Update NeurIPS 2026 submission 6Ku1AhEjKl: 10 notes
@openreview[bot] · 2026-11-24 15:46 UTC · 15c8d25e8969 ·
reviews/openreview/6ku1ahejkl/notes/0hmlqfoi8m.json added
+++ b/reviews/openreview/6ku1ahejkl/notes/0hmlqfoi8m.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "0HMLQFoi8M",+ "replyTo": "HbyOhsrtn1",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "We Welcome Your Feedback on Our Responses",+ "comment": "Dear Reviewer NdY6,\n\nAs the discussion period is nearing its end, we wanted to check whether any aspects of our response remain unclear or whether you have any further questions. We would be happy to provide additional clarification. Thank you again for your time and thoughtful feedback.\n\nThanks,\nThe Authors"+ },+ "createdAt": "2026-08-03T18:16:24.260Z",+ "modifiedAt": "2026-11-19T17:16:48.099Z",+ "url": "https://openreview.net/forum?id=6Ku1AhEjKl¬eId=0HMLQFoi8M",+ "license": "CC-BY-4.0"+}
reviews/openreview/6ku1ahejkl/notes/7njy0dvuqx.json added
+++ b/reviews/openreview/6ku1ahejkl/notes/7njy0dvuqx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "7Njy0dVuQX",+ "replyTo": "xiWDHaSGxz",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank Reviewer 2Efi for the follow up and for reconsidering our submission. \n\n**(3) Protocol for external baselines.** We apologize for omitting the protocol. And we provide the details below.\n\n**Setup:** Both baselines are evaluated with frozen backbones, following CARE-PD’s convention for pretrained encoders (its classifier_only mode freezes the backbone). The 20 HC subjects define the reference set and are not used to adapt either model.\n\n**Shared protocol:** Each recording is divided into 16-frame windows sampled at 30 fps. For each window, we extract a latent representation using the corresponding frozen encoder and compute its anomaly score using the geodesic procedure described in Sec 3.5. A subject-level score is obtained by taking the median across all windows from that subject. AUROC is computed on the 8 held-out HC against the 30 PD subjects (HC/PD) and against the 30 PD plus 39 other-disease subjects (HC/all).\n\n**VPoser:** We use the V02_05 checkpoint pretrained on AMASS. Because it is a per-frame pose with no temporal axis, each frame is encoded independently, and the window defines only the interval over which we average. For each frame we encode the 21 SMPL body-pose joints and take the 32-dimensional posterior mean. The window latent representation is the average over the 16 frames.\n\n**GaitForeMer:** We use the released checkpoint pre-trained on NTU RGB+D. We feed CARE-PD’s 3D Human3.6M joints, reindexed to the checkpoint’s joint ordering. The window latent representation is the temporally pooled encoder output.\n\n**(4) Healthy Control.** Sorry for the typo and thank you for pointing it out. It should be “Healthy Control”\n\n**(10) Moment Arms.** Thank you for the correction. Our previous response conflated pose-derived muscle geometry with the estimation of muscle activations. Given a scaled musculoskeletal model, moment arms can be computed from pose without EMG and can define a complementary muscle-induced geometry. This is a very interesting point. We will note the absence of this analysis as a limitation in the manuscript and would like to explore this direction further in future work."+ },+ "createdAt": "2026-07-31T14:55:53.058Z",+ "modifiedAt": "2026-11-19T17:16:48.067Z",+ "url": "https://openreview.net/forum?id=6Ku1AhEjKl¬eId=7Njy0dVuQX",+ "license": "CC-BY-4.0"+}
reviews/openreview/6ku1ahejkl/notes/cl5gzsmg5n.json added
+++ b/reviews/openreview/6ku1ahejkl/notes/cl5gzsmg5n.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "cl5gzsmG5n",+ "replyTo": "vyoDqOs3wr",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the follow-up and for willingness to reconsider this submission.\n\nWe first summarize the corresponding experiments in one table below and then address each question using the relevant comparison. \n\nAcross the rows, we vary the graph construction and the use of the shortest path. The first row reports the original protocol. The second row reports the inductive evaluation suggested by the reviewer, in which the graph contains only the 2,193 training HC windows and the windows from the current test subject, with k=20. The final row isolates the contribution of shortest path by removing that step and scoring each test window by its direct distance to the nearest training HC window. \n\nAcross the columns, we compare two forms of the metric: the constant $G=\\hat J^\\top\\bar M\\hat J$ described in our previous response and the pointwise pullback $g(z)=J(z)^\\top M(\\hat q(z))J(z)$ described in Section 3.5. \n\n**Table: Subject-level HC/PD HC/all AUROC at K=20, condition F (95% CI)**\n| Graph | HC/PD, constant G | HC/PD, pointwise g(z) | HC/all, constant G | HC/all, pointwise g(z) |\n|---|---|---|---|---|\n| Single graph