Extending Pretrained 10-Second ECG Foundation Models to Longer Horizons
Import NeurIPS 2026 submission kk9jN1duEy: 5 notes
@openreview[bot] · 2026-11-22 17:59 UTC · 645a0e32468a
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,33 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "kk9jN1duEy"+ }+ ],+ "title": "Extending Pretrained 10-Second ECG Foundation Models to Longer Horizons",+ "authors": [+ "Wei Tang",+ "Jinpei Han",+ "Kangning Cui",+ "Mattia Carletti",+ "Fredrik K. Gustafsson",+ "Shreyank N Gowda",+ "Patitapaban Palo",+ "Anshul Thakur",+ "Lei Clifton",+ "Jean-michel Morel",+ "Raymond H. Chan",+ "David A. Clifton",+ "Xiao Gu"+ ],+ "abstract": "Electrocardiogram (ECG) foundation models pretrained on typical diagnostic 10-second ECG segments, have demonstrated strong transferability across a range of clinical applications. However, many real-world applications produce recordings that are typically longer, and are varied in duration during inference time. These 10-second models have no built-in way to combine information across time. Extending them to longer horizons introduces two challenges: _structural_ incompatibilities arising from input-length disparities, and _semantic_ challenges that limit meaningful temporal aggregation. We propose a parameter-efficient framework that extends pretrained ECG foundation models to longer and variable-length ECGs without retraining the backbone. Guided by a frozen pretrained 10-second model, we introduce a lightweight plug-in module that extends the model in two complementary ways: (i) structurally compatible long-sequence processing and (ii) semantically informed temporal modeling. Experiments on multiple long-horizon ECG tasks, datasets, and foundation model backbones demonstrate that our method enables robust long-horizon extension from pretrained snapshot models, consistently outperforming sliding-window and pooling-based baselines with strong parameter efficiency.",+ "year": 2026,+ "venue": "NeurIPS 2026",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/kk9jn1duey/forms.json added
+++ b/reviews/openreview/kk9jn1duey/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/9vanvgkisx.json added
+++ b/reviews/openreview/kk9jn1duey/notes/9vanvgkisx.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "9vAnvgKiSX",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "This paper *Needs Clarification during Response Period*. It proposes a parameter-efficient framework for adapting frozen 10-second ECG foundation models to 1–5 minute recordings using hierarchical positional encoding, soft prompts, locality-aware contrastive learning, and dynamics-aware consistency. Reviewers 51AV and UWoS find the problem practical, the evaluation comprehensive, and the gains consistent across several ECG backbones, tasks, and recording durations.\n\nThe main concern is whether the evaluated 180-second setting establishes a clinically meaningful long-horizon problem. Reviewer 51AV notes that VTaC performance saturates beyond 60 seconds, while Reviewer UWoS cautions that 1–5 minutes is still far from 24–48 hour Holter monitoring. Reviewer HjLT also asks for wearable single-lead ECG evaluation, where longer monitoring is more natural than for standard 12-lead ECGs.\n\nThe empirical case would also benefit from stronger controls. The improvements are moderate, with no seed-level variance, CIs, or significance tests. Reviewer HjLT questions whether the full fine-tuning baseline is implemented fairly and notes that stronger ECG FMs, such as ECGFounder, D-BETA, and MELP, are absent. The effects of soft prompts and global positional encoding are not separated, while the gains appear to come mainly from the locality-aware loss.\n\nFinally, the claimed variable-length and parameter-efficient properties are not fully evaluated. The method uses fixed non-overlapping 10-second segments and a finite learned positional table, with no tests on unseen lengths, overlapping windows, or segment-boundary events. FLOPs, GPU memory, training time, inference latency, and parameter overhead are also missing.\n\nThe rebuttal should prioritize addressing the following concerns raised by reviewers:\n1. Results at 30, 60, 120, and 180 seconds on all tasks, compared with at least one snapshot and one fine-tuning baseline.\n2. Report Mean +- SD and paired tests or CIs for the main comparisons.\n3. Full details and verification of the fine-tuning baselines, especially how 10-second FMs are adapted and aggregated at test time.\n4. Separate ablations for soft prompts, global positional encoding, locality-aware loss, and dynamics-aware loss.\n5. Tests on unseen sequence lengths and overlapping windows, including events crossing 10-second segment boundaries.\n6. Parameter count, FLOPs, GPU memory, training time, and inference latency as sequence length increases.\n7. A wearable single-lead ECG experiment or a narrower framing of the clinical long-horizon claims.",+ "final_justification": "The author response addressed the main concerns from the initial reviews. Reviewer HjLT increased the rating after the added experiments on architecture/teacher generality, the full fine-tuning protocol, statistical uncertainty, and additional ablations. Reviewers also found that concerns about metric reporting, computational cost, and uncertainty quantification were substantially addressed.\n\nThe main remaining limitation is that the claimed parameter efficiency is not supported by a direct computation-overhead analysis. Overall, however, the response resolves the salient technical and evaluation concerns sufficiently."+ },+ "createdAt": "2026-09-24T11:22:53.255Z",+ "modifiedAt": "2026-11-18T14:56:27.116Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=9vAnvgKiSX",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/n5pzykwlpy.json added
