Extending Pretrained 10-Second ECG Foundation Models to Longer Horizons
Update NeurIPS 2026 submission kk9jN1duEy: 18 notes
@openreview[bot] · 2026-11-24 15:54 UTC · 26b533fbc541 ·
reviews/openreview/kk9jn1duey/notes/0zjiijksi9.json added
+++ b/reviews/openreview/kk9jn1duey/notes/0zjiijksi9.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "0ZJiIjKsI9",+ "replyTo": "PLRIG0WKcZ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Following the reviewer’s suggestion, we additionally evaluate CSFM-Base, ECG-JEPA, and MERL under the same duration protocol. The complete results will be released with the revised manuscript.\n\nDuration behavior across foundation-model backbones \n\n| Task | Backbone | 10 s | 30 s | 60 s | 120 s | 180 s |\n| ---- | --------- | ----- | ----- | ----- | ----- | ----- |\n| VTaC | CSFM-Tiny | 84.10 | 88.29 | 89.01 | 89.76 | 89.50 |\n|VTaC|CSFM-Base|87.38|89.15|89.50|90.85|91.23|\n|VTaC|ECG-JEPA|78.86|82.93|86.09|89.36|91.02|\n|VTaC|MERL|61.23|76.03|80.27|83.68|82.60|\n|MC-MED ED|CSFM-Tiny|64.38|69.55|71.12|71.88|72.02|\n|MC-MED ED|CSFM-Base|64.57|69.90|72.07|72.39|72.89|\n|MC-MED ED|ECG-JEPA|66.32|67.96|72.77|73.96|72.48|\n|MC-MED ED|MERL|56.92|64.77|68.03|69.15|69.92|\n|MC-MED Acuity|CSFM-Tiny|60.17|62.54|64.14|64.74|65.18|\n|MC-MED Acuity|CSFM-Base|61.77|65.90|66.07|67.39|68.89|\n|MC-MED Acuity|ECG-JEPA|60.73|64.06|65.89|66.22|67.53|\n|MC-MED Acuity|MERL|56.43|59.24|60.24|61.85|62.39|\n|CPSC2021|CSFM-Tiny|97.24|98.91|99.23|98.90|98.86|\n|CPSC2021|CSFM-Base|96.72|98.24|98.74|99.05|99.56|\n|CPSC2021|ECG-JEPA|85.68|87.02|92.97|94.29|94.66|\n|CPSC2021|MERL|79.69|89.29|92.41|93.79|93.49|\n\n> **Q2:** *Training stability of the consistency objectives*\n\nWe thank the reviewer for this important practical question. We first clarify that the two consistency objectives use the pretrained model differently. The locality-aware objective directly preserves the inter-segment similarity structure induced by the frozen 10-second teacher. In contrast, in the dynamics-aware objective, the pretrained model is used only to identify the two segment subsets; the consistency target itself is the recording-level representation produced by the student.\n\nThe main optimization challenge was balancing the three objectives, as the supervised, locality-aware, and dynamics-aware losses operate at different numerical scales. We therefore found that their relative weighting affects final predictive performance. As reported in Appendix Table A5, the average VTaC AUC is 84.15, 85.88, 88.13, and 86.34 for $(\\lambda_{\\mathrm{local}}, \\lambda_{\\mathrm{dyn}})\\in \\{(1,1), (1,2), (0.1,1), (0.1,2)\\}$, respectively. Thus, the method is not entirely insensitive to loss weighting. We selected the loss weights empirically based on the model performance. We will further expand this discussion in the final version.\n\nFor the dynamics-aware objective, we apply stop-gradient to the recording-level target to prevent symmetric co-adaptation and stabilize local-to-global learning, following the asymmetric optimization used in BYOL [1], DINO [2], SimSiam [3], and I-JEPA [4]. What differs our method with their method are different branch and different augmentation. Unlike these methods, our two branches represent different temporal scales: local segments and the complete recording, and our views are constructed through a teacher-guided affinity partition rather than generic cropping augmentation or masking. Our novelty therefore lies in this teacher-guided local-to-global objective for model adaptation, while stop-gradient serves as the stabilization mechanism.\n\n\n\n**References.** \n[1] Grill et al., “Bootstrap Your Own Latent: A New Approach to Self-Supervised Learning,” NeurIPS 2020. \n\n[2] Caron et al., “Emerging Properties in Self-Supervised Vision Transformers,” ICCV 2021. \n\n[3] Chen and He, “Exploring Simple Siamese Representation Learning,” CVPR 2021. \n\n[4] Assran et al., “Self-Supervised Learning from Images with a Joint-Embedding Predictive Architecture,” ICCV 2023."+ },+ "createdAt": "2026-07-29T16:09:39.935Z",+ "modifiedAt": "2026-11-19T16:50:49.049Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=0ZJiIjKsI9",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/4ospsihx02.json added
+++ b/reviews/openreview/kk9jn1duey/notes/4ospsihx02.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "4ospSiHx02",+ "replyTo": "5GqoMdY5YL",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "> **W3 & L2:** *Meaning and limitations of variable-length support*\n\nWe agree that the scope of \"variable-length\" should be stated more precisely. In the current formulation, it means that a model adapted once at a maximum duration $L$ can process different input durations up to $L$ without retraining. This property is evaluated by training at 180 seconds and testing at 10, 30, 60, 120, and 180 seconds. It does not imply unrestricted extrapolation beyond the finite global positional-embedding table.\n\nWe will revise the claim accordingly and explicitly acknowledge that segment indices beyond the maximum learned length are unsupported by the current implementation. Positional mechanisms that support extrapolation beyond the trained horizon, together with streaming signal processing, are important future directions.\n\nTo evaluate generalization within the trained maximum more directly, we additionally test durations that were absent from the original evaluation grid, including partial-window cases at 15, 45, and 90 seconds in VTaC.\n\n\n|Backbone|Method|15 s AUC [95% CI]|45 s AUC [95% CI]|90 s AUC [95% CI]|\n|---|---|---|---|---|\n|CSFM-Tiny|Logit Pooling| 75.48 [69.59, 81.71]|76.45 [71.12, 82.31]|76.70 [71.97, 82.32]\n|CSFM-Tiny|Linear Probing| 71.27 [63.83, 78.87] |70.54 [61.68, 79.44]|71.69 [58.27, 78.25]|\n|CSFM-Tiny|**Ours**|**79.81 [71.40, 88.27]**|**85.42 [75.68, 91.15]**|**86.19 [76.74, 91.50]**|\n|CSFM-Base|Logit Pooling|78.40 [71.58, 84.99]|78.50 [69.57, 84.50]|77.74 [70.65, 80.11]|\n|CSFM-Base|Linear Probing|79.59 [74.13, 84.82]|78.73 [71.38, 85.63]|76.33 [68.63, 83.38]|\n|CSFM-Base|**Ours**|**83.56 [74.05, 88.93]**|**86.25 [78.72, 90.33]**|**88.38 [83.38, 93.69]**|\n|ECG-JEPA|Logit Pooling|79.35 [74.14, 83.96]|76.43 [70.21, 82.19]|77.47 [71.22, 83.21]|\n|ECG-JEPA|Linear Probing|77.67 [75.62, 86.92]|79.71 [73.60, 85.64]|80.82 [72.64, 84.48]|\n|ECG-JEPA|**Ours**|**79.60 [74.38, 83.74]**|**83.30 [77.89, 88.37]**|**86.47 [81.93, 90.69]**|\n|MERL|Logit Pooling|62.23 [56.95, 67.86]| 68.77 [62.59, 74.95]| 70.44 [65.17, 76.51]|\n|MERL|Linear Probing|67.14 [60.34, 77.34]|73.76 [67.83, 79.95]|74.15 [68.10, 80.23]|\n|MERL|**Ours**|**64.41 [60.68, 78.47]**|**74.98 [68.54, 81.73]**|**80.51 [75.05, 86.05]**|\n\n\n> **W4:** *Additional clinically relevant metrics*\n\nWe agree that ROC-AUC alone provides an incomplete clinical picture, particularly for imbalanced tasks. We are adding PR-AUC and specificity on VTaC at the 180-second horizon. Given the 26.8% positive prevalence in the VTaC test set, the lower absolute PR-AUC values are therefore expected under class imbalance. Nevertheless, our method substantially improves PR-AUC over the adaptation baselines.