BioMicroAgents: A Co-evolutionary Multi-Agent Framework for High-Fidelity Biomicroscopy Imaging
Import NeurIPS 2026 submission 2IBxEPvy2X: 8 notes
@openreview[bot] · 2026-11-22 17:53 UTC · 4f744aeac0f8
.gitattributes added
+++ b/.gitattributes@@ -0,0 +1,10 @@+# PDFs and pictures are kept with Git LFS (https://git-lfs.com). With it installed (`git lfs install`),+# a clone has the files, and `git add` of one stores a pointer. This file is the same on every page.+/.potentialpaper/*.pdf filter=lfs diff=lfs merge=lfs -text+/versions/*.pdf filter=lfs diff=lfs merge=lfs -text+/thumbnail.png filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpg filter=lfs diff=lfs merge=lfs -text+/thumbnail.jpeg filter=lfs diff=lfs merge=lfs -text+/thumbnail.gif filter=lfs diff=lfs merge=lfs -text+/thumbnail.webp filter=lfs diff=lfs merge=lfs -text+/thumbnail.avif filter=lfs diff=lfs merge=lfs -text
.potentialpaper/metadata.json added
+++ b/.potentialpaper/metadata.json@@ -0,0 +1,25 @@+{+ "layout": 5,+ "identifiers": [+ {+ "scheme": "openreview",+ "value": "2IBxEPvy2X"+ }+ ],+ "title": "BioMicroAgents: A Co-evolutionary Multi-Agent Framework for High-Fidelity Biomicroscopy Imaging",+ "authors": [+ "Yongwei Jiang",+ "Peilin Li",+ "anfu deng",+ "Jun Yin",+ "XiaoyuChen"+ ],+ "abstract": "Biomicroscopy imaging involves the complex coordination of multiple procedures, such as focusing, illumination, and staining. Traditional unitary methods struggle with dynamical environments, while hybrid models pre-trained on natural images tend to introduce artifacts for higher perceptual metrics. Notably, biological imaging is not a one-off task. It is an iterative process similar to human expert’s observation, verification and adjustment. They can benefit from history, remembering which processing strategies are suitable and can also identify issues such as artifacts and mis-staining from verification.\nTo this end, we propose BioMicroAgents, the first multi-agent framework with co-evolutionary capabilities designed to simulate and optimize whole biomicro imaging process including brightening, denoising, deblur, super-resolution, and virtual staining. Through reinforcement learning, the model can reflect based on historical experience to reduce artifacts and mis-staining, while enhancing edge and structural features to improve the accuracy of downstream tasks.\nSpecifically, BioMicroAgents includes:\n(i) Multi-modal Analytical Agents, which utilize multimodal RAG to provide template images and biomicro knowledge, and employ the memory mechanism to analyze optimal processing paths;\n(ii) We propose three biomicro fidelity metrics and utilize three agent groups (MicroNavigator, MicroProcessor, and MicroAuthenticator) to perform rigorous analysis, processing, and verification.\n(iii) Co-evolutionary ability, which achieves dynamic policy and self-correction through interactive feedback strategies and memory mechanisms, allowing the agent to evolve from history and other agents.\nWe test model across 12 biomicro tasks, BioMicroAgents achieved improvements in perceptual quality while adhering to strict fidelity in sub-cellular features. It also enhances the accuracy of downstream tasks such as segmentation and cell counting, showcasing the potential of general-purpose visual agents in bioscience.",+ "year": 2026,+ "venue": "NeurIPS 2026",+ "source": "openreview",+ "license": {+ "metadata": "CC0-1.0",+ "abstract": "CC0-1.0"+ }+}
community/10-tl-dr.md added
+++ b/community/10-tl-dr.md
community/20-summary.md added
+++ b/community/20-summary.md
community/30-why-it-matters.md added
+++ b/community/30-why-it-matters.md
community/40-critique.md added
+++ b/community/40-critique.md
community/50-errata.md added
+++ b/community/50-errata.md
community/60-reproductions.md added
+++ b/community/60-reproductions.md
community/70-follow-ups.md added
+++ b/community/70-follow-ups.md
owners/10-tl-dr.md added
+++ b/owners/10-tl-dr.md
owners/20-overview.md added
+++ b/owners/20-overview.md
owners/30-results.md added
+++ b/owners/30-results.md
owners/40-demos.md added
+++ b/owners/40-demos.md
owners/50-code-and-data.md added
+++ b/owners/50-code-and-data.md
owners/60-talks.md added
+++ b/owners/60-talks.md
prek.toml added
+++ b/prek.toml@@ -0,0 +1,36 @@+# Checks run before each commit, with prek (https://prek.j178.dev): `prek install` once in this clone.+# The site checks every push again; these catch mistakes before you commit. The same on every page.++[[repos]]+repo = "builtin"+hooks = [+ { id = "check-json" },+ { id = "pretty-format-json", args = ["--autofix", "--no-sort-keys", "--no-ensure-ascii"], exclude = '^demos/' },+ { id = "end-of-file-fixer", exclude = '^demos/' },+ { id = "trailing-whitespace", args = ["--markdown-linebreak-ext=md"], exclude = '^demos/' },+ { id = "check-case-conflict" },+ { id = "check-illegal-windows-names" },+ { id = "check-added-large-files", args = ["--maxkb=256"], exclude = '^demos/' },+]++# Each JSON file against its schema (https://papers.potentialhedge.com/schemas/).