Subject-Relative Micro-Motion and Sleep Dynamics for Near-Infrared Video Sleep Staging
Update NeurIPS 2026 submission 5WH6aA0LYO: 19 notes
@openreview[bot] · 2026-11-24 15:45 UTC · 8ce695e886e6 ·
reviews/openreview/5wh6aa0lyo/notes/1jwmqwsxaq.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/1jwmqwsxaq.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "1jwmqwSXAq",+ "replyTo": "gqzJaghL1S",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (3-1/3)",+ "comment": "**[W4 / Q4] Additional results: respiratory event-level analysis and AHI stratification**\n\nFollowing the reviewer's suggestion under Limitations, we extend the analysis from the whole-night level to individual respiratory events. An epoch is an event epoch if it contains a scored apnea or hypopnea. These account for 20,121 of the 57,918 test epochs, and their prevalence scales with severity as expected, from 3.9% in Normal to 58.8% in Severe.\n\n**Table R5.** Four-class performance by epoch type.\n\n| Condition | Epochs | Acc | κ | MF1 |\n| --- | --- | --- | --- | --- |\n| Event-free | 37,797 | 0.784 [0.756, 0.808] | 0.676 [0.634, 0.713] | 0.778 [0.750, 0.802] |\n| Event | 20,121 | 0.843 [0.822, 0.861] | 0.651 [0.609, 0.686] | 0.645 [0.604, 0.684] |\n\nAccuracy rises while MF1 falls, and both follow from the difference in stage composition, since event epochs are dominated by Light and MF1 weights all four stages equally. We therefore decompose per stage using recall, which is computed over the true epochs of each stage and is unaffected by that difference.\n\n**Table R6.** Per-stage recall by epoch type. Δ is event minus event-free, so negative values indicate worse recall during events. The first column gives the share of each stage's epochs that carry an event.\n\n| Stage | With an event | Event-free | Event | Δ | 95% CI on Δ |\n| --- | --- | --- | --- | --- | --- |\n| Wake | 14.6% | 0.755 | 0.574 | −0.181 | [−0.236, −0.124] |\n| Light | 46.2% | 0.818 | 0.897 | +0.079 | [+0.042, +0.124] |\n| Deep | 5.1% | 0.703 | 0.314 | −0.389 | [−0.553, −0.186] |\n| REM | 47.4% | 0.836 | 0.818 | −0.018 | [−0.088, +0.054] |\n\nThe effect is directional rather than a uniform loss. Deep recall falls while Light recall rises, the signature of Deep epochs being relabelled as Light, which is the axis that dominates our residual errors generally. A respiratory event alters thoraco-abdominal motion within the epoch, whether by reducing effort or by producing paradoxical effort followed by a recovery breath, and the errors move along that same axis. Its reach is bounded by the physiology, since respiratory events are markedly reduced in slow-wave sleep [3] and only 5.1% of Deep epochs carry one, the lowest of any stage, so the affected epochs are a small share of the night.\n\nWake recall also falls, and this speaks to the reviewer's concern about abnormal motion being read as wakefulness. If arousal-related motion were being taken for wake, the model would predict Wake more liberally during events. It does not. Wake is predicted for 4.4% of event-free sleep epochs and 5.4% of event sleep epochs. The drop is instead a boundary effect. Respiratory events are scored during sleep while an epoch is scored Wake when wake occupies most of its 30 seconds, so an epoch that is both spans a transition, and our rebuttal showed that errors concentrate near stage boundaries (Table R2 there).\n\nREM shows no detectable effect, which is consistent with how the model identifies REM in the first place. Figure 4 shows REM recall at 0.54 from the epoch-level classifier and 0.83 after SDM, so REM assignment rests substantially on full-night context rather than on each epoch's own evidence, as AASM scoring itself does when it continues REM across epochs lacking rapid eye movements [4]. A disruption confined to one epoch therefore has less to act on. The SDM lift is essentially unchanged within event epochs (0.54 to 0.82) against event-free ones (0.55 to 0.84). Deep gains far less from context (0.57 to 0.68), which is consistent with it being where events hurt most.\n\nThese are pooled comparisons, so subjects with more events contribute more to the event subset. We therefore also stratify by severity in the next comment.\n\n---\n\n[3] Ratnavadivel et al. Marked reduction in obstructive sleep apnea severity in slow wave sleep. JCSM 5(6), 2009.\n[4] Berry et al. The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications. American Academy of Sleep Medicine, 2012."+ },+ "createdAt": "2026-08-01T13:46:55.025Z",+ "modifiedAt": "2026-11-19T17:17:17.095Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=1jwmqwSXAq",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/3bcuwyaj4n.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/3bcuwyaj4n.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "3bcUWYAJ4N",+ "replyTo": "gqzJaghL1S",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (2-1/3)",+ "comment": "**[W1 / Q1] Additional results, part 2. Cross-dataset validation**\n\nPublic NIR sleep-video datasets with synchronized PSG labels are not available, so pre-training on external video remains out of reach. External validation is possible within KVSS, and we evaluated the Hospital A model on Hospitals B and C in three settings, zero-shot and under two levels of adaptation. Site differences are summarized in Table R1 of our rebuttal. Adaptation subjects are disjoint from the test subjects, and all settings are evaluated on the same test subjects per site.\n\n**Table R3.** Cross-site performance. n is the number of test subjects at each site, disjoint from the train subjects used for adaptation. Intervals are subject-level bootstrap 95% CIs.\n\n| Site | Adaptation | # of Train Subjects | Acc | κ | MF1 |\n| --- | --- | --- | --- | --- | --- |\n| B (n=60) | none | 0 | 0.606 [0.560, 0.650] | 0.291 [0.238, 0.347] | 0.463 [0.418, 0.506] |\n| B | SDM only | 30 | 0.763 [0.737, 0.786] | 0.545 [0.503, 0.583] | 0.615 [0.576, 0.650] |\n| B | SDM only | 75 | 0.774 [0.747, 0.801] | 0.535 [0.489, 0.579] | 0.624 [0.579, 0.661] |\n| B | both modules | 30 | 0.786 [0.759, 0.813] | 0.549 [0.499, 0.598] | 0.627 [0.574, 0.674] |\n| B | both modules | 75 | 0.800 [0.774, 0.824] | 0.587 [0.542, 0.630] | 0.637 [0.588, 0.679] |\n| C (n=110) | none | 0 | 0.634 [0.616, 0.651] | 0.319 [0.285, 0.352] | 0.478 [0.442, 0.510] |\n| C | SDM only | 30 | 0.712 [0.694, 0.731] | 0.498 [0.466, 0.530] | 0.612 [0.578, 0.644] |\n| C | SDM only | 76 | 0.700 [0.683, 0.716] | 0.494 [0.466, 0.521] | 0.598 [0.569, 0.624] |\n| C | both modules | 30 | 0.714 [0.697, 0.729] | 0.502 [0.476, 0.528] | 0.598 [0.570, 0.623] |\n| C | both modules | 76 | 0.745 [0.730, 0.759] | 0.566 [0.541, 0.590] | 0.648 [0.616, 0.675] |\n\nWithout adaptation performance drops at both sites, and the drop takes a specific form. Each site collapses toward a different stage. At B, Light and REM epochs are absorbed into Wake, which is predicted about twice as often as it occurs, while at C the opposite happens and about half of the true Wake epochs are labelled Light. This points to the stage boundaries sitting at the wrong operating point rather than to epoch-level evidence being absent from the recordings.\n\nLight fine-tuning is consistent with that reading. Recalibrating SDM alone, without touching the representation module, already reaches 0.624 MF1 at B and 0.612 at C, and the errors above move back in the process, with the Light-to-Wake leakage at B falling from 23.7% to 5.0% and Wake recall at C rising from 42.5% to 70.4%.\n\nAdapting the representation module as well reaches 0.637 and 0.648. The two settings address different parts of the shift. Recalibrating the boundaries realigns the model to the local stage distribution, while adapting the extractor absorbs the change in apparent scale and direction of thoraco-abdominal motion that follows from a different camera and viewpoint. The latter is larger at C, adding 0.036 against 0.013 at B, consistent with C being the site whose camera angle differs from Hospital A while B shares it.