\n\n|Backbone|Method|ROC-AUC [95% CI]|PR-AUC [95% CI]|Specificity [95% CI]|\n|---|---|---|---|---|\n| CSFM-Tiny | Logit Pooling | 70.24 [55.48, 75.09] | 43.38 [31.66, 51.62] | 53.23 [45.89, 60.26]|\n| CSFM-Tiny | Linear Probing | 71.54 [57.14, 77.66] | 43.43 [32.20, 52.44] | 39.08 [31.83, 46.15]|\n| CSFM-Tiny | **Ours** | **87.58 [82.82, 91.37]** | **69.82 [58.21, 80.33]**|**84.62 [79.60, 88.78]**|\n| CSFM-Base | Logit Pooling | 73.92 [61.48, 79.68] | 45.36 [33.11, 52.72] | 51.38 [43.73, 58.74]|\n| CSFM-Base | Linear Probing | 74.89 [65.34, 83.06] | 48.94 [39.81, 59.84] | 59.08 [51.63, 66.39]|\n| CSFM-Base | **Ours** | **91.95 [88.08, 95.53]** | **82.89 [73.74, 90.36]**| **71.38 [65.54, 76.62]** |\n| ECG-JEPA | Logit Pooling | 74.12 [64.07, 78.10] | 51.62 [38.86, 64.99] | 65.23 [57.58, 72.78]|\n| ECG-JEPA | Linear Probing | 77.21 [70.71, 83.32] | 56.50 [43.29, 68.25] | 61.85 [54.51, 68.89]|\n| ECG-JEPA | **Ours** | **90.83 [86.21, 95.03]** | **84.79 [76.33, 91.37]**|**85.85 [81.00, 90.29]** |\n| MERL | Logit Pooling | 71.39 [67.21, 72.32] | 39.24 [30.13, 51.18] | 62.46 [55.10, 69.43]\n| MERL | Linear Probing | 72.97 [69.57, 81.26] | 49.31 [37.93, 62.09] | 48.00 [41.41, 55.17]\n| MERL | **Ours** | **81.23 [77.79, 87.74]** | **65.21 [54.34, 75.16]** | **72.62 [66.87, 77.90]** |"+ },+ "createdAt": "2026-07-29T16:15:19.166Z",+ "modifiedAt": "2026-11-19T16:50:48.969Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=4ospSiHx02",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/5gqomdy5yl.json added
+++ b/reviews/openreview/kk9jn1duey/notes/5gqomdy5yl.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "5GqoMdY5YL",+ "replyTo": "NdGYZ1sTs1",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We appreciate the reviewer's important comments. We agree that the scope of our work, statistical evaluation, and computational claims should be stated more precisely. We address each concern below.\n\n> **W1:** *Scope of \"long recordings\" and long-term monitoring*\n\nWe agree that recordings of several minutes should not be described as long-term ECG monitoring in the clinical sense. Our experiments establish extension from a 10-second pretraining horizon to longer-scale inputs, rather than modeling of days of recordings such as Holter. Although the title intentionally uses \"Longer Horizons,\" several occurrences of \"long-term\" or \"long recordings\" in the manuscript may overstate the evaluated scope. We will replace them with \"longer-horizon,\" \"extended-context,\" where appropriate.\n\nThis is a very good point, and we thank the reviewer for this insightful suggestion. We will make this clear in our final version. Our contribution is a method for adapting a pretrained 10-second foundation model to a longer duration and applying the adapted model to different durations within that range. It does not address unrestricted sequence-length extrapolation. Very long monitoring introduces distinct challenges, which might need additional non-trivial efforts , such as intensive computational cost. We mentioned this briefly in the original version (Line 353-358, Conclusion section), and we will explicitly state this boundary and position adaptation to very long recordings as an important direction for future work.\n\n> **W2 & Q1 & L3:** *Confidence intervals, statistical evaluation, and cross-validation*\n\nWe agree that the uncertainty estimates are important for the comparisons. We are therefore adding patient-level 95% bootstrap confidence intervals for the principal comparisons. In each resample, test-set patients are sampled with replacement, with all recordings and segments from the same patient kept together. The confidence interval is defined by the 2.5th and 97.5th percentiles of the resulting metric estimates. Full results will be released in our final paper.\n\n|Backbone|Method|VTaC AUC [95% CI]|VTaC ΔAUC|MC-MED ED AUC [95% CI]|MC-MED ED ΔAUC|\n|---|---|---|---|---|---|\n|CSFM-Tiny|Linear Probing|71.54 [57.14, 77.66]|+16.04|69.72 [67.23, 72.20]|+2.28|\n|CSFM-Tiny|Full Fine-tuning|81.31 [75.36, 86.93]|+6.27|70.09 [68.59, 73.71]|+1.91|\n|CSFM-Tiny|VPT|85.69 [78.78, 90.59]|+1.89|69.57 [67.11, 71.86]|+2.43|\n|CSFM-Tiny|Logit Pooling|70.24 [55.48, 75.09]|+17.34|70.17 [66.19, 72.66]|+1.83|\n|CSFM-Tiny|**Ours**|**87.58 [82.82, 91.37]**|—|**72.00 [68.74, 73.15]**|—|\n|CSFM-Base|Linear Probing|74.89 [65.34, 83.06]|+17.06|70.44 [67.80, 72.77]|+2.35|\n|CSFM-Base|Full Fine-tuning|82.66 [75.11, 89.63]|+9.29|70.30 [69.02, 74.80]|+2.49|\n|CSFM-Base|VPT|89.83 [85.13, 94.46]|+2.12|71.59 [69.95, 74.74]|+1.20|\n|CSFM-Base|Logit Pooling|73.92 [61.48, 79.68]|+18.03|71.22 [70.06, 73.43]|+1.57|\n|CSFM-Base|**Ours**|**91.95 [88.08, 95.53]**|—|**72.79 [70.49, 75.42]**|—|\n|ECG-JEPA|Linear Probing|77.21 [70.71, 83.32]|+13.62|70.85 [68.34, 73.32]|+2.20|\n|ECG-JEPA|Full Fine-tuning|88.68 [84.05, 92.79]|+2.15|68.31 [65.57, 71.38]|+4.74|\n|ECG-JEPA|VPT|89.39 [85.08, 95.18]|+1.44|72.11 [66.81, 73.50]|+0.94|\n|ECG-JEPA|Logit Pooling|74.12 [64.07, 78.10]|+16.71|68.91 [65.15, 72.79]|+4.14|\n|ECG-JEPA|**Ours**|**90.83 [86.21, 95.03]**|—|**73.05 [67.32, 74.47]**|—|\n|MERL|Linear Probing|72.97 [69.57, 81.26]|+8.26|68.05 [65.62, 70.58]|+2.16|\n|MERL|Full Fine-tuning|87.46 [82.24, 92.23]|−6.23|68.33 [65.73, 70.86]|+1.88|\n|MERL|VPT|82.83 [75.96, 86.39]|−1.60|69.38 [66.04, 71.78]|+0.83|\n|MERL|Logit Pooling|71.39 [67.21, 72.32]|+9.84|68.12 [65.44, 70.12]|+2.09|\n|MERL|**Ours**|**81.23 [77.79, 87.74]**|—|**70.21 [66.61, 72.52]**|—|"+ },+ "createdAt": "2026-07-29T16:13:52.493Z",+ "modifiedAt": "2026-11-19T16:50:48.747Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=5GqoMdY5YL",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/6o0gblunrj.json added
