potentialpaper

Rethinking CT Synthesis through Semantics-Structure Alignment

Update NeurIPS 2026 submission 8cb59z0dK9: 25 notes

@openreview[bot] · 2026-11-24 15:46 UTC · 6122bb359595 ·

Evidence

reviews/openreview/8cb59z0dk9/notes/0bo1rasblc.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/0bo1rasblc.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "0BO1rasBLC",
+ "replyTo": "B4u5XsxJ9j",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer FjxJ",
+ "content": {
+ "comment": "Thank you for the detailed rebuttal. Retracting the causal terminology and adding histogram-loss, mask-perturbation, downstream, and volumetric experiments substantially address my concerns. Before finalizing my assessment, I would appreciate clarification on a few points.\nPlease define the LF/HF errors, frequency cutoff, normalization, and the unit represented by ±. For mask robustness, were perturbations applied only at test time, and can you report the matched LDM result under coarse masks? Under 50% label drop, LS2 improves FID and slightly improves SSIM, but not PSNR, so the robustness claim should remain metric-specific.\nFor downstream segmentation, please state whether variability is across patients, organs, seeds, or slices, and provide a paired patient-level LDM versus LDM+LS2 comparison if possible. The explanations for synthetic-only outperforming real-only should be presented as hypotheses unless directly validated.\nFinally, a single-reader study and \\(p=0.0588\\) do not establish clinical equivalence or indistinguishability. Similarly, metrics computed from stacked 2D slices demonstrate volumetric fidelity but do not directly isolate inter-slice consistency. Please temper these conclusions accordingly. Subject to these clarifications, I am inclined to raise my assessment."
+ },
+ "createdAt": "2026-08-01T05:54:18.885Z",
+ "modifiedAt": "2026-11-19T17:15:26.732Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=0BO1rasBLC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/5wr1vnkrmz.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/5wr1vnkrmz.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "5WR1vNkRMz",
+ "replyTo": "h3BoCYS1dc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Major concern2 in meta review: segmentation protocol and results interpretation",
+ "comment": "We will clarify the downstream segmentation protocol, discuss why synthetic-only training may outperform real-only training, and clarify Dice-IoU relationship.\n\nSegmentation experiments used the same patient-wise split as synthesis **(90/20/10 for train/val/test on SegRap), with no patient overlap**. All segmentation models were trained and validated solely on synthetic CTs paired with real masks. The **same patients, masks, and sample sizes** were used across all segmentation experiments. Evaluation was conducted exclusively on real CTs and real masks from unseen test patients. Therefore, this is a synthetic-to-real evaluation rather than a real-data augmentation setting.\n\n**Why synthetic-only outperformed real-only**: **(1) Synthetic CTs are more standardized**, with less scanner noise, acting as regularization. (2) Real CTs and manual annotations may have boundary misalignment, while **synthetic CTs provide more label-consistent training pairs**. Importantly, we do not claim that synthetic data are superior to real data. LDM data generated with LS2 achieved better performance on the independent real test set, indicating improved synthetic-to-real transfer utility. Nevertheless, the experiment was conducted on only 10 test patients from the single-center SegRap dataset. The result should therefore be interpreted cautiously and larger multi-center studies are required for synthetic and real comparison.\n\n**As for Dice-IoU relationship**, our averaging scheme is: Dice and IoU were first computed independently for each organ on each 2D slice. The slice-level values were then macro-averaged (weighted equally regardless of region size) within each organ, followed by macro-averaging across organs to obtain the reported mean Dice and mean IoU. **The nonlinear Dice–IoU conversion ($IoU_i = Dice_i/2-Dice_i$) holds per sample, but not after macro-averaging**: $$ \\\\frac{1}{N}\\\\sum_{i=1}^{N} IoU_i \\\\neq \\\\frac{ \\\\frac{1}{N}\\\\sum_{i=1}^{N} Dice_i }{ 2-\\\\frac{1}{N}\\\\sum_{i=1}^{N} Dice_i } $$\n\nFor example, consider two slices with Dice of 1.0 and 0.1. Their mean Dice is 0.55. The corresponding IoU are 1.0 and 0.0526, giving a mean IoU of 0.5263. In contrast, converting the mean Dice directly via IoU-Dice relationship would yield 0.55/(2−0.55)=0.3793. In this case, **the IoU-Dice relationship does not hold in the example you provided** about \"SpinalCord (Dice 0.55), Brain (Dice 0.71), mean Dice 0.910, and mean IoU 0.906\"."
+ },
+ "createdAt": "2026-07-29T01:25:10.062Z",
+ "modifiedAt": "2026-11-19T17:15:27.190Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=5WR1vNkRMz",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/74u0cofyx9.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/74u0cofyx9.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "74u0coFYx9",
+ "replyTo": "uvaDT5JlBP",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to question 2's flow models",
+ "comment": "Thank you for this helpful suggestion. We agree that the applicability conditions and scope of LS2 for different flow parameterizations should be stated more precisely in the manuscript. **To make this scope precise, we consider a family of affine conditional probability paths, of which the linear path is a special case.**\n\nFor an affine conditional flow with a known smooth scheduler and velocity prediction, the conditional probability path can be written as:\n$$X_t=\\alpha_t X_1+\\sigma_t X_0$$\nwhere $X_0$ denotes the clean image, $X_1$ denotes the other endpoint of the path, and $\\alpha_t$ and $\\sigma_t$ are known differentiable scheduling functions satisfying the corresponding boundary conditions, e.g.,\n$$\\alpha_0=0, \\sigma_0=1, \\alpha_1=1,\\sigma_1=0$$\nDifferentiating the path with respect to $t$ gives the pathwise velocity:\n$$V_t = \\frac{d X_t}{d t}=\\\\dot{\\\\alpha}_t X_1+\\\\dot{\\\\sigma}_t X_0$$\nwhere $\\\\dot{\\\\alpha}_t$ and $\\\\dot{\\\\sigma}_t$ are corresponding first-order derivatives with respect to $t$.\n\nGiven conditioning mask $M$, the corresponding ideal marginal velocity field is defined as\n$$u\\_t(x,M)=\\\\mathbb{E} [V_t\\\\mid X_t=x,M ] = \\\\mathbb{E} [\\\\dot{\\\\alpha}_t X_1+\\\\dot{\\\\sigma}_t X_0\\\\mid X_t=x,M ]$$\nHere, $X_0$, $X_1$, and $X_t$ denote random variables defined over the training-data and source-endpoint distributions, whereas $x_0$, $x_1$, and $x_t$ denote their particular realizations in a training iteration. The conditional expectation averages the pathwise velocities over the possible endpoint pairs $(X_0,X_1)$ that are consistent with the current state $X_t$ and the conditioning mask $M$.\n\nLet $\\\\theta(x\\_t,t,M)$ denote the marginal velocity field predicted by the mask-conditioned flow model for a particular sample $x_t$. Combining the affine path equation with the predicted velocity gives the following differentiable clean-image estimate:\n$$\\\\hat{x}_0=\\\\frac{ \\\\dot{\\\\alpha}_t x_t - \\\\alpha_t u\\_\\\\theta(x\\_t,t,M) }{ \\\\dot{\\\\alpha}_t\\\\sigma_t-\\\\alpha_t\\\\dot{\\\\sigma}_t }$$\nThis estimate is well defined when $\\\\dot{\\\\alpha}_t\\\\sigma_t-\\\\alpha_t\\\\dot{\\\\sigma}_t\\\\neq0$.\n\nUnder the ideal marginal velocity field, i.e., when $u_\\theta = u_t$, the resulting expression corresponds to a conditional-mean estimate of the clean endpoint:\n$$\\\\hat{x_0}=\\\\mathbb{E} [X_0\\\\mid X_t=x_t,M ]$$\nwhen the learned velocity $u_\\theta$ is used, it provides an approximate differentiable clean-image estimate to which LS2 can be applied.\n\nThe linear path used in Equation (12) is a special case of this formulation. Specifically, when $\\\\alpha_t=t, \\\\sigma_t=1-t$, we have $\\\\dot{\\\\alpha}_t=1,\\\\quad \\\\dot{\\\\sigma}_t=-1$ and the clean-image estimate simplifies to $\\\\hat{x}_0= x_t -t u\\_\\\\theta(x\\_t,t,M) $, which is exactly the form used in Equation (12).\n\nWe will revise the manuscript to make this requirement and its scope explicit. However, this analytical derivation should not be interpreted as empirical validation of LS2 for all affine schedules or flow parameterizations. Flow- and diffusion-based models that do not directly output an image prediction may adopt diverse probability paths, endpoint definitions, prediction targets, and parameterizations, including noise, velocity, score, and data prediction. Although LS2 may potentially be incorporated into these formulations when a valid differentiable clean-image estimate can be explicitly derived, each formulation requires parameterization-specific derivation and empirical validation.\n\nIn the present work, the clean-image estimation procedure and the effectiveness of LS2 were implemented and empirically validated only for the linear velocity-prediction flow formulation used in MOTFM and the noise-prediction LDM formulation. We therefore do not claim that the current derivations directly apply to all flow or LDM variants. We instead treat the above derivation as a theoretical grounding for the specific implementations used in our experiments. We will clarify this limitation in the revised manuscript and investigate extensions to other probability paths and prediction parameterizations in future work."
+ },
+ "createdAt": "2026-07-31T20:19:29.575Z",
+ "modifiedAt": "2026-11-19T17:15:26.772Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=74u0coFYx9",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/7rerkdx4jv.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/7rerkdx4jv.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "7Rerkdx4jV",
+ "replyTo": "0BO1rasBLC",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to the statement should be tempered",
+ "comment": "Thank you for this important clarification. We agree that several statements in the original manuscript were stronger than warranted by the current evidence, and we will revise them accordingly.\n\nFirstly, for why the synthetic-only model outperformed the real-only model, we will reframe these explanations as hypotheses. Second, we agree that the single-reader study and nonsignificant result (p=0.0588) does not establish clinical equivalence or indistinguishability between real and synthetic images. The revised manuscript will describe the reader study more cautiously. Finally, we agree that metrics calculated from stacked 2D slices primarily assess the fidelity of the reconstructed 3D volume as a whole, but do not directly isolate inter-slice consistency. We will revise the corresponding text to describe these results as evidence of volumetric fidelity rather than direct evidence of inter-slice consistency."