\n\nAdaptation is also data-efficient. With 30 subjects, adapting both modules already reaches 0.786 accuracy at B, close to the 75-subject row, and 0.714 at C, where more data continues to help. MF1 and κ remain below Hospital A in every setting, so we look at where that residual sits stage by stage in the next comment."+ },+ "createdAt": "2026-08-01T13:36:45.598Z",+ "modifiedAt": "2026-11-19T17:17:17.124Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=3bcUWYAJ4N",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/3bhu9amear.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/3bhu9amear.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "3BHU9aMeAr",+ "replyTo": "zbYQSZqWMl",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (1-2/2)",+ "comment": "**Table R4.** Per-stage F1 across adaptation settings, with Hospital A for reference. Adaptation uses 75 subjects at B and 76 at C.\n\n| Stage | B zero-shot | B SDM only | B both | C zero-shot | C SDM only | C both | A |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| Wake | 0.385 | 0.629 | 0.663 | 0.498 | 0.688 | 0.712 | 0.776 |\n| Light | 0.723 | 0.844 | 0.861 | 0.736 | 0.762 | 0.803 | 0.834 |\n| Deep | 0.249 | 0.357 | 0.300 | 0.254 | 0.388 | 0.438 | 0.674 |\n| REM | 0.494 | 0.665 | 0.724 | 0.426 | 0.556 | 0.638 | 0.823 |\n\nWake, Light, and REM all move substantially toward Hospital A at both sites. Light matches or exceeds it, at 0.861 against 0.834 at B and 0.803 at C, and accuracy at B reaches 0.800 against 0.804.\n\nThe residual sits mainly in Deep, which remains 0.374 below Hospital A at B and 0.236 below at C, and since MF1 weights all four stages equally, that stage accounts for most of the remaining MF1 gap. It is also the stage whose prevalence differs most across sites, covering 9.4% of epochs at Hospital A against 3.0% at B and 3.6% at C. That difference is a property of the cohorts rather than of the recordings, since both external sites draw on populations further from healthy sleep than Hospital A, and it leaves the adaptation sets with roughly a third as many Deep epochs per subject to calibrate on. The residual Deep errors go predominantly to Light at both sites, the Deep-to-Light confusion characterized in the following comments, so this is an existing boundary under a much sparser Deep distribution rather than a failure specific to transfer.\n\nWhat fails to transfer is therefore calibration to the acquisition setup and to the local stage distribution, and both respond to a modest amount of site-specific data rather than requiring a new cohort at the scale of Hospital A. A gap nonetheless remains at both sites. Training used a single site, and the external cohorts differ from it in patient population as well as in recording setup, with both skewed further away from healthy sleep than Hospital A. Training across more sites and a wider range of populations and acquisition conditions is therefore likely to improve transfer on its own, and stronger domain adaptation is a further direction, since the settings used here are deliberately simple. We will report these results and both directions in §5."+ },+ "createdAt": "2026-08-01T13:19:09.236Z",+ "modifiedAt": "2026-11-19T17:17:17.409Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=3BHU9aMeAr",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/6mntg6tkjh.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/6mntg6tkjh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "6MNtg6tKJH",+ "replyTo": "t4d3aVbA0l",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (2-1/2)",+ "comment": "Continuing from the previous comment, we report the cross-site evaluation requested in [W2 / Q3].\n\n---\n\n**[W2 / Q3] Additional results: cross-site evaluation**\n\nWe evaluated the Hospital A model on Hospitals B and C, zero-shot and under two adaptation settings. Adaptation subjects are disjoint from evaluation subjects, and all settings are evaluated on the same subjects per site.\n\n**Table R6.** Cross-site performance. n is the number of test subjects at each site, disjoint from the train subjects used for adaptation. Intervals are subject-level bootstrap 95% CIs.\n\n| Site | Adaptation | # of Train Subjects | Acc | κ | MF1 |\n| --- | --- | --- | --- | --- | --- |\n| B (n=60) | none | 0 | 0.606 [0.560, 0.650] | 0.291 [0.238, 0.347] | 0.463 [0.418, 0.506] |\n| B | SDM only | 30 | 0.763 [0.737, 0.786] | 0.545 [0.503, 0.583] | 0.615 [0.576, 0.650] |\n| B | SDM only | 75 | 0.774 [0.747, 0.801] | 0.535 [0.489, 0.579] | 0.624 [0.579, 0.661] |\n| B | both modules | 30 | 0.786 [0.759, 0.813] | 0.549 [0.499, 0.598] | 0.627 [0.574, 0.674] |\n| B | both modules | 75 | 0.800 [0.774, 0.824] | 0.587 [0.542, 0.630] | 0.637 [0.588, 0.679] |\n| C (n=110) | none | 0 | 0.634 [0.616, 0.651] | 0.319 [0.285, 0.352] | 0.478 [0.442, 0.510] |\n| C | SDM only | 30 | 0.712 [0.694, 0.731] | 0.498 [0.466, 0.530] | 0.612 [0.578, 0.644] |\n| C | SDM only | 76 | 0.700 [0.683, 0.716] | 0.494 [0.466, 0.521] | 0.598 [0.569, 0.624] |\n| C | both modules | 30 | 0.714 [0.697, 0.729] | 0.502 [0.476, 0.528] | 0.598 [0.570, 0.623] |\n| C | both modules | 76 | 0.745 [0.730, 0.759] | 0.566 [0.541, 0.590] | 0.648 [0.616, 0.675] |\n\nWithout adaptation performance drops at both sites, and the drop takes a specific form. Each site collapses toward a different stage. At B, Light and REM epochs are absorbed into Wake, which is predicted about twice as often as it occurs, while at C the opposite happens and about half of the true Wake epochs are labelled Light. This points to the stage boundaries sitting at the wrong operating point rather than to epoch-level evidence being absent from the recordings.\n\nAdaptation is consistent with that reading. Recalibrating SDM alone, without touching the representation module, already reaches 0.624 MF1 at B and 0.612 at C, and the errors above move back in the process, with the Light-to-Wake leakage at B falling from 23.7% to 5.0% and Wake recall at C rising from 42.5% to 70.4%. Adapting the representation module as well reaches 0.637 and 0.648. The two settings address different parts of the shift. Recalibrating the boundaries realigns the model to the local stage distribution, while adapting the extractor absorbs the change in apparent scale and direction of thoraco-abdominal motion that follows from a different camera and viewpoint. The latter is larger at C, adding 0.036 against 0.013 at B, consistent with C being the site whose camera angle differs from Hospital A while B shares it.\n\nAdaptation is data-efficient. With 30 subjects, adapting both modules already reaches 0.786 accuracy at B and 0.714 at C, and fewer than 100 subjects per site recover most of the accuracy gap. MF1 and κ remain lower than at Hospital A in every setting, so we look at where that residual sits stage by stage in the next comment."+ },+ "createdAt": "2026-08-01T13:03:18.930Z",+ "modifiedAt": "2026-11-19T17:17:17.354Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=6MNtg6tKJH",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/72yrfjjawg.json modified