+++ b/reviews/openreview/kk9jn1duey/notes/6o0gblunrj.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "6o0GBLUnrj",+ "replyTo": "Tosob0JMTC",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "> **Q2:** *Generality across Architectures and Teacher Backbones*\n\nMost publicly available ECG foundation models that support single-lead evaluation are pretrained on 10-second recordings, which is precisely where they fall short in the longer-horizon scenarios considered here. How this limitation manifests, however, depends on the backbone architecture. *Transformer-based* models do not necessarily need any adaptation for the lead dimension and can work directly on single-lead input, but their positional embeddings are still tied to the 10-second horizon, such as CSFM and ECG-JEPA. *Convolutional-based* models are different: the lead structure is baked into the input channels, so a model precisely trained on single-lead is required. Although a fully convolutional model can directly accept longer temporal inputs without positional-embedding extension, it commonly obtains the final representation through global average pooling over the temporal feature map. This preserves locally extracted patterns but does not explicitly model the ordering and interactions among distant ECG segments.\n\nThis distinction also explains why Transformers have become increasingly common in ECG foundation models: token-level attention provides an explicit mechanism for capturing dependencies and interactions across temporal segments, while also supporting flexible adaptation to downstream tasks. To provide a convolutional comparison, we additionally evaluate CLEF [1], a publicly available single-lead ResNeXt1D foundation model, against CSFM-Base under the same 180-second linear-probing protocol.\n\n|Architecture|Backbone|VTaC ROC-AUC [95% CI]|MC-MED ED ROC-AUC [95% CI]|\n|---|---|---|---|\n|Convolutional|CLEF|72.76 [65.13, 81.82]|64.86 [60.47, 68.42]|\n|Transformer|CSFM-Base|74.89 [65.34, 83.06]|70.44 [67.80, 72.77]|\n\nWe also agree that semantic extension depends on the quality of the teacher representation. This dependence is already examined in Table 2: at 180 seconds, MERL self-guidance achieves 82.60 AUC on VTaC, while guidance from CSFM-Tiny, CSFM-Base, and ECG-JEPA improves it to 85.19, 86.07, and 85.78, respectively. Importantly, this indicates that the performance of a fine-tuned model is related to the quality of its base model, which is natural, but a weaker student can benefit from a stronger external teacher. We further add the performance of CSFM-tiny guided by a stronger CSFM-Base.\n\n|Guidance|10s |30s |60s |120s |180s |\n| :----- | :-- | :-- | :-- | :-- |---: | \n|Self-guided|84.10|88.29|89.01|89.76|89.50|\n|CSFM-Base guided|85.38|89.02|89.50|89.85|90.22|\n\nWe will make this analysis more prominent and explicit in the final version.\n\n**References.** \n[1] Shu et al., “CLEF: Clinically-Guided Contrastive Learning for Electrocardiogram Foundation Models,” arXiv 2025."+ },+ "createdAt": "2026-07-29T16:21:54.811Z",+ "modifiedAt": "2026-11-19T16:50:48.599Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=6o0GBLUnrj",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/ctanrrfoh0.json added
+++ b/reviews/openreview/kk9jn1duey/notes/ctanrrfoh0.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "CTanrrFOh0",+ "replyTo": "r1hTWDyepS",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": ">**W4: Sensitivity, Operating Threshold, and Bootstrap Details**\n\nWe appreciate the reviewer’s careful follow-up and thank you for catching this omission (many thanks again, we missed that!). This is an important point: reporting specificity without sensitivity does not fully characterize the clinical operating point and may lead to an incomplete interpretation of model utility. Following the reviewer’s suggestion, we now report sensitivity with 95% confidence intervals alongside specificity. These additional results improves the clinical transparency of our evaluation.\n\nFor each backbone–method combination, we select the operating threshold exclusively on the validation set by maximizing Youden’s $J$, defined as $\\mathrm{sensitivity}+\\mathrm{specificity}-1$. This threshold is then fixed and applied unchanged to the test set when calculating both sensitivity and specificity.\n\nFor clarity, all reported 95% confidence intervals are based on **5,000 patient-level bootstrap replicates**. In each replicate, test patients are sampled with replacement, with all recordings belonging to the same patient kept together.\n\n\n|Backbone|Method|ROC-AUC [95% CI]|PR-AUC [95% CI]|Sensitivity [95% CI]|Specificity [95% CI]|\n|---|---|---|---|---|---|\n| CSFM-Tiny | Logit Pooling | 70.24 [55.48, 75.09] | 43.38 [31.66, 51.62] | 67.73 [54.80, 82.53]| 53.23 [45.89, 60.26]|\n| CSFM-Tiny | Linear Probing | 71.54 [57.14, 77.66] | 43.43 [32.20, 52.44] | 73.91 [61.70, 85.74] | 39.08 [31.83, 46.15]|\n| CSFM-Tiny | **Ours** | **87.58 [82.82, 91.37]** | **69.82 [58.21, 80.33]**|**78.45 [65.46, 84.54]**|**84.62 [79.60, 88.78]**|\n| CSFM-Base | Logit Pooling | 73.92 [61.48, 79.68] | 45.36 [33.11, 52.72] | 72.27 [61.80, 82.93] | 51.38 [43.73, 58.74]|\n| CSFM-Base | Linear Probing | 74.89 [65.34, 83.06] | 48.94 [39.81, 59.84] | 78.15 [62.85, 91.55] | 59.08 [51.63, 66.39]|\n| CSFM-Base | **Ours** | **91.95 [88.08, 95.53]** | **82.89 [73.74, 90.36]**| **93.28 [88.43, 97.58]** | **71.38 [65.54, 76.62]** |\n| ECG-JEPA | Logit Pooling | 74.12 [64.07, 78.10] | 51.62 [38.86, 64.99] | 76.47 [68.63, 84.07] | 65.23 [57.58, 72.78]|\n| ECG-JEPA | Linear Probing | 77.21 [70.71, 83.32] | 56.50 [43.29, 68.25] | 82.35 [75.24, 89.16] | 61.85 [54.51, 68.89]|\n| ECG-JEPA | **Ours** | **90.83 [86.21, 95.03]** | **84.79 [76.33, 91.37]**|**82.35 [72.11, 90.82]**|**85.85 [81.00, 90.29]** |\n| MERL | Logit Pooling | 71.39 [67.21, 72.32] | 39.24 [30.13, 51.18] | 75.63 [66.06, 84.87] | 62.46 [55.10, 69.43]\n| MERL | Linear Probing | 72.97 [69.57, 81.26] | 49.31 [37.93, 62.09] | 91.60 [86.18, 96.49] | 48.00 [41.41, 55.17]\n| MERL | **Ours** | **81.23 [77.79, 87.74]** | **65.21 [54.34, 75.16]** | **75.63 [67.83, 83.50]** | **72.62 [66.87, 77.90]** |\n\nThe reviewer’s suggestion makes the trade-off much clearer. For example, MERL with linear probing achieves 91.60% sensitivity but only 48.00% specificity, meaning that it detects most positive cases at the cost of many false positives. Its high sensitivity therefore does not indicate stronger overall performance, as also reflected by its moderate ROC-AUC (72.97%) and PR-AUC (49.31%). We appreciate this helpful observation, which enables a more clinically meaningful interpretation of the results."+ },+ "createdAt": "2026-08-01T15:44:42.408Z",+ "modifiedAt": "2026-11-19T16:50:48.769Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=CTanrrFOh0",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/e3fgnnh4sw.json added
+++ b/reviews/openreview/kk9jn1duey/notes/e3fgnnh4sw.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "E3fGnnH4sw",+ "replyTo": "J2Oz7ttVDG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer HjLT",+ "content": {+ "comment": "Dear authors, thanks for preparing the response. I acknowledge I have carefully read and considered them in my final justification."+ },+ "createdAt": "2026-08-03T09:33:35.403Z",+ "modifiedAt": "2026-11-19T16:50:48.525Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=E3fGnnH4sw",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/ewqvorcz3z.json added
