BioMicroAgents: A Co-evolutionary Multi-Agent Framework for High-Fidelity Biomicroscopy Imaging
Update NeurIPS 2026 submission 2IBxEPvy2X: 13 notes
@openreview[bot] · 2026-11-24 15:45 UTC · 2643d6585792 ·
reviews/openreview/2ibxepvy2x/notes/8uvlv40yed.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/8uvlv40yed.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "8uvLV40YEd",+ "replyTo": "Rt1sFGfDG8",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer moa1",+ "content": {+ "comment": "Thanks for your response. \n1. First, the response still does not clearly separate the paper’s novel contribution from orchestration of existing components. The system combines agents, RAG, memory, segmentation, expert models, image-editing models, reward models, rollback, and RL/co-evolution, but it remains difficult to identify which component is scientifically essential.\n2. Second, the segmentation/reward concern is not adequately addressed. The response says a fine-tuned SAM3 model is used and can be replaced through a Pydantic interface, but this does not answer the key issue: if segmentation is wrong on OOD microscopy data, the MicroAuthenticator reward may guide the co-evolution process in the wrong direction.\n\nWhat's more, how the SAM3 segmented objects are classified to match the user prompt. Only works when the whole image contains one class of object, such as cells. May not work in a complicated bioimage such as HE. \n\n3. Third, reproducibility remains a major issue. The response says prompts are in the appendix and code will be released upon acceptance, but the full system depends on more than codes such as RAG content, memory templates, and co-evolution details.\n4. Fourth, the added human-evaluation results are potentially useful but not enough in their current form. The design, statistical testing, task details, expert instructions, image sampling protocol, and blinding/randomization are not sufficiently described.\n\nI would like to keep my score now."+ },+ "createdAt": "2026-07-31T03:09:10.266Z",+ "modifiedAt": "2026-11-19T17:19:28.307Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=8uvLV40YEd",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/d5pklpqvro.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/d5pklpqvro.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "D5PkLPqVrO",+ "replyTo": "beZIC48XdV",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Experimental design for human expert evaluation",+ "comment": "The experimental setup is summarized in the table below. All participating experts had relevant professional experience or held a doctoral degree in a related field. None were authors of this paper, and they had no prior knowledge of the methods evaluated in this study. \n\n**Turing Test**: Experts were asked to determine whether each image was AI-generated.\n\n**Scoring evaluation**: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.\n\n(1) Quality (Image Quality)\n\nEvaluate only the visual quality of the image, without considering whether the biological content depicted is accurate or realistic. The assessment should mainly consider noise, blur caused by camera defocus or motion, insufficient illumination, inadequate contrast, and low resolution.\n- **Score 1 — Poor:** The image contains severe noise, blur, insufficient illumination, or inadequate resolution. Key structures are difficult to identify, substantially hindering observation and evaluation.\n- **Score 2 — Fair:** The image has noticeable quality problems. Some structures remain identifiable, but noise, blur, illumination, or resolution issues still significantly affect observation.\n- **Score 3 — Moderate:** The image is generally interpretable, and the main structures are reasonably clear. However, some noise, blur, uneven illumination, or loss of detail remains.\n- **Score 4 — Good:** The image has good clarity and contrast. Only minor noise, blur, or resolution limitations are present, without affecting the observation of major structures and details.\n- **Score 5 — Excellent:** The image is clear and rich in detail, with appropriate illumination and contrast. There is almost no perceptible noise, blur, or resolution-related degradation.\n\n(2) Artifact\n\nEvaluate whether the image contains artifacts, unexpected textures, excessive enhancement, or excessive denoising that may interfere with observation and assessment.\n- **Score 1 — Severe:** The image contains numerous artifacts or abnormal textures that interfere with evaluation, or shows severe over-enhancement or over-denoising, resulting in obvious structural distortion.\n- **Score 2 — Noticeable:** The image contains multiple artifacts or abnormal textures that interfere with evaluation. Enhancement or denoising has affected the reliability of some structures.