Import NeurIPS 2026 submission pP7kJXjPeY: 6 notes
@openreview[bot] · 2026-11-22 17:59 UTC · 2c7f89b5523c ·
reviews/openreview/pp7kjxjpey/forms.json added
+++ b/reviews/openreview/pp7kjxjpey/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/pp7kjxjpey/notes/3bwffjcgz2.json added
+++ b/reviews/openreview/pp7kjxjpey/notes/3bwffjcgz2.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "3bWFFjcGZ2",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer RqSw",+ "content": {+ "summary": "Unconditional histopathology image generation remains difficult because existing models like ZoomLDM and PixCell suffer from conditioning collapse, where the generative process degenerates when no class or tissue label is provided. We trace this failure to the geometry of pathology vision foundation model patch-token features, which cluster tightly on a unit hypersphere with strong angular structure and measurable intrinsic curvature. Euclidean flow matching ignores this geometry, producing suboptimal transport paths and degraded sample quality.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "**Strengths**\n\n1. The identification of conditioning collapse in existing histopathology generative models is well-motivated and supported by concrete quantitative diagnostics, including entropy decomposition via Vendi Score and SPEC-diff. The empirical characterization of VFM feature geometry—angular dominance and manifold curvature—provides a principled justification for the Riemannian formulation rather than a post-hoc rationalization.\n\n2. The bridge-type stochastic perturbation is theoretically grounded. The paper establishes per-token rectifiability on the unit hypersphere, and the vanishing-endpoint property of the sinusoidal noise schedule is well-reasoned. The connection drawn to the Karhunen–Loève expansion of the Brownian bridge lends additional theoretical coherence to the construction.\n\n3. The anisotropic decoder design is novel and mechanistically interpretable. Coupling the decoder's directional robustness budget to the singular value decomposition of the velocity-field Jacobian is a principled choice, and the superadditive interaction between this component and the stochastic bridge is explicitly verified in the ablation study.\n\n4. The two-stage ablation cleanly isolates the contribution of each component. The directional Lipschitz contrast and the encoder-dependence study further strengthen the mechanistic claims, providing evidence that the observed gains are not attributable to architectural confounds.\n\n5. The evaluation protocol is comprehensive, covering both standard metrics computed with ImageNet-pretrained models and pathology-aware variants computed with a histopathology foundation model. The inclusion of foundation-model-based evaluation is particularly valuable, as it accounts for the domain gap between natural and histopathological images that standard FID-based metrics are ill-equipped to capture.\n\n\n**Weaknesses**\n\n1. The paper lacks a downstream evaluation of the generated images as a data augmentation tool, for instance, using synthetic patches to improve performance on a pathology classification task. This experiment is particularly important given that the authors explicitly claim one primary motivation is to supply training data for foundation models. For an unconditional generative model, the most direct demonstration of practical value is whether synthetic data improves a downstream task under constrained conditions, such as a low-data regime. Without such evidence, the practical utility of STREAM beyond the generative metrics in Table 3 remains unsubstantiated.\n\n2. The paper omits direct numerical comparison with PathDiff[1], DINO-SAE, and Geometry-Aware FM. However, if PathDiff is a conditional model that similarly cannot perform unconditional generation—analogous to the limitation exposed for PixCell in Section 5.2—the authors should state this explicitly, as it would directly reinforce STREAM's core motivation. Noting such structural incompatibilities in the related work discussion would strengthen the paper's positioning without requiring numerical results.\n\n3. Two core hyperparameters—the maximum noise level and the energy threshold—receive no ablation. For the latter, the value 0.90 is reported in Appendix E without any sensitivity analysis. If these values are inherited from prior work, this should be stated explicitly. If they are new choices introduced by this paper, at least two or three alternative values should be ablated, as both parameters directly govern the geometry of the training objective.\n\n4. The paper evaluates only UNI as the primary pathology encoder, with DINOv2-L serving as a natural-image-domain negative control. However, the paper's core geometric argument—that L2-normalized patch-token features concentrate on the unit hypersphere with strong angular dominance and intrinsic curvature—applies equally to Virchow2 and Prov-GigaPath. Without at least one additional pathology-domain encoder ablation, it is unclear whether the observed gains are specific to UNI's pretraining or generalise across this model family. The authors should include results for at least one alternative pathology foundation model, or provide a systematic justification for why UNI is the preferred choice.