+++ b/reviews/openreview/kk9jn1duey/notes/ewqvorcz3z.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "EwqVorcz3Z",+ "replyTo": "Tosob0JMTC",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "> **L2:** *Statistical uncertainty*\n\nWe agree that point estimates alone are insufficient to establish whether smaller differences are reliable. We therefore compute patient-level bootstrap confidence intervals and paired bootstrap comparisons from predictions on the same test sets. We use the 2.5th and 97.5th percentiles of the bootstrap distribution as the interval bounds and will include the complete results in the revised manuscript.\n\nWe also tested D-BETA and MELP, but found that a controlled 180-second adaptation was not computationally feasible under our current resources. D-BETA and MELP both employ four stride-2 convolutional layers followed by an eight-layer Transformer. The resulting downsampling factor is only 16, producing approximately **312** tokens for their native 10-second input and **5,625** tokens for a 180-second recording. Compared with approximately 1,800 tokens for CSFM. This corresponds to 3.1$\\times$ more tokens and nearly 9.8$\\times$ larger attention matrices per layer. Consequently, direct end-to-end adaptation exceeded our available GPU memory, even with mixed precision.\n\n\n|Backbone|Method|VTaC AUC [95% CI]|VTaC ΔAUC|MC-MED ED AUC [95% CI]|MC-MED ED ΔAUC|\n|---|---|---|---|---|---|\n|CSFM-Tiny|Linear Probing|71.54 [57.14, 77.66]|+16.04|69.72 [67.23, 72.20]|+2.28|\n|CSFM-Tiny|Full Fine-tuning|81.31 [75.36, 86.93]|+6.27|70.09 [68.59, 73.71]|+1.91|\n|CSFM-Tiny|VPT|85.69 [78.78, 90.59]|+1.89|69.57 [67.11, 71.86]|+2.43|\n|CSFM-Tiny|Logit Pooling|70.24 [55.48, 75.09]|+17.34|70.17 [66.19, 72.66]|+1.83|\n|CSFM-Tiny|**Ours**|**87.58 [82.82, 91.37]**|—|**72.00 [68.74, 73.15]**|—|\n|CSFM-Base|Linear Probing|74.89 [65.34, 83.06]|+17.06|70.44 [67.80, 72.77]|+2.35|\n|CSFM-Base|Full Fine-tuning|82.66 [75.11, 89.63]|+9.29|70.30 [69.02, 74.80]|+2.49|\n|CSFM-Base|VPT|89.83 [85.13, 94.46]|+2.12|71.59 [69.95, 74.74]|+1.20|\n|CSFM-Base|Logit Pooling|73.92 [61.48, 79.68]|+18.03|71.22 [70.06, 73.43]|+1.57|\n|CSFM-Base|**Ours**|**91.95 [88.08, 95.53]**|—|**72.79 [70.49, 75.42]**|—|\n|ECG-JEPA|Linear Probing|77.21 [70.71, 83.32]|+13.62|70.85 [68.34, 73.32]|+2.20|\n|ECG-JEPA|Full Fine-tuning|88.68 [84.05, 92.79]|+2.15|68.31 [65.57, 71.38]|+4.74|\n|ECG-JEPA|VPT|89.39 [85.08, 95.18]|+1.44|72.11 [66.81, 73.50]|+0.94|\n|ECG-JEPA|Logit Pooling|74.12 [64.07, 78.10]|+16.71|68.91 [65.15, 72.79]|+4.14|\n|ECG-JEPA|**Ours**|**90.83 [86.21, 95.03]**|—|**73.05 [67.32, 74.47]**|—|\n|MERL|Linear Probing|72.97 [69.57, 81.26]|+8.26|68.05 [65.62, 70.58]|+2.16|\n|MERL|Full Fine-tuning|87.46 [82.24, 92.23]|−6.23|68.33 [65.73, 70.86]|+1.88|\n|MERL|VPT|82.83 [75.96, 86.39]|−1.60|69.38 [66.04, 71.78]|+0.83|\n|MERL|Logit Pooling|71.39 [67.21, 72.32]|+9.84|68.12 [65.44, 70.12]|+2.09|\n|MERL|**Ours**|**81.23 [77.79, 87.74]**|—|**70.21 [66.61, 72.52]**|—|\n\n> **L3:** *Relationship to stop-gradient representation learning*\n\nOur dynamics-aware objective adopts the asymmetric optimization principle of existing stop-gradient methods, but differs in its **branches, view construction, teacher role, and learning goal**. Rather than aligning two cropped or masked views [1] [2], we align selected signal segment representations with a representation of the complete recording, forming an explicit local-to-global, cross-scale objective. The local views are constructed through a affinity partition defined by the frozen backbone, instead of generic signal augmentation or random masking. Moreover, the pretrained teacher only guides segment partitioning; it is neither the recording-level target nor an online teacher. Our novelty therefore lies in using teacher-guided view construction and cross-scale alignment to extend snapshot ECG knowledge to longer recordings, rather than in stop-gradient itself.\n\nStop-gradient serves as a stabilization mechanism for this objective [3]. Without it, the local representations and recording-level target can co-adapt simply to reduce the consistency loss, and will easily lead to a trivial solution. We therefore stop its gradient at the recording-level branch, providing a stable target within each forward pass.\n\n**References.** \n\n[1] Caron et al., “Emerging Properties in Self-Supervised Vision Transformers,” ICCV 2021. \n\n[2] Assran et al., “Self-Supervised Learning from Images with a Joint-Embedding Predictive Architecture,” ICCV 2023. \n\n[3] Chen and He, “Exploring Simple Siamese Representation Learning,” CVPR 2021."+ },+ "createdAt": "2026-07-29T16:22:48.725Z",+ "modifiedAt": "2026-11-19T16:50:48.524Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=EwqVorcz3Z",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/gcutwp82ap.json added
+++ b/reviews/openreview/kk9jn1duey/notes/gcutwp82ap.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "GCUTwp82aP",+ "replyTo": "PLRIG0WKcZ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "The complete variable-length results are provided in Appendix B.1 (Figure A1). We reproduce representative numerical values here for convenience. Many existing adaptation methods are competitive at the horizon they were tuned for, but generalize poorly to substantially shorter inputs. For example, on VTaC with CSFM-Tiny, VPT achieves 88.18 AUC at 180 seconds but decreases to 60.78 at 10 seconds, whereas our single adapted model leads at every duration. This is precisely the variable-length behavior the method is designed to provide. \n\nVaried-horizon comparison using CSFM-Tiny\n\n| Task | Method | 10 s | 30 s | 60 s | 120 s | 180 s |\n| :------------------ | :--------------- | ----: | ----: | ----: | ----: | ----: |\n| **VTaC** | Token Pooling | 79.23 | 77.94 | 75.71 | 74.25 | 74.05 |\n| | Logit Pooling | 78.23 | 77.45 | 75.51 | 74.14 | 73.83 |\n| | Full Fine-tuning | 64.10 | 63.26 | 70.89 | 75.42 | 79.01 |\n| | Linear Probing | 72.93 | 71.30 | 71.22 | 70.57 | 69.50 |\n| | Partial Tuning | 64.94 | 65.84 | 69.80 | 80.79 | 86.49 |\n| | Bias Tuning | 68.32 | 68.70 | 65.40 | 65.32 | 64.43 |\n| | Adapter | 67.63 | 70.37 | 69.70 | 77.12 | 79.33 |\n| | VPT | 60.78 | 67.44 | 74.37 | 80.86 | 88.18 |\n| | LSTM Tuning | 79.04 | 82.53 | 84.28 | 84.22 | 84.97 |\n| | **Ours** | **84.10** | **88.29** | **89.01** | **89.76** | **89.50** |\n| **MC-MED (ED)** | Token Pooling | 64.10 | 68.77 | 69.61 | 70.32 | 70.80 |\n| | Logit Pooling | 65.49 | 69.00 | 70.16 | 70.61 | 71.15 |\n| | Full Fine-tuning | 63.31 | 67.13 | 68.76 | 70.45 | 70.81 |\n| | Linear Probing | 62.72 | 66.12 | 67.31 | 68.91 | 69.38 |\n| | Partial Tuning | 62.30 | 67.52 | 69.95 | 71.68 | 70.91 |\n| | Bias Tuning | 63.23 | 65.74 | 66.71 | 67.61 | 68.13 |\n| | Adapter | 63.60 | 68.24 | 69.49 | 70.44 | 71.24 |\n| | VPT | 58.61 | 66.75 | 69.16 | 70.77 | 71.19 |\n| | LSTM Tuning | 52.43 | 65.07 | 66.95 | 70.13 | 