\n- **Score 3 — Moderate:** The image contains some artifacts, abnormal textures, enhancement, or denoising that may affect evaluation. However, some of these issues are also difficult to distinguish in the original image based on the evaluator’s knowledge and experience.\n- **Score 4 — Minor:** The image contains essentially no obvious artifacts or abnormal textures that affect evaluation. Any enhancement or denoising is difficult to detect, and the results are generally consistent with the evaluator’s knowledge, experience, and personal assessment.\n- **Score 5 — No noticeable issues:** The image contains no identifiable artifacts, abnormal textures, or inappropriate processing. The enhancement and denoising results are highly consistent with the evaluator’s relevant knowledge and experience.\n\n(3) Constructiveness (Usefulness for Biological Assessment)\n\nEvaluate whether the image facilitates biological assessment or further research, including but not limited to cell counting, cell segmentation, morphological observation, and quantitative analysis.\n- **Score 1 — Not useful at all:** The image does not support biological assessment and may even be misleading or make interpretation more difficult.\n- **Score 2 — Mostly not useful:** The image provides no noticeable improvement compared with direct observation of the original image.\n- **Score 3 — Somewhat useful:** The image improves the visibility of some structures or details and provides limited assistance for biological observation or analysis.\n- **Score 4 — Highly useful:** The image clearly presents most structures and details relevant to the assessment and facilitates cell counting, segmentation, morphological observation, or other biological analyses.\n- **Score 5 — Extremely useful:** The image substantially improves the visibility and interpretability of relevant structures and details, reliably supporting cell counting, segmentation, quantitative analysis, or other further analyses.\n\n**Swap experiment**: Experts performed cell-counting tasks on different slides, and their counts were compared with the ground-truth values. To prevent prior exposure to the original slides from influencing the evaluation of the AI-processed slides, the experts were divided into two groups: Group A counted cells in the original images, while Group B counted cells in the AI-processed images. The two groups then switched tasks and performed cell counting on another set of previously unseen slides."+ },+ "createdAt": "2026-07-28T15:17:42.851Z",+ "modifiedAt": "2026-11-19T17:19:28.437Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=D5PkLPqVrO",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/e3t2j10et1.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/e3t2j10et1.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "e3t2j10eT1",+ "replyTo": "Rt1sFGfDG8",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Further Questions (Part 1)",+ "comment": "Thank you for your response. We would like to further address the remaining concerns:\n\n1. Our key innovation lies in modeling biological microscopy imaging as a collaborative multi-agent process that emulates the observation, verification, and adjustment workflow followed by human experts. Through our biological-fidelity-oriented multi-reward reinforcement learning mechanism and memory mechanism, the different components can co-evolve throughout the processing procedure. We believe that our ablation studies and comparative experiments, including comparisons with individual expert models, independently validate the effectiveness of both the proposed mechanisms and the multi-agent architecture.\n \n2. We maintain that the segmentation model does not constitute a bottleneck for the capability of the overall framework. First, most instance segmentation models, such as SAM3, are capable of segmenting multiple object categories and exhibit general foreground recognition ability[1,2]. Moreover, the effectiveness of using segmentation models to improve downstream task performance or serve as a verifier has already been demonstrated in many previous studies [3,4,5]. Second, the verifier is applied under the same evaluation setting before and after image processing, thereby ensuring the consistency and stability of the comparison. The supplementary experiments further support the generalizability of our framework, as both Masson-stained images and murine glenohumeral joint tissues were unseen during training.\n \n3. The prompts for all components, particularly the system prompts, are presented in the figures in **Appendix C**. We apologize that, due to the space limitation, we are unable to reproduce the full prompt text directly here.\n \n4. Regarding the human study, we provided the detailed experimental design in our response to the second comment. We have also supplemented the evaluation with additional statistical tests and implementation details, as described in Part 2.