\n\n5. The paper's discussion of practical application scenarios is insufficient. The authors identify two use cases—cross-institutional data sharing and training data for foundation models—but neither is developed to a level that substantiates the claim. For the former: how would unannotated, unconditionally generated patches be used in downstream research or clinical workflows after cross-institutional transfer? For the latter: is there a lightweight downstream task, such as a small-scale classifier, that can serve as a concrete proxy for the claimed benefit to foundation model training? The authors should expand on these scenarios in the main text or supplementary material. The practical motivation currently reads as aspirational, and even a preliminary demonstration of this kind would considerably strengthen the paper's overall case.\n\n[1] Bhosale, Mahesh, et al. \"Pathdiff: Histopathology image synthesis with unpaired text and mask conditions.\" Proceedings of the IEEE/CVF International Conference on Computer Vision. 2025.",+ "quality": 3,+ "clarity": 4,+ "significance": 3,+ "originality": 3,+ "questions": "see \"Strengths And Weaknesses\"",+ "limitations": "yes",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "N/A",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "Thank you for the authors' response. After reviewing the authors' replies across all sections, I believe all my concerns have been resolved. I strongly recommend that the authors dedicate a specific paragraph in the main text to elaborate in detail on the practical/business applications of unconditional pathology image generation. This would greatly enhance the value of this paper, and is particularly crucial for the emerging field of unconditional pathology image generation. I am raising my score to Accept."+ },+ "createdAt": "2026-06-26T16:24:26.088Z",+ "modifiedAt": "2026-11-18T13:42:00.812Z",+ "url": "https://openreview.net/forum?id=pP7kJXjPeY¬eId=3bWFFjcGZ2",+ "license": "CC-BY-4.0"+}
reviews/openreview/pp7kjxjpey/notes/gpfwpl0jwr.json added
+++ b/reviews/openreview/pp7kjxjpey/notes/gpfwpl0jwr.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "gpFWPL0JWR",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer H8PA",+ "content": {+ "summary": "This paper proposes STEAM, a Riemannian flow matching framework designed for the unconditional generation of histopathology images directly within the latent space of vision foundation models. They argued that existing diffusion models experience conditioning collapse and lack semantic structure due to VAE latents. They use VFM features to solve the issue, which encode rich and class-discriminative information within the angular structure of a hypersphere ($S^{d-1}$). To handle the high curvature and disconnected structure of VFM manifolds, STREAM uses a stochastic bridge Riemannian Flow Matching framework with a Brownian bridge perturbation. To bypass the usual reconstruction-generation tradeoff when decoding high-dimensional features, the authors design a spectral-informed anisotropic decoder. This component optimizes noise robustness using SVD of the diffusion Transformer's velocity-field Jacobian. The method is evaluated on TCGA-BRCA and TCGA-COADREAD, showing state-of-the-art generation (gFID) and reconstruction (rFID) metrics compared to existing pathology and natural-image baselines.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Quality: \n(1) strengths: The empirical evaluation is good across distribution-matching metrics. The ablation study shows the super-additive effects of pairing the stochastic bridge with the anisotropic decoder. Using velocity field Jacobian is logical. (2) weakness: The theory contains gaps. Theorem 3 analyses a single $S^{d-1}$ hypersphere, whereas the actual model operates on a product manifold $(S^{d-1})^{256}$. The authors admit that bounding the transport requires an unverified $C^2$ cross-token regularity assumption. The main results lack statistical significance testing, which weakens the reliability of the performance margins.\n\nClarity:\n(1) strength: The motivation for moving from Euclidean to Riemannian flow matching is clearly articulated and backed by empirical evidence. (2) weakness: The exact meaning of image quality is not clear from a clinical standpoint. While the mathematical framing is good, the biological relevance of the generated images is not clearly verified. The authors rely solely on automated metrics and a visual inspection of a few selected image patches. \n\nSignificance:\n(1) strength: Generative modelling directly within VFM latent spaces bypasses the need for traditional VAEs. By solving the inherent reconstruction-generation tradeoff in this domain, this work provides a contribution that could meaningfully influence future medical generative architectures. (2) weakness: The clinical utility of the method remains unproven. A generated histopathology patch that satisfies an Inception network (or a vision foundation model like Virchow2) does not guarantee true biological fidelity, nor does it ensure usefulness for downstream clinical tasks, such as training diagnostic classifiers. \n\nOriginality:\n(1) strength: The combination of stochastic bridge perturbations with an SVD-guided anisotropic decoder is a novel approach to stabilizing diffusion/flow-matching in highly sensitive manifold spaces.