71.31 |\n| | **Ours** | **64.38** | **69.55** | **71.12** | **71.88** | **72.02** |\n| **MC-MED (Acuity)** | Token Pooling | 58.77 | 59.09 | 60.2 | 60.92 | 61 |\n| | Logit Pooling | 59.19 | 59.82 | 60.25 | 60.41 | 60.13 |\n| | Full Fine-tuning | 62.1 | 61.89 | 63.02 | 63.54 | 64.8 |\n| | Linear Probing | 58.38 | 60.78 | 60.01 | 60.56 | 60.66 |\n| | Partial Tuning | 61.4 | 62.07 | 63.09 | 65.33 | 63.43 |\n| | Bias Tuning | 51.65 | 52.12 | 55.63 | 56.35 | 56.71 |\n| | Adapter | 60.31 | 59.36 | 60.02 | 61.42 | 61.55 |\n| | VPT | 56.33 | 60.39 | 61.51 | 63.38 | 64.5 |\n| | LSTM Tuning | 51.08 | 58.29 | 61.66 | 60.98 | 61.97 |\n| | **Ours** | **60.17** | **62.54** | **64.14** | **64.74** | **65.18** |\n| **CPSC2021** | Token Pooling | 95.89 | 96.74 | 96.72 | 96.79 | 96.81 |\n| | Logit Pooling | 97.00 | 97.42 | 97.37 | 97.28 | 97.23 |\n| | Full Fine-tuning | 90.08 | 93.54 | 93.17 | 95.13 | 94.24 |\n| | Linear Probing | 97.87 | 97.01 | 96.7 | 96.54 | 96.46 |\n| | Partial Tuning | 92.14 | 95.12 | 95.43 | 96.16 | 95.48 |\n| | Bias Tuning | 95.38 | 97.39 | 98.42 | 98.44 | 98.46 |\n| | Adapter | 91.09 | 96.16 | 97.92 | 98.02 | 98.01 |\n| | VPT | 89.54 | 96.41 | 98.52 | 98.69 | 98.67 |\n| | LSTM Tuning | 97.09 | 98.48 | 98.00 | 98.13 | 98.75 |\n| | **Ours** | **97.24** | **98.91** | **99.23** | **98.90** | **98.86** |"+ },+ "createdAt": "2026-07-29T16:08:20.870Z",+ "modifiedAt": "2026-11-19T16:50:48.753Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=GCUTwp82aP",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/j2oz7ttvdg.json added
+++ b/reviews/openreview/kk9jn1duey/notes/j2oz7ttvdg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "J2Oz7ttVDG",+ "replyTo": "EwqVorcz3Z",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "> **L4:** *Ten-second segment boundaries*\n\nWe thank the reviewer for highlighting this practical concern. To quantify the effect of segment boundaries, we compare frozen-backbone logit pooling using non-overlapping 10-second windows (10-second stride) and 50%-overlapping windows (5-second stride), while keeping the data splits and optimization unchanged.\n\nAt the 180-second horizon, reducing the stride from 10 to 5 seconds increases the number of encoded windows, corresponding to approximately 1.94× more computation costs. The overlapping setting changes AUC from 70.24 to 70.32, indicating that denser window coverage provides only a limited benefit. This suggests that non-overlapping segmentation is a reasonable efficiency–performance trade-off in the evaluated setting.\n\n|Window length|Stride|Overlap|Relative encoding cost|AUC [95% CI]|\n|---|---|---|---|---|\n|10 s|10 s|0%|1.00×|70.24 [55.48, 75.09]|\n|10 s|5 s|50%|1.94×|70.32 [54.70, 75.86]|"+ },+ "createdAt": "2026-07-29T16:23:39.476Z",+ "modifiedAt": "2026-11-19T16:50:48.510Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=J2Oz7ttVDG",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/n5pzykwlpy.json modified
+++ b/reviews/openreview/kk9jn1duey/notes/n5pzykwlpy.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 8QNf","content": {- "metareview": "This paper *Needs Clarification during Response Period*. It proposes a parameter-efficient framework for adapting frozen 10-second ECG foundation models to 1–5 minute recordings using hierarchical positional encoding, soft prompts, locality-aware contrastive learning, and dynamics-aware consistency. Reviewers 51AV and UWoS find the problem practical, the evaluation comprehensive, and the gains consistent across several ECG backbones, tasks, and recording durations.\n\nThe main concern is whether the evaluated 180-second setting establishes a clinically meaningful long-horizon problem. Reviewer 51AV notes that VTaC performance saturates beyond 60 seconds, while Reviewer UWoS cautions that 1–5 minutes is still far from 24–48 hour Holter monitoring. Reviewer HjLT also asks for wearable single-lead ECG evaluation, where longer monitoring is more natural than for standard 12-lead ECGs.\n\nThe empirical case would also benefit from stronger controls. The improvements are moderate, with no seed-level variance, CIs, or significance tests. Reviewer HjLT questions whether the full fine-tuning baseline is implemented fairly and notes that stronger ECG FMs, such as ECGFounder, D-BETA, and MELP, are absent. The effects of soft prompts and global positional encoding are not separated, while the gains appear to come mainly from the locality-aware loss.\n\nFinally, the claimed variable-length and parameter-efficient properties are not fully evaluated. The method uses fixed non-overlapping 10-second segments and a finite learned positional table, with no tests on unseen lengths, overlapping windows, or segment-boundary events. FLOPs, GPU memory, training time, inference latency, and parameter overhead are also missing.\n\nThe rebuttal should prioritize addressing the following concerns raised by reviewers:\n1. Results at 30, 60, 120, and 180 seconds on all tasks, compared with at least one snapshot and one fine-tuning baseline.\n2. Report Mean +- SD and paired tests or CIs for the main comparisons.\n3. Full details and verification of the fine-tuning baselines, especially how 10-second FMs are adapted and aggregated at test time.\n4. Separate ablations for soft prompts, global positional encoding, locality-aware loss, and dynamics-aware loss.\n5. Tests on unseen sequence lengths and overlapping windows, including events crossing 10-second segment boundaries.\n6. Parameter count, FLOPs, GPU memory, training time, and inference latency as sequence length increases.\n7. A wearable single-lead ECG experiment or a narrower framing of the clinical long-horizon claims."+ "metareview": "This paper *Needs Clarification during Response Period*. It proposes a parameter-efficient framework for adapting frozen 10-second ECG foundation models to 1–5 minute recordings using hierarchical positional encoding, soft prompts, locality-aware contrastive learning, and dynamics-aware consistency. Reviewers 51AV and UWoS find the problem practical, the evaluation comprehensive, and the gains consistent across several ECG backbones, tasks, and recording durations.\n\nThe main concern is whether the evaluated 180-second setting establishes a clinically meaningful long-horizon problem. Reviewer 51AV notes that VTaC performance saturates beyond 60 seconds, while Reviewer UWoS cautions that 1–5 minutes is still far from 24–48 hour Holter monitoring. Reviewer HjLT also asks for wearable single-lead ECG evaluation, where longer monitoring is more natural than for standard 12-lead ECGs.\n\nThe empirical case would also benefit from stronger controls. The improvements are moderate, with no seed-level variance, CIs, or significance tests. Reviewer HjLT questions whether the full fine-tuning baseline is implemented fairly and notes that stronger ECG FMs, such as ECGFounder, D-BETA, and MELP, are absent. The effects of soft prompts and global positional encoding are not separated, while the gains appear to come mainly from the locality-aware loss.