+++ b/reviews/openreview/5wh6aa0lyo/notes/72yrfjjawg.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair znbX","content": {- "metareview": "Reviewers find the use case real and the recording conditions genuinely demanding. They also point to the scale of the clinical cohort as a strength unusual for this modality. KeGQ and 4pmZ describe the video-only formulation as original and practical, since it avoids the failure modes of reconstructing physiological proxies under occlusion and anonymization. uFaX notes that the design choices follow from documented properties of the data, pointing to the diagnostic analyses that motivate each component. 4pmZ rates significance excellent.\n\nConcerns: Reviewers ask for evaluation beyond the single cohort, noting that the work is entirely intra-dataset and that robustness to domain shift is therefore unverified. uFaX frames this strongly and states that an argument about the modality itself depends on generalization beyond one hospital. KeGQ and 4pmZ request analysis stratified by disease severity, given that a large share of the cohort has severe sleep apnea, and both want to know whether pathological respiratory motion is confused with stage-relevant motion. KeGQ and 4pmZ also raise reproducibility, asking for release of code, weights, or a demonstration.\n\nReviewer uFaX identifies a gap in the argument: the paper says that learning directly from video is preferable to extracting physiological proxies, but never tests whether the video alone carries the evidence. The reviewer proposes a direct experiment that would settle this and also notes that all evaluation rests on one split with no variance estimates or significance tests. 4pmZ questions whether the comparison against the proxy-based baseline is fair given differences in what each method was trained on, and finds the split protocol underspecified. KeGQ raises the low frame rate and the missing optical configuration, and asks for failure-mode analysis.\n\nThe authors should address:\n- the proxy-input experiment that would test the video-only argument directly\n- variance estimates or significance tests\n- explicit pointers to the split description and the stratified appendix\n- reconciliation of the baseline comparison\nand the other details on the reviews.\n\n\n---\n\nThe authors addressed the main concerns raised during review. Most importantly, the proxy-fusion ablation directly addresses Reviewer uFaX’s central concern. Adding the reconstructed breathing proxy reduces performance. Adding clean contact-sensor breathing and cardiac waveforms provides no measurable improvement over video-only ViNUSS. The appropriate conclusion is that the evaluated waveform proxies provide no measurable incremental benefit to the video representation. The authors also added subject-level bootstrap confidence intervals for all methods. They strengthened the SleepVST comparison by fine-tuning its waveform encoder on KVSS.\n\nThe authors evaluated transfer to two held-out KVSS sites. Zero-shot performance drops clearly at both sites. Site-specific adaptation recovers much of the loss, although macro-F1 remains below the Hospital A result. This gives useful evidence on cross-site transfer and identifies an important limitation. The authors also clarified that the split is subject-independent and temporally disjoint. They extended the analysis of OSA severity to individual respiratory events. Their failure-mode analysis covers boundary timing, blanket coverage, sleep position, breathing regularity, respiratory events and limb movement. The main remaining error pattern is Deep-to-Light confusion. The discussion also clarified the 5 fps constraint and the available information about the optical setup. The authors committed to release the code, preprocessing pipeline and trained checkpoints upon acceptance.\n\nThe reviewer follow-up is consistent with acceptance. Reviewer uFaX considers the primary concern addressed. Reviewer KeGQ states that most concerns were addressed and votes for acceptance. Reviewer 4pmZ recommends acceptance after the additional validation and ablation results. I therefore maintain Accept (poster).\n\nFor the camera-ready, the paper should include the experiments and analyses added during discussion together with their limitations. In particular, it should state the cross-site gap clearly and use the narrower conclusion that the evaluated waveform proxies provide no measurable incremental benefit. It should also add clear main-text pointers to the split description and stratified analyses. The authors should release the code, preprocessing pipeline and trained checkpoints as committed."+ "metareview": "Reviewers find the use case real and the recording conditions genuinely demanding. They also point to the scale of the clinical cohort as a strength unusual for this modality. KeGQ and 4pmZ describe the video-only formulation as original and practical, since it avoids the failure modes of reconstructing physiological proxies under occlusion and anonymization. uFaX notes that the design choices follow from documented properties of the data, pointing to the diagnostic analyses that motivate each component. 4pmZ rates significance excellent.\n\nConcerns: Reviewers ask for evaluation beyond the single cohort, noting that the work is entirely intra-dataset and that robustness to domain shift is therefore unverified. uFaX frames this strongly and states that an argument about the modality itself depends on generalization beyond one hospital. KeGQ and 4pmZ request analysis stratified by disease severity, given that a large share of the cohort has severe sleep apnea, and both want to know whether pathological respiratory motion is confused with stage-relevant motion. KeGQ and 4pmZ also raise reproducibility, asking for release of code, weights, or a demonstration.\n\nReviewer uFaX identifies a gap in the argument: the paper says that learning directly from video is preferable to extracting physiological proxies, but never tests whether the video alone carries the evidence. The reviewer proposes a direct experiment that would settle this and also notes that all evaluation rests on one split with no variance estimates or significance tests. 4pmZ questions whether the comparison against the proxy-based baseline is fair given differences in what each method was trained on, and finds the split protocol underspecified. KeGQ raises the low frame rate and the missing optical configuration, and asks for failure-mode analysis.\n\nThe authors should address:\n- the proxy-input experiment that would test the video-only argument directly\n- variance estimates or significance tests\n- explicit pointers to the split description and the stratified appendix\n- reconciliation of the baseline comparison\nand the other details on the reviews.\n\n\n---\n\nThe authors addressed the main concerns raised during review. Most importantly, the proxy-fusion ablation directly addresses Reviewer uFaX’s central concern. Adding the reconstructed breathing proxy reduces performance. Adding clean contact-sensor breathing and cardiac waveforms provides no measurable improvement over video-only ViNUSS. The appropriate conclusion is that the evaluated waveform proxies provide no measurable incremental benefit to the video representation. The authors also added subject-level bootstrap confidence intervals for all methods. They strengthened the SleepVST comparison by fine-tuning its waveform encoder on KVSS.\n\nThe authors evaluated transfer to two held-out KVSS sites. Zero-shot performance drops clearly at both sites. Site-specific adaptation recovers much of the loss, although macro-F1 remains below the Hospital A result. This gives useful evidence on cross-site transfer and identifies an important limitation. The authors also clarified that the split is subject-independent and temporally disjoint. They extended the analysis of OSA severity to individual respiratory events. Their failure-mode analysis covers boundary timing, blanket coverage, sleep position, breathing regularity, respiratory events and limb movement. The main remaining error pattern is Deep-to-Light confusion. The discussion also clarified the 5 fps constraint and the available information about the optical setup. The authors committed to release the code, preprocessing pipeline and trained checkpoints upon acceptance.\n\nThe reviewer follow-up is consistent with acceptance. Reviewer uFaX considers the primary concern addressed. Reviewer KeGQ states that most concerns were addressed and votes for acceptance. Reviewer 4pmZ recommends acceptance after the additional validation and ablation results. I therefore maintain Accept (poster).