+[[repos]]+repo = "https://github.com/python-jsonschema/check-jsonschema"+rev = "0.39.0"+hooks = [+ { id = "check-jsonschema", name = "author section plugins files", files = '^owners/plugins\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/authorPlugins.json"] },+ { id = "check-jsonschema", name = "venue files", files = '^venue\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/venue.json"] },+ { id = "check-jsonschema", name = "topic files", files = '^topic\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/topic.json"] },+ { id = "check-jsonschema", name = "organisation files", files = '^org\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/org.json"] },+ { id = "check-jsonschema", name = "link files", files = '^links/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/link.json"] },+ { id = "check-jsonschema", name = "version files", files = '^versions/[^/]+\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/version.json"] },+ { id = "check-jsonschema", name = "picture files", files = '^thumbnail\.json$', args = ["--schemafile", "https://papers.potentialhedge.com/schemas/thumbnail.json"] },+]++# Sections formatted the way the web editor formats them.+[[repos]]+repo = "https://github.com/rbubley/mirrors-prettier"+rev = "v3.9.9"+hooks = [+ { id = "prettier", files = '^(owners|community)/.*\.md$' },+]
reviews/openreview/2ibxepvy2x/forms.json added
+++ b/reviews/openreview/2ibxepvy2x/forms.json@@ -0,0 +1,227 @@+{+ "schema": "forms/1",+ "forms": {+ "Meta_Review": {+ "label": "Meta-review",+ "fields": [+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ }+ ]+ },+ "Decision": {+ "label": "Decision",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "hidden": true+ },+ {+ "key": "decision",+ "label": "Decision",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ },+ {+ "key": "metareview",+ "label": "Meta-review",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ }+ ]+ },+ "Official_Comment": {+ "label": "Comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Public_Comment": {+ "label": "Public comment",+ "fields": [+ {+ "key": "title",+ "label": "Title",+ "type": "choice"+ },+ {+ "key": "comment",+ "label": "Comment",+ "type": "text"+ }+ ]+ },+ "Withdrawal": {+ "label": "Withdrawal",+ "fields": [+ {+ "key": "withdrawal_confirmation",+ "label": "Confirmation",+ "hidden": true+ }+ ]+ },+ "Desk_Rejection": {+ "label": "Desk rejection",+ "fields": [+ {+ "key": "desk_reject_comments",+ "label": "Reason",+ "type": "text"+ }+ ]+ },+ "Official_Review": {+ "label": "Official review",+ "summary": [+ "rating",+ "confidence",+ "quality",+ "clarity",+ "significance",+ "originality"+ ],+ "fields": [+ {+ "key": "rating",+ "label": "Rating",+ "type": "score",+ "min": 1,+ "max": 6+ },+ {+ "key": "confidence",+ "label": "Confidence",+ "type": "score",+ "min": 1,+ "max": 5+ },+ {+ "key": "quality",+ "label": "Quality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "clarity",+ "label": "Clarity",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "significance",+ "label": "Significance",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "originality",+ "label": "Originality",+ "type": "score",+ "min": 1,+ "max": 4+ },+ {+ "key": "contribution_type",+ "label": "Contribution type",+ "type": "choice"+ },+ {+ "key": "summary",+ "label": "Summary",+ "type": "text"+ },+ {+ "key": "strengths_and_weaknesses",+ "label": "Strengths and weaknesses",+ "type": "text"+ },+ {+ "key": "questions",+ "label": "Questions",+ "type": "text"+ },+ {+ "key": "limitations",+ "label": "Limitations",+ "type": "text"+ },+ {+ "key": "final_justification",+ "label": "Final justification",+ "type": "text"+ },+ {+ "key": "paper_formatting_concerns",+ "label": "Formatting concerns",+ "type": "text"+ },+ {+ "key": "ethical_concerns",+ "label": "Ethical concerns",+ "type": "choice"+ },+ {+ "key": "code_of_conduct_acknowledgement",+ "label": "Code of conduct",+ "hidden": true+ },+ {+ "key": "responsible_reviewing_acknowledgement",+ "label": "Responsible reviewing",+ "hidden": true+ }+ ]+ },+ "Rebuttal": {+ "label": "Rebuttal",+ "fields": [+ {+ "key": "rebuttal",+ "label": "Rebuttal",+ "type": "text"+ }+ ]+ },+ "Ethics_Review": {+ "label": "Ethics review",+ "fields": [+ {+ "key": "scope_of_ethics_concerns",+ "label": "Scope",+ "type": "choice"+ },+ {+ "key": "ethics_review",+ "label": "Ethics review",+ "type": "text"+ }+ ]+ }+ },+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/bezic48xdv.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/bezic48xdv.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "beZIC48XdV",+ "replyTo": "N6zXWVRpuW",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for your positive assessment of our work and for raising these constructive questions. We address your questions one by one.\n\n1. **Could the authors further discuss the roles of Navigator, Processor, and Authenticator, and whether certain agents contribute more significantly to performance gains than others?**\n\n\tThe three agent groups perform **complementary** rather than **interchangeable** functions. **MicroNavigator** integrates user requirements, microscopy-domain knowledge, staining templates, and memories of both successful and failed cases to determine which operations should be performed and in what order. **MicroProcessor** dynamically schedules task-relevant expert models to determine how the selected operations should be executed. **MicroAuthenticator** evaluates cellular morphology, staining consistency, and histological texture to determine whether the output of each step satisfies the biological requirements, triggering rollback or providing rewards for policy updates when necessary. Therefore, MicroAuthenticator not only directly affects the processor policy $\\pi_p$, but also influences the subsequent navigator policy $\\pi_n$ through memory-based feedback.