Update NeurIPS 2026 submission D0DvVACDW0: 9 notes
@openreview[bot] · 2026-11-24 15:47 UTC · 8930b89951c4 ·
reviews/openreview/d0dvvacdw0/notes/2f5et134fq.json added
+++ b/reviews/openreview/d0dvvacdw0/notes/2f5et134fq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "2F5ET134FQ",+ "replyTo": "QT5XTuTBuP",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Area Chair eEYH",+ "content": {+ "comment": "Thank you for the additional comparison. The distinction between VIG as a zeroth-order prediction signal and ViCoR as a first-order optimization signal is clear. However, this distinction alone does not establish why the more expensive ViCoR is needed.\n\nThe empirical results show mixed advantages: ViCoR performs better on three external benchmarks and the average, but VIG is better on GMAI-MMBench and on both multi-disease metrics. Given that ViCoR requires two backward passes per sample and introduces several additional components, the current results do not demonstrate a clear cost–performance advantage over VIG. Moreover, the comparison conflates the scoring criterion with the training intervention: VIG uses token-level loss masking, whereas ViCoR uses supervision calibration and diversity-aware reranking. Therefore, the observed differences cannot yet be attributed specifically to the first-order gradient residual. The explanations regarding broader generalization and compositional pathology signals are also speculative without further analysis.\n\nUltimately, VIG is a highly relevant and important prior work. The paper must provide a detailed discussion of its relationship to and differences from VIG, rather than leaving this comparison only in the rebuttal. Since NeurIPS does not allow manuscript revisions during the rebuttal period, there is currently no way to ensure that this essential discussion will be incorporated into the paper. This remains a significant concern in my evaluation."+ },+ "createdAt": "2026-08-02T06:32:39.976Z",+ "modifiedAt": "2026-11-19T17:12:21.604Z",+ "url": "https://openreview.net/forum?id=D0DvVACDW0¬eId=2F5ET134FQ",+ "license": "CC-BY-4.0"+}
reviews/openreview/d0dvvacdw0/notes/dslgfje7gw.json added
+++ b/reviews/openreview/d0dvvacdw0/notes/dslgfje7gw.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "DsLgfJe7Gw",+ "replyTo": "2F5ET134FQ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the response and clarification. We agree that VIG is highly relevant and will include a detailed comparison and discussion in the revised manuscript."+ },+ "createdAt": "2026-08-02T09:25:35.187Z",+ "modifiedAt": "2026-11-19T17:12:21.696Z",+ "url": "https://openreview.net/forum?id=D0DvVACDW0¬eId=DsLgfJe7Gw",+ "license": "CC-BY-4.0"+}
reviews/openreview/d0dvvacdw0/notes/hh8jkc8znt.json added
+++ b/reviews/openreview/d0dvvacdw0/notes/hh8jkc8znt.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Hh8jKC8ZNt",+ "replyTo": "yJ2G8MXLyf",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the constructive comments and positive feedback. We provide the following clarifications.\n\n**W1. Random versus Full.** This reversal occurs only for Qwen3-VL-4B/CXR-Single: Random 62.07 versus Full 61.63 (+0.44), with overlapping bootstrap CIs. Random is below Full in the other five settings, while ViCoR reaches 65.29 here. We therefore treat it as a close exception, not evidence that Random generally outperforms Full. It does not indicate an experimental failure, since all methods use the same training and evaluation configuration. \n\n**W2. 50% budget.** We used 5%, 10%, 20%, and 40% as a conventional sweep to test robustness and the efficiency/performance tradeoff. At the added 50% point: Random 61.80, GraNd 62.98, LESS 62.59, Self-Filter 62.62, Adapt-∞ 61.92, and ViCoR 63.65. ViCoR remains highest by 0.67. It leads at 20%, 40%, and 50%, making 20% the smallest leading tested budget and our most data-efficient choice.\n\n**W3. Subgroups and worst-group performance.** Thank you for raising this point. Preventing subgroup failure is the central goal of this work, so we demonstrate it using the better subset selected by ViCoR. Correspondingly, the unselected subset is the poorer-performing subset, so we did not discuss it separately.\n\n**Q1. MIRAGE.** Thank you for pointing us to *MIRAGE: The Illusion of Visual Understanding*. Its analysis of apparently correct answers without genuine visual use is relevant to our motivation. We will add a discussion of this work.\n\n**Q2. Alternative shortcut controls.** The purpose of this experiment may have been misunderstood. It is a robustness test showing that different treatments of the region containing pathological evidence do not change ViCoR’s ranking or conclusion. Across these treatments, the conclusion remains the same: once the model cannot access the key pathological region, performance declines. We will clarify this purpose."+ },+ "createdAt": "2026-08-01T02:44:30.280Z",+ "modifiedAt": "2026-11-19T17:12:21.397Z",+ "url": "https://openreview.net/forum?id=D0DvVACDW0¬eId=Hh8jKC8ZNt",+ "license": "CC-BY-4.0"+}