\n\nFor the camera-ready, the paper should include the experiments and analyses added during discussion together with their limitations. In particular, it should state the cross-site gap clearly and use the narrower conclusion that the evaluated waveform proxies provide no measurable incremental benefit. It should also add clear main-text pointers to the split description and stratified analyses. The authors should release the code, preprocessing pipeline and trained checkpoints as committed.",+ "final_justification": "The proxy-fusion ablation directly addresses the main concern. Neither reconstructed nor clean contact-sensor waveform proxies improve over video-only ViNUSS. Subject-level bootstrap confidence intervals were added across methods. The SleepVST baseline was strengthened through fine-tuning on KVSS.\n\nCross-site evaluation on two held-out KVSS sites shows a clear zero-shot transfer gap. Site-specific adaptation recovers much of the loss. The authors also clarified the data split and extended the clinical subgroup and failure-mode analyses.\n\nReviewer uFaX considers the primary concern addressed. Reviewer KeGQ votes for acceptance. Reviewer 4pmZ recommends acceptance after the new analyses. The remaining limitations, especially the cross-site gap, do not change my recommendation."},"createdAt": "2026-07-22T21:03:40.132Z",- "modifiedAt": "2026-11-18T15:23:20.383Z",+ "modifiedAt": "2026-11-19T05:02:04.853Z","url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=72yrFJJAwG","license": "CC-BY-4.0"}
reviews/openreview/5wh6aa0lyo/notes/alajkssr68.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/alajkssr68.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "aLAjKSsR68",+ "replyTo": "gqzJaghL1S",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (2-2/3)",+ "comment": "**Table R4.** Per-stage F1 across adaptation settings, with Hospital A for reference. Adaptation uses 75 subjects at B and 76 at C.\n\n| Stage | B zero-shot | B SDM only | B both | C zero-shot | C SDM only | C both | A |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| Wake | 0.385 | 0.629 | 0.663 | 0.498 | 0.688 | 0.712 | 0.776 |\n| Light | 0.723 | 0.844 | 0.861 | 0.736 | 0.762 | 0.803 | 0.834 |\n| Deep | 0.249 | 0.357 | 0.300 | 0.254 | 0.388 | 0.438 | 0.674 |\n| REM | 0.494 | 0.665 | 0.724 | 0.426 | 0.556 | 0.638 | 0.823 |\n\nWake, Light, and REM all move substantially toward Hospital A at both sites. Light matches or exceeds it, at 0.861 against 0.834 at B and 0.803 at C, and accuracy at B reaches 0.800 against 0.804.\n\nThe residual sits mainly in Deep, which remains 0.374 below Hospital A at B and 0.236 below at C, and since MF1 weights all four stages equally, that stage accounts for most of the remaining MF1 gap. It is also the stage whose prevalence differs most across sites, covering 9.4% of epochs at Hospital A against 3.0% at B and 3.6% at C. That difference is a property of the cohorts rather than of the recordings, since both external sites draw on populations further from healthy sleep than Hospital A, and it leaves the adaptation sets with roughly a third as many Deep epochs per subject to calibrate on. These errors go predominantly to Light at both sites, the same axis that the event analysis in the following comments identifies at Hospital A, so what we see here is an existing boundary under a much sparser Deep distribution rather than a failure specific to transfer.\n\nWhat fails to transfer is therefore calibration to the acquisition setup and to the local stage distribution, and both respond to a modest amount of site-specific data rather than requiring a new cohort at the scale of Hospital A. A gap nonetheless remains at both sites. Training used a single site, and the external cohorts differ from it in patient population as well as in recording setup, with both skewed further away from healthy sleep than Hospital A. Training across more sites and a wider range of populations and acquisition conditions is therefore likely to improve transfer on its own, and stronger domain adaptation is a further direction, since the settings used here are deliberately simple. We will report these results and both directions in §5."+ },+ "createdAt": "2026-08-01T13:38:30.786Z",+ "modifiedAt": "2026-11-19T17:17:17.101Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=aLAjKSsR68",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/bvr93rlm3w.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/bvr93rlm3w.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "bVR93Rlm3W",+ "replyTo": "t4d3aVbA0l",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (1/2)",+ "comment": "Following up on our rebuttal, we report the completed results for the two experiments we described as underway. This comment covers the proxy-fusion ablation in [W1 / Q1], and the cross-site evaluation in [W2 / Q3] follows in a second comment.\n\n---\n**[W1 / Q1] Additional results: the requested proxy-fusion ablation**\n\nAs described in the rebuttal, the waveform representation is concatenated with the ViNUSS video representation with everything else unchanged from Table 1. Since face anonymization rules out rPPG, cardiac waveform CW* comes from the contact sensor in both conditions, while the breathing waveform is evaluated both reconstructed from video (BW) and as a contact-sensor oracle (BW*). **Neither improves on video-only ViNUSS.**\n\n**Table R4.** Four-class staging with proxy features fused into the ViNUSS video representation. BW is reconstructed from video, and BW* and CW* are contact-sensor waveforms. The waveform encoder is fine-tuned on KVSS. Intervals are subject-level bootstrap 95% CIs, as in Table R2.\n\n| Method | Input / Proxy | Acc | κ | MF1 |\n| --- | --- | --- | --- | --- |\n| Proxy fusion | BW + CW* + video | 0.762 [0.739, 0.782] | 0.614 [0.581, 0.644] | 0.721 [0.697, 0.744] |\n| Proxy fusion | BW* + CW* + video | 0.802 [0.781, 0.821] | 0.683 [0.651, 0.711] | 0.769 [0.743, 0.792] |\n| **ViNUSS** | **Video only** | **0.804** [0.784, 0.823] | **0.684** [0.650, 0.713] | **0.777** [0.754, 0.797] |\n\nWith the reconstructed breathing waveform, fusion is worse than video alone by 0.042 accuracy, 0.070 κ, and 0.056 MF1, with clearly separated intervals on κ and MF1 and marginally separated intervals on accuracy. This is consistent with Fig. 1, where reconstructed respiration departs from the contact signal in dominant frequency and amplitude under bedding, position changes, and non-respiratory movement, and a channel carrying such error can hurt rather than help. This row is nonetheless the closest to contact-free operation among the configurations tested, and even it is optimistic, since CW* still comes from a contact sensor. Whether better reconstruction would change the picture is answered by the BW* row, which is the limit a perfect video-to-waveform extractor would approach.\n\nReplacing BW with the contact-sensor waveform removes that error, and fusion then becomes indistinguishable from video alone rather than better than it. The differences of −0.002 accuracy, −0.001 κ, and −0.008 MF1 are an order of magnitude smaller than the interval widths. This meets the reviewer's criterion directly. Even given clean contact measurements of both breathing and cardiac activity, and an encoder fine-tuned on our data, the proxy branch adds no benefit we can measure. This supports the claim in the paper, that face-anonymized NIR video is independently informative for PSG-defined sleep staging and reaches this level without reconstructing waveforms at inference.\n\n**Table R5.** Per-stage F1 for the fusion configurations.\n\n| Method | Input / Proxy | Wake | Light | Deep | REM |\n| --- | --- | --- | --- | --- | --- |\n| Proxy fusion | BW + CW* + video | 0.738 [0.700, 0.773] | 0.802 [0.781, 0.821] | 0.594 [0.539, 0.645] | 0.751 [0.703, 0.794] |\n| Proxy fusion | BW* + CW* + video | 0.787 [0.756, 0.815] | 0.831 [0.812, 0.850] | 0.631 [0.573, 0.685] | 0.829 [0.775, 0.869] |\n| **ViNUSS** | **Video only** | 0.776 [0.739, 0.810] | 0.834 [0.814, 0.853] | 0.674 [0.622, 0.720] | 0.823 [0.784, 0.856] |\n\nUnder the contact-sensor waveform, the per-stage intervals overlap throughout and neither configuration is consistently ahead. The differences are small on Wake, Light, and REM, and larger on Deep at 0.043, which is the sparsest stage (~9%) and the one carrying by far the widest interval of the four. Deep is also the stage the waveform models handle least well on their own. In the confusion matrices of the signal-only models in Table R1, 45 to 53% of true Deep epochs are recovered, with most of the remainder labelled Light, against 68% for video-only ViNUSS. Under the reconstructed waveform all four stages fall together, which is what a degraded input channel looks like rather than an interaction specific to one stage.