\n\n\tMicroNavigator is particularly important for compound degradations and complex processing requests; MicroAuthenticator plays a more prominent role in tasks sensitive to biological fidelity, such as virtual staining and high-magnification super-resolution; and MicroProcessor provides the underlying image-processing capabilities. Table 7 shows that the results of removing reinforcement-learning-based co-evolution, RAG, successful-case memory, or failure-case memory. For example, on the Lap dataset, removing Coev.-RL, RAG, successful-case memory ($E^+$), and failure-case memory ($E^-$) changed NIQE from 2.81 to 3.23, 2.74, 3.05, and 3.18, respectively; decreased CLIPIQA from 0.394 to 0.341, 0.403, 0.352, and 0.331; decreased ACC from 0.892 to 0.879, 0.871, 0.882, and 0.878; and decreased Dice from 0.781 to 0.772, 0.738, 0.772, and 0.768.\n\t\n\tTo address your question more directly, we further conducted two additional ablation experiments:(i) We removed MicroNavigator and applied a fixed processing pipeline to all images (FIX).(ii) We replaced MicroNavigator with Qwen3-VL, which directly generated biological microscopy priors and planned the processing workflow (VLP). The results are presented in the table below.\n\n| Task (IHC2Lap) | NIQE ↓ | CLIPIQA ↑ | ACC ↑ | DICE ↑ |\n| -------------- | ------ | --------- | ----- | ------ |\n| FIX | 3.56 | 0.321 | 0.783 | 0.694 |\n| VLP | 3.29 | 0.351 | 0.850 | 0.738 |\n| BioMicroAgents | 2.81 | 0.394 | 0.892 | 0.781 |\n\nIn the comparative experiments, comparisons with individual strong expert models already demonstrate the contributions of our agentic framework and co-evolution mechanism (Tables 1–3). We further conducted an additional ablation study by removing several strong expert models from the expert pool and evaluating the resulting framework performance.\n\n| Task (IHC2Lap) | NIQE ↓ | CLIPIQA ↑ | SSIM ↑ | PSNR ↑ | Dice ↑ | ACC ↑ |\n| -------------- | ------ | --------- | ------ | ------ | ------ | ----- |\n| -MicroEdit-VS | 2.85 | 0.391 | 0.910 | 35.05 | 0.779 | 0.892 |\n| -MicroEdit-SR | 2.87 | 0.388 | 0.906 | 34.94 | 0.778 | 0.887 |\n| BioMicroAgents | 2.81 | 0.394 | 0.912 | 35.12 | 0.781 | 0.892 |\n\n2. **Are there specific task types or imaging scenarios where BioMicroAgents is less effective, and what are the primary failure modes observed in practice?**\n\n\tBioMicroAgents does not achieve improvements of the same magnitude across all datasets and evaluation metrics. For example, on the IHC dataset, BioMicroAgents improves PSNR by only 0.5 dB compared with 4KAgent. The improvements in perceptual metrics are also relatively modest, with NIQE decreasing by 0.15 and CLIPIQA increasing by 0.007. However, this reflects the multi-objective nature of our method: rather than optimizing a single similarity metric, we balance perceptual quality, structural preservation, staining consistency, and downstream analysis performance.\n\t\n\tThe main challenging scenarios observed thus far include:\n\t\n\t1. **Extremely severe image degradation.** When biological structures have already been irreversibly lost from the original data, they cannot be reliably recovered. Such cases are relatively rare and occur mainly under artificially introduced severe degradations, such as the extreme 8× downsampling results reported in Table XX.\n\t \n\t2. **Insufficient information for cross-stain translation.** This is a well-recognized limitation in virtual staining: one staining modality may not contain the information required to infer another staining modality. In such cases, MicroNavigator identifies the request as infeasible and refuses to include it as an executable task in the processing plan.\n3. **Could the authors provide additional discussion of how these metrics correlate with expert biological assessment, or whether they generalize across imaging modalities?**\n\n\tWe fully agree that this is an important question. We therefore conducted additional evaluations involving independent human experts and report the corresponding rating-scale statistics to further validate our experimental findings. The experimental setup is summarized in the table below. All participating experts had relevant professional experience or held a doctoral degree in a related field. None were authors of this paper, and they had no prior knowledge of the methods evaluated in this study. Due to space limitations, please allow us to provide the experimental details in a subsequent comment.\n\nTuring Test: Experts were asked to determine whether each image was AI-generated.\n\n| Expert | Real (90) | SwinIR (30) | 4KAgent (30) | BioMicroAgents (30) | Sensitivity | Overall Accuracy |\n| ------------------ | --------- | ----------- | ------------ | ------------------- | ----------- | ---------------- |\n| 1 | 27/90 | 21/30 | 29/30 | 16/30 | 0.733 | 0.717 |\n| 2 | 6/90 | 12/30 | 28/30 | 7/30 | 0.522 | 0.728 |\n| 3 | 42/90 | 17/30 | 30/30 | 9/30 | 0.622 | 0.578 |\n| AI Pass Rate | – | 0.444 | 0.033 | 0.644 | – | – |\n| Standard Deviation | – | 0.150 | 0.033 | 0.158 | – | – |\n\nScoring evaluation: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.