over all windows | 0.8958 [0.7833, 0.9792] | 0.9125 [0.8083, 0.9833] | 0.8678 [0.7609, 0.9475]| 0.8804 [0.7772, 0.9565] |\n| Training-HC graph + one test subject | 0.8917 [0.7667, 0.9875] | 0.9083 [0.8042, 0.9833] | 0.8551 [0.7482, 0.9565] | 0.8768 [0.7736, 0.9529] |\n| Without shortest path | 0.8875 [0.7625, 0.9875] | 0.9042 [0.8000, 0.9833] | 0.8533 [0.7464, 0.9547] | 0.8750 [0.7717, 0.9511] |\n\n**1. Which windows are in the graph**\n\nThe original graph contained all windows: the 2193 training-HC windows together with the 6886 windows of the held-out HC, PD and other-disease subjects, in one k-NN graph, with sources restricted to the training-HC windows. A test subject’s shortest path could therefore route through another test subject. \n\nThe second row is the inductive test suggested by the reviewer. The subject is removed before the next one is evaluated, so nothing is shared across test subjects. 269 of the 6886 test windows had no training-HC window among their 20 neighbors. We therefore added an edge from each to its nearest training-HC window so that every test window has a path to a source. \n\nComparing the first two rows, removing the other test subjects results in only small decreases across both metrics and both tasks. The largest decrease is 0.0127 for HC/all under the constant G. \n\n**2.1 Explain the difference between the metrics.**\n\nWe apologize for the inconsistency. Sec 3.5 and the Figure 1 caption describe $g(z)=J(z)^\\top M(\\hat q(z))J(z)$, with J(z) the decoder Jacobian and M evaluated at the decoder output. In the previous response, J was fitted once by ridge regression on the training-HC windows and M was replaced by its mean over those windows, which collapses g to a single constant matrix. This implementation difference affects only the scoring stage; it does not affect model training or the learned embeddings. During training, L_rec uses M(q_t) at every frame, as Eq. 4 states. \n\nTo quantify its empirical effect, we have now evaluated the pointwise metric in the main setting, and the table reports both forms. Across three rows and both tasks, the pointwise metric consistently yields slightly higher AUROC. The largest improvement is 0.0217 in HC/all under the inductive graph. The computational costs of the two metrics differ more substantially. Computing the pointwise metric requires the decoder Jacobian at every node, using one forward mode pass per latent dimension, whereas the fitted map requires only a single ridge regression that is reused across all nodes. On the same NVIDIA RTX 3090, constructing the metric over all 9079 nodes takes 1991s for the pointwise metric against 0.49s for the constant G. \n\nWe thank the reviewer for pointing out this inconsistency. We will review and revise all related descriptions throughout the paper, including Section 3.5 and the Figure 1 caption, to clearly distinguish the pointwise metric defined in the method from the constant scoring implementation used in our original experiments. We will identify the constant form as a computational approximation, report both its empirical effect and computational savings, and revise any statements that incorrectly imply that the original results were obtained using the pointwise metric.\n\n**2.2 Separate the effect of the metric and the graph**\n\nTo separate the effects of the metric and the shortest path, we add the third row, in which the shortest path step is removed. Removing the shortest path (from row 2 to row 3) changes the AUROC by 0.0042 at most, so the score is effectively the metric distance to the nearest training-HC window and the search over the graph adds little. \nChanging which form of the metric is used (constant to pointwise), along each row, increases AUROC by up to 0.0217. \n\n**2.3. Number of splits:**\nTen random subject splits.\n\nPlease let us know if anything is unclear."+ },+ "createdAt": "2026-08-02T23:22:23.133Z",+ "modifiedAt": "2026-11-19T17:16:47.936Z",+ "url": "https://openreview.net/forum?id=6Ku1AhEjKl¬eId=cl5gzsmG5n",+ "license": "CC-BY-4.0"+}
reviews/openreview/6ku1ahejkl/notes/frhwlijvfm.json modified
+++ b/reviews/openreview/6ku1ahejkl/notes/frhwlijvfm.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 59QV","content": {- "metareview": "In this paper, the authors propose REINS, a physics-consistent motion representation framework for clinical gait phenotyping. Rather than learning the geometry of the latent space purely from data, the method derives a Riemannian metric from the generalized inertia matrix of an articulated human body and uses this geometry to construct motion representations for Parkinson's disease gait analysis. I find the central idea technically interesting and well motivated, particularly the decision to incorporate biomechanics directly into the representation space instead of treating physics as a post-hoc regularization.