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "(1) How strictly does the independence assumption in Theorem 3 limit the practical guarantees on the product manifold $(S^{d-1})^{256}$? Could you provide empirical estimates or at least a bounding approximation of the $C^2$ cross-token velocity regularity. This would bridge the gap between your per-token theory and product-manifold deployment (2) FID, KID, and LPIPS measure distribution matching and perceptual similarity, but they do not guarantee biological consistency. Have you tested the utility of STREAM-generated images in downstream tasks (e.g., training a classifier for benign vs. malignant on synthetic data and testing on real data)? (3) It seems that STREAM's anisotropic decoder advantage is largely erased when using an out-of-domain encoder (DINOv2-L). Does this imply STREAM is reliant on the domain-specific properties of the UNI encoder? If a user wishes to apply STREAM to a different medical modality (e.g., radiology) where a perfect VFM does not exist, will the method fail? (4) Establishing statistical significance is critical given the varying margins between STREAM and the baselines. Could you please provide variance/error bars for the FID metrics across multiple random seeds for at least a subset of models, please?",+ "limitations": "While the authors have acknowledged the theoretical limitations of their work, they have not adequately addressed the limitations regarding clinical applicability. Generating visually realistic 256X256 tissue patches does not guarantee that the cellular structure maintain true physiological relationships or that they are free of biological hallucinations. It would need further validation.",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No major formatting or anonymity violations are observed.",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "The rebuttal strengthens the empirical case, but much of the new evidence was added late and could not be independently assessed. Key limitations remain. the product-manifold transport result is only empirically supported, the method depends on a strong domain-matched VFM, and biological fidelity lacks blinded pathologist validation. These issues lead me to a more cautious assessment."+ },+ "createdAt": "2026-06-24T10:29:23.279Z",+ "modifiedAt": "2026-11-18T13:42:04.015Z",+ "url": "https://openreview.net/forum?id=pP7kJXjPeY¬eId=gpFWPL0JWR",+ "license": "CC-BY-4.0"+}
reviews/openreview/pp7kjxjpey/notes/iirbtyn1ps.json added
+++ b/reviews/openreview/pp7kjxjpey/notes/iirbtyn1ps.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "IirBTYN1Ps",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer Ts11",+ "content": {+ "summary": "This paper introduces STREAM, a generative modeling framework that applies Riemannian Flow Matching (RFM) to the $L^2$-normalized latent space of a pretrained Vision Foundation Model (VFM). To address the disconnected-support issues of deterministic spherical flows, the authors propose a stochastic bridge interpolation. Furthermore, the decoder is regularized via an anisotropic noise injection strategy scaled by the singular value decomposition (SVD) of the generator's velocity-field Jacobian.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths:\n1. Replacing the deterministic SLERP conditional path with a stochastic bridge (Theorem 3) is a mathematically sound resolution to the disconnected-support obstruction in standard Riemannian flow matching.\n2. Coupling the decoder's robustness budget to the specific velocity-field sensitivities of the DiT via SVD is a structurally rigorous approach to managing the reconstruction-generation trade-off.\n\nWeaknesses:\n\n1. For a flow matching paper, the absence of computational complexity metrics is unacceptable. The authors state a 25-step midpoint Euler solver is used, but provide zero analysis on Number of Function Evaluations (NFE) vs. generation quality. There is no proof that their velocity field yields straighter paths or faster sampling than standard diffusion baselines.\n2. The model is evaluated purely on perceptual and distributional metrics (FID, LPIPS). Generating visually convincing tissue patches is insufficient for computational pathology if the synthetic data cannot be proven to retain diagnostic fidelity (e.g., via training downstream classifiers or segmentation models).\n3. The authors claim a \"novel anisotropic decoder.\" The architecture is a standard ViT-XL; the novelty resides entirely in the noise covariance injected during the training phase. Furthermore, the core methodology is domain-agnostic; its pathology specificity relies entirely on plugging in external models (UNI embeddings and a Kaiko discriminator).\n4. The pipeline relies on a highly specialized Kaiko ViT-S/8 discriminator. The authors fail to ablate this module against a standard, domain-agnostic PatchGAN. It is unclear if the improved reconstruction fidelity stems from the anisotropic noise or simply the use of a powerful, domain-matched adversarial prior.",+ "quality": 2,+ "clarity": 3,+ "significance": 2,+ "originality": 3,+ "questions": "1. What are the exact wall-clock inference times and total FLOPS for the generation pipeline? Please provide an NFE vs. performance (FID) trade-off curve comparing STREAM to the baselines.\n2. How does the framework perform on a quantitative downstream clinical task? (e.g., replacing real data with STREAM-generated data to train a basic tissue classifier).\n3. How does the pipeline perform if the domain-specific Kaiko discriminator is replaced with a standard PatchGAN?