Fine-tuning speech models on slow fMRI improves prediction for fast ECoG
Update NeurIPS 2026 submission KZUkyYypaw: 12 notes
@openreview[bot] · 2026-11-24 15:49 UTC · c446db2f599a ·
reviews/openreview/kzukyyypaw/notes/5xja6bgmxu.json added
+++ b/reviews/openreview/kzukyyypaw/notes/5xja6bgmxu.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "5XJa6bGMXu",+ "replyTo": "wQODRoHi6U",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "> Limitations: The source of the improvement is also not fully separated. Since the largest gains appear in auditory cortex, the effect may partly reflect better acoustic or phonetic encoding, not only higher-level language representation.\n\nOur above analyses (for W4/Q2) show that better acoustic and phonetic encoding only partly explain the gains in auditory cortex. Given AC has the highest performance even for the pretrained model, we believe this is primarily an effect of SNR. Electrodes that are more stimulus-driven (in this case, by an auditory stimulus) will be easier to predict. Unfortunately, there is no way to quantify SNR in this dataset because the stimulus was only presented once. (But even in fMRI, areas in AC have the highest SNR in this task.)"+ },+ "createdAt": "2026-08-01T01:38:21.951Z",+ "modifiedAt": "2026-11-19T17:07:26.837Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=5XJa6bGMXu",+ "license": "CC-BY-4.0"+}
reviews/openreview/kzukyyypaw/notes/6mincopgwp.json added
+++ b/reviews/openreview/kzukyyypaw/notes/6mincopgwp.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "6MinCoPGWP",+ "replyTo": "LxKcZoAaD6",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer WFZk",+ "content": {+ "comment": "Thank you for running the additional analyses. However, the new baselines raise further questions rather than strengthening the central claim. Since fine-tuning with alternative signals performs as well as or better than fMRI, it remains unclear if/what fMRI even contributes to improving ECoG prediction. Properly disentangling what fMRI contributes to ECoG transfer would require a deeper analysis than is possible during the rebuttal period. I therefore believe additional experiments are needed to verify the paper's central claims and will keep my current score."+ },+ "createdAt": "2026-08-03T04:59:46.583Z",+ "modifiedAt": "2026-11-19T17:07:26.946Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=6MinCoPGWP",+ "license": "CC-BY-4.0"+}
reviews/openreview/kzukyyypaw/notes/7pvxtkbff6.json added
+++ b/reviews/openreview/kzukyyypaw/notes/7pvxtkbff6.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "7PvxtkBFf6",+ "replyTo": "YFjptbtkMo",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "> S3/Q2/Q3: Can the authors comment on why they fMRI-tuned separate models for each participant? Could the LoRAs have been trained jointly for all participants? [...] How were these separate models reconciled when making ECoG predictions?\n\nWe did this to mirror the setup of Vattikonda et al. (2025) and Moussa et al. (2024). All metrics, including ECoG performance, were calculated separately for each fMRI-tuned model (one model per fMRI participant), and we report the average across fMRI participants.\n\nfMRI-tuning on responses from multiple participants is feasible. To show this, we have additionally fMRI-tuned `whisper-large-v3` on the Courtois NeuroMod dataset by fine-tuning it simultaneously on all 6 participants’ data. We evaluate its representations on the “Podcast” ECoG dataset and find performance increases from 0.0683 to 0.0702 (2.8% improvement) after averaging across electrodes. In addition to using multiple fMRI-tuning subjects, this setup differs in two key ways from our original setup. First, the starting model is trained for word recognition instead of a self-supervised objective (WavLM). Second, the responses in NeuroMod are to audiovisual stimuli rather than purely audio (LeBel et al.). Despite all these differences, the fMRI-tuned Whisper model still improves at predicting ECoG.\n\n> Q4: Please consider showing time courses.\n\nAs we are not allowed to include links to plots in our responses, we will include predicted timecourses in a revised version of the manuscript."+ },+ "createdAt": "2026-07-31T12:47:57.501Z",+ "modifiedAt": "2026-11-19T17:07:26.970Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=7PvxtkBFf6",+ "license": "CC-BY-4.0"+}
