**. |\n| **Clinical use and scope of clinical-fidelity claims.** Clarify the ECHO use case, pathology-specific motion, and interpretation of EF evaluation. | **AC-2**; AU6p-Q1/Q3; EPkX-Q3; 7WCE-Q3 | CardioFAD is intended for extreme sparse-observation reconstruction and data-centric applications, **not routine cine replacement or standalone diagnosis**. On EchoNet-Dynamic, the real-video oracle and CardioFAD achieve EF MAEs of **3.96 and 4.17**, with a paired Gen–Real bias of **0.26**. Direct motion analysis also improves area-curve MAE from **0.063 to 0.048**, supporting preservation of functional and regional-motion differences. | Present EF only as a **functional-consistency proxy**, add the EF-credibility and pathology-specific analyses, and explicitly remove implications of standalone diagnostic validity. |\n\n---\n\nWe again sincerely thank the AC and all reviewers for their thoughtful and constructive guidance."+ },+ "createdAt": "2026-07-29T19:10:55.333Z",+ "modifiedAt": "2026-11-19T16:46:42.465Z",+ "url": "https://openreview.net/forum?id=raQ4FzC3ZA¬eId=PUTP9u1CYl",+ "license": "CC-BY-4.0"+}