\n4. Why categorize the decoder as architecturally \"novel\" when only the noise injection protocol differs from standard ViT decoders?",+ "limitations": "No. \nThe authors do not discuss the practical computational limitations, NFE latency costs, and the lack of downstream diagnostic validation for their generated images.",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "None",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "Looking at the other reviews, discussions, and new results, my concerns are mostly resolved. What helped me raise my score was specifically the addition of downstream validation (nuclear morphometry, SSL pretraining, HEST probe), which was lacking in the original submission. The Virchow2 numbers also confirmed that the anisotropic decoder's benefit is not just a UNI artifact. Although I am increasing my rating, it is noteworthy to state that the Virchow2 result is limited to one dataset (BRCA) at a reduced budget (with an acknowledged backbone-size confound). That said, generalization is supported but not fully settled. Furthermore, I am scoring under the assumption that the agreed-upon corrections (dropping the low-energy claim, softening \"conditioning collapse,\" clarifying scoping) will actually appear in the camera-ready PDF.\n\nA final note for the authors:\n\n- Please ensure the terminology and scoping changes discussed here actually make it into the final revision.\n- A second dataset for the Virchow2 result would go a long way toward closing the generalizability question.\n- Ultimately, your core idea (the stochastic bridge, the SVD-coupled anisotropic decoder) is solid and remains the true contribution of the paper; the extra discussion evaluations strengthen the case, but the method itself is the main reason for acceptance."+ },+ "createdAt": "2026-06-25T08:15:23.057Z",+ "modifiedAt": "2026-11-18T13:42:02.092Z",+ "url": "https://openreview.net/forum?id=pP7kJXjPeY¬eId=IirBTYN1Ps",+ "license": "CC-BY-4.0"+}
reviews/openreview/pp7kjxjpey/notes/lkkuee4tfx.json added
+++ b/reviews/openreview/pp7kjxjpey/notes/lkkuee4tfx.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "LKkueE4TfX",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer g7J9",+ "content": {+ "summary": "This paper proposes STREAM, a stochastic Riemannian flow-matching framework for unconditional histopathology image generation. The method directly models normalized pathology foundation-model tokens on a product of hyperspheres, rather than using them only as conditioning signals. It combines a stochastic spherical bridge, which perturbs intermediate geodesic states while preserving the endpoints, with an anisotropic decoder whose noise directions are determined by the local spectral structure of the learned velocity field.\n\nThe framework is evaluated on TCGA-BRCA and TCGA-COADREAD against several recent pathology generation methods. The results indicate strong generation quality and suggest that the stochastic bridge and anisotropic decoder are most effective when used together. The use of pathology-aware metrics further strengthens the empirical evaluation.\n\nThe main concerns are theoretical and methodological. The relationship between the stochastic bridge and the training velocity is not fully derived, the practical role of the full-support result is unclear under a uniform source distribution, and the use of singular vectors in the decoder may be inconsistent with the input-space perturbation mechanism. In addition, the time dependence of the Jacobian basis, the low-energy drift assumption, the dependence on the chosen encoder, and the lack of fully controlled baselines require further clarification.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strengths\n\nThe paper is well motivated and addresses a relevant problem in unconditional histopathology image generation. Modeling normalized pathology foundation-model tokens on a product of hyperspheres is geometrically appropriate, and the stochastic spherical bridge offers an interesting extension of deterministic Riemannian flow matching by perturbing intermediate states while preserving the endpoints. The spectral-informed anisotropic decoder is also conceptually appealing because it explicitly links the local sensitivity of the generator to the robustness of the decoder. The ablation results suggest that the stochastic bridge and anisotropic decoder are complementary, and the use of pathology-specific evaluation metrics makes the experimental assessment more meaningful.\n\nWeaknesses\n\nSeveral theoretical and methodological issues remain insufficiently resolved. The definition of “conditioning collapse” is not fully justified, and the per-token theory does not directly extend to the cross-token dependencies introduced by the Transformer architecture. The connection between the stochastic bridge and the endpoint-prediction objective is not rigorously derived, while the practical significance of the full-support result is unclear when the source distribution is already uniform on the sphere. The use of left rather than right singular vectors in the decoder may be mathematically inconsistent, and the time dependence of the velocity-field Jacobian is not adequately handled. In addition, the assumption that generation errors concentrate in low-energy directions is not directly verified, the gains appear sensitive to the choice of encoder, the controlled baselines are incomplete, and the computational overhead is not reported in sufficient detail.