reviews/openreview/kzukyyypaw/notes/95konl837t.json added
+++ b/reviews/openreview/kzukyyypaw/notes/95konl837t.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "95kOnl837t",+ "replyTo": "1kpglPbvbN",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Additional results and clarifications",+ "comment": "> Q1/W2: All experiments are performed using WavLM. Could the authors replicate the main analyses using another pretrained speech or language model to demonstrate that the observed improvements are not specific to this architecture?\n\nWe have additionally fMRI-tuned `whisper-large-v3` on the Courtois NeuroMod dataset, and we evaluate its representations on the “Podcast” ECoG dataset. After fMRI-tuning, performance increases from 0.0683 to 0.0702 (2.8% improvement) after averaging across electrodes. This setup differs in several key ways from our original setup. First, the starting model is trained for word recognition instead of a self-supervised objective (WavLM), and is therefore more lexical. Second, the model is simultaneously fine-tuned on multiple fMRI subjects instead of one. Third, the responses in NeuroMod are to audiovisual stimuli rather than purely audio (LeBel et al.). Despite these substantial ablations, the fMRI-tuned Whisper model still improves at predicting ECoG.\n\n\n> Q2a/W3: The current comparisons do not isolate whether the improvements arise specifically from fMRI-tuning or simply from additional fine-tuning. Could the authors include additional baselines as mentioned above?\n\nWe fine-tuned additional WavLM models on stimulus-only features: LLaMA hidden states (semantics), wordrate (acoustic), and articulatory features (phonetic). We also fine-tuned models on fMRI responses shuffled in 10-TR blocks to show that the temporal structure in the fMRI responses is necessary. We report the results below:\n\n\n| Model | Mean encoding perf. ($\\rho$) | SEM |\n|:--------------------|-------------------------------:|---------:|\n| fMRI-tuned | 0.08107 | 0.003183 |\n| shuffled-fMRI-tuned | 0.07233 | 0.002976 |\n| LLaMA-tuned | 0.08822 | 0.003248 |\n| Word rate-tuned | 0.08739 | 0.003228 |\n| Articulation-tuned | 0.08665 | 0.003185 |\n| Pretrained | 0.06955 | 0.002559 |\n\nThe shuffled-fMRI-tuned models show a small improvement over the pretrained model, but are substantially worse than the normal fMRI-tuned models. The three stimulus-tuned models do perform well, but perhaps for different reasons. First, LLaMA hidden states are a noiseless semantic signal. in contrast with fMRI. Thus, they are a better semantic teacher for the WavLM model. Word rate is a primarily acoustic signal that would be useful for predicting auditory areas, but this speech feature may not be directly represented in the WavLM model. Hence, a small amount of fine-tuning on this signal would improve auditory performance. We believe the same is true for articulatory features.\n\nWe also note that the wordrate- and articulation- tuned models needed minimal training before early stopping, only 2 epochs, compared to a minimum 8 for all other models. This further supports the idea that these gains come from the features being simple, noiseless signals, in comparison to the braintuning, which is noisier but also is able to introduce more complex features.\n\n\n> Q3: The fMRI and ECoG datasets contain different stimuli. How semantically or conceptually similar are the two stimulus sets? A simple visualization (e.g., MDS or t-SNE of the stimuli in WavLM embedding space) would help assess the degree of overlap and the generalizability of the proposed approach. Especially, given that each ECoG participant contributes only approximately 30 minutes of data.\n\nWhile the stimuli in the two datasets are qualitatively similar (they are both natural stories), the two biggest differences are that the fMRI stimuli (_Moth Radio Hour_) are monologues with noisier audio quality, whereas the ECoG stimulus (_This American Life_) is a dialogue with clean audio. Because the ECoG stimulus is only a single story (whereas the fMRI has ~100 stories), it spans a much smaller semantic space.