\n\nFinally, the claimed variable-length and parameter-efficient properties are not fully evaluated. The method uses fixed non-overlapping 10-second segments and a finite learned positional table, with no tests on unseen lengths, overlapping windows, or segment-boundary events. FLOPs, GPU memory, training time, inference latency, and parameter overhead are also missing.\n\nThe rebuttal should prioritize addressing the following concerns raised by reviewers:\n1. Results at 30, 60, 120, and 180 seconds on all tasks, compared with at least one snapshot and one fine-tuning baseline.\n2. Report Mean +- SD and paired tests or CIs for the main comparisons.\n3. Full details and verification of the fine-tuning baselines, especially how 10-second FMs are adapted and aggregated at test time.\n4. Separate ablations for soft prompts, global positional encoding, locality-aware loss, and dynamics-aware loss.\n5. Tests on unseen sequence lengths and overlapping windows, including events crossing 10-second segment boundaries.\n6. Parameter count, FLOPs, GPU memory, training time, and inference latency as sequence length increases.\n7. A wearable single-lead ECG experiment or a narrower framing of the clinical long-horizon claims.",+ "final_justification": "The author response addressed the main concerns from the initial reviews. Reviewer HjLT increased the rating after the added experiments on architecture/teacher generality, the full fine-tuning protocol, statistical uncertainty, and additional ablations. Reviewers also found that concerns about metric reporting, computational cost, and uncertainty quantification were substantially addressed.\n\nThe main remaining limitation is that the claimed parameter efficiency is not supported by a direct computation-overhead analysis. Overall, however, the response resolves the salient technical and evaluation concerns sufficiently."},"createdAt": "2026-07-18T11:38:52.747Z",- "modifiedAt": "2026-11-18T15:22:46.613Z",+ "modifiedAt": "2026-11-19T05:01:43.556Z","url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=N5pzYkWlpy","license": "CC-BY-4.0"}
reviews/openreview/kk9jn1duey/notes/pgdq9bwc4j.json added
+++ b/reviews/openreview/kk9jn1duey/notes/pgdq9bwc4j.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "PGdq9bWc4j",+ "replyTo": "rV347NzAcS",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank the reviewer for taking the time to carefully read our rebuttal. We truly appreciate your thoughtful feedback. Your comments helped us better clarify the clinical motivation, optimization details, and scope of our work, and they will materially improve the overall presentation. Thank you once again for your time and kind words. We wish you all the best as well!"+ },+ "createdAt": "2026-08-03T07:16:15.030Z",+ "modifiedAt": "2026-11-19T16:50:48.474Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=PGdq9bWc4j",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/plrig0wkcz.json added
+++ b/reviews/openreview/kk9jn1duey/notes/plrig0wkcz.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "PLRIG0WKcZ",+ "replyTo": "oXhUWgZPp3",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Many thanks for the careful and constructive comments. We address the reviewer’s concerns and questions below.\n\n> **W:** *Relative contributions of the consistency objectives*\n\nWe agree with the reviewer’s observation that the locality-aware consistency loss accounts for a larger fraction of the overall improvement. This is consistent with its intended role: the pretrained 10-second encoder already provides informative representations of local ECG morphology and rhythm, and the locality-aware objective serves as the primary semantic anchor by preserving the teacher-induced inter-segment similarity structure during adaptation.\n\nThe dynamics-aware objective addresses a complementary aspect. It encourages short segment representations to retain recording-level information. The ablation reflects that design. Appendix D.1 further shows that the high- and low-affinity segment groups both contain predictive information.\n\n|Configuration|10 s|30 s|60 s|120 s|180 s|Average|\n|---|---|---|---|---|---|---|\n|Locality-aware only|83.62|87.13|88.42|89.30|89.00|87.49|\n|+ Dynamics-aware|**84.10**|**88.29**|**89.01**|**89.76**|**89.50**|**88.13**|\n|**Gain from dynamics-aware**|**+0.48**|**+1.16**|**+0.59**|**+0.46**|**+0.50**|**+0.64**|\n\nWe will revise the manuscript to state this division of roles more explicitly: locality-aware consistency provides the dominant semantic-transfer guidance, whereas dynamics-aware consistency contributes an additional recording-level constraint.\n\n> **Q1:** *Clinical interpretation of the 180-second horizon*\n\nWe agree that 180 seconds is not universally optimal for every task. Our objective is to determine whether a foundation model pretrained on 10-second snapshots can be adapted once to a longer horizon and subsequently used at different durations within that horizon without retraining. We selected 180 seconds as a common upper-bound benchmark for this purpose.\n\nThe saturation on VTaC beyond 60 seconds is an informative example of task-dependent duration requirements. Empirically, from 60 to 180 seconds, the AUC varies by only 0.5 percent, whereas the corresponding improvement from 10 to 60 seconds is 4.91 points using CSFM-Tiny. This interpretation is also consistent with the VTaC task formulation. Once sufficient rhythm and morphological context for adjudicating a ventricular-tachycardia alarm has been observed, additional context may provide limited information. \n\nIn contrast, tasks involving more slowly varying physiological states or physiological patterns that require temporal accumulation may benefit from longer observations. For example, in MC-MED, longer ECG observations may better summarize persistent or transient rhythm instability relevant to triage acuity. With our method, the AUC increases from 61.77 at 10 s to 68.89 at 180 s using CSFM-Base. Notably, extending the observation from 60 to 180 s still yields gains of 1.04–2.82 AUC points across the four backbones. Nevertheless, their optimal operational duration must also be selected based on clinical validation. Our central claim is therefore not that “longer is always better,” but that our framework enables flexible use of clinically appropriate durations beyond the original 10-second pretraining horizon."+ },+ "createdAt": "2026-07-29T16:06:20.483Z",+ "modifiedAt": "2026-11-19T16:50:49.129Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=PLRIG0WKcZ",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/r1htwdyeps.json added