+ },
+ "createdAt": "2026-08-01T14:28:52.578Z",
+ "modifiedAt": "2026-11-19T17:15:26.579Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=7Rerkdx4jV",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/aiwie53bb5.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/aiwie53bb5.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "AiwIE53BB5",
+ "replyTo": "CxNWZOygzp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 4Kg1",
+ "content": {
+ "title": "Interpretation about frequency related to loss",
+ "comment": "I appreciate the authors providing LF and HR error (with equation).\n\nFor the contribution and interpretation of the losses in the frequency domain, the authors showed their effects empirically using LF/HF errors. Adding the table as an ablation study, together with the definitions of the LF/HF errors, would better demonstrate the contributions of the losses across different frequency bands. However, I believe the authors should still tone down the theoretical interpretation of this relationship. The new results provide useful empirical evidence, but they do not establish that minimizing SID mathematically implies low-frequency alignment."
+ },
+ "createdAt": "2026-08-03T06:13:09.851Z",
+ "modifiedAt": "2026-11-19T17:15:26.489Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=AiwIE53BB5",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/biyo7zymfh.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/biyo7zymfh.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "bIyo7ZymfH",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Area Chair LJw8",
+ "content": {
+ "title": "Final justification",
+ "comment": "The discussion period is coming to an end, and the next task **for all reviewers** is to make a final justification and possibly update the rating. (You can do so by selecting the review “Edit->Official Review” button. “Rating” changes during Phase 3 are not visible to authors until paper decisions are made visible.) \n\nIf you have any outstanding questions for the authors, now is the time."
+ },
+ "createdAt": "2026-08-03T12:01:17.466Z",
+ "modifiedAt": "2026-11-19T17:15:26.429Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=bIyo7ZymfH",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/dvfek9jqaz.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/dvfek9jqaz.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "dVFeK9JqAZ",
+ "replyTo": "Xg7k4ncsjt",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Major concern4 in meta review: integration details, sample diversity and robustness",
+ "comment": "We will add the integration details to the main text and provide analysis on mask diversity&robustness as follows.\n\n**Integration details**\n\nFor LDM, LS2 is computed in image space by a **frozen VAE** decoder and gradients pass through the decoder to the diffusion model. **VAE reconstruction is accurate** (AutoPET: MAE 0.0039, SSIM 0.9824, PSNR 36.97; SegRap: 0.0028, 0.9893, 38.52). However, frozen VAE errors remain. **Since the same VAE is used for baseline and LS2, comparisons are fair**. We will explicitly state that VAE reconstruction fidelity sets an upper bound for LS2 performance under LDM framework.\n\nIn order to **keep LS2 definition consistency and comparison fairness across all baselines**, we do not apply time-step weighting to diffusion or flow training based on clean-image estimate. Despite this, LS2 still improves results obviously (Table 1). \n\n**Multi-sample diversity**\n\nAs for multi-sample diversity, we will add diversity analysis in the revision. On AutoPET test set, we sampled 10 times per mask across head, chest, and abdomen using LDM and LDM+LS2, and computed LPIPS (perceptual diversity), (1−SSIM) (structural diversity), and HU-W1 (HU distribution diversity). \n\nLDM+LS2 reduced LPIPS from 0.0506±0.0195 to 0.0353±0.0148 and (1−SSIM) from 0.1314±0.0436 to 0.0948±0.0284. This is consistent with design of LS2 since it would reduce unstable visual and structural variations. However, diversity does not collapse. HU-W1 only decreased from 1.8949±0.5328 to 1.7671±0.3670, indicating intensity variations from random sampling are largely preserved. Visualizations confirm that unconstrained regions (e.g., muscle, soft tissue, boundary details) still vary reasonably. Since links for images are nor permitted here, figures will be in the revision. \n\nOverall, LS2 constrains organ-level distributions, not pixel-wise reconstruction, so it does not collapse one-to-many to one-to-one. The experiments confirm LS2 filters unanatomical variations while preserving stochasticity, achieving a favorable fidelity-diversity trade-off.\n\n**Robustness to noisy or coarse masks**\n\nAs for robustness to noisy or coarse masks, we further evaluated LS2 under incomplete and coarse conditioning masks on the AutoPET test set. And we will add the quantitative results and visual examples to the supplementary material. Two perturbations were considered: (1) randomly dropping 50% of organ labels to simulate incomplete annotations, and (2) downsampling masks by a factor of 2 and resizing them back to the original resolution to simulate coarse masks. \n\nAs expected, label removal degraded both models. Under 50% label drop, SSIM dropped for LDM (from 0.760±0.054 to 0.745±0.084) and LDM+LS2 (from 0.771±0.053 to 0.749±0.077); PSNR dropped from 23.247±2.492 to 22.845±2.683 and from 23.515±2.548 to 22.723±2.648, respectively. Visual inspection confirmed boundary misalignment in removed regions. \n\nNevertheless, **LDM+LS2 consistently achieved lower FID than LDM under this conditions**, 18.131±0.099 vs. 20.187±0.121 with complete masks, 21.973±0.189 vs. 24.586±0.210 with 50% label drop. This indicates that **LS2 preserves a distribution closer to real CT even when the conditioning masks are degraded**. \n\nAdditionally, **LS2 was particularly stable under coarse-mask perturbation**. LDM+LS2 achieved an SSIM of 0.768±0.047 and a PSNR of 23.517±2.573, close to its performance with complete masks (0.771±0.053 and 23.515±2.548). Overall, LS2 tolerates moderate boundary coarsening, although substantial label removal still degrades generation quality."
+ },
+ "createdAt": "2026-07-29T01:41:07.875Z",
+ "modifiedAt": "2026-11-19T17:15:27.062Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=dVFeK9JqAZ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/e6e4huuqce.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/e6e4huuqce.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "e6e4hUuqcE",
+ "replyTo": "AiwIE53BB5",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to reviewer 4Kg1",
+ "comment": "We thank the reviewer for the positive feedback and constructive suggestions.\n\n**Frequency-related interpretation.** We will add an ablation table with the definitions of LF/HF errors to better illustrate the frequency-band contributions of each loss. We also agree that the theoretical interpretation should be toned down. We will revise the manuscript accordingly.\n\n**Applicability statement.** We will rephrase (a) as future work, add (b) as a motivational statement for helping readers better understand the practical value of the method in the paper, and acknowledge (c) as limited to simulated mask degradations, with validation on real segmentation errors left for future work. Other applications are beyond this scope.\n\nWe sincerely appreciate the reviewer's time and insights, which have significantly strengthened our manuscript."
+ },
+ "createdAt": "2026-08-04T06:34:49.857Z",
+ "modifiedAt": "2026-11-19T17:15:26.408Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=e6e4hUuqcE",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/h1w1kzk1nq.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/h1w1kzk1nq.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "h1W1kzK1nq",
+ "replyTo": "0BO1rasBLC",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Downstream segmentation clarification",
+ "comment": "Thank you for this helpful suggestion. We will clarify the source of variability in the downstream segmentation experiment. The segmentation model was trained and evaluated on 2D slices, and the mean and standard deviation in the original results were calculated across slices. Therefore, **the reported variability reflected slice-level variation rather than variation across patients, organs, or random seeds**. We will explicitly state this in the revised manuscript.\n\nFollowing the reviewer’s suggestion, we further conducted a paired patient-level comparison between LDM and LDM+LS2. The two methods were evaluated using the same test patients and the same set of organs, thereby allowing direct pairing at the patient-organ level.\n\nSpecifically, for each patient, the ground-truth masks and segmentation predictions from the 2D slices were stacked to reconstruct a 3D volume. Metrics were then calculated separately for each organ within each patient-level 3D volume. For the organ-specific results, the mean and standard deviation were calculated across patients for the same organ. For the overall results, we first averaged the metrics across all organs for each patient and subsequently calculated the mean and standard deviation of these patient-level averages across the test cohort. Thus, **the variability in the newly added analysis reflects inter-patient variability rather than variability across slices or random seeds.**\n\n**In the paired evaluation of the same patients (Table 1 and 2 below)**, LDM+LS2 increased the overall Dice from 0.4765±0.0193 to 0.6022±0.0322 and the IoU from 0.3751±0.0182 to 0.4714±0.0300, compared with LDM. It also reduced HD95 from 4.7790±0.5811 to 3.7903±0.4388 mm and ASSD from 1.9145±0.3267 to 1.5178±0.2733 mm. Consistent numerical improvements were also observed for representative organs, including the left submandibular gland, brain, and spinal cord.\n\nWe will report these findings as consistent numerical improvements in a paired patient-level evaluation.\n\n**Table 1: Paired patient-level downstream segmentation performance using real, LDM-generated, and LDM+LS2-generated training data.**\n| Model | Mean Dice | Mean IoU | HD95 (voxel) | ASSD (voxel) | HD95 (mm) | ASSD (mm) |\n|---|---:|---:|---:|---:|---:|---:|\n| Real | $0.3591 \\pm 0.0392$ | $0.3036 \\pm 0.0192$ | $6.0969 \\pm 1.6045$ | $2.0958 \\pm 1.1711$ | $8.8589 \\pm 2.3314$ | $3.1293 \\pm 1.7486$ |\n| LDM | $0.4765 \\pm 0.0193$ | $0.3751 \\pm 0.0182$ | $3.2734 \\pm 0.4782$ | $1.2673 \\pm 0.2578$ | $4.7790 \\pm 0.5811$ | $1.9145 \\pm 0.3267$ |\n| LDM+LS2 | $0.6022 \\pm 0.0322$ | $0.4714 \\pm 0.0300$ | $2.6211 \\pm 0.4881$ | $1.0286 \\pm 0.2101$ | $3.7903 \\pm 0.4388$ | $1.5178 \\pm 0.2733$ |\n\n**Table 2: Paired patient-level Dice scores of representative organs using real, LDM-generated, and LDM+LS2-generated training data.**\n| Model | Submandibular-L | Brain | SpinalCord |\n|---|---:|---:|---:|\n| Real | $0.4494 \\pm 0.0994$ | $0.6527 \\pm 0.1693$ | $0.3794 \\pm 0.0823$ |\n| LDM | $0.5523 \\pm 0.1210$ | $0.9512 \\pm 0.0084$ | $0.6976 \\pm 0.0610$ |\n| LDM+LS2 | $0.6664 \\pm 0.0894$ | $0.9620 \\pm 0.0086$ | $0.7448 \\pm 0.0465$ |"