\n\nWe evaluated the degree of overlap of the fMRI and ECoG stimuli by computing the Wasserstein distance of their WavLM embeddings from the pretrained model. We first reduced the features to 50 PCs for computational reasons. The Wasserstein distance between the two sets of stimuli was 7.634, and this was larger than two within-dataset controls. The distance between two stories from the fMRI dataset was on average 5.957, and the distance between the first and second halves of the ECoG stimulus was 5.280. These suggest that the stimuli do occupy distinct parts of the latent space.\n\nSince we are not allowed to give links, we cannot provide any visualizations of the latent space. With t-SNE, the distribution of the stimuli appears to be mostly disjoint. We will include plots that show the projected latent space in the final manuscript."+ },+ "createdAt": "2026-07-31T23:32:29.962Z",+ "modifiedAt": "2026-11-19T17:07:26.967Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=95kOnl837t",+ "license": "CC-BY-4.0"+}
reviews/openreview/kzukyyypaw/notes/eke1aw9fj5.json added
+++ b/reviews/openreview/kzukyyypaw/notes/eke1aw9fj5.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Eke1aw9Fj5",+ "replyTo": "jR7PZgCCAv",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer ptyU",+ "content": {+ "comment": "Thank you for the detailed response and for running the additional analyses. I found the shuffled-fMRI control, the FIR analysis, the lower-level feature controls, and the patient-level results useful. They strengthen the paper, but they do not fully resolve my main concern about what is driving the improvement.\n\nThe shuffled-fMRI result suggests that temporal alignment matters, since the fMRI-tuned model performs better than the shuffled-fMRI model. However, the LLaMA-tuned, word-rate-tuned, and articulation-tuned models all achieve numerically higher mean scores than the fMRI-tuned model. This makes the interpretation less straightforward. The new results show that fMRI tuning can help, but they also suggest that simpler stimulus-based targets may produce comparable or even larger gains. The authors explain that these targets may be cleaner and less noisy than fMRI, which is plausible, but this still does not show a clear benefit that is specific to fMRI supervision. A direct statistical comparison between these conditions would also be helpful.\n\nI also still have concerns about lag selection. The FIR analysis is useful because the fMRI-tuned model continues to outperform the pretrained model without choosing the best lag on the test set. At the same time, the stimulus-only models again perform slightly better than the fMRI-tuned model in this analysis. In addition, the main single-lag results still rely on selecting the best lag using test-set performance, so those values may be somewhat optimistic.\n\nThe Whisper result gives some evidence that the effect is not limited to WavLM, but the improvement is only 2.8%, and no uncertainty estimate or significance test is reported. It is also only one additional model. The questions about other WavLM layers, HuBERT, and wav2vec 2.0 therefore remain open.\n\nI appreciate the amount of additional work in the response. Still, some of the new results are weaker than expected, and the stimulus-only baselines make the claim about the specific value of fMRI supervision less convincing. For this reason, I am keeping my assessment unchanged."+ },+ "createdAt": "2026-08-02T13:23:25.926Z",+ "modifiedAt": "2026-11-19T17:07:26.790Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=Eke1aw9Fj5",+ "license": "CC-BY-4.0"+}
reviews/openreview/kzukyyypaw/notes/gnp9yh0uhg.json added