+++ b/reviews/openreview/kk9jn1duey/notes/n5pzykwlpy.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "N5pzYkWlpy",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair 8QNf",+ "content": {+ "metareview": "This paper *Needs Clarification during Response Period*. It proposes a parameter-efficient framework for adapting frozen 10-second ECG foundation models to 1–5 minute recordings using hierarchical positional encoding, soft prompts, locality-aware contrastive learning, and dynamics-aware consistency. Reviewers 51AV and UWoS find the problem practical, the evaluation comprehensive, and the gains consistent across several ECG backbones, tasks, and recording durations.\n\nThe main concern is whether the evaluated 180-second setting establishes a clinically meaningful long-horizon problem. Reviewer 51AV notes that VTaC performance saturates beyond 60 seconds, while Reviewer UWoS cautions that 1–5 minutes is still far from 24–48 hour Holter monitoring. Reviewer HjLT also asks for wearable single-lead ECG evaluation, where longer monitoring is more natural than for standard 12-lead ECGs.\n\nThe empirical case would also benefit from stronger controls. The improvements are moderate, with no seed-level variance, CIs, or significance tests. Reviewer HjLT questions whether the full fine-tuning baseline is implemented fairly and notes that stronger ECG FMs, such as ECGFounder, D-BETA, and MELP, are absent. The effects of soft prompts and global positional encoding are not separated, while the gains appear to come mainly from the locality-aware loss.\n\nFinally, the claimed variable-length and parameter-efficient properties are not fully evaluated. The method uses fixed non-overlapping 10-second segments and a finite learned positional table, with no tests on unseen lengths, overlapping windows, or segment-boundary events. FLOPs, GPU memory, training time, inference latency, and parameter overhead are also missing.\n\nThe rebuttal should prioritize addressing the following concerns raised by reviewers:\n1. Results at 30, 60, 120, and 180 seconds on all tasks, compared with at least one snapshot and one fine-tuning baseline.\n2. Report Mean +- SD and paired tests or CIs for the main comparisons.\n3. Full details and verification of the fine-tuning baselines, especially how 10-second FMs are adapted and aggregated at test time.\n4. Separate ablations for soft prompts, global positional encoding, locality-aware loss, and dynamics-aware loss.\n5. Tests on unseen sequence lengths and overlapping windows, including events crossing 10-second segment boundaries.\n6. Parameter count, FLOPs, GPU memory, training time, and inference latency as sequence length increases.\n7. A wearable single-lead ECG experiment or a narrower framing of the clinical long-horizon claims."+ },+ "createdAt": "2026-07-18T11:38:52.747Z",+ "modifiedAt": "2026-11-18T15:22:46.613Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=N5pzYkWlpy",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/ndgyz1sts1.json added
+++ b/reviews/openreview/kk9jn1duey/notes/ndgyz1sts1.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "NdGYZ1sTs1",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer UWoS",+ "content": {+ "summary": "This paper investigates how pretrained ECG foundation models, originally trained on short 10-second segments, can be extended to longer ECG recordings using a hierarchical architecture. The proposed approach combines, local positional encoding from the pretrained backbone, a learnable global segment-level positional encoding, and soft prompt tuning. In addition to the classification objective, the model is trained with auxiliary objectives, including a soft contrastive loss in a teacher–student framework to preserve representations learned on 10-second segments, and a similarity-based objective intended to capture longer-range temporal dynamics across segments. The method is evaluated across multiple pretrained backbones, different downstream tasks, and varying recording durations, and is compared against several aggregation and adaptation strategies. Overall, the paper addresses a relevant problem of adapting short-context ECG foundation models to longer clinical recordings.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "**Strengths**\n- The idea of extending pretrained 10-second ECG foundation models to longer temporal horizons is practical and relevant, especially given the availability of such pretrained models.