reviews/openreview/d0dvvacdw0/notes/kzqnktd4o2.json added
+++ b/reviews/openreview/d0dvvacdw0/notes/kzqnktd4o2.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "kZqnKtD4o2",+ "replyTo": "RSbJ0cmI5x",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer yM3r",+ "content": {+ "comment": "I thank the authors for the thoughtful response. The softening of causal claims in W2 and the honest acknowledgment of transfer limitations in W3 are appreciated. However, Q1 remains only partially addressed. The rebuttal restates the motivation for the full pipeline but does not provide the direct comparison with simpler residual-only selection that would isolate the marginal value of each component beyond the ablation already in the paper. The grounding evidence cited for Q2 is reasonable but drawn from the same analyses already present, rather than new validation. Overall a fair response, but the core question of how much the full pipeline adds over the counterfactual residual alone is not fully resolved. I maintain my score."+ },+ "createdAt": "2026-08-02T02:33:08.450Z",+ "modifiedAt": "2026-11-19T17:12:21.395Z",+ "url": "https://openreview.net/forum?id=D0DvVACDW0¬eId=kZqnKtD4o2",+ "license": "CC-BY-4.0"+}
reviews/openreview/d0dvvacdw0/notes/qt5xtutbup.json added
+++ b/reviews/openreview/d0dvvacdw0/notes/qt5xtutbup.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "QT5XTuTBuP",+ "replyTo": "WZlksTeSNn",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for pointing us to this relevant work, which was published after we had begun our work and had therefore escaped our attention. We now provide additional theoretical analysis and an empirical comparison.\n\n**Theoretical comparison.** Both VIG and ViCoR are data-centric approaches to VLM training. Both compare the original image with a degraded or controlled visual input to estimate the contribution of vision beyond textual cues, prioritize visually dependent supervision under a fixed data budget, and reduce language-shortcut learning without changing the model architecture. However, they differ in their estimands and training interventions. VIG is a zeroth-order prediction signal based on the answer-token loss or perplexity reduction from a blurred image to the original image. It ranks samples and masks the training loss to high-VIG answer tokens. ViCoR is a first-order optimization signal based on the residual between original-image and mean-image-control gradients in the trainable parameter space. It further models shortcut pressure and residual direction, calibrates medical supervision, and reranks for diversity while leaving the subsequent SFT objective unchanged. We will add this distinction to the revised discussion.\n\n**Empirical comparison.**\n\nUnder the comparison setting, both methods use Qwen3-VL-4B as the backbone, GEMeX-ThinkVG as the training pool, a 20% data budget, and the same fine-tuning recipe. Results are reported on the same benchmark suite.\n\n| Method | OmniMedVQA | GMAI-MMBench | MedBLINK | DrVD-Bench | Avg. | Multi-Disease Acc. | Multi-Disease Macro-F1 |\n| :------: | :---------: | :-----------: | :--------: | :---------: | :--------: | :-----------------: | :---------------------: |\n| VIG | 81.94 | **53.34** | 59.78 | 60.21 | 63.82 | **49.17** | **49.03** |\n| ViCoR | **85.16** | 51.56 | **63.68** | **61.49** | **65.47** | 46.84 | 46.65 |\n\nThese results show complementary strengths rather than uniform dominance. ViCoR is stronger on three of four external benchmarks and the overall average, suggesting that its gradient-level residual and diversity-aware selection favor broader cross-benchmark generalization. VIG is stronger on GMAI-MMBench and the multi-disease evaluation, suggesting that its token-level information-gain objective may better preserve some reasoning-intensive or compositional pathology signals. The two methods capture different aspects of visual dependence, and their relative advantages vary across evaluated capabilities."+ },+ "createdAt": "2026-08-01T02:44:09.719Z",+ "modifiedAt": "2026-11-19T17:12:21.562Z",+ "url": "https://openreview.net/forum?id=D0DvVACDW0¬eId=QT5XTuTBuP",+ "license": "CC-BY-4.0"+}