+++ b/reviews/openreview/kzukyyypaw/notes/gnp9yh0uhg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Gnp9Yh0UhG",+ "replyTo": "IbLRZnrqxT",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Area Chair 8xyD",+ "content": {+ "comment": "Thank you to the authors for providing detailed responses!\n\nDear reviewers, please make sure to read the authors’ responses and participate in the discussion so that the authors have an opportunity to address any remaining questions."+ },+ "createdAt": "2026-08-01T07:11:35.833Z",+ "modifiedAt": "2026-11-19T17:07:26.814Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=Gnp9Yh0UhG",+ "license": "CC-BY-4.0"+}
reviews/openreview/kzukyyypaw/notes/iblrznrqxt.json modified
+++ b/reviews/openreview/kzukyyypaw/notes/iblrznrqxt.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 8xyD","content": {- "metareview": "The authors propose an innovative approach for ECoG language encoding models using fMRI, despite the fact that fMRI has low temporal resolution. They use fMRI responses to spoken narratives to fine-tune WavLM Base+ and then use its speech representations to predict ECoG responses.\n\nThe reviewers found the problem important and the approach interesting and were overall quite positive, but with several important concerns that the authors could address during the rebuttal period, including the fact that the evaluation is limited to a single speech model and lacks additional baselines such as stimulus-only tuning and that the ECoG model was fairly simple (ridge regression) and evaluated only on a single dataset."+ "metareview": "The authors propose an innovative approach for ECoG language encoding models using fMRI, despite the fact that fMRI has low temporal resolution. They use fMRI responses to spoken narratives to fine-tune WavLM Base+ and then use its speech representations to predict ECoG responses.\n\nThe reviewers found the problem important and the approach interesting and were overall quite positive, but with several important concerns that the authors could address during the rebuttal period, including the fact that the evaluation is limited to a single speech model and lacks additional baselines such as stimulus-only tuning and that the ECoG model was fairly simple (ridge regression) and evaluated only on a single dataset.",+ "final_justification": "The authors have provided a detailed rebuttal, and while some concerns remain, all of the reviewers are leaning towards acceptance. The remaining concerns are primarily regarding the broader interpretation of the findings, which suggests that fMRI tuning may produce “more brain-like representations” and the conclusion that the results provide “strong evidence that brain-like representations are highly modality invariant”."},"createdAt": "2026-07-23T00:07:53.421Z",- "modifiedAt": "2026-11-18T15:23:23.950Z",+ "modifiedAt": "2026-11-19T05:02:08.005Z","url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=IbLRZnrqxT","license": "CC-BY-4.0"}
reviews/openreview/kzukyyypaw/notes/lxkczoaad6.json added
+++ b/reviews/openreview/kzukyyypaw/notes/lxkczoaad6.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "LxKcZoAaD6",+ "replyTo": "95kOnl837t",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We additionally wanted to contextualize our answer to Q4:\n\n> Q4: Is Figure 3 averaged across participants? The y-axis values appear very small; is this expected?\n\nYes, Figure 3 is averaged across all fMRI-tuning participants, as well as all ECoG electrodes. The values are small, but correspond to a 1.5% reduction in residual power below the fMRI Nyquist rate, and 0.6% above it. We note that this is a 1.5% reduction in total residual power, which includes a dominant term of unexplainable but difficult to estimate noise power. For fMRI, noise power is easily over half of the total signal. This is a conservative estimate when compared to faster ECoG, so in comparison this 1.5% reduction is closer to at least a 3-5% reduction in the unexplained-but-explainable residual power."+ },+ "createdAt": "2026-07-31T23:32:44.535Z",+ "modifiedAt": "2026-11-19T17:07:27.042Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=LxKcZoAaD6",+ "license": "CC-BY-4.0"+}
reviews/openreview/kzukyyypaw/notes/osxnrtvepg.json added