\n\nWe will add Tables R4 and R5 to Appendix D as a proxy-fusion ablation, referenced from §4.2, noting that the configuration closest to contact-free deployment performs worse than video alone, and that oracle waveforms add nothing over video either."+ },+ "createdAt": "2026-08-01T12:55:24.167Z",+ "modifiedAt": "2026-11-19T17:17:17.261Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=bVR93Rlm3W",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/dvr3sp7khj.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/dvr3sp7khj.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "dvR3SP7KhJ",+ "replyTo": "gqzJaghL1S",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (3-2/3)",+ "comment": "**Table R7.** Four-class MF1 by AHI severity and epoch type, computed within each subset. The Normal event subset contains no true Deep epochs, so a four-class MF1 is not defined there and we leave it out rather than report a value that depends on the convention chosen. Overall covers all 70 test subjects.\n\n| Severity | Subjects | Event-free | Event | Δ | 95% CI on Δ |\n| --- | --- | --- | --- | --- | --- |\n| Normal | 6 | 0.746 | — | — | — |\n| Mild | 15 | 0.797 | 0.723 | −0.074 | [−0.219, −0.004] |\n| Moderate | 19 | 0.762 | 0.666 | −0.095 | [−0.168, −0.032] |\n| Severe | 30 | 0.775 | 0.610 | −0.165 | [−0.208, −0.115] |\n| Overall | 70 | 0.778 | 0.645 | −0.133 | [−0.177, −0.085] |\n\nEvent-free MF1 spans 0.051 across the four severity groups and is not ordered by severity, being lowest in Normal and highest in Mild, so OSA severity by itself does not shift average staging performance. Appendix D.3 shows the same at subject level, with wider spread at higher AHI. The event-related drop is present in Mild, Moderate, and Severe with intervals excluding zero, so it is not confined to severe disease. The point estimates grow with severity, but the intervals overlap throughout and we do not treat that ordering as established.\n\nWe also checked a movement-heavy subgroup, since limb movement is a different class of abnormal motion that could plausibly be confused with arousal-related motion. The 21 of 70 test subjects with a periodic limb movement index of 5 or higher reach 0.766 MF1 [0.731, 0.798] against 0.781 [0.752, 0.806] for the rest, a difference of −0.015 [−0.059, +0.028], with accuracy and κ likewise not distinguishable. These subjects are 11 years older on average, so we would not attribute the point estimate cleanly to limb movement in any case, but we find no detectable difference.\n\nOverall, severity does not lower average staging performance, while within individual respiratory events staging degrades along the Deep to Light axis. We will add this analysis to the appendix and note the event-level constraint in the limitations, which currently does not address pathological motion profiles.\n\n---\n\nWe hope these results address the remaining questions, and we are glad to run further analyses during the discussion period."+ },+ "createdAt": "2026-08-01T13:48:12.547Z",+ "modifiedAt": "2026-11-19T17:17:17.098Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=dvR3SP7KhJ",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/gqzjaghl1s.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/gqzjaghl1s.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "gqzJaghL1S",+ "replyTo": "eB5cUezUtP",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 4pmZ",+ "content": {+ "comment": "Thank you to the authors for the detailed explanation of my concerns. I look forward to further discussion once the updated results are available. If the new results successfully address my questions, I will consider raising my score."+ },+ "createdAt": "2026-07-30T15:08:22.403Z",+ "modifiedAt": "2026-11-19T17:17:17.365Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=gqzJaghL1S",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/jkjbfeb8xs.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/jkjbfeb8xs.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "JKJBfeB8xs",+ "replyTo": "Z8NoPf5Kq9",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer uFaX",+ "content": {+ "comment": "Thanks the authors for the response. I consider my primary concern addressed. I encourge the authors to include the additional experiments in the revised paper, phrase the conclusions to detailed level (e.g., the evaluated waveform proxies provide no measurable incremental benefit), and explicitly state the limitations (e.g., cross-site gap)."+ },+ "createdAt": "2026-08-03T02:27:56.282Z",+ "modifiedAt": "2026-11-19T17:17:16.965Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=JKJBfeB8xs",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/nzjuynmli7.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/nzjuynmli7.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "NzjUYNmLI7",+ "replyTo": "zbYQSZqWMl",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (1-1/2)",+ "comment": "We thank the reviewer for the follow-up comment. Both experiments we described as underway are now complete. These comments cover the cross-site evaluation for [W1 / Q1], and the error-concentration analysis for [W3 / Q3] follows.\n\n---\n\n**[W1/Q1] Additional results: cross-site evaluation**\n\nFollowing the reviewer's suggestion that zero-shot or light fine-tuning at another site would strengthen the paper, we evaluated the Hospital A model on Hospitals B and C in all three settings. Site differences are summarized in Table R1 of our rebuttal. Adaptation subjects are disjoint from evaluation subjects, and all settings are evaluated on the same subjects per site.\n\n**Table R3.** Cross-site performance. n is the number of test subjects at each site, disjoint from the train subjects used for adaptation. Intervals are subject-level bootstrap 95% CIs.\n\n| Site | Adaptation | # of Train Subjects | Acc | κ | MF1 |\n| --- | --- | --- | --- | --- | --- |\n| B (n=60) | none | 0 | 0.606 [0.560, 0.650] | 0.291 [0.238, 0.347] | 0.463 [0.418, 0.506] |\n| B | SDM only | 30 | 0.763 [0.737, 0.786] | 0.545 [0.503, 0.583] | 0.615 [0.576, 0.650] |\n| B | SDM only | 75 | 0.774 [0.747, 0.801] | 0.535 [0.489, 0.579] | 0.624 [0.579, 0.661] |\n| B | both modules | 30 | 0.786 [0.759, 0.813] | 0.549 [0.499, 0.598] | 0.627 [0.574, 0.674] |\n| B | both modules | 75 | 0.800 [0.774, 0.824] | 0.587 [0.542, 0.630] | 0.637 [0.588, 0.679] |\n| C (n=110) | none | 0 | 0.634 [0.616, 0.651] | 0.319 [0.285, 0.352] | 0.478 [0.442, 0.510] |\n| C | SDM only | 30 | 0.712 [0.694, 0.731] | 0.498 [0.466, 0.530] | 0.612 [0.578, 0.644] |\n| C | SDM only | 76 | 0.700 [0.683, 0.716] | 0.494 [0.466, 0.521] | 0.598 [0.569, 0.624] |\n| C | both modules | 30 | 0.714 [0.697, 0.729] | 0.502 [0.476, 0.528] | 0.598 [0.570, 0.623] |\n| C | both modules | 76 | 0.745 [0.730, 0.759] | 0.566 [0.541, 0.590] | 0.648 [0.616, 0.675] |\n\nWithout adaptation performance drops at both sites, and the drop takes a specific form. Each site collapses toward a different stage. At B, Light and REM epochs are absorbed into Wake, which is predicted about twice as often as it occurs, while at C the opposite happens and about half of the true Wake epochs are labelled Light. This points to the stage boundaries sitting at the wrong operating point rather than to epoch-level evidence being absent from the recordings.