\n\n[1] Wang H, Chen Q, Yan C, et al. Object-centric video question answering with visual grounding and referring[C]//2025 IEEE/CVF International Conference on Computer Vision (ICCV). IEEE, 2025: 22274-22284.\n\n[2] Zhang Q, Liu X, Li W, et al. Distilling semantic priors from sam to efficient image restoration models[C]//2024 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR). IEEE, 2024: 25409-25419.\n\n[3] Zhang M, Yin J, Zeng P, et al. TSCnet: A text-driven semantic-level controllable framework for customized low-light image enhancement[J]. Neurocomputing, 2025, 625: 129509.\n\n[4] Li S, Liu M, Zhang Y, et al. Sam-deblur: Let segment anything boost image deblurring[C]//ICASSP 2024-2024 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP). IEEE, 2024: 2445-2449.\n\n[5] Liu S, Ma J, Sun L, et al. Instructrestore: Region-customized image restoration with human instructions[J]. Advances in Neural Information Processing Systems, 2026, 38: 44948-44968."+ },+ "createdAt": "2026-08-02T09:59:00.397Z",+ "modifiedAt": "2026-11-19T17:19:28.066Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=e3t2j10eT1",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/eq0bjjgwrw.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/eq0bjjgwrw.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Eq0BjjgWRw",+ "replyTo": "VMZbk6rV5f",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 8Et7",+ "content": {+ "comment": "The authors have addressed my main concerns and provided helpful clarifications. I appreciate your careful engagement with the review process."+ },+ "createdAt": "2026-07-31T08:33:46.870Z",+ "modifiedAt": "2026-11-19T17:19:28.259Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=Eq0BjjgWRw",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/fuewxmntko.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/fuewxmntko.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "fUEwXMnTKo",+ "replyTo": "Yw7ipy06YI",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you very much for your careful review of our paper and your constructive feedback. Regardless of the outcome, we will continue to improve our work. We wish you all the best."+ },+ "createdAt": "2026-08-01T14:09:03.367Z",+ "modifiedAt": "2026-11-19T17:19:28.167Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=fUEwXMnTKo",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/gi0b5ds7f9.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/gi0b5ds7f9.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Gi0B5DS7F9",+ "replyTo": "beZIC48XdV",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer pZ5y",+ "content": {+ "comment": "Thank you for your detailed response. My primary concern is the reproducibility of the model, considering its complex architecture and the fact that the source code for the project has not been released."+ },+ "createdAt": "2026-08-02T23:36:48.814Z",+ "modifiedAt": "2026-11-19T17:19:28.011Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=Gi0B5DS7F9",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/p3f50pgjwu.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/p3f50pgjwu.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "p3f50pgjwU",+ "replyTo": "Rt1sFGfDG8",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Experimental design for human expert evaluation",+ "comment": "The experimental setup is summarized in the table below. All participating experts had relevant professional experience or held a doctoral degree in a related field. None were authors of this paper, and they had no prior knowledge of the methods evaluated in this study. \n\n**Turing Test**: Experts were asked to determine whether each image was AI-generated.\n\n**Scoring evaluation**: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.\n\n(1) Quality (Image Quality)\n\nEvaluate only the visual quality of the image, without considering whether the biological content depicted is accurate or realistic. The assessment should mainly consider noise, blur caused by camera defocus or motion, insufficient illumination, inadequate contrast, and low resolution.\n- **Score 1 — Poor:** The image contains severe noise, blur, insufficient illumination, or inadequate resolution. Key structures are difficult to identify, substantially hindering observation and evaluation.\n- **Score 2 — Fair:** The image has noticeable quality problems. Some structures remain identifiable, but noise, blur, illumination, or resolution issues still significantly affect observation.\n- **Score 3 — Moderate:** The image is generally interpretable, and the main structures are reasonably clear. However, some noise, blur, uneven illumination, or loss of detail remains.