+ },
+ "createdAt": "2026-08-01T14:26:45.443Z",
+ "modifiedAt": "2026-11-19T17:15:26.598Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=h1W1kzK1nq",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/h3bocys1dc.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/h3bocys1dc.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "h3BoCYS1dc",
+ "replyTo": "odcshk33u2",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Major concern 1 in meta review: “causal” terminology and empirical observation of SID",
+ "comment": "We agree that \"causal perspective\" is inappropriate and will **drop it**. We will also **add data analysis and spectral validation of frequency improvement** to better support low-frequency claim in the revised manuscript.\n\nIntuitively, compared with arbitrary image patches, patches within anatomical masks exhibit more concentrated HU distributions and lower spatial intensity variation in CT. In AutoPET, organ-mask patches show substantially lower intensity variation (std: 48.53 vs. 157.15; IQR: 46.09 vs. 159.50; median absolute deviation: 20.35 vs. 37.42) and smaller gradient magnitudes (mean gradient: 12.68 vs. 22.31; total variation: 24.87 vs. 35.97) compared to random patches. This provides **empirical support for the link between organ-level distribution constraints and low-frequency consistency**. \n\nWe clarify that our claim is not that SID theoretically guarantees low-frequency alignment for all images. Rather, the **observed spectral improvements are an empirical byproduct of semantic-structural regularization on medical CT data**, where organ-level intensity distributions are inherently constrained.\n\n**As for additional spectral validation, we compared SID with the differentiable histogram loss in [1]** (suggested by reviewer 4Kg1), applied either globally or within organ masks under the same pix2pixHD settings in Table 1 of paper. The baseline low-frequency error (LF error) was 0.491±0.061. The global histogram loss reduced it to 0.480±0.062, whereas the organ-wise histogram loss further reduced it to 0.451±0.058. The high-frequency error (HF error) remained almost unchanged for the organ-wise histogram loss (0.416±0.042 vs. 0.418±0.043 for the baseline), while HU-W1 improved from 188.706±4.960 to 167.553±15.672. These results indicate that **organ-level intensity regularization improves low-frequency consistency, while global histogram constraints are less effective. **\n\nNotably, **SID produced a larger improvement compared to [1]**, reducing HU-W1 to 162.303±21.320 and LF error to 0.391±0.051, a reduction of approximately 20.4% from the baseline. Its HF error remained close to the baseline at 0.408±0.037, indicating that its main effect is organ-aware HU alignment accompanied by improved low-frequency spectral consistency, rather than uniform improvement across all frequency bands. In contrast, SA had little effect on the LF error but reduced the HF error to 0.295±0.013. Combining SID and SA, LS2 achieved LF and HF errors of 0.389±0.047 and 0.287±0.022, respectively, together with the best SSIM of 0.752±0.048 and the lowest HU-W1 of 159.242±4.668. Together, SID and SA are complementary. **SID targets organ-level intensity and low-frequency consistency, while SA enhances high-frequency structures; their combination yields the best overall performance.**\n\n$$\n\\\\begin{array}{ccccc}\n\\\\hline\nMethod & SSIM & HU-W1 & LF\\\\ error & HF\\\\ error \\\\\\\\\n\\\\hline\npix2pixHD & 0.719±0.057 & 188.706±4.960 & 0.491±0.061 & 0.418±0.043 \\\\\\\\\n[1]-organ & 0.710±0.053 & 167.553±15.672 & 0.451±0.058 & 0.416±0.042 \\\\\\\\\n[1]-global & 0.714±0.055 & 170.190±14.672 & 0.480±0.062 & 0.418±0.033 \\\\\\\\\nSID & 0.736±0.051 & 162.303±21.320 & 0.391±0.051 & 0.408±0.037 \\\\\\\\\nSA & 0.743±0.052 & 171.552±4.596 & 0.482±0.060 & 0.295±0.013 \\\\\\\\\nLS2 & 0.752±0.048 & 159.242±4.668 & 0.389±0.047 & 0.287±0.022 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\n*[1] M. Avi-Aharon, A. Arbelle, and T. Riklin Raviv, “Differentiable Histogram Loss Functions for Intensity-Based Image-to-Image Translation,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 45, no. 10, pp. 11642–11653, Oct. 2023, doi: 10.1109/TPAMI.2023.3278287.*"
+ },
+ "createdAt": "2026-07-29T01:16:12.849Z",
+ "modifiedAt": "2026-11-19T17:15:26.944Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=h3BoCYS1dc",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/jjxs9kjwho.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/jjxs9kjwho.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "jjxs9kjWHO",
+ "replyTo": "k5t2G2SuSR",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to question 2's clean-image estimate: part1",
+ "comment": "Thank you for this helpful suggestion. We agree that the stability of the losses and gradients across different diffusion timesteps should be analyzed. Accordingly, we divided the diffusion timesteps into low-noise [1,334), medium-noise [334,667), and high-noise [667,1000] intervals. Using checkpoints obtained during training on SegRap2023, we calculated the denoising loss, LS2, total loss, and their corresponding gradient norms within non-overlapping 10k training-step intervals.\n\nThe results demonstrate a timestep dependence of LS2. As the noise level increased, the PSNR of the clean-image estimate decreased from 34.321 in the low-noise interval to 32.982 and 28.125 in the medium- and high-noise intervals, respectively, indicating reduced reconstruction reliability. Consistent with this observation, both the absolute LS2 value and its gradient norm were larger in the high-noise interval, indicating that LS2 is more sensitive at high-noise timesteps (see Table 3 below).\n\nNotably, Table 3 shows that **the increased sensitivity at high-noise timesteps did not prevent the continued optimization of either LS2 or the original denoising objective.** Within the high-noise interval, the denoising loss decreased from 0.026030 ± 0.003173 in the first training interval to 0.009135 ± 0.001271 in the final interval, while LS2 decreased from 0.062312 ± 0.020588 to 0.021928 ± 0.007276 and the total loss decreased from 0.088342 ± 0.022105 to 0.031063 ± 0.007792. Meanwhile, the corresponding gradient norms remained finite and showed no persistent growth, despite local fluctuations. No NaN, Inf, or evident divergence was observed during training. Therefore, **although the clean-image estimate is less reliable and LS2 exhibits greater sensitivity at high-noise timesteps, this sensitivity did not prevent LS2 from decreasing or disrupt the stable reduction of the original denoising loss under the current experimental setting.**\n\nSimilar stable optimization behavior was observed in the low- and medium-noise intervals, as shown in Tables 1 and 2. Each loss progressively decreased during training. Their corresponding gradient norms remained finite and bounded. \n\nWe further examined **whether the greater sensitivity at high-noise timesteps translated into global optimization instability**. As shown in Table 4, we compared the original denoising losses of LDM and LDM+LS2 over the same training-step ranges. For each non-overlapping 10k training-step interval, we calculated the mean and standard deviation of the denoising loss. The original denoising loss decreased continuously for both models, from 0.122987±0.079875 to 0.034905±0.011420 for LDM and from 0.103973±0.056784 to 0.025865±0.007910 for LDM+LS2. LDM+LS2 exhibited a lower mean denoising loss in every reported interval. Overall, these results indicate that incorporating LS2 did not disrupt the global convergence behavior of the original diffusion objective or introduce persistent optimization instability in this experiment.\n\nAdditionally, we clarify that: (1) LS2 was originally designed and contributed as an image-space constraint for CT and first implemented with pix2pixHD; (2) in subsequent cross-framework experiments, we retained its original formulation without introducing framework-specific adaptations (e.g., timestep weighting for LDM); (3) While LS2 has show its effectiveness on different models, this leaves room for further framework-specific tuning. (4) For flow- and LDM-based models without direct image outputs, the applicable parameterizations vary; while LS2 may be extendable, each case requires formulation-specific derivation and validation. \n\nFuture work will investigate the extension of LS2 to other parameterizations, together with framework-specific strategies for better adapting LS2.\n\nWe sincerely thank the reviewer for this careful observation and constructive suggestion, which has helped us to improve the clarification on both the performance and the potential directions for improving LS2."
+ },
+ "createdAt": "2026-07-31T19:51:12.549Z",
+ "modifiedAt": "2026-11-19T17:15:26.823Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=jjxs9kjWHO",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/nnne4xmpsx.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/nnne4xmpsx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Nnne4xMpsx",
+ "replyTo": "0BO1rasBLC",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Clarification to perturbations experiment",
+ "comment": "Thank you for this careful comment. Yes, **all mask perturbations were applied only at test time**. Both LDM and LDM+LS2 were trained using the original, unperturbed masks. These perturbation experiments were intended to evaluate the models’ tolerance to degraded conditioning masks during inference, rather than explicit robustness acquired through perturbation-aware training. In future work, incorporating mask perturbation augmentation during training may help extend LS2 to scenarios involving lower-quality masks, which represents an important direction for further investigation.\n\nFollowing the reviewer’s suggestion, **we further added matched LDM baseline results under the coarse-mask setting**. Compared with the matched LDM baseline, LDM+LS2 improved SSIM from (0.759±0.057) to (0.768±0.047), increased PSNR from (23.240±2.513) to (23.517±2.573), and reduced FID from (18.256±0.101) to (15.169±0.103). These results indicate that **the performance advantages introduced by LS2 are retained under this degree of mask coarsening**.\n\n**We also agree with the reviewer that the results under 50% label drop should be interpreted in a metric-specific manner**. We will revise the corresponding statements in the manuscript to clarify that, under 50% label drop, LS2 improves FID and slightly improves SSIM, but does not improve PSNR."
