QUTCC: Quantile Uncertainty Training and Conformal Calibration for Imaging Inverse Problems
Update NeurIPS 2026 submission hIqpI82zrU: 13 notes
@openreview[bot] · 2026-11-24 15:54 UTC · f4446cb88dd9 ·
reviews/openreview/hiqpi82zru/notes/1o8rdy4m9w.json added
+++ b/reviews/openreview/hiqpi82zru/notes/1o8rdy4m9w.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "1o8RdY4m9w",+ "replyTo": "5Dzik2BYRw",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for this follow up. Following the reviewer's suggestion, we trained both Im2Im and QUTCC across 4 MRI acceleration factors to investigate whether QUTCC provides larger benefits as the reconstruction problem becomes more ill-posed. These experiments were still running at the time of our rebuttal, so we were unable to include them earlier. The results are shown below.\n\n| Acceleration | Im2Im Length | QUTCC Length | Difference (Im2Im − QUTCC) | % Shorter (QUTCC) |\n|--------------|-------------:|-------------:|---------------------------:|------------------:|\n| 4× | 0.1121 | 0.1116 | 0.0005 | 0.45% |\n| 8× | 0.1371 | 0.1348 | 0.0023 | 1.68% |\n| 12× | 0.1530 | 0.1511 | 0.0019 | 1.24% |\n| 16× | 0.1690 | 0.1643 | 0.0047 | 2.78% |\n\nQUTCC's gains generally increase as the MRI acceleration factor increases. This trend is consistent with our hypothesis that higher acceleration factors induce more spatially varying uncertainty, which provides QUTCC's spatially adaptive calibration with more structure to exploit than the global scalar calibration used by Im2Im. We agree that clarifying the regimes in which QUTCC is most beneficial would strengthen the paper, and we will incorporate this discussion into the revised manuscript."+ },+ "createdAt": "2026-07-31T21:02:53.137Z",+ "modifiedAt": "2026-11-19T16:53:05.873Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=1o8RdY4m9w",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/3worbzqev7.json added
+++ b/reviews/openreview/hiqpi82zru/notes/3worbzqev7.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "3wOrbzQev7",+ "replyTo": "uMylwoAySm",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We appreciate the reviewer's engagement during the discussion period and for taking the time to review our additional experiments and analyses. We are glad that the clarifications and additional results address your concerns, and we plan on updating the manuscript to further discuss and clarify the calibration behavior across target risk levels, including the additional results provided in this discussion. Thank you again for the thoughtful and constructive feedback throughout this process."+ },+ "createdAt": "2026-08-02T15:39:25.865Z",+ "modifiedAt": "2026-11-19T16:53:05.670Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=3wOrbzQev7",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/5dzik2byrw.json added
+++ b/reviews/openreview/hiqpi82zru/notes/5dzik2byrw.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "5Dzik2BYRw",+ "replyTo": "ro74pvfLvN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 6Kwx",+ "content": {+ "comment": "I thank the authors for their responses. The rebuttal addresses several of my concerns well: (1) the added PDF validation experiment, although on a toy problem, strengthens the claim about probability density estimation; (2) the explanation for why gains are larger in the Poisson setting is plausible and supported by the signal-dependent nature of the noise; and (3) the discussion of the real-noise results is helpful.\n\nThe main concern that remains is when QUTCC is expected to be most beneficial. For example, the authors state that “For MRI and QPI, the per-pixel uncertainty varies comparatively little across intensity (Table 1 MRI is nearly flat across bins), leaving less spatial structure for QUTCC to recover.” Would this conclusion hold for more ill-posed MRI or QPI settings. Base on this justification, we might expect higher MRI acceleration rates or more challenging subsampling masks induce more spatially varying uncertainty, in which case QUTCC could provide larger gains over scalar or partition-based baselines. However, there is no evidence to support this."+ },+ "createdAt": "2026-07-31T16:53:11.946Z",+ "modifiedAt": "2026-11-19T16:53:05.888Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=5Dzik2BYRw",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/cedsw86oel.json added
+++ b/reviews/openreview/hiqpi82zru/notes/cedsw86oel.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "cEdSw86oEL",+ "replyTo": null,+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewers and the AC for the thoughtful feedback and constructive discussion during this rebuttal period. We have responded to each review and added several new analyses, validation studies, and follow-up experiments based on the suggestions and questions raised. In addition, for some questions we have provided detailed explanations and clarifications, which we aim to expand on and incorporate more fully into the revised paper. If time permits before the discussion period ends, we would greatly appreciate any additional feedback or discussion. We are happy to clarify any remaining questions."+ },+ "createdAt": "2026-08-02T04:12:11.157Z",+ "modifiedAt": "2026-11-19T16:53:05.792Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=cEdSw86oEL",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/hwlwcrcdds.json modified