\n\n| Expert | Scoring Rubric | DiffBIR + ImageEdit (50) | 4KAgent + ImageEdit (50) | BioMicroAgents (50) |\n| ------ | ---------------- | -----------------------: | -----------------------: | ------------------: |\n| 1 | Quality | 3.68/0.59 | 3.92/0.28 | 4.24/0.23 |\n| | Artifact | 2.86/0.33 | 3.10/0.30 | 4.08/0.32 |\n| | Constructiveness | 2.94/0.63 | 3.52/0.54 | 4.10/0.30 |\n| 2 | Quality | 3.86/0.34 | 3.74/0.69 | 4.36/0.24 |\n| | Artifact | 3.08/0.32 | 2.94/0.34 | 4.20/0.26 |\n| | Constructiveness | 3.28/0.74 | 3.16/0.63 | 4.34/0.23 |\n| 3 | Quality | 3.58/0.78 | 4.02/0.26 | 4.18/0.35 |\n| | Artifact | 2.64/1.09 | 3.26/0.48 | 3.98/0.43 |\n| | Constructiveness | 2.82/0.76 | 3.70/0.62 | 4.06/0.38 |\n\nSwap experiment: Experts were divided into AB groups to count cells in either original or AI images, and accuracy was calculated. The groups then switched conditions and evaluated unseen slides to avoid bias from prior exposure.\n\n| Expert | Origin | 4KAgent | ImageEdit | DiffBIR + ImageEdit | 4KAgent + ImageEdit | BioMicroAgents |\n| ------ | ------ | ------- | --------- | ------------------- | ------------------- | -------------- |\n| A-B | 0.787 | 0.715 | 0.812 | 0.627 | 0.684 | 0.823 |\n| B-A | 0.776 | 0.683 | 0.793 | 0.632 | 0.688 | 0.830 |\n\n4. **Could the authors provide additional qualitative examples illustrating how agent behavior evolves and how historical memory influences decision-making?**\n\n\tFigure 5 quantitatively illustrates how the reward and memory change throughout the co-evolution process. As co-evolution progresses, non-biological artifacts are gradually reduced and structural information is enhanced (Fig. 5a). The memory-evolution experiment with frozen model parameters disentangles the benefits of retrieving historical experience from those arising from model parameter updates (Fig. 5b). In addition, Appendix C demonstrates how successful and failed memories influence agent behavior: the model can retrieve similar cases, adopt corresponding successful strategies, and avoid repeating previously failed approaches.\n\n\tWe agree that explicitly presenting the decision trajectories would make this mechanism more intuitive. Therefore, we have added visualizations of the evolutionary process to the revised manuscript."+ },+ "createdAt": "2026-07-28T11:17:57.016Z",+ "modifiedAt": "2026-11-18T17:19:08.587Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=beZIC48XdV",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/d83bwfisyh.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/d83bwfisyh.json@@ -0,0 +1,19 @@+{+ "schema": "review/1",+ "id": "d83BWFISyh",+ "replyTo": null,+ "kind": "decision",+ "invitation": "Decision",+ "signature": "Program Chairs",+ "content": {+ "title": "Paper Decision",+ "decision": "Accept (poster)",+ "comment": "",+ "metareview": "The paper proposes BioMicroAgents, which reframes microscopy image processing from a one-shot mapping problem as a closed-loop workflow and introduces three biological-fidelity metrics. It reports strong results across super-resolution, virtual staining, low-light enhancement, denoising, and deblurring, and claims improvements in both perceptual quality and downstream tasks such as segmentation and cell counting. Microscopy image processing should preserve biological fidelity rather than optimize perceptual quality alone. Modeling the process as a closed loop of planning, execution, verification, and rollback is therefore well motivated. The experimental scope is broad, covering super-resolution, virtual staining, denoising, deblurring, and low-light enhancement. \n\nThe system is highly complex, but the necessity of this complexity is not sufficiently established. Because many mechanisms are introduced simultaneously, it remains unclear which component addresses which failure mode and how the system fails when that component is removed. Despite its substantial engineering effort, the paper provides few clear empirical takeaways. Computational cost is not adequately reported. Given the complexity of the framework, its inference overhead is likely substantial, and the paper should clarify whether the performance gains justify the additional cost and deployment complexity. Morphology overlap, color consistency, and texture similarity capture only partial proxy attributes and do not necessarily establish biological correctness.",+ "final_justification": "The authors have addressed the reviewers’ concerns through additional experiments, clearer explanations of the proposed framework, and improved discussions of the method’s limitations. In particular, the authors supplemented the evaluation with additional ablation studies, robustness analysis, and human evaluation to further validate the effectiveness of the proposed multi-agent framework and clarify the necessity of the planning–execution–verification design. \n\nAlthough the framework still has some limitations, such as system complexity and the need for stronger validation of biological fidelity, I believe this work makes a valuable contribution by demonstrating the potential of agent-based workflows for automating complex microscopy image processing tasks."+ },+ "createdAt": "2026-09-24T11:24:24.696Z",+ "modifiedAt": "2026-11-18T14:57:26.848Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=d83BWFISyh",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/lv27amyas1.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/lv27amyas1.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "Lv27AmyaS1",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer moa1",+ "content": {+ "summary": "The paper proposes BioMicroAgents, a multi-agent microscopy image-processing framework with planning, RAG, memory, expert model routing, verification, rollback, and RL-style co-evolution. It targets many tasks.