\n\nThe reviews are mixed, but there is broad agreement that the paper presents an interesting and well-motivated idea. Reviewer 2Efi describes the formulation as principled and elegant, particularly the use of the inertia matrix to define a physics-consistent geometry for motion representation learning. Reviewer 6qUG similarly finds the motivation clear and appreciates the connection between inertia-induced Riemannian geometry and motion representation learning. In general, the empirical results receive positive assessments from the reviewers, especially in the low-data and cross-cohort settings, where the proposed inductive bias is well aligned with the intended clinical application.\n\nNevertheless, my main concerns lie in the evaluation protocol. Both Reviewers NdY6 and 2Efi question whether the current experiments adequately isolate the source of the reported improvements. Reviewer 2Efi specifically recommends a 3×2 ablation that separates the effects of the learned representation, the pullback metric, and the inertia-induced geodesic. Reviewer NdY6 raises the closely related concern that the current experiments do not isolate the contribution of the proposed loss from that of the scoring distance. I agree that this is the key issue for the rebuttal because it is currently unclear which component accounts for the reported improvements. Beyond this, the remaining concerns are relatively minor and mostly relate to presentation and completeness, including the unresolved ``\"Section ??\"`` cross-reference noted by both Reviewers 6qUG and 2Efi and insufficient detail on the geodesic scoring procedure.\n\nThe main priority for the rebuttal is to provide stronger empirical evidence that isolates the source of the reported performance gains. In particular, the authors should clarify the respective contributions of the learned representation, the pullback metric, and the inertia-induced geodesic scoring procedure. If the authors can address this point and the remaining clarification issues, I believe many of the current concerns would be resolved."+ "metareview": "In this paper, the authors propose REINS, a physics-consistent motion representation framework for clinical gait phenotyping. Rather than learning the geometry of the latent space purely from data, the method derives a Riemannian metric from the generalized inertia matrix of an articulated human body and uses this geometry to construct motion representations for Parkinson's disease gait analysis. I find the central idea technically interesting and well motivated, particularly the decision to incorporate biomechanics directly into the representation space instead of treating physics as a post-hoc regularization.\n\nThe reviews are mixed, but there is broad agreement that the paper presents an interesting and well-motivated idea. Reviewer 2Efi describes the formulation as principled and elegant, particularly the use of the inertia matrix to define a physics-consistent geometry for motion representation learning. Reviewer 6qUG similarly finds the motivation clear and appreciates the connection between inertia-induced Riemannian geometry and motion representation learning. In general, the empirical results receive positive assessments from the reviewers, especially in the low-data and cross-cohort settings, where the proposed inductive bias is well aligned with the intended clinical application.\n\nNevertheless, my main concerns lie in the evaluation protocol. Both Reviewers NdY6 and 2Efi question whether the current experiments adequately isolate the source of the reported improvements. Reviewer 2Efi specifically recommends a 3×2 ablation that separates the effects of the learned representation, the pullback metric, and the inertia-induced geodesic. Reviewer NdY6 raises the closely related concern that the current experiments do not isolate the contribution of the proposed loss from that of the scoring distance. I agree that this is the key issue for the rebuttal because it is currently unclear which component accounts for the reported improvements. Beyond this, the remaining concerns are relatively minor and mostly relate to presentation and completeness, including the unresolved ``\"Section ??\"`` cross-reference noted by both Reviewers 6qUG and 2Efi and insufficient detail on the geodesic scoring procedure.\n\nThe main priority for the rebuttal is to provide stronger empirical evidence that isolates the source of the reported performance gains. In particular, the authors should clarify the respective contributions of the learned representation, the pullback metric, and the inertia-induced geodesic scoring procedure. If the authors can address this point and the remaining clarification issues, I believe many of the current concerns would be resolved.",+ "final_justification": "During rebuttal, the authors addressed the central concern raised in my initial meta-review about the source of the reported gains. In particular, they provided the requested $(3\\times2)$ ablation separating the effects of the fine-tuning objective, the decoder pullback, and the inertia-induced metric. They also added subject-level confidence intervals, repeated-subject-split results, and comparisons with published motion priors. These additions make the empirical contribution considerably clearer and, in my view, resolve the main attribution issue. Accordingly, Reviewer 2Efi increased the score, and Reviewer NdY6 agreed that most of the original concerns had been addressed.