+++ b/reviews/openreview/kzukyyypaw/notes/osxnrtvepg.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "OsxnrTvEpG",+ "replyTo": "FS3R91d69t",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Addressing the remaining questions",+ "comment": "> W1/Q1: Do the results depend on WavLM layer 9? Would other WavLM layers, HuBERT, Whisper, or wav2vec 2.0 show similar fMRI-to-ECoG transfer effects?\n\nWe chose layer 9 of WavLM because it had the highest baseline fMRI performance in that model, and we do not claim that the choice of layer or model is critical for our results.\n\nWe have additionally fMRI-tuned `whisper-large-v3` on the Courtois NeuroMod dataset, and we evaluate its representations on the “Podcast” ECoG dataset. After fMRI-tuning, performance increases from 0.0683 to 0.0702 (2.8% improvement) after averaging across electrodes. This setup differs in several key ways from our original setup. First, the starting model is trained for word recognition instead of a self-supervised objective (WavLM). Second, the model is simultaneously fine-tuned on multiple fMRI subjects instead of one. Third, the responses in NeuroMod are to audiovisual stimuli rather than purely audio (LeBel et al.). Despite all these differences, the fMRI-tuned Whisper model still improves at predicting ECoG.\n\n> W2: The baselines are still not sufficient. The main comparison is between fMRI-tuned WavLM and pretrained WavLM, but this does not rule out the possibility that ordinary speech-related fine-tuning, regularization, or extra speech exposure could lead to similar gains. Useful baselines would include stimulus-only tuning, BigSLM target tuning, phoneme tuning, or semantic tuning.\n\nWe fine-tuned additional WavLM models on stimulus-only features: LLaMA hidden states (semantics), wordrate (acoustic), and articulatory features (phonetic). We also fine-tuned models on fMRI responses shuffled in 10-TR blocks to show that the temporal structure in the fMRI responses is necessary. We report the results below:\n\n\n| Model | Mean encoding perf. ($\\rho$) | SEM |\n|:--------------------|-------------------------------:|---------:|\n| fMRI-tuned | 0.08107 | 0.003183 |\n| shuffled-fMRI-tuned | 0.07233 | 0.002976 |\n| LLaMA-tuned | 0.08822 | 0.003248 |\n| Word rate-tuned | 0.08739 | 0.003228 |\n| Articulation-tuned | 0.08665 | 0.003185 |\n| Pretrained | 0.06955 | 0.002559 |\n\nThe shuffled-fMRI-tuned models show a small improvement over the pretrained model, but are substantially worse than the normal fMRI-tuned models. The three stimulus-tuned models do perform well, but perhaps for different reasons. First, LLaMA hidden states are a noiseless semantic signal. in contrast with fMRI. Thus, they are a better semantic teacher for the WavLM model. Word rate is a primarily acoustic signal that would be useful for predicting auditory areas, but this speech feature may not be directly represented in the WavLM model. Hence, a small amount of fine-tuning on this signal would improve auditory performance. We believe the same is true for articulatory features.\n\nWe also note that the wordrate- and articulation- tuned models needed minimal training before early stopping, only 2 epochs, compared to a minimum 8 for all other models. This further supports the idea that these gains come from the features being simple, noiseless signals, in comparison to the braintuning, which is noisier but also is able to introduce more complex features (see response to W4/Q2).\n\n> W3: The ECoG temporal model is relatively simple. The authors use single-lag ridge regression because of computational cost, rather than a full FIR model. This choice is understandable, but it may not fully capture language responses at multiple time scales in ECoG.