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "Strength:\n1. Microscopy image processing does need biological fidelity, not just perceptual quality.\n2. The closed-loop framing of planning → processing → verification → rollback is reasonable.\n\n\nWeakness:\n1. The paper is organized and written badly: \n- The method is a large system assembled from many existing models, agents, RAG, memory, segmentation, reward models, diffusion/RL, and expert modules. It is very hard to tell what is actually new and what is simply orchestration.\n- The method part is hard to read with too many unnecessary symbols\n- The introduction has **0** references\n- Many grammatical issues, unclear equations, inconsistent notation, and broad claims like “self-evolving” without enough support.\n2. The metrics in MicroAuthenticator heavily depend on the accuracy of the segmentation model; what if OOD data for the segmentation model comes in? The Co-evolution will be guided by wrong rewards. The author also doesn't mention the details of the segmentation model in this part\n3. What is the exact prompt/RAG/memory content used for each task?\n4. I believe the whole system will be extremely hard to reproduce since we need to build all the RAG, memory, template, and co-evolution before getting the result. \n5. The author built a large, complicated system with minimal improvement on some datasets that are not worth such a complicated system. \n\nOverall, the author wants to build all, but I don't think microscopy image enhancement tasks need such a large and complicated system... Maybe planning + a list of + metrics models is enough. In microscopy, without enough data support, a complicated system may lead to overfitting.",+ "quality": 2,+ "clarity": 1,+ "significance": 2,+ "originality": 2,+ "questions": "See above",+ "limitations": "See above",+ "rating": 2,+ "confidence": 5,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "My final score is still 2 since I'm still worry about applying such a complicated system to the microscopy image enhancement task with minimal performance improvement (maybe it can be achieved with a much clean and smaller agent system). The author do not provide evidence on how each proposed element helps the task, such as a template, co-evolution. \n\nThe author addresses my minimal concerns but leaves the major concern unsolved. So I would like to keep my score."+ },+ "createdAt": "2026-06-24T13:50:14.392Z",+ "modifiedAt": "2026-11-18T13:42:29.544Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=Lv27AmyaS1",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/n6zxwvrpuw.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/n6zxwvrpuw.json@@ -0,0 +1,31 @@+{+ "schema": "review/1",+ "id": "N6zXWVRpuW",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer pZ5y",+ "content": {+ "summary": "This work proposes BioMicroAgents, a multi-agent framework for simulating and optimizing biomicroscopy imaging workflows. Inspired by the iterative observation and verification process of human experts, the framework employs three agent groups—MicroNavigator, MicroProcessor, and MicroAuthenticator—to perform planning, processing, and verification, respectively. Through reinforcement learning, memory mechanisms, and interactive feedback, the agents can adapt processing strategies and reduce artifacts over time. Experimental results across multiple biomicro imaging tasks demonstrate improvements in image quality, biological fidelity, and downstream analysis performance.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "This paper proposes BioMicroAgents, a multi-agent framework for simulating and optimizing biomicroscopy imaging workflows. The framework employs three agent groups—MicroNavigator, MicroProcessor, and MicroAuthenticator—to perform planning, processing, and verification, respectively. Through reinforcement learning, memory mechanisms, and interactive feedback, the agents iteratively improve imaging quality and biological fidelity across a wide range of biomicro imaging tasks. The work addresses an important and practical problem in biological imaging, where traditional single-stage approaches often struggle to adapt to complex and dynamic imaging conditions. A key strength of the work is the formulation of biomicro imaging as a collaborative multi-agent process that mimics the observation, verification, and adjustment workflow used by human experts. The integration of memory, feedback, and co-evolutionary learning mechanisms is well motivated and provides a coherent framework for iterative image enhancement and analysis. The paper is generally clear, and the proposed architecture is intuitive despite its complexity. These results from 12 datasets suggest that the framework is broadly applicable across diverse imaging scenarios. While additional analysis of component contributions and computational efficiency would further strengthen the work, I find the problem formulation, methodological design, and empirical validation to be compelling. Overall, this paper presents a meaningful and potentially impactful contribution to AI for biological imaging",+ "quality": 4,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "-\tSince the work demonstrates the effectiveness of multimodal RAG, co-evolution, and memory mechanisms through ablation studies. Could the authors further discuss the individual roles of MicroNavigator, MicroProcessor, and MicroAuthenticator, and whether certain agents contribute more significantly to performance gains than others?