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "Q1. Can the authors derive the exact conditional velocity associated with the stochastic spherical bridge and explain why the endpoint-prediction velocity used during inference is consistent with this path? If the relationship is only approximate, an error analysis would be helpful.\n\nQ2. Why is the full-support property considered important when the source distribution is already uniform over the sphere? Please provide a concrete example showing that deterministic SLERP can still produce problematic intermediate support under the coupling used in the paper.\n\nQ3. Does the anisotropic decoder use the left or right singular vectors of the velocity-field Jacobian? Since decoder noise is injected in the latent input space, the right singular vectors would appear to be the relevant directions. Please clarify the notation and implementation.\n\nQ4. How is the time dependence of the Jacobian handled when constructing the cached spectral basis? At which timestep, or over which set of timesteps, is the Jacobian evaluated, and how stable are the dominant subspaces across the generation trajectory?\n\nQ5. Can the authors directly verify that latent generation errors are concentrated in the low-energy spectral subspace? Reporting the projected error energy in the high- and low-energy subspaces would provide direct evidence for the proposed decoder design.\n\nQ6. Can the authors add controlled comparisons using the same UNI encoder for Euclidean flow matching, deterministic spherical flow matching, stochastic spherical flow matching, isotropic decoder regularization, and anisotropic decoder regularization? These experiments are needed to separate the effects of the encoder, geometry, bridge, and decoder.\n\nQ7. How do the per-token theoretical results extend to the full Transformer model with cross-token self-attention? Please specify which claims apply only to the probability path and which require additional smoothness or independence assumptions.\n\nQ8. How is “conditioning collapse” distinguished from desirable dependence on the conditioning signal? Additional analyses of latent utilization, condition permutation, and output diversity under a fixed condition would make this claim more convincing.\n\nQ9. How sensitive is the method to the choice of pathology encoder? Since the anisotropic decoder appears less effective with DINOv2-L, please discuss the conditions under which the proposed spectral mechanism is expected to work.\n\nQ10. What is the total computational overhead of STREAM, including DiT training, Jacobian-vector products, randomized SVD, clustering, spectral-basis caching, and decoder training? Reporting GPU hours, preprocessing time, and storage requirements would improve reproducibility.",+ "limitations": "Weaknesses\n\nSeveral theoretical and methodological issues remain insufficiently resolved. The definition of “conditioning collapse” is not fully justified, and the per-token theory does not directly extend to the cross-token dependencies introduced by the Transformer architecture. The connection between the stochastic bridge and the endpoint-prediction objective is not rigorously derived, while the practical significance of the full-support result is unclear when the source distribution is already uniform on the sphere. The use of left rather than right singular vectors in the decoder may be mathematically inconsistent, and the time dependence of the velocity-field Jacobian is not adequately handled. In addition, the assumption that generation errors concentrate in low-energy directions is not directly verified, the gains appear sensitive to the choice of encoder, the controlled baselines are incomplete, and the computational overhead is not reported in sufficient detail.",+ "rating": 4,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "NA",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "After considering the authors’ detailed rebuttal and follow-up, I have increased my score. The authors have satisfactorily addressed all major concerns by clarifying the bridge as a training-time smoothing mechanism, correcting the left-singular-vector interpretation, removing the unsupported low-energy error-concentration claim, acknowledging the temporal-anchor and Euclidean-comparison limitations, moderating the conditioning terminology, narrowing the encoder-dependent claims, and adding the requested computational details and condition-permutation analysis. These revisions substantially improve the technical accuracy, transparency, and scope of the paper; the remaining issues are primarily presentational rather than fundamental. Given the methodological originality and strong empirical results."+ },+ "createdAt": "2026-06-19T01:35:14.366Z",+ "modifiedAt": "2026-11-18T13:42:05.415Z",+ "url": "https://openreview.net/forum?id=pP7kJXjPeY¬eId=LKkueE4TfX",+ "license": "CC-BY-4.0"+}
reviews/openreview/pp7kjxjpey/notes/wh0xsznmej.json added