+ },
+ "createdAt": "2026-08-01T14:25:20.783Z",
+ "modifiedAt": "2026-11-19T17:15:26.710Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=Nnne4xMpsx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/nzebbv7dqf.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/nzebbv7dqf.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "NzeBbv7Dqf",
+ "replyTo": "dVFeK9JqAZ",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Major concern5 in meta review: clarity and results presentation",
+ "comment": "Thank you for your suggestions. Firstly, we will revise Section 3.3 and state more plainly, like what we show in \"Response to major concern1 in meta review\". We will included data analysis and empirical results on spectral improvement for both SID and SA. Second, we will include a summary figure showing LS2 gains per backbone with values annotated, and revise the analysis to interpret numbers rather than just list them. Thirdly, we will move the diffusion/flow/VAE integration into main text."
+ },
+ "createdAt": "2026-07-29T01:44:47.317Z",
+ "modifiedAt": "2026-11-19T17:15:27.048Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=NzeBbv7Dqf",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/odcshk33u2.json modified

+++ b/reviews/openreview/8cb59z0dk9/notes/odcshk33u2.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair LJw8",
"content": {
- "metareview": "**Needs clarification during the response period**\n\nThe paper proposes two CT-specific training losses for mask-guided CT synthesis: a Semantic Intensity Distribution (SID) loss that matches per-region Hounsfield-unit distributions via a Wasserstein-1 distance, and a Structural Anatomy (SA) loss that matches smoothed gradient maps. The losses are generator-agnostic and are tested across GAN, diffusion, flow, and a 3D foundation model on SegRap and AutoPET, with image-quality metrics, a user study, and a downstream segmentation experiment.\n\nThe problem is well-motivated (perceptual realism does not guarantee correct HU distributions) and the breadth across backbones is a genuine strength. The reviews are split (one reject, one borderline reject, one borderline accept), and I do not yet see a reason to reject. The concerns below are the ones that will decide the outcome; each must be addressed to my and the reviewers' satisfaction. Concerns I have not listed need not be the focus of the response.\n\n### Major concerns\n\n1. **The \"causal\" frequency argument (Section 3.3) is unsound as stated.** All three reviewers flag it as overclaimed: there is no causal intervention or identification, so it is at most a frequency-domain interpretation. The problem runs deeper than terminology. As Reviewer 4Kg1 notes, the SID loss \"compares the marginal distributions of HU values within each anatomical mask and is invariant to spatial permutations within that mask\", so it carries no spatial-frequency information and cannot \"anchor low-frequency components.\" The sinc/convolution argument in 3.3.1 concerns the spectrum of the mask indicator, not the quantity the SID loss actually constrains, so the low-frequency-anchoring claim does not follow. Drop \"causal,\" present the spectral improvement as an empirical observation, and either prove or remove the low-frequency claim.\n\n2. **The headline downstream result (synthetic $\\ge$ real) is confounded, and the metrics are internally inconsistent (Table 2).** Training a segmenter on LDM-synthesized data outperforms training on real data, which all three reviewers flag as counterintuitive. Because the synthetic CTs are generated from the same masks that serve as the segmentation targets, this is what mask-consistency leakage would produce (the synthetic set is more label-consistent than noisy real data) rather than evidence of genuine utility. In a leakage-free comparison a synthetic-only model should not exceed real-only training on a real, disjoint test set. Separately, the reported IoU is inconsistent with the reported Dice (Reviewer mcfo): by the identity $\\mathrm{IoU}=\\mathrm{Dice}/(2-\\mathrm{Dice})$, the per-class Dice–IoU gaps for SpinalCord (Dice 0.55) and Brain (Dice 0.71) alone sum to more than the total gap the reported means permit across all 45 organ classes (mean Dice 0.910 vs mean IoU 0.906, a gap of 0.004), so the two cannot both hold under a consistent averaging convention. Please give the full protocol (what is trained on synthetic versus real, equal data sizes, whether masks are shared, whether the test set is fully real and disjoint, and leakage controls), reconcile the metrics, and reinterpret the claim.\n\n3. **The evaluation is under-specified and under-powered.** Reviewer 4Kg1 (major) notes there are no train/validation/test split counts, no statement of patient- versus slice-level splitting, and no patient-level variability or confidence intervals (Checklist #6–#7), all of which are critical here. The user study lacks reader count, expertise, blinding, randomization, and inter-rater agreement (FjxJ, 4Kg1). Evaluation is 2D slice-based on volumetric data; 3D metrics are requested and, being evaluation-only, are cheap to add (4Kg1). These are needed before the quantitative claims can be assessed.\n\n4. **Integration across generator families, and conditional diversity, are not established.** Reviewer mcfo raises two points I share. First, applying image-space HU and gradient losses inside diffusion and flow training requires a clean-image estimate at every step, which is unreliable early in diffusion, and, for latent diffusion, interacts with VAE decoding (is the VAE frozen; does the SID loss penalize VAE reconstruction error?). These details belong in the main text. Second, mask-guided synthesis is one-to-many, but the losses supervise against the single paired real CT, which may collapse conditional diversity; show multiple samples per mask and analyze whether diversity is preserved. Robustness to noisy or coarse masks (FjxJ) belongs here as well.\n\n5. **Clarity of exposition and results presentation.** All three reviewers rate clarity \"not good,\" and it materially impedes assessment. Section 3.3 is the main offender: the frequency-domain derivation moves between the mask spectrum, the Sobel response, and the two losses without making explicit which object each equation constrains, which is part of why the \"causal\" claim reads as overstated (Major 1); it should be rewritten to state plainly what is and is not shown. The empirical section is also hard to read: the central comparison is carried by dense tables (Table 1 alone spans five metrics across two datasets and roughly a dozen methods) and by prose that recites values rather than interpreting them, so the main finding — where the combined LS² loss helps, and across which backbones and metrics — is difficult to extract. A figure showing the per-method, per-metric improvement would convey this far more directly than the current tables and should be foregrounded. Relatedly, several important method details (the diffusion/flow/VAE integration of Major 4) currently appear only in the appendix and should be in the main text (mcfo).\n\n### Minor concerns\n\n- \"Spectral bias and F-Principle\" (l. 81) are invoked without references or explanation.\n- The SID loss weights every clinical window and anatomical region equally (uniform $1/W$ over windows and $1/K$ over organ masks), so a small critical structure counts the same as a large one; motivate or reconsider this weighting.\n\nConcerns I have not listed need not be the focus of the response."
+ "metareview": "**Needs clarification during the response period**\n\nThe paper proposes two CT-specific training losses for mask-guided CT synthesis: a Semantic Intensity Distribution (SID) loss that matches per-region Hounsfield-unit distributions via a Wasserstein-1 distance, and a Structural Anatomy (SA) loss that matches smoothed gradient maps. The losses are generator-agnostic and are tested across GAN, diffusion, flow, and a 3D foundation model on SegRap and AutoPET, with image-quality metrics, a user study, and a downstream segmentation experiment.\n\nThe problem is well-motivated (perceptual realism does not guarantee correct HU distributions) and the breadth across backbones is a genuine strength. The reviews are split (one reject, one borderline reject, one borderline accept), and I do not yet see a reason to reject. The concerns below are the ones that will decide the outcome; each must be addressed to my and the reviewers' satisfaction. Concerns I have not listed need not be the focus of the response.\n\n### Major concerns\n\n1. **The \"causal\" frequency argument (Section 3.3) is unsound as stated.** All three reviewers flag it as overclaimed: there is no causal intervention or identification, so it is at most a frequency-domain interpretation. The problem runs deeper than terminology. As Reviewer 4Kg1 notes, the SID loss \"compares the marginal distributions of HU values within each anatomical mask and is invariant to spatial permutations within that mask\", so it carries no spatial-frequency information and cannot \"anchor low-frequency components.\" The sinc/convolution argument in 3.3.1 concerns the spectrum of the mask indicator, not the quantity the SID loss actually constrains, so the low-frequency-anchoring claim does not follow. Drop \"causal,\" present the spectral improvement as an empirical observation, and either prove or remove the low-frequency claim.\n\n2. **The headline downstream result (synthetic $\\ge$ real) is confounded, and the metrics are internally inconsistent (Table 2).** Training a segmenter on LDM-synthesized data outperforms training on real data, which all three reviewers flag as counterintuitive. Because the synthetic CTs are generated from the same masks that serve as the segmentation targets, this is what mask-consistency leakage would produce (the synthetic set is more label-consistent than noisy real data) rather than evidence of genuine utility. In a leakage-free comparison a synthetic-only model should not exceed real-only training on a real, disjoint test set. Separately, the reported IoU is inconsistent with the reported Dice (Reviewer mcfo): by the identity $\\mathrm{IoU}=\\mathrm{Dice}/(2-\\mathrm{Dice})$, the per-class Dice–IoU gaps for SpinalCord (Dice 0.55) and Brain (Dice 0.71) alone sum to more than the total gap the reported means permit across all 45 organ classes (mean Dice 0.910 vs mean IoU 0.906, a gap of 0.004), so the two cannot both hold under a consistent averaging convention. Please give the full protocol (what is trained on synthetic versus real, equal data sizes, whether masks are shared, whether the test set is fully real and disjoint, and leakage controls), reconcile the metrics, and reinterpret the claim.