\n-\tSuch a proposed BioMicroAgents framework is evaluated across 12 biomicro imaging tasks. Are there specific task types or imaging scenarios where BioMicroAgents is less effective, and what are the primary failure modes observed in practice?\n-\tThis work introduces biomicro fidelity metrics to evaluate biological consistency. Could the authors provide additional discussion of how these metrics correlate with expert biological assessment, or whether they generalize across imaging modalities?\n-\tThe co-evolutionary mechanism appears to be a key contribution of the framework. Could the authors provide additional qualitative examples illustrating how agent behavior evolves and how historical memory influences decision-making?",+ "limitations": "Yes",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "No Formatting Concerns",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes"+ },+ "createdAt": "2026-06-22T17:37:25.427Z",+ "modifiedAt": "2026-11-18T13:42:30.775Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=N6zXWVRpuW",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/rt1sfgfdg8.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/rt1sfgfdg8.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Rt1sFGfDG8",+ "replyTo": "Lv27AmyaS1",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for your thoughtful and constructive feedback, we address your comments below.\n\n1. **Contribution goes beyond orchestrating existing components and “self-evolving” without enough support**\n\nOur key innovations are articulated in the main text(Points 1 and 2 of the Conbtribution in Introduction), and Reviewer pZ5y also acknowledged that “The integration of memory, feedback, and co-evolutionary learning mechanisms is well motivated .” Our core insight is to model the professional biological microscopy imaging workflow as a collaborative multi-agent process that emulates how experts iteratively observe, validate, and adjustment. Specifically, the agents are not isolated but co-evolve as they process data. Unlike conventional unidirectional verifier–executor loops that provide only post hoc scores, or isolated reward optimization, BioMicroAgents enables biological-fidelity-driven co-adaptation by jointly optimizing $\\pi_p$ and $\\pi_n$ under rigorous verification. This design mirrors expert workflows and is further tailored to the biological domain (Eq. 6, Fig. 2).\n\t\nWe demonstrate these contributions through comparative and ablation studies. Our comparisons include single-agent frameworks and strong expert models, particularly 4KAgent (NeurIPS 2025), with both methods evaluated on several shared datasets. The ablations remove the main components related to your concern and confirm the effectiveness of our self-evolution mechanism. On the Lap, removing Coev.RL, and Memory ($E^+/E^-$) increased NIQE from 2.81 to 3.23, 3.05, and 3.18;decreased CLIPIQA from 0.394 to 0.341, 0.352, and 0.331; decreased ACC from 0.892 to 0.879, 0.882, and 0.878; and decreased DICE from 0.781 to 0.772, 0.772, and 0.768. Fig5 and Tab7 further show progressive improvements in biological-fidelity metrics and downstream performance across evolutionary stages, consistent with Reviewer 8Et7’s observation. We will also add stage-wise qualitative visualizations in the final version to address any remaining concerns.\n\t\t\nWe further provide results from two additional ablation experiments(IHC2Lap): (i) removing MicroNavigator and applying a fixed plan (FIX); and (ii) using Qwen3-VL to provide prior knowledge of biological microscopy and the plan (VLP). \n\n| | NIQE ↓ | CLIP ↑ | ACC ↑ | DICE ↑ |\n| -------------- | ------ | ------ | ----- | ------ |\n| FIX | 3.56 | 0.321 | 0.783 | 0.694 |\n| VLP | 3.29 | 0.351 | 0.850 | 0.738 |\n| ours | 2.81 | 0.394 | 0.892 | 0.781 |\n\nWe also report the effect of Coev.-RL on the number of rollbacks, as shown below.\n\n| | with Coev.-RL | without Coev.-RL |\n| ------- | ------------- | ---------------- |\n| Rollout | 1.12 | 3.67 |\n\nIn the comparative experiments, comparisons with individual strong expert models already demonstrate the contributions of our agentic framework and co-evolution (Tab 1–3). We further conducted an additional ablation study by removing strong expert models and evaluating the resulting framework performance.\n\n| Task (IHC2Lap) | NIQE ↓ | CLIP ↑ | SSIM ↑ | PSNR ↑ | Dice ↑ | ACC ↑ |\n| -------------- | ------ | ------ | ------ | ------ | ------ | ----- |\n| -MicroEdit-VS | 2.85 | 0.391 | 0.910 | 35.05 | 0.779 | 0.892 |\n| -MicroEdit-SR | 2.87 | 0.388 | 0.906 | 34.94 | 0.778 | 0.887 |\n| ours | 2.81 | 0.394 | 0.912 | 35.12 | 0.781 | 0.892 |\n\nThese results indicate that our framework is not heavily dependent on the performance of individual strong expert models.\n\n2. **Segmentation Model and OOD Data**\n\nSegmentation is not a bottleneck in our task. We use a fine-tuned SAM3 model, and because we have established a unified data interface using Pydantic, the current segmentation module can be flexibly replaced.\n\nTo address the OOD concern, we evaluated our model on diverse biological microscopy datasets spanning different tissues, cell types, imaging modalities, staining, degradation types, and acquisition conditions. We believe that the commonly used types in the biological domain have already been covered. As noted in the Conclusion (Section 5), we are collaborating to collect dataset and establish a test set. It currently contains 112 Masson stained tissue images of the murine glenohumeral joint, with results.