reviews/openreview/d0dvvacdw0/notes/rsbj0cmi5x.json added
+++ b/reviews/openreview/d0dvvacdw0/notes/rsbj0cmi5x.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "RSbJ0cmI5x",+ "replyTo": "PszLlyheq7",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the constructive comments and positive feedback. We provide the following clarifications.\n\n**W1&Q1. Research significance and novelty.** ViCoR reframes medical VLM selection around modality competition: it selects samples by non-redundant visual contribution to prevent text-easy supervision from starving visual learning. The technical novelty is the counterfactual residual in trainable parameter space. Proxy comparisons and ablations support the full design.\n\n**W2. Counterfactual-input robustness and interpretation.** Appendix E replaces the mean image with blank, shuffled, and wrong images. Stable rankings show the result is not tied to one control. This cannot eliminate all shift or prove causality. We will therefore call ViCoR an optimization-level proxy for conditional image contribution and soften stronger claims.\n\n**W3. Independent grounding evidence.** This is the role of our mechanism analyses, which we will signpost more clearly. Before fine-tuning, Table 9 compares ViCoR with an independently constructed no image and wrong image loss target and gives the best AUC/Precision@20%. Table 11 uses evidence-box annotations and finds the highest retention of small, peripheral, and hard evidence. Figure 3 then masks annotated evidence against matched background, yielding a 9.4-point gap with 95% CI [3.2, 9.6]. These behavioral and annotation-linked tests support correspondence with visual grounding.\n\n**Q2. Beyond the shared-correct subset.** We used the same 362 initially correct cases to keep case composition identical across methods. All-correct examples per model would increase coverage but use different case sets, while failure cases require probability-shift rather than accuracy-drop analysis. We have not tested another localization-annotated dataset and will evaluate these extensions in future work.\n\n**Q3. Transfer.** The residual equations require only gradients over the fine-tuned parameters and therefore apply to larger VLMs. The medical calibration can be adapted or replaced for less structured domains. Consistency across two backbones, three training sources, and configuration/control perturbations makes larger-scale transfer plausible, but does not prove it. Because of review-time and compute constraints, we did not test larger models. We will test these settings in future work."+ },+ "createdAt": "2026-08-01T02:44:33.150Z",+ "modifiedAt": "2026-11-19T17:12:21.441Z",+ "url": "https://openreview.net/forum?id=D0DvVACDW0¬eId=RSbJ0cmI5x",+ "license": "CC-BY-4.0"+}
reviews/openreview/d0dvvacdw0/notes/wzlkstesnn.json modified
+++ b/reviews/openreview/d0dvvacdw0/notes/wzlkstesnn.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair eEYH","content": {- "metareview": "The paper is well motivated, clearly written, and supported by extensive experiments across multiple backbones, benchmarks, and ablations. The gradient residual formulation is intuitive, and the perturbation studies provide evidence that ViCoR improves visual dependence.\n\nThe largest concern is the insufficient discussion and comparison with the existing Visual Information Gain (VIG) [1] based selection method. Since both methods aim to identify visually necessary samples, the paper should clearly distinguish their motivations, technical differences, and empirical advantages. The absence of VIG-related analysis makes it difficult to evaluate the novelty and unique contribution of ViCoR.\n\n[1] Focusing Where Vision Matters: Selective Training for Large Vision Language Models via Visual Information Gain."+ "metareview": "The paper is well motivated, clearly written, and supported by extensive experiments across multiple backbones, benchmarks, and ablations. The gradient residual formulation is intuitive, and the perturbation studies provide evidence that ViCoR improves visual dependence.\n\nThe largest concern is the insufficient discussion and comparison with the existing Visual Information Gain (VIG) [1] based selection method. Since both methods aim to identify visually necessary samples, the paper should clearly distinguish their motivations, technical differences, and empirical advantages. The absence of VIG-related analysis makes it difficult to evaluate the novelty and unique contribution of ViCoR.