\n- **Score 4 — Good:** The image has good clarity and contrast. Only minor noise, blur, or resolution limitations are present, without affecting the observation of major structures and details.\n- **Score 5 — Excellent:** The image is clear and rich in detail, with appropriate illumination and contrast. There is almost no perceptible noise, blur, or resolution-related degradation.\n\n(2) Artifact\nEvaluate whether the image contains artifacts, unexpected textures, excessive enhancement, or excessive denoising that may interfere with observation and assessment.\n- **Score 1 — Severe:** The image contains numerous artifacts or abnormal textures that interfere with evaluation, or shows severe over-enhancement or over-denoising, resulting in obvious structural distortion.\n- **Score 2 — Noticeable:** The image contains multiple artifacts or abnormal textures that interfere with evaluation. Enhancement or denoising has affected the reliability of some structures.\n- **Score 3 — Moderate:** The image contains some artifacts, abnormal textures, enhancement, or denoising that may affect evaluation. However, some of these issues are also difficult to distinguish in the original image based on the evaluator’s knowledge and experience.\n- **Score 4 — Minor:** The image contains essentially no obvious artifacts or abnormal textures that affect evaluation. Any enhancement or denoising is difficult to detect, and the results are generally consistent with the evaluator’s knowledge, experience, and personal assessment.\n- **Score 5 — No noticeable issues:** The image contains no identifiable artifacts, abnormal textures, or inappropriate processing. The enhancement and denoising results are highly consistent with the evaluator’s relevant knowledge and experience.\n\n(3) Constructiveness (Usefulness for Biological Assessment)\nEvaluate whether the image facilitates biological assessment or further research, including but not limited to cell counting, cell segmentation, morphological observation, and quantitative analysis.\n- **Score 1 — Not useful at all:** The image does not support biological assessment and may even be misleading or make interpretation more difficult.\n- **Score 2 — Mostly not useful:** The image provides no noticeable improvement compared with direct observation of the original image.\n- **Score 3 — Somewhat useful:** The image improves the visibility of some structures or details and provides limited assistance for biological observation or analysis.\n- **Score 4 — Highly useful:** The image clearly presents most structures and details relevant to the assessment and facilitates cell counting, segmentation, morphological observation, or other biological analyses.\n- **Score 5 — Extremely useful:** The image substantially improves the visibility and interpretability of relevant structures and details, reliably supporting cell counting, segmentation, quantitative analysis, or other further analyses.\n\n**Swap experiment**: Experts performed cell-counting tasks on different slides, and their counts were compared with the ground-truth values. To prevent prior exposure to the original slides from influencing the evaluation of the AI-processed slides, the experts were divided into two groups: Group A counted cells in the original images, while Group B counted cells in the AI-processed images. The two groups then switched tasks and performed cell counting on another set of previously unseen slides."+ },+ "createdAt": "2026-07-28T15:15:30.060Z",+ "modifiedAt": "2026-11-19T17:19:28.659Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=p3f50pgjwU",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/qccndf8mls.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/qccndf8mls.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "QcCNDf8MlS",+ "replyTo": "Rt1sFGfDG8",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "As the discussion period between authors and reviewers is coming to an end, we would like to follow up and ask whether our responses have adequately addressed your concerns. Please let us know if any further clarification is needed. Thank you."+ },+ "createdAt": "2026-08-04T07:05:16.414Z",+ "modifiedAt": "2026-11-19T17:19:27.961Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=QcCNDf8MlS",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/s8ajzkfdvp.json modified