\n\n| Task | Metric | AgenticIR | 4KAgent | BioMicroAgents |\n| ------- | ------ | --------- | ------- | -------------- |\n| SR4X | SSIM ↑ | 0.79 | 0.82 | 0.86 |\n| | PSNR ↑ | 30.63 | 31.02 | 31.87 |\n| | NIQE ↓ | 4.35 | 4.08 | 3.56 |\n| | CLIP ↑ | 0.34 | 0.38 | 0.44 |\n| Denoise | SSIM ↑ | 0.86 | 0.86 | 0.91 |\n| | PSNR ↑ | 34.94 | 35.12 | 35.96 |\n| | NIQE ↓ | 2.89 | 2.84 | 2.35 |\n| | CLIP ↑ | 0.37 | 0.39 | 0.47 |\n| Deblur | SSIM ↑ | 0.85 | 0.88 | 0.92 |\n| | PSNR ↑ | 33.72 | 34.29 | 35.34 |\n| | NIQE ↓ | 3.24 | 3.28 | 2.67 |\n| | CLIP ↑ | 0.38 | 0.37 | 0.46 |\n\nAlthough Masson is absent from the training set, BioMicroAgents can leverage RAG to improve performance. These additional results do not alter the main design or conclusions.\n\n3. **Microscopy image may not warrant such a complex system,the improvements are negligible**\n\nMicroscopy image processing and evaluation are complex and time-consuming. Traditional workflows often rely on repeated acquisition or manual extraction of usable regions, causing substantial waste[13,14]. Tasks such as super-resolution and multi-stain virtual staining have proven beneficial for downstream biological analysis and are inherently interconnected. Therefore, processing them independently and without supervision is inefficient, unsafe, and burdensome for experts. Although the improvements in some perceptual metrics are limited, we achieve strong performance on biologically relevant downstream tasks accepted by domain experts [13], consistent with our design principle.\n \nWe have added comparative experiments involving human experts, together with questionnaire-based statistical analyses, to further validate the effectiveness of our method. Due to the word limit, We will provide the detailed design later.\n\nTuring Test:\n\n| Expert | Real (90) | SwinIR (30) | 4KAgent (30) | BioMicroAgents (30) | Sensitivity | Overall Accuracy |\n| ------------------ | --------- | ----------- | ------------ | ------------------- | ----------- | ---------------- |\n| 1 | 27/90 | 21/30 | 29/30 | 16/30 | 0.733 | 0.717 |\n| 2 | 6/90 | 12/30 | 28/30 | 7/30 | 0.522 | 0.728 |\n| 3 | 42/90 | 17/30 | 30/30 | 9/30 | 0.622 | 0.578 |\n| AI Pass Rate | – | 0.444 | 0.033 | 0.644 | – | – |\n| Standard Deviation | – | 0.150 | 0.033 | 0.158 | – | – |\n\nScoring evaluation: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.\n\n| Expert | Scoring Rubric | DiffBIR + ImageEdit (50) | 4KAgent + ImageEdit (50) | BioMicroAgents (50) |\n| ------ | ---------------- | -----------------------: | -----------------------: | ------------------: |\n| 1 | Quality | 3.68/0.59 | 3.92/0.28 | 4.24/0.23 |\n| | Artifact | 2.86/0.33 | 3.10/0.30 | 4.08/0.32 |\n| | Constructiveness | 2.94/0.63 | 3.52/0.54 | 4.10/0.30 |\n| 2 | Q | 3.86/0.34 | 3.74/0.69 | 4.36/0.24 |\n| | A | 3.08/0.32 | 2.94/0.34 | 4.20/0.26 |\n| | C | 3.28/0.74 | 3.16/0.63 | 4.34/0.23 |\n| 3 | Q | 3.58/0.78 | 4.02/0.26 | 4.18/0.35 |\n| | A | 2.64/1.09 | 3.26/0.48 | 3.98/0.43 |\n| | C | 2.82/0.76 | 3.70/0.62 | 4.06/0.38 |\n\nSwap experiment: Experts were divided into AB groups to count cells in either original or AI images, and accuracy was calculated. The groups then switched conditions and evaluated unseen slides to avoid bias from prior exposure.\n\n| Expert | Origin | 4KAgent | ImageEdit | DiffBIR + ImageEdit | 4KAgent + ImageEdit | BioMicroAgents |\n| ------ | ------ | ------- | --------- | ------------------- | ------------------- | -------------- |\n| A-B | 0.787 | 0.715 | 0.812 | 0.627 | 0.684 | 0.823 |\n| B-A | 0.776 | 0.683 | 0.793 | 0.632 | 0.688 | 0.830 |\n\n4. **Unclear notation, grammatical errors and Introduction without ref**\n\nThank you for your careful and thorough review. We revised the manuscript to correct grammatical and spelling errors, improved the presentation and descriptions of the equations in the Methods section, and added the necessary equations and notation to the revised Fig. 1 for clearer understanding. We also added the relevant citations in the Related Work section for the content discussed in the Introduction.\n\n5. **Reproduce and the specific prompts**\n\nBioMicroAgents does not rely on any inaccessible proprietary components. The appendix B/D provides more details. The prompts are provided in Appendix C. We commit to releasing the code publicly upon acceptance."+ },+ "createdAt": "2026-07-28T11:15:10.226Z",+ "modifiedAt": "2026-11-18T17:19:08.500Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=Rt1sFGfDG8",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/s8ajzkfdvp.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/s8ajzkfdvp.