\n\n(1) *Methodological Contribution and Technical Soundness*: I view this as a meaningful formulation-level contribution. Rather than serving only as a post-hoc regularizer, the mechanically determined inertia geometry shapes both the learned representation and its geodesic readout for clinical gait phenotyping. This gives the representation a clear biomechanical interpretation and is particularly relevant in the limited-data setting, since the inertia matrix is obtained from the body model and pose rather than estimated from the clinical cohort. More importantly, the new ablation shows that both the fine-tuning objective and the scoring geometry contribute to the final performance, with their combination giving the strongest results. Reviewer 6qUG also finds the method technically sound and considers the authors' explanations of the inertia matrix and geodesic computation satisfactory.\n\n(2) *Empirical Evaluation and Robustness*: The evaluation covers disease discrimination, data-scarcity settings, and severity analysis across external cohorts. In response to the reviews, the authors strengthened this evaluation with comparisons to VPoser and GaitForeMer, repeated splits, and confidence intervals. During the subsequent discussion, Reviewer NdY6 identified two discrepancies: the original nearest-neighbor graph made the evaluation transductive, and the reported results used a constant approximation rather than the pointwise pullback metric described in the paper. The authors acknowledged both issues and repeated the evaluation using an inductive graph and the pointwise metric. The main results remained essentially unchanged. I therefore view these discrepancies as correctable protocol issues rather than problems that alter the main empirical conclusion. The corrected protocol and results should be documented clearly in the final revision.\n\nThe main remaining concern is the scope of the contribution. At present, the evaluation covers only a limited number of motion priors and datasets, and broader validation would strengthen the paper. Even so, I consider the contribution within the current scope non-trivial. In particular, defining both the representation and its readout through inertia-induced geometry is novel and technically meaningful. The new ablations further show that both parts of the design contribute to performance. Moreover, the main results remain essentially unchanged after correcting the evaluation protocol. In my assessment, the paper's conceptual and empirical strengths therefore outweigh this limitation.\n\nIn summary, the rebuttal has addressed the central concern in my initial meta-review and strengthened the evidence for the proposed method. For this reason, I consider this paper a good candidate for acceptance and encourage the authors to report the corrected inductive evaluation, distinguish the pointwise metric from its constant approximation as well as clarify the scope of the contribution in the final version."},"createdAt": "2026-07-22T11:41:01.653Z",- "modifiedAt": "2026-11-18T15:22:24.830Z",+ "modifiedAt": "2026-11-19T05:01:28.596Z","url": "https://openreview.net/forum?id=6Ku1AhEjKl¬eId=fRHwLijVFm","license": "CC-BY-4.0"}
reviews/openreview/6ku1ahejkl/notes/hbyohsrtn1.json added
+++ b/reviews/openreview/6ku1ahejkl/notes/hbyohsrtn1.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "HbyOhsrtn1",+ "replyTo": "vyoDqOs3wr",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer NdY6",+ "content": {+ "comment": "Thank you for the detailed rebuttal and the added experiments. The response addresses most of my concerns.\n\n1. The ablation addressing W1 and Q1 does separate the training objective from the scoring distance, which was the main missing comparison. Adding $L_{\\mathrm{rec}}$ improves the Euclidean AUROC significantly, and using the geodesic score with the PhysPT encoder improves it as well. The full method's results being at 0.8958 shows that both components contribute and that their combination is important.\n\n2. The external baselines also strengthen the paper's evaluation. The margin over GaitForeMer is substantial under the shared protocol. The repeated splits and paired bootstrap intervals do reduce my concern about the small test set. The intervals exclude zero for all reported values of $K$. The rebuttal also gives the cohort sizes and the HC/PD test composition.