\n- The use of multiple pretrained backbones (e.g., CSFM, MERL, ECG-JEPA) strengthens the empirical validity and suggests the method is not tied to a single architecture.\n- The evaluation is comprehensive, including multiple recording durations, downstream tasks and adaptation strategies\n- The hierarchical design (local + global positional encoding) is a reasonable way to introduce coarse-grained temporal structure into pretrained short-window models.\n\n**Weaknesses**\n- The notion of \"long recordings\" is limited to 1–5 minutes, which is still far from true long-term ECG monitoring (e.g., Holter recordings over 24-48 hours). As such, claims regarding \"long-term\" learning or modeling should be avoided. Long term monitoring usually involves event-driven predictions rather than single-label classification.\n- Computational constraints appear to have limited experimental rigor (e.g., absence of statistical significance testing or confidence intervals), which weakens the strength of the reported comparisons.\n- While the method claims to support variable-length inputs, it is fundamentally built on fixed 10-second segmentation with its learned finite embedding table (\"global positional encoding\"), and generalization to unseen sequence lengths (e.g., longer segment indices, overlapping windows, or even <10s cases) is not evaluated.\n- The use of AUC as the only evaluation metric limits insight into clinically relevant performance, particularly under class imbalance where sensitivity, specificity, and PR-AUC would be more informative.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "- Why did computational complexity prevent standard statistical evaluation (e.g., confidence intervals/bootstrapping or cross-validation)?\n- Was any ablation performed to disentangle the effects of soft prompts vs global positional encoding or their interaction? If not, how should their individual contributions be interpreted?",+ "limitations": "- No evaluation of computational cost (e.g., training and inference time, scaling behavior with sequence length, or parameter overhead introduced by prompts and global positional encodings), which limits understanding of efficiency and scalability.\n- Limited discussion of variable-length sequence handling. The method appears not to explicitly address this, and a brief discussion or positioning as future work would improve clarity.\n- No statistical significance analysis or cross-validation",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "Nothing to report",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The authors addressed my concerns about metric reporting, computational cost, uncertainty quantification and provided aditional ablations."+ },+ "createdAt": "2026-06-24T19:36:54.935Z",+ "modifiedAt": "2026-11-18T13:41:20.225Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=NdGYZ1sTs1",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/oxhuwgzpp3.json added
+++ b/reviews/openreview/kk9jn1duey/notes/oxhuwgzpp3.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "oXhUWgZPp3",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer 51AV",+ "content": {+ "summary": "The authors propose a framework for extending short horizon trained ECG Foundation Models (FM) to longer time horizons (180 sec) without necessarily retraining entire networks from scratch. Their paper works with the idea that short horizon models already encode relative local representations and can be reapplied over a longer horizon window. The authors use a combination of locality and dynamic consistency objectives to do so and demonstrate the efficacy of their proposed method on multiple FM backbone and on 3 long horizon ECG Tasks against a number of other baseline adaptation methods.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "1. The work is well motivated with convincing results regarding the effect of their long horizon adaptation methods on multiple fronts. The authors demonstrate that their proposed method is noticeably better across multiple ECG tasks against existing Snapshot Aggregation and Fine-tuning based methods. They are also able to demonstrate this across signal modalities as seen in Figure 4.\n2. Additionally, their ablations demonstrate that the combination of the proposed consistency losses are better than either of them individually. However, it must be noted that a large portion of their improvement seems to be derived from the locality-aware consistency loss.",+ "quality": 3,+ "clarity": 4,+ "significance": 3,+ "originality": 3,+ "questions": "1. Can the authors comment on the clinical necessity of the 180 second long time horizon itself on VTaC, MC-MED and CPSC2021 tasks and whether it diverges from the need for a similar window in the proposed method? Table A2 for example, demonstrates that the performance of a longer time horizon on VTaC saturates beyond 60 seconds. It would be interesting to see how the proposed method and 1 other method from Snapshot aggregation and Fine-tuning based aggregation respond to shorter time windows on all tasks. And how would the other methods other than CSFM-Tiny behave under the same settings? \n2. The proposed method relies on teacher-student consistency losses. Could the authors comment on any challenges encountered during training and optimization? Although this differs from online teacher-student based self-distillation methods such as DINO or BYOL, it would be useful to understand whether the proposed consistency objectives introduce any sensitivity to optimization or loss weighting.",+ "limitations": "Yes",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The authors already had an interesting manuscript and have provided a detailed rebuttal to my questions."+ },+ "createdAt": "2026-06-26T11:48:04.704Z",+ "modifiedAt": "2026-11-18T13:41:18.771Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=oXhUWgZPp3",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/notes/y6ljmtg1jv.json added