\n\n3. **The evaluation is under-specified and under-powered.** Reviewer 4Kg1 (major) notes there are no train/validation/test split counts, no statement of patient- versus slice-level splitting, and no patient-level variability or confidence intervals (Checklist #6–#7), all of which are critical here. The user study lacks reader count, expertise, blinding, randomization, and inter-rater agreement (FjxJ, 4Kg1). Evaluation is 2D slice-based on volumetric data; 3D metrics are requested and, being evaluation-only, are cheap to add (4Kg1). These are needed before the quantitative claims can be assessed.\n\n4. **Integration across generator families, and conditional diversity, are not established.** Reviewer mcfo raises two points I share. First, applying image-space HU and gradient losses inside diffusion and flow training requires a clean-image estimate at every step, which is unreliable early in diffusion, and, for latent diffusion, interacts with VAE decoding (is the VAE frozen; does the SID loss penalize VAE reconstruction error?). These details belong in the main text. Second, mask-guided synthesis is one-to-many, but the losses supervise against the single paired real CT, which may collapse conditional diversity; show multiple samples per mask and analyze whether diversity is preserved. Robustness to noisy or coarse masks (FjxJ) belongs here as well.\n\n5. **Clarity of exposition and results presentation.** All three reviewers rate clarity \"not good,\" and it materially impedes assessment. Section 3.3 is the main offender: the frequency-domain derivation moves between the mask spectrum, the Sobel response, and the two losses without making explicit which object each equation constrains, which is part of why the \"causal\" claim reads as overstated (Major 1); it should be rewritten to state plainly what is and is not shown. The empirical section is also hard to read: the central comparison is carried by dense tables (Table 1 alone spans five metrics across two datasets and roughly a dozen methods) and by prose that recites values rather than interpreting them, so the main finding — where the combined LS² loss helps, and across which backbones and metrics — is difficult to extract. A figure showing the per-method, per-metric improvement would convey this far more directly than the current tables and should be foregrounded. Relatedly, several important method details (the diffusion/flow/VAE integration of Major 4) currently appear only in the appendix and should be in the main text (mcfo).\n\n### Minor concerns\n\n- \"Spectral bias and F-Principle\" (l. 81) are invoked without references or explanation.\n- The SID loss weights every clinical window and anatomical region equally (uniform $1/W$ over windows and $1/K$ over organ masks), so a small critical structure counts the same as a large one; motivate or reconsider this weighting.\n\nConcerns I have not listed need not be the focus of the response.",
+ "final_justification": "I have read the authors' rebuttal and the full reviewer discussion. The response substantively addressed the concerns in my initial meta-review, and all three reviewers raised their scores over the exchange (mcfo 2→4, FjxJ 4→5, 4Kg1 3→5), converging on a unanimous accept-leaning panel.\n\nAgainst the five major concerns:\n\n1. **Causal / frequency argument (Major 1):** the \"causal\" claim is retracted and reframed as empirical, with the SID-vs-histogram-loss spectral validation added. Resolved.\n2. **Downstream synthetic-vs-real and Dice/IoU (Major 2):** protocol specified and the \"synthetic beats real\" claim tempered to a hypothesis; my Dice/IoU objection does not hold under their macro-averaging (mcfo agreed). Resolved.\n3. **Evaluation rigor (Major 3):** splits, patient-level 3D metrics, single-reader study details (suitably tempered), and 3D / multiplanar metrics added. Resolved.\n4. **Integration and diversity (Major 4):** full LDM objective, a timestep-stability analysis, a scoped flow derivation, and an honest diversity analysis added. Resolved.\n5. **Clarity / presentation (Major 5):** the specific gaps were filled in discussion; mcfo still flags the submitted paper's presentation as the residual, contingent on the camera-ready folding in the promised additions."
},
"createdAt": "2026-07-19T06:47:39.953Z",
- "modifiedAt": "2026-11-18T15:22:17.984Z",
+ "modifiedAt": "2026-11-19T05:01:23.265Z",
"url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=odcshk33u2",
"license": "CC-BY-4.0"
}

reviews/openreview/8cb59z0dk9/notes/ow2r3iugfx.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/ow2r3iugfx.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "ow2r3IUgfx",
+ "replyTo": "7Rerkdx4jV",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer FjxJ",
+ "content": {
+ "comment": "Thank you for the comprehensive clarifications. The precise spectral definitions, matched coarse-mask baseline, paired patient-level segmentation analysis, and appropriately tempered reader-study and volumetric-consistency claims address my remaining concerns. The rebuttal substantially strengthens the empirical support."
+ },
+ "createdAt": "2026-08-03T03:48:50.318Z",
+ "modifiedAt": "2026-11-19T17:15:26.504Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=ow2r3IUgfx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/pcfspytctu.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/pcfspytctu.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "pCfsPyTCTu",
+ "replyTo": "74u0coFYx9",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to question 3",
+ "comment": "Thanks for this important question. **LPIPS and 1−SSIM reported previously were computed pairwise among ten images generated from the same mask, rather than against real CT**. \n\nWe agree that the reasons for the reduced LPIPS and 1−SSIM require further investigation. Motivated by your question, we performed an sample-level distribution analysis to provide a more detailed assessment of fidelity–diversity trade-off.\n\nFirst, we performed a stratified LPIPS analysis. As described previously, LDM and LDM+LS2 each generated ten images from every conditioning mask. For the i-th generated image, we calculated its mean LPIPS relative to the other nine images generated from the same mask. This metric quantifies the contribution of each image to the overall perceptual diversity under the same condition. The mean 1−SSIM was calculated in the same way.\n\nTo account for differences across generated anatomy and masks, we ranked the ten images by $d_i^{LPIPS}$ within each mask and method and divided them into three groups: Low (three samples with the lowest LPIPS); Middle (middle four samples); and High (three samples with the highest LPIPS). Samples from all masks were then pooled within each group for LDM and LDM+LS2.\n\nFor each generated image, we computed HU-W1 against real CT (higher means larger intensity shift) and Dice between an independent segmentation model's (trained on real AutoPET dataset, and never seen these images and masks before) output and the mask (lower means worse anatomical consistency).\n\nAs shown in Table below, For LDM, as pairwise LPIPS increased from the Low to the High group, HU-W1 increased from 197.56 to 231.14, while Dice decreased from 0.9404 to Low to the High group, HU-W1 increased from 197.56 to 0.9140. The same trend was observed for LDM+LS2, but with lower variability and better HU and anatomical consistency. Specifically, within High-LPIPS group, LDM+LS2 reduced HU-W1 from 231.14 to 223.50 and increased Dice from 0.9140 to 0.9352 compared with LDM. These suggest that **some samples contributing greater within-condition perceptual diversity also has larger HU-distribution shifts and poorer structural consistency**.\n\n\n$$\n\\\\begin{array}{ccccccc}\n\\\\hline\nMethod & Group_{LPIPS} & LPIPS & 1-SSIM & HU-W1 & Dice \\\\\\\\\n\\\\hline\nLDM & Low & 0.0292±0.0107 & 0.0906±0.0309 & 197.56±29.69 & 0.9404± 0.0248 \\\\\\\\\nLDM & Middle & 0.0508±0.0085 & 0.1330±0.0301 & 218.47±34.15 & 0.9267± 0.0250 \\\\\\\\\nLDM & High & 0.0719±0.0117 & 0.1702±0.0315 & 231.14±33.19 & 0.9140± 0.0219 \\\\\\\\\nLDM+LS2 & Low & 0.0185±0.0074 & 0.0679±0.0201 & 199.42±22.41 & 0.9482± 0.0177 \\\\\\\\\nLDM+LS2 & Middle & 0.0353±0.0067 & 0.0958±0.0205 & 207.81±22.36 & 0.9423± 0.0206 \\\\\\\\\nLDM+LS2 & High & 0.0520±0.0073 & 0.1204±0.0188 & 223.50±21.58 & 0.9352± 0.0190 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\nWe further performed a progressive sample-removal analysis based on LPIPS. To examine whether “only implausible variation was removed”, we used 1−Dice and HU-W1 as indicators of low-quality generation. Within each mask and method, the ten generated images were ranked according to either 1−Dice or HU-W1. We then sequentially removed the top 10% (one image), 20% (two images), and 30% (three images) samples with lowest quality. As shown in Table below, at each removal level, all pairwise LPIPS were recomputed among the retained images. Both methods retained the same number of samples at every removal level, avoiding potential bias caused by unequal sample sizes.\n\n$$\n\\\\begin{array}{cccccc}\n\\\\hline\nFiltering\\\\ criterion & Removed\\\\ ratio & LPIPS_{LDM}& LPIPS_{LDM+LS2} & Difference \\\\\\\\\n\\\\hline\nNone & 0\\\\% & 0.0506±0.0068 & 0.0353±0.0045 & 0.0153 \\\\\\\\\n1-Dice & 10\\\\% & 0.0474±0.0061 & 0.0349±0.0043 & 0.0125 \\\\\\\\\n1-Dice & 20\\\\% & 0.0437±0.0053 & 0.0343±0.0041 & 0.0094 \\\\\\\\\n1-Dice & 30\\\\% & 0.0406±0.0048 & 0.0338±0.0039 & 0.0068 \\\\\\\\\nHU-W1 & 10\\\\% & 0.0478±0.0062 & 0.0350±0.0044 & 0.0128 \\\\\\\\\nHU-W1 & 20\\\\% & 0.0442±0.0055 & 0.0345±0.0042 & 0.0097 \\\\\\\\\nHU-W1 & 30\\\\% & 0.0414±0.0049 & 0.0340±0.0040 & 0.0074 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\nAfter excluding low-quality samples identified by Dice or HU-W1, LPIPS of LDM decreased substantially more than that of LDM+LS2. For example, after removing the highest 30% of samples according to 1−Dice, LPIPS of LDM decreased from 0.0506 to 0.0406, whereas that of LDM+LS2 decreased only from 0.0353 to 0.0338. Consequently, LPIPS gap between them narrowed from 0.0153 to 0.0068, corresponding to a 55.6% reduction.\n\nThe above evidence indicates that **a substantial portion of the diversity reduction introduced by LS2 can be attributed to fewer low-quality samples**. However, because a residual LPIPS gap of 0.0068 remains after excluding such samples, **we cannot rule out the possibility that LS2 also suppresses some plausible stochastic variation**.\n\nWe will add these experiments and revise the manuscript accordingly. Thank you again for this insightful question, which has improved the completeness and clarity of our manuscript."