+++ b/reviews/openreview/hiqpi82zru/notes/hwlwcrcdds.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair XvgQ","content": {- "metareview": "The paper introduces QUTCC, a quantile‑conditioned U‑Net with conformal calibration for imaging inverse problems, enabling spatially adaptive uncertainty intervals and pixel‑wise conditional PDF estimation. Reviewers appreciated the method’s conceptual clarity, efficiency, and versatility, noting tighter intervals and practical integration with conformal prediction. However, they raised concerns about variable gains across tasks, limited quantitative validation of recovered PDFs, unclear attribution of improvements to quantile conditioning versus calibration, underexplored failure cases, and evaluation metrics that focus mainly on interval size without calibration plots or likelihood scores. Overall, the work is seen as technically solid and original, but with incremental novelty and incomplete experimental validation. In the rebuttal phase, the authors' responses well addressed the concerns, and two reviewers raised score to 5. The overall ratings are towards accept. Please include these revisions and check the citation mentioned in \"Citation Checker \" in the final version."+ "metareview": "The paper introduces QUTCC, a quantile‑conditioned U‑Net with conformal calibration for imaging inverse problems, enabling spatially adaptive uncertainty intervals and pixel‑wise conditional PDF estimation. Reviewers appreciated the method’s conceptual clarity, efficiency, and versatility, noting tighter intervals and practical integration with conformal prediction. However, they raised concerns about variable gains across tasks, limited quantitative validation of recovered PDFs, unclear attribution of improvements to quantile conditioning versus calibration, underexplored failure cases, and evaluation metrics that focus mainly on interval size without calibration plots or likelihood scores. Overall, the work is seen as technically solid and original, but with incremental novelty and incomplete experimental validation. In the rebuttal phase, the authors' responses well addressed the concerns, and two reviewers raised score to 5. The overall ratings are towards accept. Please include these revisions and check the citation mentioned in \"Citation Checker \" in the final version.",+ "final_justification": "The reviewers have some concerns about model validations, improvements analysis, etc. In the rebuttal phase, the authors' responses well addressed the concerns, and two reviewers raised score to 5. The overall ratings are towards accept."},"createdAt": "2026-07-23T05:39:02.185Z",- "modifiedAt": "2026-11-18T15:22:28.267Z",+ "modifiedAt": "2026-11-19T05:01:31.610Z","url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=hwLWcRcDds","license": "CC-BY-4.0"}
reviews/openreview/hiqpi82zru/notes/kleswr7hub.json added
+++ b/reviews/openreview/hiqpi82zru/notes/kleswr7hub.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "kLEsWr7hUB",+ "replyTo": "1o8RdY4m9w",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 6Kwx",+ "content": {+ "comment": "I thank the authors for including additional experiments and insight. Overall, the rebuttal by the authors addressed major concerns for this reviewer. (1) The discussion regarding real-noise and more challenging inverse problems clears where the proposed method is most beneficial, and identifies where we could expect benefit from the proposed compared to baselines. (2) Discussion on posterior estimation, while on toy, provides on authors claim on applicability of the method in posterior recovery. I therefore, will increase the score."+ },+ "createdAt": "2026-08-02T15:46:50.491Z",+ "modifiedAt": "2026-11-19T16:53:05.756Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=kLEsWr7hUB",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/mzzkpvjhog.json added
+++ b/reviews/openreview/hiqpi82zru/notes/mzzkpvjhog.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "MZzKpVjHOG",+ "replyTo": "pMtTNhqsdz",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for this comment. In our results section, we state that all methods are calibrated to the same target risk: “For fair comparison, all methods are conformally calibrated to the same target coverage with α = 0.1.” We also report the resulting empirical risks alongside the mean interval lengths in Table 6. We are happy to clarify this point further in the revised paper.\n\nThe reviewer's suggestion to include a calibration plot is valuable. To provide additional reassurance that the calibration behaves as expected across different target risk levels, we evaluated one of our models, MRI, with α = 0.1, 0.2, 0.3, and 0.4. After conformal calibration, the empirical test risks were 0.10 ± 0.03, 0.20 ± 0.04, 0.30 ± 0.04, and 0.40 ± 0.04, respectively, closely matching the desired target risks.\n\nWe chose not to include a calibration plot because the purpose of conformal calibration is precisely to adjust the prediction intervals so that they satisfy the desired coverage (or risk) guarantee. The intervals produced by the underlying methods before calibration are heuristic and are not expected to correspond to the nominal quantiles. After calibration, all methods are calibrated to the same target risk, making interval length the primary quantity that differentiates performance. For this reason, we focused our evaluation on interval length between methods."+ },+ "createdAt": "2026-07-31T16:14:32.651Z",+ "modifiedAt": "2026-11-19T16:53:05.883Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=MZzKpVjHOG",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/pmttnhqsdz.json added