+++ b/reviews/openreview/pp7kjxjpey/notes/wh0xsznmej.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "wH0XszNMej",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair zHQe",+ "content": {+ "metareview": "Final Meta Review\n\n\n## 1. Summary of the Contribution\n\nThe paper proposes STREAM, the first framework to apply Riemannian Flow Matching to histopathology image generation. The contribution is built around two coupled mechanisms:\n\n1. a stochastic bridge-like perturbation that establishes a token-wise rectifiability property on the hypersphere $\\mathcal{S}^{d-1}$ for training a latent-space DiT (Theorem 3);\n2. an anisotropic decoder whose noise covariance matrix is shaped by the singular value decomposition of the Jacobian of the velocity field of the trained DiT—low noise along high-energy directions (preserving fidelity) and high noise along low-energy directions (absorbing the generator’s residual drift).\n\nThe authors report a superadditive effect from combining the two mechanisms, achieving state-of-the-art performance on TCGA-BRCA and competitive performance on TCGA-COADREAD.\n\n## 2. Overall Assessment After the Discussion\n\nThe discussion period convincingly addressed several concerns raised during the initial review, particularly regarding the generality of the method beyond a single encoder. This development warrants an upward revision of the assessment of several aspects of the work, as detailed in Section 3. \n\n## 3. Strengths Confirmed by the Discussion Period\n\nThe single decisive weakness identified in the initial meta-review — absence of downstream utility validation — has been comprehensively resolved. The authors provide three independent, pixel-level downstream evaluations: (1) nuclear morphometry (HoVer-NeXt, ~2.5M nuclei) showing ≤2% deviation from real tissue on seven shape descriptors; (2) self-supervised pre-training (DINO ViT-S/16, 1M tiles/organ) where a STREAM-only encoder matches a real-data encoder on nine out-of-distribution binary tasks (SPIDER, MHIST); (3) spatial transcriptomics prediction (HEST, 50 HVGs) where STREAM embeddings achieve Pearson correlations on par with real data. This directly substantiates the paper’s stated motivation of supplying training data for foundation models.\n\nGeneralization to a second pathology encoder (resolved). The authors explicitly acknowledge that validation with a single encoder (UNI) was insufficient and provide two compelling additions: (i) a complete replication with Virchow2, showing that the gain provided by the bridge + anisotropic decoder combination over an isotropic control is maintained, and even slightly amplified, with the second encoder; and (ii) a controlled-encoder comparison (UNI for all methods, including retrained RAE, SVG, and REPA-E), extended to a third, non-TCGA dataset (SPIDER-skin, from a different organ), where STREAM consistently outperforms the alternatives. The limitations affecting absolute comparability across encoders (patch dimension, retina size, and tile resizing) are candidly acknowledged by the authors themselves, which strengthens rather than weakens the credibility of the demonstration. This issue, which could by itself have justified a rejection, is now considered adequately addressed.\n\nMethodological strengthening through additional ablations. The two additional ablations—the four-way comparison of the parameterization/loss pairing (chord vs. geodesic, endpoint vs. velocity prediction) and the comparison of noise-schedule shapes (one- or two-mode Karhunen–Loève truncation versus stochastic interpolants and variance exploding profiles)—provide empirical justification for design choices that were not supported in the initial version. The authors correctly point out that no published Riemannian flow-matching method at this dimensional scale had performed this comprehensive comparison; this constitutes a genuine methodological contribution, even though it remains secondary to the main contribution.\n\n\n## 4. Theoretical Scope Clarified (Post-Rebuttal)\n\nThe authors clarified the precise scope of Theorem 3: parts (i)–(iii) (full support, rectifiability, smooth marginal velocity) lift from a single sphere to the product manifold **(S^{d-1})^N without any cross-token assumption**. The cross-token regularity assumption is confined to **Proposition 7's transport-rate bound** (O(ϑ²_max)), not to rectifiability itself. The authors measured the actual cross-token coupling in the trained DiT at **0.21% of diagonal-block Frobenius energy** (averaged over 50 centroids × 500 probes × 9 timesteps), providing a first-order empirical proxy for the quantity the assumption controls. This distinction is now explicitly stated in the manuscript (Section 4.2) and will be further emphasized in the camera-ready revision. While a full theoretical guarantee for the product manifold remains open—as acknowledged in the limitations—the gap is now clearly delimited and empirically bounded.\n\n## 5. Experimental Rigor Completed (Post-Rebuttal)\n\n- **Statistical significance**: Multi-seed evaluation is now reported (5 seeds @10K, 3 seeds @50K for main results; 5 seeds for all four ablation cells). Margins are large multiples of seed spread (e.g., STREAM 6.53±0.03 vs. RAE 15.88±0.04 vs. SVG 17.52±0.14 on TCGA-BRCA @50K).\n- **Computational cost**: Full characterization provided — NFE vs. gFID curves at matched budgets (STREAM leads at every NFE; at NFE=26 beats baselines at NFE=50), per-image cost (12.14 TFLOPs, 94.8 ms on H200), and GPU-hours breakdown (JVP+SVD stage = 69 GPU-h, 12.6% of total pipeline; decoder training dominates at 299 GPU-h). Storage requirements also reported (~30 GB spectral cache, 5.9 TB pre-extracted features avoidable via on-the-fly extraction).\n\nAll technical gaps raised in the initial review have been addressed with new experiments or theoretical clarifications.