+ },
+ "createdAt": "2026-07-31T20:20:05.953Z",
+ "modifiedAt": "2026-11-19T17:15:26.733Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=pCfsPyTCTu",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/rded8gpqjw.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/rded8gpqjw.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "RDED8GPQJw",
+ "replyTo": "CxNWZOygzp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 4Kg1",
+ "content": {
+ "title": "Too broad comments for applicability",
+ "comment": "For the dependence on segmentation masks and practical applicability, the authors explained that this is an inherent limitation of conditional image generation methods (e.g., pix2pix), and that the proposed method can still be valuable for (a) adaptive radiotherapy, (b) improved generation with better HU and structural consistency, which may be useful for phantom design, digital phantoms, and radiotherapy education, and (c) robustness to imperfect segmentation. Claim (a) is probably too strong, as it may require additional experimental support. Claim (b) is plausible because masks may be intentionally available in those settings. Claim (c) is also plausible, although the current evidence is somewhat limited because the mask imperfections were simulated through test-time label dropout and downsampling rather than obtained from realistic segmentation-model errors. Adding (b) as a motivational statement somewhere in the paper could help readers better understand the practical value of the method. The other applications may be beyond the scope of this paper and could be further validated in future work."
+ },
+ "createdAt": "2026-08-03T06:06:14.090Z",
+ "modifiedAt": "2026-11-19T17:15:26.495Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=RDED8GPQJw",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/s2ywcevkg7.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/s2ywcevkg7.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "s2YWceVKG7",
+ "replyTo": "ow2r3IUgfx",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to FjxJ",
+ "comment": "We thank the reviewer for the positive feedback and constructive suggestions during the rebuttal, which have significantly strengthened our manuscript."
+ },
+ "createdAt": "2026-08-04T06:33:28.608Z",
+ "modifiedAt": "2026-11-19T17:15:26.378Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=s2YWceVKG7",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/sapqnmhjdk.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/sapqnmhjdk.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "sapqNMHjDk",
+ "replyTo": "0BO1rasBLC",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Definitions of LF/HF errors, frequency cutoff, normalization, and ± unit.",
+ "comment": "Thank you for your question. We are sorry that we did not provide them due to space limit last time. We would like to provide these definitions and also state them in revised manuscript.\n\n**For each matched real and synthesized image pair, both images were first converted to grayscale and normalized with pixel intensities in [0,1].**\n\nLet $I_{real}$ and $I_{syn}$ denote the resulting real and synthesized images, respectively. Their centered two-dimensional discrete Fourier transforms were computed as\n$$F_{real}=fftshift(FFT2(I_{real})), \\quad F_{syn}=fftshift(FFT2(I_{syn}))$$\n\nThe corresponding log-magnitude spectra were defined as $$S_{real}(u,v)=log(1+|F_{real}(u,v)|), \\quad S_{syn}(u,v)=log(1+|F_{syn}(u,v)|)$$\n \nWe then calculate the absolute log-spectral error map:\n$$E(u,v)=|S_{real}(u,v)-S_{syn}(u,v)|$$\n\nAfter applying $fftshift$, the zero-frequency component was relocated to the center of the spectrum. For each CT slice, the normalized radial coordinate was defined as $\\rho(u,v)=\\\\frac{\\sqrt{(u - c_x)^2+(v - c_y)^2}}{\\max_{u,v} \\sqrt{(u-c_x)^2+(v-c_y)^2}}$ where $(c_x,c_y)$ is center coordinate. Thus, $\\rho$ ranges from 0 at the center of the shifted spectrum to 1 at the farthest corner of the frequency grid.\n\n**The low- and high-frequency regions were defined using the relative radial-frequency thresholds $\\rho<0.25$ and $\\rho>0.50$, respectively:\n$$\\Omega_{LF}=\\\\{(u,v):\\rho(u,v)<0.25\\\\}, \\Omega_{HF}=\\\\{(u,v):\\rho(u,v)>0.50\\\\}$$**\nFrequencies satisfying $0.25 \\leq \\rho \\leq 0.50$ were treated as an intermediate-frequency band and were not included in either metric. **The LF and HF errors for each image pair were computed as the mean absolute log-spectral discrepancy within the corresponding regions:**\n\n$$e_{LF}=\\frac{1}{|\\Omega_{LF}|}\\sum_{(u,v)\\in\\Omega_{\\mathrm{LF}}}E(u,v)$$\n\n$$e_{HF}=\\frac{1}{|\\Omega_{HF}|}\\sum_{(u,v)\\in\\Omega_{\\mathrm{HF}}}E(u,v)$$\n\n**Regarding normalization, the image intensities were normalized to [0,1], while the radial frequency coordinate was normalized by the maximum radius of the discrete Fourier grid. The FFT magnitude itself was not additionally normalized; only the log(1+∣F∣) transformation was applied to compress its dynamic range.** Because all images were processed at the same fixed resolution of 256×256, the spectral scale was consistent across all compared methods. The thresholds 0.25 and 0.50 therefore represent relative radial frequencies rather than physical frequencies in Hz, cycles/pixel, or cycles/mm.\n\n**For a test set containing $N$ matched two-dimensional slice pairs, LF and HF errors were first calculated separately for each pair.** The reported results are the across-image mean and sample standard deviation:\n\n$$\\bar{e}=\\frac{1}{N}\\sum_{i=1}^{N} e_i, \\quad s=\\sqrt{\\frac{1}{N-1}\\sum_{i=1}^{N} (e_i-\\bar{e})^2}$$\n\n**Accordingly, the symbol “±” denotes the sample standard deviation across matched two-dimensional slice pairs, rather than the standard error, variance, confidence interval, or patient-level variability. The standard deviation therefore has the same scale as the corresponding LF/HF error. And both the LF/HF means and their standard deviations are reported in dimensionless log-spectral-error units.**"
+ },
+ "createdAt": "2026-08-01T14:22:10.787Z",
+ "modifiedAt": "2026-11-19T17:15:26.858Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=sapqNMHjDk",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/sy4nqbtnp3.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/sy4nqbtnp3.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "sY4nQbtNP3",
+ "replyTo": "NzeBbv7Dqf",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Minor concerns in meta review: references and SID weighting",
+ "comment": "Thank you for the suggestion. We will add attached references for spectral bias and the F-Principle and clarify the uniform weighting used in SID from the perspective of HU window and organ-mask.\n\nFor HU-window weighting, SID applies multiple overlapping windows that collectively cover the full HU range, enabling separate constraints on different tissue-intensity intervals. The same window definitions and uniform weights were used across all experiments without dataset-specific tuning. For normal anatomical CT, this fixed setting covers the major tissue types and yielded consistent improvements (Table 1 in original paper). For disease-specific tasks, such as pulmonary lesions, the weights of relevant intensity intervals could be increased, but this extension requires dedicated validation. \n\nFor organ-mask weighting, SID averages the loss across all valid organs rather than weighting by organ volume. This prevents large organs, such as the liver or lungs, from dominating the objective and suppressing signals from small structures, such as the optic nerves or cochleae. Equal organ weighting therefore preserves the contribution of small anatomical structures. We acknowledge that the optimal weighting may vary with dataset quality and anatomy. Task-adaptive window weighting and organ-specific reweighting are promising extensions for future work.\n\n*Rahaman N, Baratin A, Arpit D, et al. On the spectral bias of neural networks[C]//International conference on machine learning. PMLR, 2019: 5301-5310.*\n\n*Zhi-Qin J, Xu J, Tao L, et al. Frequency principle: Fourier analysis sheds light on deep neural networks[J]. Communications in Computational Physics, 2020, 28(5): 1746-1767.*"
+ },
+ "createdAt": "2026-07-29T01:49:11.219Z",
+ "modifiedAt": "2026-11-19T17:15:26.855Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=sY4nQbtNP3",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/tsxcghanq4.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/tsxcghanq4.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "TSXcGHANq4",