+++ b/reviews/openreview/2ibxepvy2x/notes/s8ajzkfdvp.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair 7qtq","content": {- "metareview": "The paper proposes BioMicroAgents, which reframes microscopy image processing from a one-shot mapping problem as a closed-loop workflow and introduces three biological-fidelity metrics. It reports strong results across super-resolution, virtual staining, low-light enhancement, denoising, and deblurring, and claims improvements in both perceptual quality and downstream tasks such as segmentation and cell counting. Microscopy image processing should preserve biological fidelity rather than optimize perceptual quality alone. Modeling the process as a closed loop of planning, execution, verification, and rollback is therefore well motivated. The experimental scope is broad, covering super-resolution, virtual staining, denoising, deblurring, and low-light enhancement. \n\nThe system is highly complex, but the necessity of this complexity is not sufficiently established. Because many mechanisms are introduced simultaneously, it remains unclear which component addresses which failure mode and how the system fails when that component is removed. Despite its substantial engineering effort, the paper provides few clear empirical takeaways. Computational cost is not adequately reported. Given the complexity of the framework, its inference overhead is likely substantial, and the paper should clarify whether the performance gains justify the additional cost and deployment complexity. Morphology overlap, color consistency, and texture similarity capture only partial proxy attributes and do not necessarily establish biological correctness."+ "metareview": "The paper proposes BioMicroAgents, which reframes microscopy image processing from a one-shot mapping problem as a closed-loop workflow and introduces three biological-fidelity metrics. It reports strong results across super-resolution, virtual staining, low-light enhancement, denoising, and deblurring, and claims improvements in both perceptual quality and downstream tasks such as segmentation and cell counting. Microscopy image processing should preserve biological fidelity rather than optimize perceptual quality alone. Modeling the process as a closed loop of planning, execution, verification, and rollback is therefore well motivated. The experimental scope is broad, covering super-resolution, virtual staining, denoising, deblurring, and low-light enhancement. \n\nThe system is highly complex, but the necessity of this complexity is not sufficiently established. Because many mechanisms are introduced simultaneously, it remains unclear which component addresses which failure mode and how the system fails when that component is removed. Despite its substantial engineering effort, the paper provides few clear empirical takeaways. Computational cost is not adequately reported. Given the complexity of the framework, its inference overhead is likely substantial, and the paper should clarify whether the performance gains justify the additional cost and deployment complexity. Morphology overlap, color consistency, and texture similarity capture only partial proxy attributes and do not necessarily establish biological correctness.",+ "final_justification": "The authors have addressed the reviewers’ concerns through additional experiments, clearer explanations of the proposed framework, and improved discussions of the method’s limitations. In particular, the authors supplemented the evaluation with additional ablation studies, robustness analysis, and human evaluation to further validate the effectiveness of the proposed multi-agent framework and clarify the necessity of the planning–execution–verification design. \n\nAlthough the framework still has some limitations, such as system complexity and the need for stronger validation of biological fidelity, I believe this work makes a valuable contribution by demonstrating the potential of agent-based workflows for automating complex microscopy image processing tasks."},"createdAt": "2026-07-26T05:24:34.759Z",- "modifiedAt": "2026-11-18T15:23:36.995Z",+ "modifiedAt": "2026-11-19T05:02:16.474Z","url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=s8aJzKfDVp","license": "CC-BY-4.0"}
reviews/openreview/2ibxepvy2x/notes/vmzbk6rv5f.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/vmzbk6rv5f.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "VMZbk6rV5f",+ "replyTo": "Yw7ipy06YI",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Experimental design for human expert evaluation",+ "comment": "The experimental setup is summarized in the table below. All participating experts had relevant professional experience or held a doctoral degree in a related field. None were authors of this paper, and they had no prior knowledge of the methods evaluated in this study. \n\n**Turing Test**: Experts were asked to determine whether each image was AI-generated.\n\n**Scoring evaluation**: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.\n\n(1) Quality (Image Quality)\n\nEvaluate only the visual quality of the image, without considering whether the biological content depicted is accurate or realistic. The assessment should mainly consider noise, blur caused by camera defocus or motion, insufficient illumination, inadequate contrast, and low resolution.