\n\nLight fine-tuning is consistent with that reading. Recalibrating SDM alone, without touching the representation module, already reaches 0.624 MF1 at B and 0.612 at C, and the errors above move back in the process, with the Light-to-Wake leakage at B falling from 23.7% to 5.0% and Wake recall at C rising from 42.5% to 70.4%.\n\nAdapting the representation module as well reaches 0.637 and 0.648. The two settings address different parts of the shift. Recalibrating the boundaries realigns the model to the local stage distribution, while adapting the extractor absorbs the change in apparent scale and direction of thoraco-abdominal motion that follows from a different camera and viewpoint. The latter is larger at C, adding 0.036 against 0.013 at B, consistent with C being the site whose camera angle differs from Hospital A while B shares it. We will discuss camera placement in the limitations with reference to these results rather than as a general caveat.\n\nAdaptation is also data-efficient. With 30 subjects, adapting both modules already reaches 0.786 accuracy at B, close to the 75-subject row, and 0.714 at C, where more data continues to help. MF1 and κ remain below Hospital A in every setting, so we look at where that residual sits stage by stage in the next comment."+ },+ "createdAt": "2026-08-01T13:17:44.969Z",+ "modifiedAt": "2026-11-19T17:17:17.185Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=NzjUYNmLI7",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/o9vgkdqtma.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/o9vgkdqtma.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "o9vGkdQTma",+ "replyTo": "gqzJaghL1S",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (1/3)",+ "comment": "We thank the reviewer for waiting. The experiments we described as underway are now complete, and we report them across the comments below, together with the event-level analysis requested under [W4 / Q4].\n\n---\n\n**[W1 / Q1] Additional results, part 1. Fine-tuning the SleepVST waveform encoder on KVSS**\n\nWe fine-tuned the waveform encoder on KVSS as suggested, so that every component of the baseline sees the target data. Each variant is fine-tuned on the waveform it is tested on, since we found that fine-tuning on one waveform does not carry over to the other.\n\n**Table R2.** SleepVST on KVSS before and after fine-tuning the waveform encoder. All rows include the optical-flow motion feature (M). BW* and CW* are contact-sensor waveforms and BW is reconstructed from video. Intervals are subject-level bootstrap 95% CIs.\n\n| Waveform input | Encoder | Acc | κ | MF1 |\n| --- | --- | --- | --- | --- |\n| BW* + CW* + M | SHHS + MESA (Table 1) | 0.784 [0.763, 0.802] | 0.635 [0.599, 0.667] | 0.726 [0.698, 0.751] |\n| BW* + CW* + M | + fine-tuned on KVSS | 0.799 [0.779, 0.817] | 0.663 [0.628, 0.694] | 0.748 [0.721, 0.772] |\n| BW + CW* + M | SHHS + MESA (Table 1) | 0.612 [0.592, 0.631] | 0.236 [0.208, 0.266] | 0.371 [0.344, 0.400] |\n| BW + CW* + M | + fine-tuned on KVSS | 0.674 [0.648, 0.700] | 0.422 [0.375, 0.470] | 0.571 [0.533, 0.610] |\n| Video only | **ViNUSS** | **0.804** [0.784, 0.823] | **0.684** [0.650, 0.713] | **0.777** [0.754, 0.797] |\n\nFine-tuning helps the baseline in both conditions, by 0.022 MF1 with the contact-sensor waveform and by 0.200 with the reconstructed one. The reviewer's concern was well placed, and the stronger baseline is the one we should be compared against.\n\nWith contact-sensor waveforms the fine-tuned baseline reaches 0.748 [0.721, 0.772] against 0.777 [0.754, 0.797] for video-only ViNUSS, and the intervals overlap substantially. We do not claim a reliable advantage over the baseline in that configuration. What it shows is that staging from face-anonymized video alone is on par with a proxy pipeline that has been given clean contact measurements of both breathing and cardiac activity and adapted to our cohort.\n\nThat configuration is not available without an effort belt. In the configuration that a contactless system could actually run, with the breathing waveform reconstructed from video, the strongest baseline we could construct reaches 0.571 [0.533, 0.610] against 0.777, with no overlap on any metric. This is the comparison the paper's claim rests on, and we will report both conditions in the revision so the baseline is represented at its strongest.\n\nThe cross-dataset validation results follow in the next comment."+ },+ "createdAt": "2026-08-01T13:33:42.306Z",+ "modifiedAt": "2026-11-19T17:17:17.704Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=o9vGkdQTma",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/s8qbosimid.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/s8qbosimid.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "s8QBoSiMId",+ "replyTo": "72yrFJJAwG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Summary of the discussion period",+ "comment": "We thank the AC for the Meta Review. We are grateful that it captures both what the reviewers found valuable in the work and what needed to be shown, and the four points it lists gave us a clear agenda for the discussion period. We also thank the reviewers for feedback that was constructive throughout, and we believe the additional experiments and analyses conducted in response have made the paper more solid.\n\nThe first two points, the proxy-input experiment and the variance estimates, were raised by Reviewer uFaX. We ran the requested proxy-fusion ablation, which shows no measurable benefit from adding waveform proxies to the video representation, and applied subject-level bootstrap CIs to every result including all baselines. The reviewer has since confirmed the primary concern addressed and moved the rating into the accept range.\n\nThe split description and the stratified appendix were both already in the paper but not signposted from the main text. During the discussion we confirmed subject independence and temporal disjointness, and extended the AHI-stratified analysis in Appendix D.3 to individual respiratory events and to severity groups. We will add explicit pointers along with the expanded content.\n\nOn the baseline comparison and the other details raised in the reviews, we fine-tuned the SleepVST waveform encoder on KVSS so that every component sees the target data, and report against that stronger baseline. On reproducibility, an anonymized implementation is already included with the submission, and we detailed what will be released on acceptance and why checkpoints and a hosted demo cannot be attached during discussion. We also specified the optical setup and the frame-rate constraint, both of which we will add to the paper.\n\nEvaluation beyond the single cohort was raised by all three reviewers. We ran the cross-site evaluation on two held-out KVSS sites zero-shot and under two adaptation settings, together with the analyses each reviewer requested on failure modes, respiratory events, and disease severity. Reviewers KeGQ and 4pmZ indicated they would reassess once these results were available, and we have reported each of them in full in their threads.\n\nEvery result and analysis reported during the discussion will be added to the paper, together with the limitations they make explicit. We thank the AC and the reviewers for the time and care they have given this submission."+ },+ "createdAt": "2026-08-04T09:15:28.920Z",+ "modifiedAt": "2026-11-19T17:17:16.957Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=s8QBoSiMId",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/t4d3avba0l.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/t4d3avba0l.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "t4d3aVbA0l",+ "replyTo": "YOVfKTOew0",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer uFaX",+ "content": {+ "comment": "Thank you for the detailed response. I will reassess the concern and my overall evaluation once the pending results are available."+ },+ "createdAt": "2026-07-30T02:33:11.549Z",+ "modifiedAt": "2026-11-19T17:17:17.405Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=t4d3aVbA0l",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/u73nawdyy8.