+ "replyTo": "jjxs9kjWHO",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to question 2's clean-image estimate: part2(table1-2)",
+ "comment": "**Table 1. Loss values and gradient norms across training-step windows in the low-noise timestep interval [1, 334).** G denotes the global L2 norm of the parameter gradients corresponding to each loss.\n$$\n\\\\begin{array}{ccccccc}\n\\\\hline\nSteps & Denoising\\\\ loss & LS2 & Total\\\\ loss & G_{Denoising} & G_{LS2} & G_{Total} \\\\\\\\\n\\\\hline\n0-10k & 0.213773 ± 0.055293 & 0.019285 ± 0.008455 & 0.233058 ± 0.059747 & 2.727431 ± 0.684234 & 1.548071 ± 0.695348 & 3.311045 ± 0.763004 \\\\\\\\\n10-20k & 0.148294 ± 0.038357 & 0.014128 ± 0.006194 & 0.162422 ± 0.041637 & 2.788976 ± 0.721868 & 1.592260 ± 0.700394 & 3.390968 ± 0.716182 \\\\\\\\\n20-30k & 0.128913 ± 0.032861 & 0.011948 ± 0.005528 & 0.140861 ± 0.035945 & 2.796375 ± 0.736637 & 1.544741 ± 0.716191 & 3.359624 ± 0.789342 \\\\\\\\\n30-40k & 0.121789 ± 0.031501 & 0.011024 ± 0.004833 & 0.132812 ± 0.034048 & 2.721046 ± 0.691418 & 1.539225 ± 0.724963 & 3.306395 ± 0.741777 \\\\\\\\\n40-50k & 0.112936 ± 0.028827 & 0.010587 ± 0.004142 & 0.123523 ± 0.030774 & 2.753180 ± 0.695970 & 1.625379 ± 0.698328 & 3.387314 ± 0.761319 \\\\\\\\\n50-60k & 0.100211 ± 0.025920 & 0.009308 ± 0.004081 & 0.109519 ± 0.028076 & 2.798937 ± 0.767235 & 1.584278 ± 0.694415 & 3.335766 ± 0.780484 \\\\\\\\\n60-70k & 0.096570 ± 0.020382 & 0.008705 ± 0.003987 & 0.105275 ± 0.023366 & 2.733927 ± 0.775726 & 1.624033 ± 0.693541 & 3.350250 ± 0.782077 \\\\\\\\\n70-80k & 0.095302 ± 0.024609 & 0.008559 ± 0.003746 & 0.103861 ± 0.026582 & 2.731337 ± 0.716487 & 1.577624 ± 0.699129 & 3.330316 ± 0.760834 \\\\\\\\\n80-90k & 0.095040 ± 0.024376 & 0.008373 ± 0.003654 & 0.103413 ± 0.026277 & 2.784309 ± 0.724602 & 1.555064 ± 0.643758 & 3.327478 ± 0.719462 \\\\\\\\\n90-100k & 0.093753 ± 0.024626 & 0.007949 ± 0.003546 & 0.101702 ± 0.026679 & 2.835750 ± 0.743379 & 1.506151 ± 0.628251 & 3.303459 ± 0.734727 \\\\\\\\\n100-110k & 0.092853 ± 0.023873 & 0.007267 ± 0.003319 & 0.100120 ± 0.025705 & 2.898574 ± 0.722353 & 1.332863 ± 0.652947 & 3.198340 ± 0.709028 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\n**Table 2. Loss values and gradient norms across training-step windows in the medium-noise timestep interval [334, 667).** G denotes the global L2 norm of the parameter gradients corresponding to each loss.\n$$\n\\\\begin{array}{ccccccc}\n\\\\hline\nSteps & Denoising\\\\ loss & LS2 & Total\\\\ loss & G_{Denoising} & G_{LS2} & G_{Total} \\\\\\\\\n\\\\hline\n0-10k & 0.072115 ± 0.017258 & 0.024284 ± 0.010264 & 0.096399 ± 0.023407 & 2.451251 ± 0.612708 & 5.141414 ± 2.273347 & 5.784265 ± 2.040145 \\\\\\\\\n10-20k & 0.050026 ± 0.011972 & 0.017790 ± 0.007519 & 0.067817 ± 0.016535 & 2.435609 ± 0.668940 & 4.940675 ± 2.105328 & 5.654657 ± 1.811309 \\\\\\\\\n20-30k & 0.041085 ± 0.009832 & 0.013881 ± 0.005867 & 0.054966 ± 0.013350 & 2.495017 ± 0.673218 & 4.889688 ± 2.190225 & 5.581027 ± 1.877162 \\\\\\\\\n30-40k & 0.038478 ± 0.009674 & 0.013553 ± 0.005876 & 0.052031 ± 0.013170 & 2.421976 ± 0.636292 & 5.051234 ± 2.067402 & 5.708888 ± 1.823715 \\\\\\\\\n40-50k & 0.036714 ± 0.008635 & 0.012965 ± 0.005178 & 0.049679 ± 0.011387 & 2.414981 ± 0.642042 & 5.040545 ± 2.217532 & 5.738969 ± 1.968396 \\\\\\\\\n50-60k & 0.034172 ± 0.006530 & 0.011721 ± 0.004954 & 0.045893 ± 0.009675 & 2.598294 ± 0.673867 & 5.269504 ± 2.365863 & 5.989208 ± 2.085040 \\\\\\\\\n60-70k & 0.033253 ± 0.007988 & 0.010933 ± 0.004676 & 0.044186 ± 0.009779 & 2.711837 ± 0.699284 & 5.833401 ± 2.753262 & 6.587484 ± 2.448630 \\\\\\\\\n70-80k & 0.032150 ± 0.007681 & 0.010777 ± 0.004548 & 0.042927 ± 0.010403 & 2.431627 ± 0.634322 & 5.012577 ± 2.199707 & 5.691148 ± 1.924614 \\\\\\\\\n80-90k & 0.031887 ± 0.007628 & 0.010505 ± 0.004352 & 0.042392 ± 0.010142 & 2.488228 ± 0.638669 & 5.063227 ± 2.199924 & 5.687587 ± 1.931434 \\\\\\\\\n90-100k & 0.031410 ± 0.007573 & 0.009771 ± 0.004054 & 0.041180 ± 0.009963 & 2.626566 ± 0.642986 & 4.769115 ± 2.040559 & 5.347592 ± 1.725725 \\\\\\\\\n100-110k & 0.030661 ± 0.007444 & 0.008737 ± 0.003650 & 0.039398 ± 0.009479 & 2.726533 ± 0.623777 & 4.315645 ± 1.962322 & 4.831811 ± 1.530442\\\\\\\\\n\\\\hline\n\\\\end{array}\n$$"
+ },
+ "createdAt": "2026-07-31T20:16:22.118Z",
+ "modifiedAt": "2026-11-19T17:15:26.804Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=TSXcGHANq4",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/tyto31scet.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/tyto31scet.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "TYTO31scET",
+ "replyTo": "VzaJY3R5XF",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to question 1",
+ "comment": "Thank you for this helpful suggestion, which improves the clarity of the manuscript. The clarification will be added to the revised manuscript. The complete training objective of LDM and clarification about how $LS^2$ is weighted relative to the standard denoising loss are as follows. \n\nSpecifically, given a real CT image $f$ and its mask $M$, we first encode the image into the latent space as $z_0=E(f)$ where $E$ is the encoder of the frozen VAE. \n\nThe forward diffusion process is defined as $ z_t = \\sqrt{\\bar{\\alpha}_t}z_0 + \\sqrt{1-\\bar{\\alpha}_t}\\ \\epsilon, \\epsilon\\sim\\mathcal N(0,I)$, where $t$ is the sampled diffusion timestep and $\\bar{\\alpha_t}$ is determined by the cumulative noise schedule.\n\nGiven the noise prediction $\\epsilon\\_{\\theta}(z\\_t,t,M)$ produced by the denoising network, the clean-image estimate is $$\\hat{f}_t=D(\\frac{z_t- \\sqrt{1-\\bar{\\alpha}_t} \\epsilon\\_{\\theta}(z\\_t,t,M)}{\\sqrt{\\bar{\\alpha}_t}})$$ Here, $D$ is the decoder of the frozen VAE.\n\nFollowing Equation (1)-(5) in manuscript, $LS^2$ is calculated directly between the real CT image $f$ and the decoded clean-image estimate: $$ \\mathcal{L\\_{LS^2}^{(t)}} = \\mathcal{L\\_{Sid}}(\\hat{f}_t,{f},M) + \\mathcal{L\\_{Sa}}(\\hat{f}_t,{f})$$. \n\nAfter Integrating $LS^2$ into denoising loss of LDM, **the complete training objective of LDM could be defined as:**\n$$\\mathcal{L\\_{LDM+LS^{2}}}=\\mathbb{E}\\_{f,M,t,\\epsilon}\\Bigg[\\ || \\epsilon-\\epsilon\\_\\theta(z_t,t,M)||_2^2 + {\\lambda}\\mathcal{L\\_{LS^2}^{(t)}} \\Bigg]$$\nwhere $\\lambda=1$.\n\nThus, **the complete $LS^2$ term is added to the original denoising objective with an external weighting coefficient of 1**."
+ },
+ "createdAt": "2026-07-31T19:48:42.118Z",
+ "modifiedAt": "2026-11-19T17:15:26.849Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=TYTO31scET",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/uvadt5jlbp.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/uvadt5jlbp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "uvaDT5JlBP",
+ "replyTo": "TSXcGHANq4",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to question 2's clean-image estimate: part3(table3-4)",
+ "comment": "**Table 3. Loss values and gradient norms across training-step windows in the high-noise timestep interval [667, 1000].** G denotes the global L2 norm of the parameter gradients corresponding to each loss.\n$$\n\\\\begin{array}{ccccccc}\n\\\\hline\nSteps & Denoising\\\\ loss & LS2 & Total\\\\ loss & G_{Denoising} & G_{LS2} & G_{Total} \\\\\\\\\n\\\\hline\n0-10k & 0.026030 ± 0.003173 & 0.062312 ± 0.020588 & 0.088342 ± 0.022105 & 2.543664 ± 0.375357 & 27.364968 ± 10.078077 & 28.339911 ± 10.058783 \\\\\\\\\n10-20k & 0.018057 ± 0.002201 & 0.045649 ± 0.015083 & 0.063706 ± 0.016129 & 2.120450 ± 0.389531 & 26.779839 ± 10.053743 & 27.745525 ± 10.024932 \\\\\\\\\n20-30k & 0.014830 ± 0.001808 & 0.035619 ± 0.011769 & 0.050448 ± 0.012633 & 2.112304 ± 0.448713 & 26.337443 ± 11.308349 & 27.322301 ± 11.210751 \\\\\\\\\n30-40k & 0.013225 ± 0.001247 & 0.032903 ± 0.008558 & 0.046128 ± 0.009151 & 2.112146 ± 0.434777 & 27.299614 ± 9.939304 & 28.293189 ± 9.912344 \\\\\\\\\n40-50k & 0.012763 ± 0.001388 & 0.031844 ± 0.009765 & 0.044607 ± 0.010423 & 2.161127 ± 0.471437 & 26.589164 ± 10.054380 & 27.561768 ± 9.969275 \\\\\\\\\n50-60k & 0.012202 ± 0.001488 & 0.030076 ± 0.009937 & 0.042278 ± 0.010646 & 2.140359 ± 0.386499 & 27.104187 ± 10.081078 & 28.082674 ± 10.002529 \\\\\\\\\n60-70k & 0.011938 ± 0.001236 & 0.028614 ± 0.008955 & 0.040552 ± 0.009539 & 2.141863 ± 0.417288 & 27.244926 ± 10.044197 & 28.209489 ± 9.981342 \\\\\\\\\n70-80k & 0.011604 ± 0.001412 & 0.027655 ± 0.009122 & 0.039259 ± 0.009797 & 2.129068 ± 0.401809 & 26.214296 ± 10.044197 & 27.209489 ± 9.981342 \\\\\\\\\n80-90k & 0.011050 ± 0.001354 & 0.026117 ± 0.008546 & 0.037168 ± 0.009143 & 2.110272 ± 0.379214 & 26.684278 ± 9.562189 & 27.610744 ± 9.512787 \\\\\\\\\n90-100k & 0.010302 ± 0.001309 & 0.023850 ± 0.007788 & 0.034152 ± 0.008192 & 2.096523 ± 0.448785 & 26.016927 ± 9.435703 & 26.929185 ± 9.208213 \\\\\\\\\n100-110k & 0.009135 ± 0.001271 & 0.021928 ± 0.007276 & 0.031063 ± 0.007792 & 2.001255 ± 0.392084 & 25.701558 ± 8.732153 & 26.624069 ± 8.664367\\\\\\\\\n\\\\hline\n\\\\end{array}\n$$\n\n**Table 4. Comparison of the original denoising losses of LDM and LDM+LS2 during training.