\n- **Score 1 — Poor:** The image contains severe noise, blur, insufficient illumination, or inadequate resolution. Key structures are difficult to identify, substantially hindering observation and evaluation.\n- **Score 2 — Fair:** The image has noticeable quality problems. Some structures remain identifiable, but noise, blur, illumination, or resolution issues still significantly affect observation.\n- **Score 3 — Moderate:** The image is generally interpretable, and the main structures are reasonably clear. However, some noise, blur, uneven illumination, or loss of detail remains.\n- **Score 4 — Good:** The image has good clarity and contrast. Only minor noise, blur, or resolution limitations are present, without affecting the observation of major structures and details.\n- **Score 5 — Excellent:** The image is clear and rich in detail, with appropriate illumination and contrast. There is almost no perceptible noise, blur, or resolution-related degradation.\n\n(2) Artifact\n\nEvaluate whether the image contains artifacts, unexpected textures, excessive enhancement, or excessive denoising that may interfere with observation and assessment.\n- **Score 1 — Severe:** The image contains numerous artifacts or abnormal textures that interfere with evaluation, or shows severe over-enhancement or over-denoising, resulting in obvious structural distortion.\n- **Score 2 — Noticeable:** The image contains multiple artifacts or abnormal textures that interfere with evaluation. Enhancement or denoising has affected the reliability of some structures.\n- **Score 3 — Moderate:** The image contains some artifacts, abnormal textures, enhancement, or denoising that may affect evaluation. However, some of these issues are also difficult to distinguish in the original image based on the evaluator’s knowledge and experience.\n- **Score 4 — Minor:** The image contains essentially no obvious artifacts or abnormal textures that affect evaluation. Any enhancement or denoising is difficult to detect, and the results are generally consistent with the evaluator’s knowledge, experience, and personal assessment.\n- **Score 5 — No noticeable issues:** The image contains no identifiable artifacts, abnormal textures, or inappropriate processing. The enhancement and denoising results are highly consistent with the evaluator’s relevant knowledge and experience.\n\n(3) Constructiveness (Usefulness for Biological Assessment)\n\nEvaluate whether the image facilitates biological assessment or further research, including but not limited to cell counting, cell segmentation, morphological observation, and quantitative analysis.\n- **Score 1 — Not useful at all:** The image does not support biological assessment and may even be misleading or make interpretation more difficult.\n- **Score 2 — Mostly not useful:** The image provides no noticeable improvement compared with direct observation of the original image.\n- **Score 3 — Somewhat useful:** The image improves the visibility of some structures or details and provides limited assistance for biological observation or analysis.\n- **Score 4 — Highly useful:** The image clearly presents most structures and details relevant to the assessment and facilitates cell counting, segmentation, morphological observation, or other biological analyses.\n- **Score 5 — Extremely useful:** The image substantially improves the visibility and interpretability of relevant structures and details, reliably supporting cell counting, segmentation, quantitative analysis, or other further analyses.\n\n**Swap experiment**: Experts performed cell-counting tasks on different slides, and their counts were compared with the ground-truth values. To prevent prior exposure to the original slides from influencing the evaluation of the AI-processed slides, the experts were divided into two groups: Group A counted cells in the original images, while Group B counted cells in the AI-processed images. The two groups then switched tasks and performed cell counting on another set of previously unseen slides."+ },+ "createdAt": "2026-07-28T15:18:41.832Z",+ "modifiedAt": "2026-11-19T17:19:28.779Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=VMZbk6rV5f",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/waorsnrqge.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/waorsnrqge.