\n\nWe shared your concern that the simplicity of our temporal model for ECoG may not be expressive enough to capture all possible filters, but empirically, this does not appear to be an issue when evaluating the fMRI-tuned models. We fit 40-delay FIR models ($t=50$ ms to $t=2$ s) models on WavLM features after using PCA to reduce them to 100 dimensions. We show their performance here:\n\n| Model | Mean encoding perf. ($\\rho$) | SEM | % improvement vs. pretrained |\n|:-------------------|-------------------------------:|---------:|-------------------------------:|\n| fMRI-tuned | 0.05772 | 0.002968 | 36.59 |\n| LLaMA-tuned | 0.06077 | 0.003084 | 43.79 |\n| Word rate-tuned | 0.05907 | 0.003113 | 39.78 |\n| Articulation-tuned | 0.06084 | 0.003022 | 43.98 |\n| Pretrained | 0.04226 | 0.002352 | 0 |\nWith a full FIR model, fMRI-tuning outperforms the pretrained model by a larger margin than for the single-delay models. Note that these values cannot be directly compared to those from single-delay models from the rest of the paper. For those models, we take the maximum test performance over lags, uniformly biasing the performance upwards (see below, “Q4”). In these FIR models, we do not use the test set during model fitting."+ },+ "createdAt": "2026-08-01T01:32:27.068Z",+ "modifiedAt": "2026-11-19T17:07:26.847Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=OsxnrTvEpG",+ "license": "CC-BY-4.0"+}
reviews/openreview/kzukyyypaw/notes/ozjac8yttf.json added
+++ b/reviews/openreview/kzukyyypaw/notes/ozjac8yttf.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ozjac8yTTf",+ "replyTo": "6MinCoPGWP",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the Reviewer WFZk for their reply, and we want to address one element of their response using new results.\n\n> Since fine-tuning with alternative signals performs as well as or better than fMRI, it remains unclear if/what fMRI even contributes to improving ECoG prediction.\n\nWe want to emphasize that while fine-tuning on other sources can also improve encoding, our new variance partitioning analysis clearly demonstrates that braintuning provides an orthogonal component of improvement that is not captured by these other data sources. \n\nWe evaluated whether adding concatenating the WavLM features with one of the baseline features improved ECoG performance. We used FIR models (and reduced WavLM features) because the two sets of features may perform best at different delays. In the table below, the first row shows the performance of the baseline feature only. The next two rows show the performance of the pretrained and fMRI-tuned models by themselves (column 1), or after they’ve been concatenated with one baseline feature (columns 2-4). The final row shows the performance gain of the joint fMRI-tuned+baseline model relative to the baseline-only model.\n\n| Model | WavLM only | w/ envelope | w/ spectrogram | w/ phonetic |\n|:--------------|:-------------------|:-------------------|:-------------------|:-------------------|\n| Baseline only | N/A | 0.04034 ± 0.002177 | 0.04591 ± 0.002427 | 0.03722 ± 0.002 |\n| Pretrained WavLM | 0.04226 ± 0.002352 | 0.05334 ± 0.002874 | 0.06289 ± 0.003025 | 0.05205 ± 0.002815 |\n| fMRI-tuned WavLM | 0.05772 ± 0.002968 | 0.05895 ± 0.003048 | 0.0666 ± 0.003136 | 0.05808 ± 0.002987 |\n| **fMRI-tuned w/ baseline $-$ baseline-only** | N/A | **0.01861 ± 0.001363** | **0.02069 ± 0.0009996** | **0.02086 ± 0.001263** |\n\nThe fMRI-tuned models outperform all three baselines individually, and importantly, they explain an orthogonal component of the response relative to the baselines. For example, concatenating the fMRI-tuned representations with the speech envelope improved performance by 0.1861, indicating that the fMRI-tuning improved the models in non-acoustic ways. Because gains are also seen over the spectral and phonetic features, the fMRI-tuned models are better in ways not explained by any of these baselines."+ },+ "createdAt": "2026-08-03T09:55:37.659Z",+ "modifiedAt": "2026-11-19T17:07:26.760Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=ozjac8yTTf",+ "license": "CC-BY-4.0"+}
reviews/openreview/kzukyyypaw/notes/wqodrohi6u.json added