** \n$$\n\\\\begin{array}{ccc}\n\\\\hline\nSteps & LDM & LDM+LS^2 \\\\\\\\\n\\\\hline\n0-10k & 0.122987 ± 0.079875 & 0.103973 ± 0.056784 \\\\\\\\\n10-20k & 0.084006 ± 0.019161 & 0.072126 ± 0.016540 \\\\\\\\\n20-30k & 0.075050 ± 0.020212 & 0.059234 ± 0.022389 \\\\\\\\\n30-40k & 0.063137 ± 0.014880 & 0.048740 ± 0.012161 \\\\\\\\\n40-50k & 0.056027 ± 0.014293 & 0.040844 ± 0.009856 \\\\\\\\\n50-60k & 0.052973 ± 0.014378 & 0.036178 ± 0.008136 \\\\\\\\\n60-70k & 0.046578 ± 0.013076 & 0.033119 ± 0.009302 \\\\\\\\\n70-80k & 0.042812 ± 0.012010 & 0.030262 ± 0.007342 \\\\\\\\\n80-90k & 0.039009 ± 0.010773 & 0.028913 ± 0.008263 \\\\\\\\\n90-100k & 0.037768 ± 0.012086 & 0.028884 ± 0.009525 \\\\\\\\\n100-110k & 0.034905 ± 0.011420 & 0.025865 ± 0.007910\\\\\\\\\n\\\\hline\n\\\\end{array}\n$$"
+ },
+ "createdAt": "2026-07-31T20:17:15.447Z",
+ "modifiedAt": "2026-11-19T17:15:26.794Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=uvaDT5JlBP",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/vzajy3r5xf.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/vzajy3r5xf.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "VzaJY3R5XF",
+ "replyTo": "VcYeTKW7SZ",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer mcfo",
+ "content": {
+ "title": "Response to rebuttal",
+ "comment": "Thank you for the clarification. I now understand the high-level implementation of LS2 in latent diffusion models. However, I still have several questions.\n\n1. Please provide the complete training objective and explain how LS2 is weighted relative to the standard denoising loss. The paper defines the components within LS2, but not how the full loss is balanced against the original diffusion objective.\n\n2. My concern remains that the clean-image estimate may be unreliable at high-noise timesteps. The rebuttal states that no timestep weighting is used, but does not analyse whether the resulting loss values and gradients remain stable across timesteps. Also, I do not think my concern regarding flow models is fully addressed. Equation 12 provides a clean-image estimate for a linear-path. The rebuttal states that LS2 can be applied more generally whenever a differentiable clean-image estimate is available, but this requirement and the supported class of flow parameterizations should be stated explicitly in the paper. This scope limitation is not my main concern, but the claim should be made more precise.\n\n3. Please clarify how LPIPS were computed. Were they calculated pairwise among the ten samples generated from the same mask, or against real images? If they are pairwise metrics, the lower LPIPS and lower 1 - SSIM indicate reduced perceptual and structural diversity. The statement that only implausible variation has been removed is only stated but not supported. I understand image attachments are not allowed, please provide other analysis such as histogram distributions etc. \n\n3. Thank you for explaining the averaging scheme. I understand the usual Dice–IoU relationship does not necessarily hold after averaging. I only wanted to point oout that a break of this relation suggests a highly skewed distribution. **I will not treat this as a main concern for now. **\n\nOverall, I still find the presentation in both the paper and the rebuttal problematic. Several implementation and evaluation details are needed to help the reader understand and reproduce the method, while they are missing or only partially explained. This substantially harms the paper’s clarity and weakens its claims of broad compatibility and robustness. I will be very happy to raise my score if I get clarification on these points."
+ },
+ "createdAt": "2026-07-30T20:08:56.728Z",
+ "modifiedAt": "2026-11-19T17:15:26.850Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=VzaJY3R5XF",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/8cb59z0dk9/notes/xg7k4ncsjt.json added

+++ b/reviews/openreview/8cb59z0dk9/notes/xg7k4ncsjt.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Xg7k4ncsjt",
+ "replyTo": "5WR1vNkRMz",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to Major concern3 in meta review: experiment settings and reporting of variability in 2/3D results",
+ "comment": "We will **specify data splits and setting of all experiments including reader study and add mean±std results based on 2D and 3D**.\n\nAll experiments used a **patient-wise data split with disjoint patient cohorts** across training, validation, and test sets. **AutoPET included 370/108/55 patients** (69.5%/20.3%/10.3%), while **SegRap included 90/20/10** patients (75.0%/16.7%/8.3%). The same patient-level splits were used for all generative models and downstream segmentation experiments.\n\nAs for **reader study details**, an associate consultant radiologist (13 years of experience) independently evaluated 100 randomly selected masks, each paired with real CT and synthetic CT (100 real pairs+100 synthetic pairs). All samples were mixed and presented in a randomized order. Each image-mask pair was stored separately, and all information indicating image origin was removed to ensure blinded evaluation. In evaluation, each pair was scored 0–2 for image realism and boundary consistency. Results are reported as counts and proportions of scores 0/1/2 per group. Since only one radiologist participated, inter-rater agreement was not assessed. We will acknowledge this as a limitation.\n\nAdditionally, we **add mean±std results based on 2D** and **additionally provide patient-level 3D metrics, including 3D SSIM and 3D PSNR, to quantify inter-patient variability**. FID, LFD, and HU-W1 remain evaluated at the slice level, as these metrics are inherently defined on 2D images or 2D image distributions. Due to space limitations, we only report **the revised slice-level and 3D results for SegRap** as follows in this turn.\n\n$$\n\\\\begin{array}{cccccccc}\n\\\\hline\nMethod & PSNR &{SSIM} & FID & LFD & HU-W1 & \\\\text{3D PSNR} & \\\\text{3D SSIM} \\\\\\\\\n\\\\hline\npix2pixHD & 24.869±2.899 & 0.811±0.078 & 37.623±0.744 & 18.139±0.668 & 120.127±11.007 & 24.078±0.932 & 0.829±0.030 \\\\\\\\\nFFL & 24.188±2.915 & 0.791±0.137 & 40.767±0.824 & 18.060±0.671 & 114.115±20.443 & 23.329±0.997 & 0.813±0.031 \\\\\\\\\nOASIS & 21.072±4.136 & 0.753±0.116 & 53.629±0.876 & 17.683±0.952 & 181.954±61.509 & 19.624±0.599 & 0.779±0.037 \\\\\\\\\nLDM & 28.809±4.320 & 0.721±0.180 & 75.542±1.348 & 15.511±0.995 & 36.226±58.802 & 26.047±2.068 & 0.738±0.055 \\\\\\\\\nimg2img-turbo & 20.260±4.367 & 0.728±0.120 & 80.789±1.249 & 17.781±0.996 & 198.448±66.885 & 18.593±0.444 & 0.741±0.037 \\\\\\\\\nSegGuideDiff & 21.685±2.150 & 0.284±0.089 & 60.322±1.576 & 18.623±0.495 & 293.397±73.184 & 19.503±0.198 & 0.411±0.029 \\\\\\\\\nFDL & 23.521±3.065 & 0.773±0.140 & 60.611±1.045 & 18.065±0.706 & 111.250±19.877 & 22.575±0.993 & 0.797±0.034 \\\\\\\\\nMOTFM & 23.820±2.912 & 0.619±0.159 & 37.492±0.827 & 23.820±0.670 & 32.402±26.073 & 22.692±0.922 & 0.654±0.027 \\\\\\\\\nMAISI-v2 & 15.697±0.803 & 0.248±0.076 & 63.890±1.767 & 28.461±0.185 & 15.740±2.920 & 16.623±0.803 & 0.301±0.076 \\\\\\\\\npix2pixHD+SID & 25.017±3.716 & 0.815±0.151 & 35.553±0.840 & 16.413±0.856 & 110.231±87.320 & 24.568±1.052 & 0.834±0.024 \\\\\\\\\npix2pixHD+SA & 24.982±2.885 & 0.814±0.136 & 33.186±0.793 & 16.475±0.664 & 115.286±23.744 & 24.187±0.925 & 0.836±0.035 \\\\\\\\\npix2pixHD+LS2 & 25.068±2.880 & 0.816±0.135 & 33.932±0.899 & 16.411±0.663 & 107.981±20.964 & 24.678±0.932 & 0.840±0.030 \\\\\\\\\nMOTFM+LS2 & 24.214±2.626 & 0.678±0.145 & 32.535±0.757 & 16.630±0.605 & 32.036±25.310 & 23.692±0.922 & 0.714±0.027 \\\\\\\\\nLDM+LS2 & 32.175±4.863 & 0.834±0.159 & 51.496±0.931 & 14.732±1.120 & 16.204±17.022 & 30.659±3.515 & 0.875±0.062 \\\\\\\\\nMAISI-v2+LS2 & 15.998±0.803 & 0.269±0.076 & 56.213±1.059 & 27.461±0.185 & 13.737±2.922 & 16.999±0.811 & 0.322±0.072 \\\\\\\\\n\\\\hline\n\\\\end{array}\n$$"
+ },
+ "createdAt": "2026-07-29T01:29:15.256Z",
+ "modifiedAt": "2026-11-19T17:15:26.944Z",
+ "url": "https://openreview.net/forum?id=8cb59z0dK9&noteId=Xg7k4ncsjt",
+ "license": "CC-BY-4.0"
+}