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "WaOrsnRQGE",+ "replyTo": "e3t2j10eT1",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Further Questions (Part 2)",+ "comment": "We adopted a standardized, blinded, and randomized experimental protocol in which three domain experts completed three complementary evaluation tasks. First, in a Turing-test-like authenticity discrimination task, each expert was asked to distinguish real images from images generated by each comparison method. Second, in the subjective rating task, the experts independently evaluated randomly sampled images from each method using a five-point scale across three dimensions: overall image quality, artifact suppression, and biological utility. Finally, we designed a crossover cell-counting experiment in which the experts were assigned to either an A–B or B–A evaluation sequence. Each expert first performed cell counting on either the original images or the AI-processed images, then switched to the alternative condition and continued the evaluation using previously unseen tissue sections. This design was intended to reduce potential memory, learning, and order effects. Before the formal evaluation, all experts received the same written task instructions, which explicitly defined each evaluation dimension, the corresponding scoring criteria, and the cell-counting procedure. Images were randomly sampled to prevent overrepresentation of any particular scenario. All images were anonymized by removing method names and associated metadata and were presented to each expert in an independently randomized order. The experts were unaware of the methods corresponding to the images and of the study hypotheses, and they completed all evaluations independently without discussion.\n\nFor each dimension, inter-rater agreement was assessed using Kendall’s coefficient of concordance W, with correction for tied ranks. Statistical significance was evaluated using the corresponding chi-square test. We additionally calculated two-way random-effects, absolute-agreement intraclass correlation coefficients. ICC(A,1) measures the reliability of the rating from a single randomly selected expert, whereas ICC(A,3) measures the reliability of the mean rating aggregated across the three experts. The 95% confidence intervals were also reported.\n\n| Dimension | Kendall’s \\(W\\) | \\(p\\) | ICC(A,1) | 95% CI | ICC(A,3) | 95% CI |\n| --------------------- | --------------: | -----: | -------: | -----------: | -------: | -----------: |\n| Quality | 0.64 | <0.001 | 0.74 | [0.68, 0.79] | 0.90 | [0.86, 0.92] |\n| Artifact | 0.61 | <0.001 | 0.70 | [0.63, 0.76] | 0.88 | [0.84, 0.91] |\n| Biological usefulness | 0.58 | <0.001 | 0.67 | [0.59, 0.73] | 0.86 | [0.81, 0.89] |\n\nThe expert evaluations showed statistically significant inter-rater agreement across all three dimensions (p<0.001). Kendall’s W was 0.64 for image quality, 0.61 for artifact assessment, and 0.58 for biological usefulness, indicating moderate-to-strong concordance among the experts. The single-rater absolute-agreement reliability was also satisfactory, with ICC(A,1) values ranging from 0.67 to 0.74. After averaging the ratings of the three experts, ICC(A,3) increased to 0.86–0.90, demonstrating good-to-excellent reliability of the expert scores. \n\nWe look forward to receiving your feedback and would be happy to discuss any remaining questions that may require further clarification. Thank you again for your patience and thorough review."+ },+ "createdAt": "2026-08-02T10:03:25.719Z",+ "modifiedAt": "2026-11-19T17:19:28.060Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=WaOrsnRQGE",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/wb4i2enpo4.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/wb4i2enpo4.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Wb4I2Enpo4",+ "replyTo": "Gi0B5DS7F9",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you again for your recognition and valuable comments. We also attach great importance to reproducibility and practical applicability. We have reported the parameters and system prompts for most components in Appendices B, C, and D, and have submitted part of our currently private data in the supplementary materials. We commit to publicly releasing all private data used in this work, together with the model weights and source code, upon acceptance. Regardless of the final decision, we sincerely hope that you will continue to follow our work."+ },+ "createdAt": "2026-08-03T03:12:24.625Z",+ "modifiedAt": "2026-11-19T17:19:28.192Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=Wb4I2Enpo4",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/xx9cryv7gh.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/xx9cryv7gh.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Xx9CRyv7GH",+ "replyTo": "s8aJzKfDVp",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to Meta Review",+ "comment": "We sincerely thank all reviewers for their valuable comments and constructive suggestions. During the rebuttal stage, we further clarified the implementation details and methodology and provided supplementary experiments. Reviewer 8Et7 expressed recognition of our work and increased the overall score from 4 to 5, while Reviewer PZ5y maintained a score of 5. We again thank the AC and all reviewers. We commit to releasing all project code, experimental configurations, and evaluation scripts upon acceptance of the paper.