\n\n\n## 6. Remaining Limitations (Non-Blocking, to be Addressed in Camera-Ready)\n\n- Virchow2 validated on one dataset (BRCA) at reduced budget with a backbone-size confound; **second dataset run committed for camera-ready**.\n- Full product-manifold theoretical guarantee remains open; empirical proxy (0.21% cross-token coupling) provided and scope explicitly delimited in Section 4.2 / camera-ready.\n- No blinded pathologist study; public gallery of generated images planned for release.\n- Dependence on strong domain-matched VFM is a precondition shared by all baselines (PixCell, ZoomLDM, RAE, PathDiff).\n\n## 7. Verdict\n\nSTREAM delivers a robust and original methodological advance for unconditional histopathology image generation:\n- **Geometric diagnosis** (hyperspherical concentration, intrinsic curvature) → justified Riemannian formulation.\n- **Stochastic bridge** (Theorem 3) resolves the disconnected-support obstruction of deterministic SLERP — first stochastic RFM at this scale.\n- **Spectral-informed anisotropic decoder** breaks the reconstruction/generation trade-off (demonstrated super-additivity).\n- **Comprehensive evaluation**: distributional metrics (pathology-aware), reconstruction, **three downstream pixel-level validations**, multi-encoder generality (UNI, Virchow2, Phikon-v2), controlled ablations, complexity, and statistical significance.\n\nThe critical shortcoming identified in the initial review (lack of downstream validation) has been resolved by conclusive, independent experiments. \n\n**Recommendation: Accept** (conditional on camera-ready integrating the 10 committed items detailed in the SAC comment).\n\n---\n\nArea Chair"+ },+ "createdAt": "2026-07-23T20:45:10.553Z",+ "modifiedAt": "2026-11-18T15:23:18.399Z",+ "url": "https://openreview.net/forum?id=pP7kJXjPeY¬eId=wH0XszNMej",+ "license": "CC-BY-4.0"+}
reviews/openreview/pp7kjxjpey/notes/wyf24np2jj.json added
+++ b/reviews/openreview/pp7kjxjpey/notes/wyf24np2jj.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "WyF24NP2Jj",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (spotlight)",+ "comment": "",+ "metareview": "Final Meta Review\n\n\n## 1. Summary of the Contribution\n\nThe paper proposes STREAM, the first framework to apply Riemannian Flow Matching to histopathology image generation. The contribution is built around two coupled mechanisms:\n\n1. a stochastic bridge-like perturbation that establishes a token-wise rectifiability property on the hypersphere $\\mathcal{S}^{d-1}$ for training a latent-space DiT (Theorem 3);\n2. an anisotropic decoder whose noise covariance matrix is shaped by the singular value decomposition of the Jacobian of the velocity field of the trained DiT—low noise along high-energy directions (preserving fidelity) and high noise along low-energy directions (absorbing the generator’s residual drift).\n\nThe authors report a superadditive effect from combining the two mechanisms, achieving state-of-the-art performance on TCGA-BRCA and competitive performance on TCGA-COADREAD.\n\n## 2. Overall Assessment After the Discussion\n\nThe discussion period convincingly addressed several concerns raised during the initial review, particularly regarding the generality of the method beyond a single encoder. This development warrants an upward revision of the assessment of several aspects of the work, as detailed in Section 3. \n\n## 3. Strengths Confirmed by the Discussion Period\n\nThe single decisive weakness identified in the initial meta-review — absence of downstream utility validation — has been comprehensively resolved. The authors provide three independent, pixel-level downstream evaluations: (1) nuclear morphometry (HoVer-NeXt, ~2.5M nuclei) showing ≤2% deviation from real tissue on seven shape descriptors; (2) self-supervised pre-training (DINO ViT-S/16, 1M tiles/organ) where a STREAM-only encoder matches a real-data encoder on nine out-of-distribution binary tasks (SPIDER, MHIST); (3) spatial transcriptomics prediction (HEST, 50 HVGs) where STREAM embeddings achieve Pearson correlations on par with real data. This directly substantiates the paper’s stated motivation of supplying training data for foundation models.\n\nGeneralization to a second pathology encoder (resolved). The authors explicitly acknowledge that validation with a single encoder (UNI) was insufficient and provide two compelling additions: (i) a complete replication with Virchow2, showing that the gain provided by the bridge + anisotropic decoder combination over an isotropic control is maintained, and even slightly amplified, with the second encoder; and (ii) a controlled-encoder comparison (UNI for all methods, including retrained RAE, SVG, and REPA-E), extended to a third, non-TCGA dataset (SPIDER-skin, from a different organ), where STREAM consistently outperforms the alternatives. The limitations affecting absolute comparability across encoders (patch dimension, retina size, and tile resizing) are candidly acknowledged by the authors themselves, which strengthens rather than weakens the credibility of the demonstration. This issue, which could by itself have justified a rejection, is now considered adequately addressed.