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/u73nawdyy8.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "U73NawDyY8",+ "replyTo": "zbYQSZqWMl",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (2-1/2)",+ "comment": "**[W3/Q3] Additional results: where errors concentrate**\n\nWe reported the timing-offset analysis in our rebuttal (Table R2). Here we report where the remaining errors concentrate, across the three conditions the reviewer names and two further ones. The pattern is consistent enough to state first. Across these conditions the errors move along one axis rather than rising uniformly. Sleep position, the regularity of a subject's breathing during Deep, and the presence of a respiratory event each act on how often Deep is read as Light while leaving the other stages largely unaffected, and heavy bedding occlusion produces a small broad drop. All intervals are 95% bootstrap CIs resampling the 70 test subjects, so within-subject correlation is preserved.\n\n**(a) Bedding occlusion.** \n\nOne correction to our rebuttal first. KVSS does not annotate blanket coverage, and the three levels used in Appendix D.3 are our own labels from visual review. A recording is fully covered when the blanket covers the body throughout the night, uncovered when it does not, and partial otherwise, a category that mixes partial body coverage with coverage that changes during the night.\n\n**Table R5.** Performance by blanket coverage, pooled over epochs within each group.\n\n| Coverage | Subjects | Accuracy | κ | MF1 |\n| --- | --- | --- | --- | --- |\n| None | 18 | 0.817 [0.778, 0.854] | 0.692 [0.624, 0.754] | 0.770 [0.717, 0.811] |\n| Partial | 19 | 0.840 [0.820, 0.860] | 0.735 [0.706, 0.765] | 0.801 [0.771, 0.828] |\n| Full | 33 | 0.777 [0.743, 0.810] | 0.649 [0.595, 0.698] | 0.762 [0.727, 0.795] |\n\nPerformance is not ordered by how much of the body is covered, since partial coverage is highest on all three metrics. Contrasting fully covered against the rest, which is the comparison the reviewer's question concerns, gives Δ accuracy −0.052 [−0.091, −0.014], Δ κ −0.067 [−0.129, −0.009], and Δ MF1 −0.026 [−0.069, +0.016]. Heavy occlusion is associated with a small drop in accuracy and κ, matching the reviewer's expectation, and we will note it in the limitations.\n\nCoverage is a coarse subject-level label rather than a per-epoch annotation of visible body area, so this compares 33 subjects against 37 rather than conditions within one recording, and subject-level variation within each coverage group is larger than the difference between groups.\n\n**(b) Sleep position.** \n\nPosition is annotated as Supine or Non-Supine, with lateral and prone grouped into the latter, so a prone-only analysis is not possible.\n\n**Table R6.** Performance by position, pooled over epochs within each group. Fifteen epochs with missing position annotation are excluded.\n\n| Position | Epochs | Accuracy | κ | MF1 |\n| --- | --- | --- | --- | --- |\n| Supine | 37,807 | 0.802 [0.777, 0.825] | 0.666 [0.626, 0.703] | 0.752 [0.725, 0.777] |\n| Non-Supine | 20,096 | 0.809 [0.786, 0.832] | 0.709 [0.674, 0.742] | 0.800 [0.774, 0.823] |\n\nAccuracy differs by 0.007 with heavily overlapping intervals while MF1 differs by 0.048, so the difference sits in the minority stages rather than in staging overall. Since position is annotated per epoch, we compute the paired within-subject change per stage, reporting recall alongside F1 because the two positions have different stage compositions, to which F1 is sensitive and recall is not.\n\n**Table R7.** Per-stage change from Supine to Non-Supine, with paired subject-cluster bootstrap 95% CIs. Deep is present in both positions for 19 of 70 subjects, which widens its recall interval.\n\n| Stage | Δ recall | 95% CI | Δ F1 | 95% CI |\n| --- | --- | --- | --- | --- |\n| Wake | −0.018 | [−0.074, +0.034] | +0.010 | [−0.037, +0.056] |\n| Light | +0.011 | [−0.029, +0.054] | −0.009 | [−0.040, +0.022] |\n| Deep | +0.046 | [−0.082, +0.173] | +0.147 | [+0.049, +0.246] |\n| REM | +0.099 | [+0.020, +0.182] | +0.043 | [−0.025, +0.114] |\n\nDeep and REM are the two stages with a change reliably above zero, Deep on F1 and REM on recall. Wake and Light are unchanged. Respiratory events are more frequent supine and events themselves degrade staging, so this could be an event effect in disguise. Restricting to event-free epochs, REM recall is 0.764 supine against 0.897 non-supine, so the difference is not driven by events. Supine is also the majority position here at 65% of epochs, so the headline numbers already come mostly from the less favourable position. Deep moves on F1 while REM moves on recall, and the Deep effect is the confusion that (c) and (d) return to.\n\nConditions (c) and (d) follow in the next comment."+ },+ "createdAt": "2026-08-01T13:51:04.046Z",+ "modifiedAt": "2026-11-19T17:17:17.068Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=U73NawDyY8",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/veogjbf5po.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/veogjbf5po.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "VeOgJBf5Po",+ "replyTo": "zbYQSZqWMl",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (2-3/2)",+ "comment": "**(e) Movement-heavy subgroup.** \n\nLimb movement is a different class of abnormal motion that could plausibly be confused with arousal-related motion. The 21 of 70 test subjects with a periodic limb movement index of 5 or higher reach 0.766 MF1 [0.731, 0.798] against 0.781 [0.752, 0.806] for the rest, a difference of −0.015 [−0.059, +0.028], with accuracy and κ likewise not distinguishable. These subjects are 11 years older on average, so the point estimate cannot be attributed cleanly to limb movement, but we find no detectable degradation.\n\nTaken together, the residual errors are not spread evenly. Beyond the boundary-timing offsets in Table R2, they concentrate on a single axis, Deep being read as Light, and it happens where Deep is least distinctive, in subjects whose Deep-epoch breathing lacks the regular slow pattern typical of the stage and in epochs carrying a respiratory event.\n\nThe conditions that do not degrade staging are worth stating as well, since they are the ones raised as likely failure modes. Sleep position and limb movement leave overall staging unchanged, respiratory events act through one stage rather than across the board, and heavy occlusion costs less than the subject-level spread within any coverage group. Together with the subject-level stratification already in Appendix D.3, this covers the recording and physiological conditions a reader would expect to be difficult. We do not account for every error, but those raised as likely failure modes either leave performance intact or act through the one boundary above.\n\nWe will add these analyses to the appendix and reference them from the error discussion in §4.2.\n\n---\n\nWe hope these results address the remaining concern, and we are glad to run further analyses during the discussion period."+ },+ "createdAt": "2026-08-01T13:57:43.798Z",+ "modifiedAt": "2026-11-19T17:17:16.968Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=VeOgJBf5Po",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/waijelxfy1.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/waijelxfy1.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "wAIJeLxFY1",+ "replyTo": "zbYQSZqWMl",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (2-2/2)",+ "comment": "**(c) Baseline respiratory amplitude.** \n\nThe contact breathing signal is per-subject normalized in KVSS, with RMS close to 1 for every subject, so amplitude cannot be compared across subjects and the reviewer's hypothesis cannot be tested in its original form. Normalization need not remove the underlying difference, though. A shallow signal scaled to unit RMS may carry relatively more noise and less well-defined periodicity than a deep one, so an amplitude difference can reappear as a difference in waveform regularity. We measure regularity per epoch by peak-to-peak swing (P2P), spectral energy in the 0.10 to 0.50 Hz band (band-power), and the share of total power in that band (peak-sharpness), so that an irregular signal shows high P2P with low band-power and peak-sharpness.