\n\nResponses to the AC’s Concerns\n\n1. Necessity of the System Complexity and Contributions of Individual Components: Reviewers PZ5y and 8Et7 both acknowledged our component ablation experiments. In addition, the comparative and supplementary experiments(Rebuttal to PZ5y, Tables 1 and 2) further demonstrate that the benefits of the individual components do not originate from the expert models. Removing co-evolution, RAG, successful memory, or failure memory consistently degrades both biological-fidelity metrics and downstream performance. The performance improvements primarily arise from the closed-loop workflow formed by dynamic planning, rigorous verification, and the two co-evolution strategies.\n2. Computational Overhead and Deployment Complexity: We acknowledge that BioMicroAgents incurs additional computational costs and therefore report the inference time of the RAG, memory, planning, processing, and verification stages separately (Rebuttal to 8Et7, Table 8). Our central argument is that biological microscopy image processing prioritizes fidelity over speed; therefore, efficiency should not be evaluated independently of biological-fidelity requirements. Nevertheless, the computational complexity of our framework remains acceptable. Supplementary experiments further show that, under the same fidelity-verification criteria, artifacts produced by comparative methods trigger more rollbacks and repeated processing, whereas BioMicroAgents reduces such ineffective cycles through its evolutionary mechanisms (Rebuttal to 8Et7, Table 4).\n3. Biological-Fidelity Metrics Cannot Directly Demonstrate Biological Correctness: Most evaluation and optimization metrics and downstream tasks used in our study are widely recognized and valued in biological research, giving them meaningful biological relevance. These metrics capture complementary failure modes overlooked by conventional perceptual-quality metrics. We further conducted expert evaluations involving authenticity discrimination, five-point scoring, and crossover cell counting (Rebuttal to PZ5y, Tables 3–5). Kendall’s (W) ranged from 0.58 to 0.64, while the ICC of the three experts’ mean ratings ranged from 0.86 to 0.90, indicating good consistency among expert evaluations. \n\nSignificance and Strengths of the Paper\n\n1. This paper proposes a unified closed-loop framework for microscopy image processing, formulating the microscopy workflow as a closed-loop process involving planning, execution, verification, rollback, and evolution. It simulates the observation, verification, and adjustment procedures employed by human experts and is fundamentally different from one-shot image mappings and simple unidirectional verifier–executor structures. This contribution was widely recognized by the reviewers.\n2. This paper addresses an important yet long-underappreciated issue: microscopy image processing must preserve biological fidelity rather than pursue perceptual quality alone, a point consistently recognized by the reviewers. Our framework therefore makes biological fidelity a central objective of planning, processing, and verification, rather than merely a post hoc metric, and uses biologically tailored co-evolution mechanisms to continuously improve subsequent processing strategies.\n3. The proposed framework is applicable to multiple microscopy imaging tasks and can be deployed across different scenarios, while also accommodating compound degradations and multi-step processing requests. Moreover, the framework goes beyond solving a single task. It can iteratively improve both imaging quality and biological fidelity in a manner consistent with biological workflows. \n4. The experimental validation is multi-level and complementary, combining perceptual-quality and biological-fidelity metrics, downstream segmentation and counting tasks, component ablations, and independent expert evaluations. This protocol reduces single-metric bias and better reflects the practical requirements of real-world biological microscopy analysis.\n\nConclusion\n\nWe believe that the primary contribution of BioMicroAgents lies in redefining biological microscopy image processing as a closed-loop process that is constrained by biological fidelity and capable of planning, verification, rollback, and evolution. These contributions establish BioMicroAgents as a reliable framework for microscopy image processing. We again thank all reviewers and AC for their evaluation and feedback."+ },+ "createdAt": "2026-08-04T08:19:45.430Z",+ "modifiedAt": "2026-11-19T17:19:27.954Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=Xx9CRyv7GH",+ "license": "CC-BY-4.0"+}