+++ b/reviews/openreview/hiqpi82zru/notes/pmttnhqsdz.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "pMtTNhqsdz",+ "replyTo": "rGx3HcboRR",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer K6Yy",+ "content": {+ "title": "Follow up",+ "comment": "Thank you for the clarification regarding evaluation by interval size. This should be included in the final version of the manuscript, I believe.\nThat being said, would a calibration plot not still be insightful? Or is there an argument that it adds nothing beyond the existing evaluation? Of this, I am currently not yet convinced. Could this be added to the supplement?"+ },+ "createdAt": "2026-07-29T11:53:11.971Z",+ "modifiedAt": "2026-11-19T16:53:05.887Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=pMtTNhqsdz",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/qmgge5j2ni.json added
+++ b/reviews/openreview/hiqpi82zru/notes/qmgge5j2ni.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "QmGge5j2ni",+ "replyTo": "rRu6fN4cGf",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 6Kwx",+ "content": {+ "comment": "Thank you very much for the reminder. Updating the score also requires final recommendation and I was not sure reviewers are able to submit that before the start of AC/reviewers discussion. But I will definitely update the score at the beginning of AC/reviewer discussion period and would make sure that increased score is reflected into the discussion."+ },+ "createdAt": "2026-08-03T18:40:47.192Z",+ "modifiedAt": "2026-11-19T16:53:05.882Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=QmGge5j2ni",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/rru6fn4cgf.json added
+++ b/reviews/openreview/hiqpi82zru/notes/rru6fn4cgf.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "rRu6fN4cGf",+ "replyTo": "kLEsWr7hUB",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the thoughtful engagement during this discussion period and are glad the additional experiments addressed the major concerns raised. One small logistical note: we noticed the official rating on the review still shows the original score, so we wanted to mention it in case it was simply overlooked.\n\nThank you again for the constructive feedback throughout this process!"+ },+ "createdAt": "2026-08-03T17:23:22.191Z",+ "modifiedAt": "2026-11-19T16:53:05.661Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=rRu6fN4cGf",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/umylwoaysm.json added
+++ b/reviews/openreview/hiqpi82zru/notes/umylwoaysm.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "uMylwoAySm",+ "replyTo": "MZzKpVjHOG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer K6Yy",+ "content": {+ "title": "Thanks, this makes sense.",+ "comment": "Thanks for the response. If you include this type of clarification and additional numbers in the final version, I am happy with this."+ },+ "createdAt": "2026-08-02T09:36:10.366Z",+ "modifiedAt": "2026-11-19T16:53:05.786Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=uMylwoAySm",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/yxvzvdvzsr.json added
+++ b/reviews/openreview/hiqpi82zru/notes/yxvzvdvzsr.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "yXVZVDvZSr",+ "replyTo": "zQ5oJ2gNlS",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Summary of Discussion Period",+ "comment": "We thank the AC and reviewers for their constructive engagement throughout the discussion period. Below we summarize the main questions raised and our responses.\n\n**Reviewer 6Kwx:**\n - **When QUTCC is most beneficial:** QUTCC's advantage over Im2Im's global scalar and K-RCPS's partition-based scalars depends on the degree of spatial variation in the optimal per-pixel interval width. QUTCC adapts continuously to local image content, whereas K-RCPS is limited by its partition count. Across four MRI acceleration factors, QUTCC's gains increased with acceleration, consistent with greater spatially varying uncertainty. We will include this analysis in the revision.\n- **Performance across tasks:** QUTCC achieves the largest gains on Poisson noise because signal-dependent noise produces highly spatially varying interval widths. For real noise, the smaller improvement reflects limited diversity in the fixed training set, particularly underrepresented high-intensity pixels, rather than calibration. We will note this limitation.