\n\nI have two remaining questions.\n1. The authors state in the rebuttal that the $k$-NN graph is built over \"all windows.\" Does this include all held-out HC, PD, and other-disease windows at the same time? If yes, the evaluation is transductive. A subject's score can then depend on the other test subjects. Please state exactly which windows are in the graph. An inductive test should use only the training-HC graph and the current test subject, or attach each test embedding to a fixed training graph.\n\n2. The authors also mention in the rebuttal that $J$ is estimated with ridge regression and that $M$ is the mean inertia matrix of the training HC subjects. This appears to give a fixed global metric $G = J^\\top M J$. The paper instead describes a configuration-dependent pullback metric that uses the decoder Jacobian and $M(\\hat{q})$. Please explain this difference. Also separate the effect of the fixed anisotropic metric from the effect of graph shortest paths. Please state the number of random splits used for the reported mean and standard deviation.\n\nIf the graph does not introduce problematic test-set dependence, I will consider raising my rating. Thank you."+ },+ "createdAt": "2026-07-31T15:48:29.027Z",+ "modifiedAt": "2026-11-19T17:16:47.942Z",+ "url": "https://openreview.net/forum?id=6Ku1AhEjKl¬eId=HbyOhsrtn1",+ "license": "CC-BY-4.0"+}
reviews/openreview/6ku1ahejkl/notes/htlg5kmass.json added
+++ b/reviews/openreview/6ku1ahejkl/notes/htlg5kmass.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "HTLg5kmass",+ "replyTo": "QM9iwEoArI",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "## We thank the reviewer for the detailed review, and wanted to follow up in case anything in our response is still open.\n\n**Isolate the source of the reported improvements (follow-up)** \nAs the ablation table shows, both L_rec, which is what changes the encoder, and the geodesic contribute to the improvement, with L_rec the larger of the two \n\n\n**Comparison to external baselines (follow-up)** \nThe table in our previous message did not render, so we repost it here. \n\n| Method | HC/PD | HC/all |\n|---|---|---|\n| VPoser | 0.5743 | 0.6224 |\n| GaitForeMer | 0.7135 | 0.7577 |\n| Ours | **0.8958** | **0.8678** |\n\nBelow is the protocol of external baselines\n\n**Setup:** Both baselines are evaluated with frozen backbones, following CARE-PD’s convention for pretrained encoders (its classifier_only mode freezes the backbone). The 20 HC subjects define the reference set and are not used to adapt either model.\n\n**Shared protocol:** Each recording is divided into 16-frame windows sampled at 30 fps. For each window, we extract a latent representation using the corresponding frozen encoder and compute its anomaly score using the geodesic procedure described in Sec 3.5. A subject-level score is obtained by taking the median across all windows from that subject. AUROC is computed on the 8 held-out HC against the 30 PD subjects (HC/PD) and against the 30 PD plus 39 other-disease subjects (HC/all).\n\n**VPoser:** We use the V02_05 checkpoint pretrained on AMASS. Because it is a per-frame pose with no temporal axis, each frame is encoded independently, and the window defines only the interval over which we average. For each frame we encode the 21 SMPL body-pose joints and take the 32-dimensional posterior mean. The window latent representation is the average over the 16 frames.\n\n**GaitForeMer:** We use the released checkpoint pre-trained on NTU RGB+D. We feed CARE-PD’s 3D Human3.6M joints, reindexed to the checkpoint’s joint ordering. The window latent representation is the temporally pooled encoder output.\n\n\n\nPlease let us know if anything is still unclear."+ },+ "createdAt": "2026-07-31T15:00:24.240Z",+ "modifiedAt": "2026-11-19T17:16:48.154Z",+ "url": "https://openreview.net/forum?id=6Ku1AhEjKl¬eId=HTLg5kmass",+ "license": "CC-BY-4.0"+}
reviews/openreview/6ku1ahejkl/notes/tyz3yulsmn.json added
+++ b/reviews/openreview/6ku1ahejkl/notes/tyz3yulsmn.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "TyZ3yUlSmn",+ "replyTo": "fRHwLijVFm",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the AC and the reviewers for the follow-up.\n\nReviewer 2Efi confirmed that the 3x2 ablation, the confidence intervals and the split variability address their Major Weaknesses 1 and 2. We have also supplied the protocol behind the external baselines. \n\nReviewer 6qUG confirmed that the justification for the inertia matrix and the geodesic implementation details are now clear. We will move both into the final manuscript.\n\nReviewer NdY6 raised two follow-up questions after our rebuttal, which we answered as follows. \n(1) The k-NN graph in the submitted results contained all windows, which makes the evaluation transductive. We reran it inductively, with the graph restricted to the training healthy controls plus one test subject at a time, and the result changes by at most 0.0127 AUROC. \n(2) Separately, Sec 3.5 describes a pointwise pullback metric while the submitted numbers were computed with a constant approximation of it. We apologise for the inconsistency. We have now evaluated the pointwise metric: it differs from the approximation by at most 0.0217 AUROC, and is three orders of magnitude more expensive to construct. The revision will report the pointwise metric throughout and describe the scoring procedure in full."+ },+ "createdAt": "2026-08-04T07:26:48.064Z",+ "modifiedAt": "2026-11-19T17:16:47.878Z",+ "url": "https://openreview.net/forum?id=6Ku1AhEjKl¬eId=TyZ3yUlSmn",+ "license": "CC-BY-4.0"+}