+++ b/reviews/openreview/kzukyyypaw/notes/wqodrohi6u.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "wQODRoHi6U",+ "replyTo": "OsxnrTvEpG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "> W4/Q2: Is the improvement mainly acoustic, phonetic, or semantic? Does fMRI-tuned WavLM still help after controlling for speech envelope, spectrogram, or phoneme-level features?\n\nTo control for simpler speech features, we evaluated whether adding concatenating the WavLM features with one of these features improved ECoG performance. We used FIR models (and reduced WavLM features) because the two sets of features may perform best at different delays. In the table below, the first row shows the performance (mean $\\pm$ SEM) of the baseline feature only. The next two rows show the performance of the pretrained and fMRI-tuned models by themselves (column 1), or after they’ve been concatenated with one baseline feature (columns 2-4).\n| Model | WavLM only | w/ envelope | w/ spectrogram | w/ phonetic |\n|:--------------|:-------------------|:-------------------|:-------------------|:-------------------|\n| Baseline only | N/A | 0.04034 ± 0.002177 | 0.04591 ± 0.002427 | 0.03722 ± 0.002 |\n| Pretrained WavLM | 0.04226 ± 0.002352 | 0.05334 ± 0.002874 | 0.06289 ± 0.003025 | 0.05205 ± 0.002815 |\n| fMRI-tuned WavLM | 0.05772 ± 0.002968 | 0.05895 ± 0.003048 | 0.0666 ± 0.003136 | 0.05808 ± 0.002987 |\n\nThe fMRI-tuned model outperforms all three baselines. Joint WavLM-baseline models have higher performance than the models do separately, indicating that they explain partially disjoint sets of the response. For all baselines, joint models using the fMRI-tuned WavLM improve over the joint models using the pretrained WavLM. This is evidence that fMRI-tuning adds information that is orthogonal to each of these low-level speech features.\n\nThe marginal gain of adding the baseline feature, however, is less for the fMRI-tuned model (e.g. 0.05772 alone vs. 0.0666 w/ spectrogram) than for the pretrained model (0.04226 alone vs. 0.06289 w/ spectrogram). Thus, there is _some_ overlap between the baselines and what fMRI-tuning learns, in addition to orthogonal component.\n\n> W5: The ECoG evaluation uses only one Podcast dataset. The paper would be stronger with more detailed per-patient results, an analysis of how electrode coverage affects the findings, or validation on another ECoG dataset. [From Limitations:] Patient-level results, mixed-effects analysis, or patient-wise bootstrap would make the statistical support stronger.\n\nAs far as we know, the “Podcast” dataset is the only public ECoG dataset that uses auditory stimuli. We would be happy to extend our analyses to another dataset to demonstrate robustness.\n\nWe agree that our findings can depend on electrode coverage, which greatly varies across patients. We show the coverage and performance change for each patient’s electrodes in the Appendix (Fig. 6). Here, we quantify the mean performance (across electrodes) for each ECoG patient, before and after fMRI-tuning. We also compute paired two-sided $t$-tests across electrodes within each subject.\n| Patient | fMRI-tuned | Pre-trained | $p$-val |\n|-----------|-------------|--------------|----------|\n| 01 | **0.096** | 0.0781 | 9.94e-10 |\n| 02 | **0.0603** | 0.0513 | 1.61e-07 |\n| 03 | **0.0902** | 0.0741 | 3.42e-19 |\n| 04 | **0.0839** | 0.0707 | 6.5e-07 |\n| 05 | 0.026 | **0.0296** | 0.00342 |\n| 06 | **0.104** | 0.0885 | 3e-13 |\n| 07 | 0.0702 | **0.0757** | 0.061 |\n| 08 | **0.0976** | 0.0803 | 1.28e-06 |\n| 09 | **0.0958** | 0.0764 | 2.64e-22 |\n\nOf the nine subjects, only two do not improve after fMRI-tuning. One of these has poor performance even for the pretrained model, suggesting poor data quality. We will update the manuscript with the quantitative results above.\n\nFollowing your suggestion, we also analyzed patient-level effects using linear mixed effects with the model type (pretrained or fMRI-tuned) as a fixed effect and subject-specific random intercepts. fMRI-tuned had significantly higher performance than the pretrained models with $\\beta = 0.0117$, SE = 0.0043, 95% CI [0.0034, 0.0201], $p=0.006$.\n\n> Q3: [...] Should the downsampled-fMRI result be interpreted as slow-to-fast transfer, or as robustness to low-frequency or denoised fMRI supervision?\n\nThe downsampled-fMRI-tuned result is evidence of slow-to-fast generalization, but also that what is being learned (semantics) is captured in the lowest-frequency signals.\n\n---\n\nQ4, and Q5/W6 were answered in the original rebuttal."+ },+ "createdAt": "2026-08-01T01:37:46.599Z",+ "modifiedAt": "2026-11-19T17:07:26.836Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=wQODRoHi6U",+ "license": "CC-BY-4.0"+}