\n- **Model vs. calibration:** Calibrating QUTCC using the Im2Im procedure produced tighter intervals on Gaussian, Poisson, and real noise, and comparable results on QPI, indicating that both the architecture and quantile-space calibration contribute.\n- **PDF accuracy:** We added a linear-Gaussian toy problem with a known posterior, comparing QUTCC against MC-Dropout and Deep Ensembles using the same backbone. QUTCC achieved the lowest KL divergence and Wasserstein distance with a single model and two forward passes. This will be added as direct PDF validation.\n\n**Summary:** The reviewer states that the rebuttal addressed their major concerns and that they will update the score at the beginning of the AC/reviewer discussion period and ensure the increased score is reflected in the discussion.\n\n---\n**Reviewer RE4R:**\n- **Real-noise interval lengths:** We clarified that the larger intervals for high-intensity pixels arise from limited training diversity rather than calibration, as these pixels are underrepresented in the fixed real-noise dataset. We will acknowledge this limitation.\n- **Joint miscoverage:** Under monotonicity, lower- and upper-tail violations are disjoint, so per-pixel miscoverage is exactly α/2 + α/2 = α. Quantile crossings, which would violate this assumption, are rare (Appendix Table 3b).\n- **Pinball loss vs. quantile conditioning:** The requested experiment is already in the submission. The Im2Im baseline in Table 1 is Im2Im-Deep trained with pinball loss at fixed quantiles (0.05, 0.95), calibrated with Im2Im scaling, at matched architecture and depth (footnote 4, p. 7). QUTCC still yields tighter intervals, so the conditioning is doing real work. We will state this more explicitly in the revision.\n- **Extreme calibrated quantiles:** Risk remained controlled across all settings tested despite high q_hi. For very small calibration sets or very small α, control could fail as q saturates near 1. This is something we will acknowledge in the revision.\n\n---\n**Reviewer K6Yy:**\n- **Spatial correlations:** Our guarantee is per-pixel marginal, but spatial information enters through the attention U-Net, which maps shared calibrated quantiles to spatially varying interval widths using local context. Unlike Im2Im's single scalar or K-RCPS's fixed partitions, the effective scaling adapts continuously across the image. We will clarify this to avoid overclaiming.\n- **Largest/smallest valid quantiles:** We clarified that selecting the largest/smallest valid calibrated quantiles follows standard conformal calibration practice.\n- **Epistemic vs. aleatoric uncertainty:** Conformal prediction does not distinguish uncertainty sources; instead, all sources are jointly captured within a distribution-free coverage guarantee. We will clarify this.\n- **Interval width and calibration:** Since all methods are calibrated to the same target coverage (α = 0.1), interval width is the relevant measure of informativeness. Appendix Table 6 confirms empirical coverage, and additional MRI calibration experiments at α = 0.1, 0.2, 0.3, and 0.4 achieved empirical risks of 0.10 ± 0.03, 0.20 ± 0.04, 0.30 ± 0.04, and 0.40 ± 0.04, respectively. We will include these results.\n\n**Summary:** The reviewer stated that our explanations made sense and is happy with our responses to their questions."+ },+ "createdAt": "2026-08-04T05:49:10.569Z",+ "modifiedAt": "2026-11-19T16:53:05.650Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=yXVZVDvZSr",+ "license": "CC-BY-4.0"+}
reviews/openreview/hiqpi82zru/notes/zq5oj2gnls.json added
+++ b/reviews/openreview/hiqpi82zru/notes/zq5oj2gnls.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "zQ5oJ2gNlS",+ "replyTo": "hwLWcRcDds",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the AC for the thoughtful metareview and for recognizing the clarity, efficiency, and versatility of our method. In our rebuttal, we have addressed the key technical concerns raised by the reviewers. Specifically:\n\n- We clarified the settings in which QUTCC provides the greatest benefit over existing conformal image methods, including when its adaptive uncertainty estimation is most useful (Reviewer 1, Q1).\n- We added quantitative evaluations of the recovered conditional PDFs, providing additional evidence that QUTCC accurately estimates the underlying predictive distributions (Reviewer 1, Q3).\n- We investigated and explained the performance gap with K-RCPS at the highest real-noise intensity levels (0.8–1.0), identifying the factors responsible for this behavior (Reviewer 1, Q4; Reviewer 2, Q1).\n- We clarified that our interval-size comparisons are made under matched risk guarantees, making interval width the appropriate metric for comparing conformal methods (Reviewer 3, Q4).\n\nWe hope these additional analyses and clarifications demonstrate that the reviewers' primary concerns have been addressed and strengthen the empirical validation and practical understanding of QUTCC."+ },+ "createdAt": "2026-07-28T16:40:24.407Z",+ "modifiedAt": "2026-11-19T16:53:05.959Z",+ "url": "https://openreview.net/forum?id=hIqpI82zrU¬eId=zQ5oJ2gNlS",+ "license": "CC-BY-4.0"+}