reviews/openreview/6ku1ahejkl/notes/wxp3n0c7v9.json added
+++ b/reviews/openreview/6ku1ahejkl/notes/wxp3n0c7v9.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Wxp3N0c7v9",+ "replyTo": "Oophp7rtt4",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 6qUG",+ "content": {+ "comment": "We thank the authors for the detailed rebuttal and have considered each response.\n(1) We appreciate the clarification on the intended methodological contribution and the additional ablation isolating the effects of the geometry and reconstruction loss. We acknowledge the distinction the authors make regarding the proposed representation space. However, our assessment of the paper's methodological novelty remains unchanged, as we still view the overall framework as primarily extending the existing PhysPT architecture using established inertia-induced Riemannian geometry concepts. \n(2) The explanation for choosing the inertia matrix over other biomechanical quantities satisfactorily addresses our question. We encourage the authors to incorporate this discussion into the manuscript.\n(3) The added details on the geodesic computation sufficiently clarify the implementation and should be included in the paper for reproducibility.\n(4) Thank you for correcting the broken cross-reference.\nWe appreciate the clarifications provided in the rebuttal. While they improve the presentation of the work, our overall assessment remains unchanged. We maintain our rating of 4: Borderline accept."+ },+ "createdAt": "2026-07-29T10:13:19.392Z",+ "modifiedAt": "2026-11-19T17:16:48.096Z",+ "url": "https://openreview.net/forum?id=6Ku1AhEjKl¬eId=Wxp3N0c7v9",+ "license": "CC-BY-4.0"+}
reviews/openreview/6ku1ahejkl/notes/xgxtrvrwvj.json added
+++ b/reviews/openreview/6ku1ahejkl/notes/xgxtrvrwvj.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "XgXTRVRwvj",+ "replyTo": "Wxp3N0c7v9",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for carefully considering our rebuttal. We appreciate that the rationale for choosing the inertia matrix and the details of the geodesic computation are now clear, and we will incorporate these into the manuscript.\n\nWe also understand the remaining reservation regarding methodological novelty and acknowledge that the underlying ingredients are established. We appreciate the reviewer's recognition of the distinction regarding the proposed representation space and will position our contribution more precisely at the level of formulation: using the mechanically determined inertia geometry, computed directly from the body model and pose, to structure a learned representation and its geodesic readout for clinical gait phenotyping."+ },+ "createdAt": "2026-07-31T19:55:47.351Z",+ "modifiedAt": "2026-11-19T17:16:48.119Z",+ "url": "https://openreview.net/forum?id=6Ku1AhEjKl¬eId=XgXTRVRwvj",+ "license": "CC-BY-4.0"+}
reviews/openreview/6ku1ahejkl/notes/xiwdhasgxz.json added
+++ b/reviews/openreview/6ku1ahejkl/notes/xiwdhasgxz.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "xiWDHaSGxz",+ "replyTo": "VvPziVjIvP",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 2Efi",+ "content": {+ "comment": "We thank the authors for the rebuttal; we have checked each component.\n\n(1), (2) We appreciate the authors running the requested 3x2 ablation and adding the confidence intervals, split variability, which together address Major Weaknesses 1 and 2.\n\n(3) No protocol is given for how the VPoser and GaitForeMer numbers were produced, so we have not taken this table into account. \n\n(4) The expansion is \"Healthy Control\", not \"Health Control\".\n\n(10) We did not mean EMG. Given a scaled musculoskeletal model, muscle-tendon lengths and hence moment arms R(q) = ∂l_MT/∂q are functions of pose alone, so this analysis is accessible from CARE-PD and would supply a second mechanically meaningful quadratic form alongside M(q). Worth noting in the Limitations, though not required for acceptance.\n\nWe update our rating to 4: Borderline accept."+ },+ "createdAt": "2026-07-29T03:10:45.275Z",+ "modifiedAt": "2026-11-19T17:16:48.119Z",+ "url": "https://openreview.net/forum?id=6Ku1AhEjKl¬eId=xiWDHaSGxz",+ "license": "CC-BY-4.0"+}