+++ b/reviews/openreview/kk9jn1duey/notes/r1htwdyeps.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "r1hTWDyepS",+ "replyTo": "5GqoMdY5YL",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer UWoS",+ "content": {+ "comment": "Thank you for these additional tests.\n\n**W4: Additional clinically relevant metrics**. The additional PR-AUC analysis is helpful. However, the new table reports *specificity* but not *sensitivity*. These two metrics must be interpreted jointly at a defined operating threshold. Could you please report sensitivity with 95% CIs at the same threshold used for specificity, and state how that threshold was selected? It is an important indicator of clinical utility and transparency.\n\n**Confidence Intervals**. Could you also specify the number of bootstrap replicates for clarity?"+ },+ "createdAt": "2026-07-31T11:54:14.740Z",+ "modifiedAt": "2026-11-19T16:50:48.768Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=r1hTWDyepS",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/ruhe9ghsdc.json added
+++ b/reviews/openreview/kk9jn1duey/notes/ruhe9ghsdc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ruhE9gHSdC",+ "replyTo": "E3fGnnH4sw",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you very much for carefully reading and considering our response. We sincerely appreciate the time and care you have devoted to reviewing our work. If any questions or concerns remain, please do not hesitate to let us know. We would be very happy to provide any further clarification. Thank you again for your thoughtful comments and consideration."+ },+ "createdAt": "2026-08-03T09:44:14.682Z",+ "modifiedAt": "2026-11-19T16:50:48.313Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=ruhE9gHSdC",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/rv347nzacs.json added
+++ b/reviews/openreview/kk9jn1duey/notes/rv347nzacs.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "rV347NzAcS",+ "replyTo": "0ZJiIjKsI9",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 51AV",+ "content": {+ "title": "Thank you for the detailed rebuttal",+ "comment": "Thank you for your detailed rebuttal to my questions. I will take it into consideration for my final score and I wish the authors all the best with their submission."+ },+ "createdAt": "2026-08-02T18:29:14.314Z",+ "modifiedAt": "2026-11-19T16:50:48.746Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=rV347NzAcS",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/tosob0jmtc.json added
+++ b/reviews/openreview/kk9jn1duey/notes/tosob0jmtc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Tosob0JMTC",+ "replyTo": "y6lJMTG1JV",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for recognizing the clinical motivation and clarity of our work. The comments also reveal several aspects that were insufficiently prominent in the submission. We clarify these points below and will revise the presentation accordingly.\n\n> **Q1:** *Clinical relevance and wearable ECG foundation models*\n\nThanks for the comments. \n\nClinically, we agree that it is important to clarify the scenarios when longer ECG observations are useful. Our motivation comes from two perspectives. *Physiology-knowledge-driven*: in some applications, a 10-second snapshot may not be sufficient to capture intermittent abnormalities. For example, paroxysmal AF may not be present in an arbitrary short segment, motivating the use of longer dynamic recordings in CPSC2021. Consistent with this clinical motivation, increasing the input duration from 10 to 180 seconds improves ECG-JEPA’s AUC from 85.68 to 94.66. *Data-driven*: some downstream tasks empirically benefit from accumulating more temporal evidence. For MC-MED acuity prediction, performance improves progressively. Increasing the input duration from 10 to 180 seconds improves AUC from 60.17 to 65.18 with CSFM-Tiny, 56.43 to 62.39 with MERL, 61.77 to 68.89 with CSFM-Base, and 60.73 to 67.53 with ECG-JEPA. \n\nPlease note that in line with Reviewer 51AV **Q1**, we propose a framework to extend the capability of existing foundation models to \"longer-horizons\", rather than saying \"long-horizons\". This is because we understand extremely long horizons such as Holter recordings will incur additional computational cost, requiring non-trivial technical contributions to address. We mentioned this briefly in the original version (Line 353-358, Conclusion section), and we will make it clear in the final version.\n\nWe also appreciate the suggestion concerning wearable and single-lead models. However, publicly evaluable foundation models pretrained directly on long-term wearable ECG waveforms remain limited, except some proprietary work. For example, Apple pretrained foundation models on Apple Watch ECG and PPG waveforms, but we could not identify a publicly released checkpoint compatible with our evaluation [1]. In contrast, Google’s wearable LSM operates on per-minute streams such as heart rate and HRV rather than raw ECG waveforms [2].\n\n\n**References.** \n[1] Abbaspourazad et al., “Large-scale Training of Foundation Models for Wearable Biosignals,” ICLR 2024. \n\n[2] Narayanswamy et al., “Scaling Wearable Foundation Models,” ICLR 2025."+ },+ "createdAt": "2026-07-29T16:21:07.495Z",+ "modifiedAt": "2026-11-19T16:50:48.910Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=Tosob0JMTC",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/wlsas5gsso.json added
+++ b/reviews/openreview/kk9jn1duey/notes/wlsas5gsso.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "wlsAS5gSso",+ "replyTo": "4ospSiHx02",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "> **Q2:** *Disentangling soft prompts and global positional encoding*\n\nThe submitted Table 3 evaluates different positional-encoding strategies and shows that global positional encoding improves over repeating or interpolating the pretrained positional embeddings. However, because soft prompts are retained across these comparisons, Table 3 does not fully disentangle the independent and interactive contributions of soft prompts and global positional encoding. We agree that a factorial ablation provides a clearer answer.\n\nWe therefore evaluate all four combinations while keeping the frozen backbone, consistency objectives, projection heads, classifier, training data, and optimization protocol unchanged. When global positional encoding (GPE) is disabled, the pretrained positional embedding is extended through interpolation.