\n\nAveraged over each subject's whole night, none of these predicts overall MF1, and none of the Spearman correlations is reliably different from zero (P2P −0.21 [−0.44, +0.05], band-power +0.17 [−0.09, +0.41], peak-sharpness +0.16 [−0.10, +0.39]).\n\nWe then looked at Deep specifically, for reasons that precede this analysis. Our rebuttal reported that Light and Deep are the most frequent confusion pair among the errors that survive the timing tolerance (Table R2), and Deep is also where the two analyses above concentrate. A whole-night average would dilute an effect confined to one stage, so we recomputed the features over each subject's Deep epochs and replaced overall MF1 with how often those epochs are labelled Light.\n\n**Table R8.** Deep-restricted breathing regularity against how often the model misreads Deep as Light, both averaged within a subject. Spearman ρ with bootstrap 95% CIs over the 60 subjects with at least one true Deep epoch.\n\n| Feature | ρ with Deep-to-Light rate |\n| --- | --- |\n| P2P | +0.39 [+0.11, +0.62] |\n| Band-power | −0.53 [−0.72, −0.28] |\n| Peak-sharpness | −0.45 [−0.66, −0.19] |\n\nAll three point the same way, and the association is specific to one confusion. It appears on neither Deep-to-Wake nor Deep-to-REM, and the same features do not predict Wake, Light, or REM performance, so it is not a general effect of signal quality on staging. \n\nThe model misreads Deep as Light more often in subjects whose Deep-epoch breathing is less regular, that is, where Deep departs from the regular slow breathing typical of the stage. The mean Deep-to-Light rate is 45.7% in the lowest quartile of band-power against 11.3% in the highest, and the three correlations hold when restricted to the 53 subjects with at least 30 Deep epochs. Respiratory quality therefore does not affect staging in general, but it does bear on the one boundary where Deep is separated from Light.\n\n**(d) Respiratory events and OSA severity.** \n\nWe also compared epochs that contain a scored apnea or hypopnea against those that do not. Event epochs account for 20,121 of the 57,918 test epochs. Overall MF1 is lower during events, at 0.645 [0.604, 0.684] against 0.778 [0.750, 0.802], while accuracy is higher, at 0.843 [0.822, 0.861] against 0.784 [0.756, 0.808]. Both follow from event epochs being dominated by Light, so we decompose per stage using recall, which is computed over the true epochs of each stage and is unaffected by that difference.\n\nThe degradation runs along one axis. Deep recall falls from 0.703 to 0.314 (Δ = −0.389 [−0.553, −0.186]) while Light recall rises from 0.818 to 0.897, the signature of Deep epochs being relabelled as Light. Wake also falls, and REM shows no detectable effect despite carrying the highest event exposure of any stage at 47.4% of its epochs. The scope is bounded by the physiology, since respiratory events are markedly reduced in slow-wave sleep [3] and only 5.1% of Deep epochs carry one.\n\nStratifying by AHI separates this from disease burden. Event-free MF1 spans 0.051 across the four severity groups and is not ordered by severity, so severity itself does not shift average staging performance, though Appendix D.3 shows wider spread at higher AHI. The event-related drop is reliably below zero in Mild, Moderate, and Severe, so it is not confined to severe disease. A fuller version of this analysis, with the per-stage and per-severity tables, is in our response to Reviewer 4pmZ under [W4 / Q4]. \n\nThe final condition follows in the next comment.\n\n---\n\n[3] Ratnavadivel et al. Marked reduction in obstructive sleep apnea severity in slow wave sleep. JCSM 5(6), 2009."+ },+ "createdAt": "2026-08-01T13:56:38.212Z",+ "modifiedAt": "2026-11-19T17:17:16.978Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=wAIJeLxFY1",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/z8nopf5kq9.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/z8nopf5kq9.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Z8NoPf5Kq9",+ "replyTo": "t4d3aVbA0l",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results (2-2/2)",+ "comment": "**Table R7.** Per-stage F1 across adaptation settings, with Hospital A for reference. Adaptation uses 75 subjects at B and 76 at C.\n\n| Stage | B zero-shot | B SDM only | B both | C zero-shot | C SDM only | C both | A |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| Wake | 0.385 | 0.629 | 0.663 | 0.498 | 0.688 | 0.712 | 0.776 |\n| Light | 0.723 | 0.844 | 0.861 | 0.736 | 0.762 | 0.803 | 0.834 |\n| Deep | 0.249 | 0.357 | 0.300 | 0.254 | 0.388 | 0.438 | 0.674 |\n| REM | 0.494 | 0.665 | 0.724 | 0.426 | 0.556 | 0.638 | 0.823 |\n\nWake, Light, and REM all move substantially toward Hospital A at both sites. Light matches or exceeds it, at 0.861 against 0.834 at B and 0.803 at C, and accuracy at B reaches 0.800 against 0.804.\n\nThe residual sits mainly in Deep, which remains 0.374 below Hospital A at B and 0.236 below at C, and since MF1 weights all four stages equally, that stage accounts for most of the remaining MF1 gap. It is also the stage whose prevalence differs most across sites, covering 9.4% of epochs at Hospital A against 3.0% at B and 3.6% at C. That difference is a property of the cohorts rather than of the recordings, since both external sites draw on populations further from healthy sleep than Hospital A, and it leaves the adaptation sets with roughly a third as many Deep epochs per subject to calibrate on. The residual Deep errors go predominantly to Light at both sites, the Deep-to-Light confusion noted earlier, so this is an existing boundary under a much sparser Deep distribution rather than a failure specific to transfer.\n\nWhat fails to transfer is calibration to the acquisition setup and to the local stage distribution, and both respond to a modest amount of site-specific data rather than requiring a new cohort at the scale of Hospital A. Accuracy at B returns to Hospital A levels and the recovery is similar in size across two sites differing in camera, viewpoint, bed orientation, and referring department, so we do not read these results as indicating a modality-level limitation.\n\nA gap nonetheless remains at both sites. Training used a single site, and the external cohorts differ from it in patient population as well as in recording setup. Training across more sites and a wider range of populations and acquisition conditions is therefore likely to improve transfer on its own, and stronger domain adaptation is a further direction, since the settings used here are deliberately simple. We will report these results and both directions in §5.\n\n---\n\nWe hope these two sets of experiments address the concerns raised, and we are glad to run further analyses during the discussion period."+ },+ "createdAt": "2026-08-01T13:06:07.274Z",+ "modifiedAt": "2026-11-19T17:17:17.908Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=Z8NoPf5Kq9",+ "license": "CC-BY-4.0"+}
reviews/openreview/5wh6aa0lyo/notes/zbyqszqwml.json added
+++ b/reviews/openreview/5wh6aa0lyo/notes/zbyqszqwml.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "zbYQSZqWMl",+ "replyTo": "pVL4XvJiea",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer KeGQ",+ "content": {+ "title": "Thanks for the rebuttal",+ "comment": "Thanks for the authors to provide a detailed rebuttal. It addressed most of my concerns expect the \"Where errors concentrate\". However, I am satisfied with the current results and analysis. I believe that a bit more analysis into the errors would make the paper more interesting and inspiring."+ },+ "createdAt": "2026-08-01T00:04:58.209Z",+ "modifiedAt": "2026-11-19T17:17:17.357Z",+ "url": "https://openreview.net/forum?id=5WH6aA0LYO¬eId=zbYQSZqWMl",+ "license": "CC-BY-4.0"+}