reviews/openreview/kzukyyypaw/notes/yfjptbtkmo.json added
+++ b/reviews/openreview/kzukyyypaw/notes/yfjptbtkmo.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "YFjptbtkMo",+ "replyTo": "O4BS1zBKMP",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Replacement rebuttal",+ "comment": "We answer the remaining questions from Reviewer aas2 here, and we expand upon our previous answers. For that reason, please disregard the original \"Rebuttal by Authors\".\n\n> S1/Q1: This work convinces me that fine tuning on fMRI data is helpful for predicting ECoG, and that improvements are not limited to long time scales. I find it difficult to put these improvements in context, however. It would help to know how this improvement compares to a noise ceiling and to the variation you'd see from simply swapping in a different DNN. My view on the significance of these results depends on how substantial the improvement is versus the noise ceiling.\n\nThis is an important point, but unfortunately, there is no way to quantify the noise ceiling in this dataset because the stimulus was only presented once. To provide more context for our results we fine-tuned new WavLM models on stimulus-only features: LLaMA hidden states (semantics), wordrate (acoustic), and articulatory features (phonetic). We also fine-tuned models on fMRI responses shuffled in 10-TR blocks to show that the temporal structure in the fMRI responses is necessary. We report the results below:\n\n\n| Model | Mean encoding perf. ($\\rho$) | SEM |\n|:--------------------|-------------------------------:|---------:|\n| fMRI-tuned | 0.08107 | 0.003183 |\n| shuffled-fMRI-tuned | 0.07233 | 0.002976 |\n| LLaMA-tuned | 0.08822 | 0.003248 |\n| Word rate-tuned | 0.08739 | 0.003228 |\n| Articulation-tuned | 0.08665 | 0.003185 |\n| Pretrained | 0.06955 | 0.002559 |\n\nThe shuffled-fMRI-tuned models show a small improvement over the pretrained model, but are substantially worse than the normal fMRI-tuned models. The three stimulus-tuned models do perform well, but perhaps for different reasons. First, LLaMA hidden states are a noiseless semantic signal. in contrast with fMRI. Thus, they are a better semantic teacher for the WavLM model. Word rate is a primarily acoustic signal that would be useful for predicting auditory areas, but this speech feature may not be directly represented in the WavLM model. Hence, a small amount of fine-tuning on this signal would improve auditory performance. We believe the same is true for articulatory features.\n\nWe also note that the wordrate- and articulation- tuned models needed minimal training before early stopping, only 2 epochs, compared to a minimum 8 for all other models. This further supports the idea that these gains come from the features being simple, noiseless signals, in comparison to the braintuning, which is noisier but also is able to introduce more complex features.\n\nWe have additionally fMRI-tuned a different backbone — `whisper-large-v3` — on the Courtois NeuroMod dataset, and we evaluate its representations on the “Podcast” ECoG dataset. After fMRI-tuning, performance increases from 0.0683 to 0.0702 (2.8% improvement) after averaging across electrodes. See the question below about “separate models for each participant” for more details about this model.\n\n> S2: The authors show that the improvements are not limited to the coarse time scale of fMRI. I’d like to see predicted vs. measured ECoG time courses, not just correlation. If fMRI tuning substantially improves alignment of fine-scale dynamics (which, in my experience, are usually poorly captured), that would increase my appraisal of the significance.\n\nWe believe the spectrum of the residual (Fig. 3) demonstrates that we do improve the alignment of fine-scale dynamics. The residual decreases in the highest frequency bands, which necessarily means that we improve the alignment at those scales. We will also show predicted timecourse plots in the final manuscript."+ },+ "createdAt": "2026-07-31T12:47:03.957Z",+ "modifiedAt": "2026-11-19T17:07:27.000Z",+ "url": "https://openreview.net/forum?id=KZUkyYypaw¬eId=YFjptbtkMo",+ "license": "CC-BY-4.0"+}