\n\n|Soft prompts|GPE|10 s|30 s|60 s|120 s|180 s|\n|---|---|---|---|---|---|---|\n|✗|✗|72.93|71.3|71.22|70.57|69.5|\n|✓|✗|60.78 |67.44 |74.37 |80.86 |88.18|\n|✗|✓|74.90 | 80.03 | 78.53 | 78.43|77.76|\n|✓|✓|78.13 |83.96 |87.45| 89.08| 88.92|\n\nThe comparison reveals complementary and interactive contributions. GPE alone improves the baseline across all durations, while soft prompts provide larger gains at longer horizons. In particular, adding GPE to soft prompts improves AUC by 17.35, 16.52 and 13.08 points at 10, 30, and 60 seconds, respectively. This indicates that soft prompts and GPE are not redundant: the prompts adapt the frozen backbone to longer horizon, whereas GPE supplies explicit segment-level temporal information that strengthens adaptation across variable durations.\n\nWe will revise the interpretation of Table 3 and report the factorial results.\n\n> **L1:** *Computational cost and scalability*\n\nWe appreciate the reviewer for raising this important point and agree that a broader characterization of computational cost would help readers understand the practical trade-offs of our method. We would first like to clarify that our intended efficiency claim is specifically about **parameter-efficient adaptation**, rather than reduced wall-clock training time.\n\nAs reported in Appendix B.5, we quantify the trainable parameters of our method and full fine-tuning across all four backbones. These counts include all newly introduced trainable components, including the soft prompts, global positional embeddings, projection heads, and classifier. We apologize that this analysis was not sufficiently prominent and will add a clearer reference to Appendix B.5 in the main text.\n\nWe further report cumulative storage across four tasks, normalized by one CSFM-Base backbone. “Scope” indicates the tuned components, and “Extra modules” denotes the presence of additional modules.\n\n|CSFM-Base (157.39M)||Total params|Scope: Input|Scope: Backbone|Scope: Task head|Extra modules|\n|---|---|---|---|---|---|---|\n|**Total # of tasks**|**4**||||||\n|(a)|Full Fine-tuning|4.00×||✓|✓||\n|(b)|Linear Probing|1.00×|||✓||\n||Partial Tuning|1.21×||✓|✓||\n||Bias Tuning|1.01×||✓|✓||\n|(c)|Adapter|1.06×||✓|✓|✓|\n||VPT|1.09×|✓||✓||\n||**Ours**|**1.11×**|✓||✓|✓|\n\nWe nevertheless agree that trainable parameter count does not provide a complete characterization of computational cost. Although improving training speed is not a primary claim of this work, the frozen teacher and auxiliary consistency objectives introduce additional computation during adaptation. Importantly, the teacher and auxiliary loss computation are not required at inference. We will revise the manuscript to more clearly distinguish **parameter efficiency** from training time efficiency, and avoid implying faster training."+ },+ "createdAt": "2026-07-29T16:18:22.689Z",+ "modifiedAt": "2026-11-19T16:50:48.971Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=wlsAS5gSso",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/yiqltxfi6u.json added
+++ b/reviews/openreview/kk9jn1duey/notes/yiqltxfi6u.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "YiqLTXFi6u",+ "replyTo": "Tosob0JMTC",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "> **Q3:** *Full fine-tuning protocol*\n\nWe thank the reviewer for identifying an ambiguity in the description of the full fine-tuning baseline. In the submitted experiments, **Full Fine-tuning** directly adapts the pretrained model on 180-second recordings: the pretrained positional embeddings are extended through interpolation, and all model parameters are updated. It is then evaluated at different input durations. This baseline tests whether a short-horizon foundation model can be converted into a long-context model through conventional end-to-end fine-tuning.\n\nThe reviewer's proposed protocol addresses a different and complementary strategy: fine-tuning the backbone on 10-second windows, independently predicting each window of a long recording, and aggregating the window-level predictions. We agree that this is an informative control and denote it as **10-second fine-tuning + logit pooling**. We add this baseline using the same patient-level splits and preprocessing on VTaC. Full results will be release in the final version. \n\n\n| Backbone | Protocol | VTaC Mean [95% CI] | \n| :-------- | :--------------- | ----------------: | \n| CSFM-Tiny | 10 s Fine-tuning + Logit Pooling | 70.91 [64.44, 77.61]| \n| CSFM-Tiny | Full Fine-tuning | 81.31 [75.36, 86.93] | \n| CSFM-Tiny | Frozen backbone + Logit Pooling | 70.24 [55.48, 75.09] | \n| CSFM-Tiny | **Ours** | **87.58 [82.82, 91.37]** |\n| CSFM-Base | 10 s Fine-tuning + Logit Pooling | 74.22 [65.70, 78.97] | \n| CSFM-Base | Full Fine-tuning | 82.66 [75.11, 89.63] | \n| CSFM-Base | Frozen backbone + Logit Pooling | 73.92 [61.48, 79.68] |\n| CSFM-Base | **Ours** | **91.95 [88.08, 95.53]** |\n| ECG-JEPA | 10 s Fine-tuning + Logit Pooling | 77.91 [71.83, 83.42] | \n| ECG-JEPA | Full Fine-tuning | 88.68 [84.05, 92.79] | \n| ECG-JEPA | Frozen backbone + Logit Pooling | 74.12 [64.07, 78.10] | \n| ECG-JEPA | **Ours** | **90.83 [86.21, 95.03]** |\n| MERL | 10 s Fine-tuning + Logit Pooling | 75.46 [69.63, 81.61] | \n| MERL | Full Fine-tuning | 87.46 [82.24, 92.23] | \n| MERL | Frozen backbone + Logit Pooling | 71.39 [67.21, 72.32] |\n| MERL | **Ours** | **81.23 [77.79, 87.74]** | \n\n\nAll entries above correspond to the 180-second evaluation. On VTaC, fine-tuning the 10-second model before logit pooling consistently improves over frozen logit pooling, but remains below direct 180-second fine-tuning across all four backbones. \n\n> **L1:** *Computational overhead and parameter efficiency*\n\nThis is a very helpful point. Our intended claim is specifically **parameter-efficient adaptation**, rather than faster wall-clock training. We will revise the manuscript accordingly to make this distinction more clear.\n\nAppendix B.5 already reports the trainable parameter counts of our method and full fine-tuning across all four backbones. Importantly, our counts include every newly introduced trainable component: the soft prompts, global positional embeddings, projection heads, and classifier. We will make this analysis more prominent in the main text.\n\nTo make the practical storage trade-off clearer, we additionally report the cumulative parameters required for four downstream tasks, normalized by the size of one CSFM-Base backbone. “Scope” indicates where tuning occurs, and “Extra modules” indicates modules beyond the pretrained backbone and standard task head.\n\n|CSFM-Base (157.39M)||Total params|Scope: Input|Scope: Backbone|Scope: Task head|Extra modules|\n|---|---|---|---|---|---|---|\n|**Total # of tasks**|**4**||||||\n|(a)|Full Fine-tuning|4.00×||✓|✓||\n|(b)|Linear Probing|1.00×|||✓||\n||Partial Tuning|1.21×||✓|✓||\n||Bias Tuning|1.01×||✓|✓||\n|(c)|Adapter|1.06×||✓|✓|✓|\n||VPT|1.09×|✓||✓||\n|**(ours)**|**Ours**|**1.11×**|✓||✓|✓|"+ },+ "createdAt": "2026-07-29T16:22:20.594Z",+ "modifiedAt": "2026-11-19T16:50:48.745Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=YiqLTXFi6u",+ "license": "CC-BY-4.0"+}