\n\n[1] Focusing Where Vision Matters: Selective Training for Large Vision Language Models via Visual Information Gain.",+ "final_justification": "The paper proposes a first-order method and demonstrates its effectiveness on multiple datasets. One limitation is that the motivation does not clearly explain why the proposed first-order approach is necessary or preferable compared with zero-order methods. I recommend that the authors address this issue in the camera-ready version by providing a clearer justification."},"createdAt": "2026-07-22T08:02:37.330Z",- "modifiedAt": "2026-11-18T15:22:14.828Z",+ "modifiedAt": "2026-11-19T05:01:21.365Z","url": "https://openreview.net/forum?id=D0DvVACDW0¬eId=WZlksTeSNn","license": "CC-BY-4.0"}
reviews/openreview/d0dvvacdw0/notes/xdp6qjrbvu.json added
+++ b/reviews/openreview/d0dvvacdw0/notes/xdp6qjrbvu.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Xdp6qjRBvU",+ "replyTo": "UiGhsh9igO",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank you for the careful review and positive feedback on our work. We agree that several implementation and validation details should be stated more explicitly.\n\n**Q1&W3. CXR-CounterFact [33].** Counterfactual Preference Optimization (CPO) [33] uses generated counterfactual trajectories to separate beneficial from harmful drift in non-stationary preference tuning. ViCoR instead ranks a fixed pool through original-versus-mean-image gradients. CPO modifies tuning to manage drift, whereas ViCoR selects K examples for unchanged SFT and uses CXR-CounterFact only as training data. They are different method classes. Thus CPO is not a like-for-like fixed-budget baseline.\n\n**Q2&W2. Capability-level reporting.** We acknowledge that averaging across the four benchmarks may obscure performance on individual capabilities. In the previous submission, we reported the mean value due to page constraints. Under the same fine-tuning protocol and a 20% selection budget, we report Qwen3-VL-4B results using GEMeX-ThinkVG as the training pool on two representative benchmarks: OmniMedVQA for medical VQA and DrVD-Bench for visual diagnostic reasoning. Representative original benchmark dimensions are shown below, and we will add the full results to the appendix.\n\n| OmniMedVQA (VQA) | ViCoR | Best fixed baseline | Δ |\n| :-----------------------------------------: | :---: | :-----------------: | :---: |\n| Modality / Fundus Photography | 86.88 | LESS 85.63 | +1.25 |\n| Modality / Ultrasound | 83.93 | Adapt-∞ 81.50 | +2.43 |\n| Question type / Anatomy Identification | 83.49 | GraNd 81.41 | +2.08 |\n| Question type / Other Biological Attributes | 86.34 | LESS 83.81 | +2.53 |\n\n| DrVD-Bench (reasoning) | ViCoR | Best fixed baseline | Δ |\n| :----------------------: | :---: | :-----------------: | :---: |\n| Task / View Recognition | 63.34 | GraNd 61.33 | +2.01 |\n| Task / Noise Recognition | 60.05 | LESS 59.33 | +0.72 |\n| Modality / Radiograph | 61.13 | Full 59.78 | +1.35 |\n| Modality / CT | 61.44 | Full 60.64 | +0.80 |\n\n **Q3. Image/text dependence and GEMeX.** The external benchmarks lack item-level labels declaring whether a question is image- or text-dependent. We assess this indirectly by comparing intact-image performance with no-image and wrong-image inputs: with text fixed, the intact-image gain indicates visual reliance. GEMeX is used for region masking because its evidence-box annotations enable controlled analysis and visualization of dependence on clinically relevant regions.\n\n **Q4. Cases requiring both modalities.** We do not assume that every case is diagnosable from the image alone, and the calibration does not rely on visual uncertainty. The benchmarks do not label a separate joint-required subset. However, all training and evaluation use joint image-text inputs. In medical tasks, text provides context, while subtle image findings often carry diagnostic evidence beyond superficial textual cues. ViCoR preserves this visual contribution when both modalities are needed rather than discounting text.\n\n**W1. Budget choice.** We used 5%, 10%, 20%, and 40% as a conventional sweep to test robustness and the efficiency/performance tradeoff. At the added 50% point: Random 61.80, GraNd 62.98, LESS 62.59, Self-Filter 62.62, Adapt-∞ 61.92, and ViCoR 63.65. ViCoR remains highest by 0.67. It leads at 20%, 40%, and 50%, making 20% the smallest leading tested budget and our most data-efficient choice. \n\n**W4. Protocol and terminology.