\n\nMethodological strengthening through additional ablations. The two additional ablations—the four-way comparison of the parameterization/loss pairing (chord vs. geodesic, endpoint vs. velocity prediction) and the comparison of noise-schedule shapes (one- or two-mode Karhunen–Loève truncation versus stochastic interpolants and variance exploding profiles)—provide empirical justification for design choices that were not supported in the initial version. The authors correctly point out that no published Riemannian flow-matching method at this dimensional scale had performed this comprehensive comparison; this constitutes a genuine methodological contribution, even though it remains secondary to the main contribution.\n\n\n## 4. Theoretical Scope Clarified (Post-Rebuttal)\n\nThe authors clarified the precise scope of Theorem 3: parts (i)–(iii) (full support, rectifiability, smooth marginal velocity) lift from a single sphere to the product manifold **(S^{d-1})^N without any cross-token assumption**. The cross-token regularity assumption is confined to **Proposition 7's transport-rate bound** (O(ϑ²_max)), not to rectifiability itself. The authors measured the actual cross-token coupling in the trained DiT at **0.21% of diagonal-block Frobenius energy** (averaged over 50 centroids × 500 probes × 9 timesteps), providing a first-order empirical proxy for the quantity the assumption controls. This distinction is now explicitly stated in the manuscript (Section 4.2) and will be further emphasized in the camera-ready revision. While a full theoretical guarantee for the product manifold remains open—as acknowledged in the limitations—the gap is now clearly delimited and empirically bounded.\n\n## 5. Experimental Rigor Completed (Post-Rebuttal)\n\n- **Statistical significance**: Multi-seed evaluation is now reported (5 seeds @10K, 3 seeds @50K for main results; 5 seeds for all four ablation cells). Margins are large multiples of seed spread (e.g., STREAM 6.53±0.03 vs. RAE 15.88±0.04 vs. SVG 17.52±0.14 on TCGA-BRCA @50K).\n- **Computational cost**: Full characterization provided — NFE vs. gFID curves at matched budgets (STREAM leads at every NFE; at NFE=26 beats baselines at NFE=50), per-image cost (12.14 TFLOPs, 94.8 ms on H200), and GPU-hours breakdown (JVP+SVD stage = 69 GPU-h, 12.6% of total pipeline; decoder training dominates at 299 GPU-h). Storage requirements also reported (~30 GB spectral cache, 5.9 TB pre-extracted features avoidable via on-the-fly extraction).\n\nAll technical gaps raised in the initial review have been addressed with new experiments or theoretical clarifications.\n\n\n## 6. Remaining Limitations (Non-Blocking, to be Addressed in Camera-Ready)\n\n- Virchow2 validated on one dataset (BRCA) at reduced budget with a backbone-size confound; **second dataset run committed for camera-ready**.\n- Full product-manifold theoretical guarantee remains open; empirical proxy (0.21% cross-token coupling) provided and scope explicitly delimited in Section 4.2 / camera-ready.\n- No blinded pathologist study; public gallery of generated images planned for release.\n- Dependence on strong domain-matched VFM is a precondition shared by all baselines (PixCell, ZoomLDM, RAE, PathDiff).\n\n## 7. Verdict\n\nSTREAM delivers a robust and original methodological advance for unconditional histopathology image generation:\n- **Geometric diagnosis** (hyperspherical concentration, intrinsic curvature) → justified Riemannian formulation.\n- **Stochastic bridge** (Theorem 3) resolves the disconnected-support obstruction of deterministic SLERP — first stochastic RFM at this scale.\n- **Spectral-informed anisotropic decoder** breaks the reconstruction/generation trade-off (demonstrated super-additivity).\n- **Comprehensive evaluation**: distributional metrics (pathology-aware), reconstruction, **three downstream pixel-level validations**, multi-encoder generality (UNI, Virchow2, Phikon-v2), controlled ablations, complexity, and statistical significance.\n\nThe critical shortcoming identified in the initial review (lack of downstream validation) has been resolved by conclusive, independent experiments. \n\n**Recommendation: Accept** (conditional on camera-ready integrating the 10 committed items detailed in the SAC comment).\n\n---\n\nArea Chair",+ "final_justification": "The work constitutes a genuine methodological advance — geometrically principled stochastic Riemannian flow matching with a spectral anisotropic decoder that breaks the reconstruction/generation trade-off — now backed by distributional, reconstruction, and downstream utility evidence across multiple pathology encoders and datasets."+ },+ "createdAt": "2026-09-24T11:23:48.326Z",+ "modifiedAt": "2026-11-18T14:57:03.534Z",+ "url": "https://openreview.net/forum?id=pP7kJXjPeY¬eId=WyF24NP2Jj",+ "license": "CC-BY-4.0"+}
reviews/openreview/pp7kjxjpey/submission.json added
+++ b/reviews/openreview/pp7kjxjpey/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "pP7kJXjPeY",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 22412,+ "url": "https://openreview.net/forum?id=pP7kJXjPeY",+ "license": "CC-BY-4.0"+}
versions/v_whu4vy4s.json added
+++ b/versions/v_whu4vy4s.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-04",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (spotlight)",+ "number": 22412,+ "url": "https://openreview.net/forum?id=pP7kJXjPeY",+ "reviews": "openreview/pp7kjxjpey",+ "evidence": [+ "https://openreview.net/forum?id=pP7kJXjPeY"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=pP7kJXjPeY",+ "evidence": [+ "https://openreview.net/forum?id=pP7kJXjPeY"+ ]+}