+++ b/reviews/openreview/kk9jn1duey/notes/y6ljmtg1jv.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "y6lJMTG1JV",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer HjLT",+ "content": {+ "summary": "The paper proposes a parameter-efficient framework to adapt frozen 10s ECG foundation models to longer and variable-length recordings, combining a hierarchical positional encoding scheme, soft prompt tuning, a locality-aware soft contrastive objective, and a dynamics-aware consistency loss guided by teacher-derived affinity.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths \n\n- The motivation for extending 10-second ECG foundation models to long-horizon settings is clinically important. \n\nWeaknesses \n\n- Computational overhead is not reported\n\n- Moderate performance improvement",+ "quality": 2,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "1. The paper demonstrates that long-horizon adaptation is technically feasible, but does not fully establish that the evaluated settings correspond to the scenarios where long-horizon ECG modeling is clinically necessary. Please discuss downstream tasks that need long term monitoring. Also, the paper also benefit from testing wearable single lead ECG FMs (support long-term monitoring essensially more), instead of just 12-lead ECG FM (12 lead ECG with only 10s is very common and standard already in clinical setting, that doctors read daily). \n\n2. The proposed framework is evaluated exclusively on transformer-based ECG foundation models, and several of its key components, including hierarchical positional encoding and prompt tuning, are inherently tied to transformer architectures. Furthemore, the effectiveness of the semantic extension appears dependent on the quality of the teacher backbone, limiting the generality of the proposed approach. The authors should evaluate and discuss it. \n\n3. It remains unclear how experiments with finetuning baselines are conducted. It would be not persuadable if: the work finetunes 10s-ECG FMs, using 180s windows. The right thing to do I think is: finetuning 10s-ECG FMs on 10s windows, then, test those finetuned models with 180s by spliting to 10s and do some aggregation/ensemble for final results. (I really question this since I am quite surprised when the results of Full Fine-tuning is quite low in Table 1).",+ "limitations": "1. Computational overhead, parameter counts, FLOPs, GPU memory usage, training time, or inference latency,… are not reported despite repeated claims of parameter efficiency. \n\n2. Several reported improvements are relatively modest, yet no seed-level variance estimates or statistical significance analyses are provided. Also, the gains may be even smaller when testing stronger ECG FMs such as ECGFounder, D-BETA, MELP. \n\n3. The relationship between the proposed consistency objective and existing stop-gradient representation learning methods is not sufficiently discussed. \n\n4. The work relies on non-overlapping 10-second segmentation. Since clinically important events may occur near segment boundaries, the impact of stride choice deserves discussion.",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The additional experiment on (1) Generality across Architectures and Teacher Backbones, (2) Full fine-tuning protocol, and (3) Statistical uncertainty resolve my previous concerns. However, the claimed parameter efficiency is not backed up with computation overhead measurement. Therefore I increased the rating from borderline reject to borderline accept."+ },+ "createdAt": "2026-06-15T18:26:01.922Z",+ "modifiedAt": "2026-11-18T13:41:21.724Z",+ "url": "https://openreview.net/forum?id=kk9jN1duEy¬eId=y6lJMTG1JV",+ "license": "CC-BY-4.0"+}
reviews/openreview/kk9jn1duey/submission.json added
+++ b/reviews/openreview/kk9jn1duey/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "kk9jN1duEy",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 20172,+ "url": "https://openreview.net/forum?id=kk9jN1duEy",+ "license": "CC-BY-4.0"+}
versions/v_qxbvxmzu.json added
+++ b/versions/v_qxbvxmzu.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-04",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 20172,+ "url": "https://openreview.net/forum?id=kk9jN1duEy",+ "reviews": "openreview/kk9jn1duey",+ "evidence": [+ "https://openreview.net/forum?id=kk9jN1duEy"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=kk9jN1duEy",+ "evidence": [+ "https://openreview.net/forum?id=kk9jN1duEy"+ ]+}