** NM-Win adds no synthetic distractor: it compares the correct CheXbench option with the most clinically similar benchmark-provided incorrect option. We will frame Table 4 as a sanity check in ViCoR’s gradient space. We will define “ViCoR-selected 20%” as the final K=0.2N examples, explain “global normality cues” as diffuse image statistics/normal-class priors without lesion localization, and replace Fig. 2’s “same final answer” with “same supervised target.” \n\n**Related work, uncertainty, limitations, and code.** *The Illusion of Readiness in Health AI* reinforces our motivation to distinguish genuine visual-evidence use from textual shortcuts. We will add a discussion of this work. Appendix I reports benchmark-stratified bootstrap 95% CIs and paired intervals: four of six comparisons are clearly positive, while the two closest include zero. Full three-seed SDs were omitted from the main text due to space and will be added to the revised appendix. Appendix K discusses ViCoR’s limitations, including proxy and control assumptions, annotation coverage, computational scaling, and clinical deployment. To improve transparency and reproducibility, we will publicly release our scoring, selection, and training code with the corresponding configurations."+ },+ "createdAt": "2026-08-01T02:44:18.910Z",+ "modifiedAt": "2026-11-19T17:12:21.992Z",+ "url": "https://openreview.net/forum?id=D0DvVACDW0¬eId=Xdp6qjRBvU",+ "license": "CC-BY-4.0"+}
reviews/openreview/d0dvvacdw0/notes/xmh6oxkyk8.json added
+++ b/reviews/openreview/d0dvvacdw0/notes/xmh6oxkyk8.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Xmh6OXKyk8",+ "replyTo": "kZqnKtD4o2",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for the follow-up. We agree that our previous response did not present the direct residual-only comparison clearly enough for Q1, while our response to Q2 relied only on analyses already included in the paper. We provide the two direct results below.\n\n**Q1. Full ViCoR versus residual-only selection.** Appendix F, Table 8 reports this controlled comparison using Qwen3-VL-4B, GEMeX-ThinkVG, the same 20% budget, and the same fine-tuning recipe. “Residual Norm only” ranks samples solely by the magnitude of the counterfactual residual, without shortcut weighting, directional correction, thresholding, supervision calibration, or diversity-aware reranking.\n\n| Selector | OMVQA | GMAI | MBLK | DRVD | Avg. | Multi-disease Acc. | Multi-disease Macro-F1 |\n| --- | :---: | :---: | :---: | :---: | :---: | :---: | :---: |\n| Residual Norm only | 82.35 | 41.96 | 60.25 | 59.01 | 60.89 | 44.92 | 44.82 |\n| Full ViCoR | 85.16 | 51.56 | 63.68 | 61.49 | 65.47 | 46.84 | 46.65 |\n| Gain | **+2.81** | **+9.60** | **+3.43** | **+2.48** | **+4.58** | **+1.92** | **+1.83** |\n\nThus, the full pipeline improves over residual-only selection on every external benchmark, increasing the four-benchmark average by **4.58 points** and multi-disease Accuracy/Macro-F1 by **1.92/1.83 points**. Table 8 shows that neither proxy signals nor the reduced pipeline recover the full benefit of ViCoR.\n\n**Q2. Correspondence with independent visual-dependence evidence.** We evaluated an additional 1,200 GEMeX samples, separate from the 1,000 examples used in the original evidence-region audit. A positive behavioral response means that replacing the original image with a control increases the supervised rationale+answer loss. Because ViCoR selects the highest-ranked samples under a fixed budget, we compare the highest and lowest 20% by S_vis, matching the main selection budget.\n| Held-out validation | Lowest 20% | Highest 20% | Difference [95% CI] |\n| :---: | :---: | :---: | :---: |\n| Mean-image control, sample level | 42.1% | **65.4%** | **+23.3 pp [14.6, 32.1]** |\n| Blank-image control, sample level | 51.7% | **75.8%** | **+24.2 pp [15.8, 32.5]** |\n| Mean-image control, image level | 40.0% | **63.6%** | **+23.6 pp [14.7, 32.4]** |\n\n\nSamples in the highest S_vis group are therefore 23–24 percentage points more likely to exhibit increased supervision loss after sample-specific visual information is removed. The same separation holds under an alternative control and after aggregating repeated questions at the image level, providing direct held-out evidence that S_vis enriches for behaviorally visual-dependent examples."+ },+ "createdAt": "2026-08-02T06:14:46.620Z",+ "modifiedAt": "2026-11-19T17:12:21.991Z",+ "url": "https://openreview.net/forum?id=D0DvVACDW0¬eId=Xmh6OXKyk8",+ "license": "CC-BY-4.0"+}