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "s8aJzKfDVp",+ "replyTo": null,+ "kind": "meta_review",+ "invitation": "Meta_Review",+ "signature": "Area Chair 7qtq",+ "content": {+ "metareview": "The paper proposes BioMicroAgents, which reframes microscopy image processing from a one-shot mapping problem as a closed-loop workflow and introduces three biological-fidelity metrics. It reports strong results across super-resolution, virtual staining, low-light enhancement, denoising, and deblurring, and claims improvements in both perceptual quality and downstream tasks such as segmentation and cell counting. Microscopy image processing should preserve biological fidelity rather than optimize perceptual quality alone. Modeling the process as a closed loop of planning, execution, verification, and rollback is therefore well motivated. The experimental scope is broad, covering super-resolution, virtual staining, denoising, deblurring, and low-light enhancement. \n\nThe system is highly complex, but the necessity of this complexity is not sufficiently established. Because many mechanisms are introduced simultaneously, it remains unclear which component addresses which failure mode and how the system fails when that component is removed. Despite its substantial engineering effort, the paper provides few clear empirical takeaways. Computational cost is not adequately reported. Given the complexity of the framework, its inference overhead is likely substantial, and the paper should clarify whether the performance gains justify the additional cost and deployment complexity. Morphology overlap, color consistency, and texture similarity capture only partial proxy attributes and do not necessarily establish biological correctness."+ },+ "createdAt": "2026-07-26T05:24:34.759Z",+ "modifiedAt": "2026-11-18T15:23:36.995Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=s8aJzKfDVp",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/u957wcrsgv.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/u957wcrsgv.json@@ -0,0 +1,32 @@+{+ "schema": "review/1",+ "id": "u957WcrSgV",+ "replyTo": null,+ "kind": "review",+ "invitation": "Official_Review",+ "signature": "Reviewer 8Et7",+ "content": {+ "summary": "The authors propose BioMicroAgents, a multi-agent framework that models microscopy image processing as an iterative workflow involving planning, execution, verification, and experience accumulation. The framework consists of three interacting components: MicroNavigator, which uses multimodal retrieval and memory to generate processing plans; MicroProcessor, which dynamically invokes specialized image-processing models; and MicroAuthenticator, which evaluates biological fidelity using morphology-, color-, and texture-based criteria and provides feedback through a reinforcement learning-based co-evolution mechanism. The authors further introduce microscopy-specific fidelity metrics and a memory system that stores successful and failed processing trajectories. The paper evaluates the framework across multiple microscopy restoration and image translation tasks and reports improvements in both image quality and downstream analysis performance, including segmentation and cell counting. The work in general is interesting in topic selection and should be considered for acceptance.",+ "contribution_type": "general",+ "strengths_and_weaknesses": "The paper tackles an ambitious and practically important problem in biological microscopy imaging: how to coordinate multiple image processing operations, including super-resolution, denoising, deblurring, low-light enhancement, and virtual staining, while preserving biological fidelity. Rather than treating these tasks independently, the authors formulate microscopy image processing as a closed-loop workflow involving planning, execution, verification, rollback, and experience accumulation. To achieve this, they propose BioMicroAgents, a multi-agent framework composed of a planning agent (MicroNavigator), an execution agent (MicroProcessor), and a verification agent (MicroAuthenticator), together with multimodal retrieval, memory, and reinforcement learning-based co-evolution.\n\nA major strength of the paper is its attempt to move beyond single-task image restoration. Biological imaging workflows are often iterative and involve multiple processing stages, making the proposed agent-based formulation conceptually appealing. The integration of retrieval, memory, verification, and rollback mechanisms is well motivated by how human experts interact with microscopy data. I also appreciate the authors' emphasis on biological fidelity rather than solely optimizing perceptual image quality. The proposed fidelity metrics based on morphology, color consistency, and texture authenticity are biologically motivated, and the inclusion of downstream segmentation and cell-counting evaluations is a positive step toward assessing practical utility.\n\nThe experimental scope is broad. The framework is evaluated across multiple microscopy tasks and datasets, including super-resolution, virtual staining, denoising, deblurring, and low-light enhancement. Compared with recent image restoration and agentic image-processing methods, the reported results are generally strong, and the ablation studies suggest that both the co-evolution mechanism and memory components contribute to performance improvements.\n\nHowever, I have several concerns regarding both the technical contribution and the experimental validation.\n\nFirst, it is often difficult to identify which component is primarily responsible for the observed gains. The proposed framework combines many ingredients simultaneously: multimodal RAG, memory retrieval, planning agents, verification agents, custom fidelity metrics, reinforcement learning, rollback mechanisms, and specialized expert models. While the paper includes component ablations, the overall system is highly complex, making it challenging to disentangle whether the improvements stem from the agentic framework itself or from incorporating stronger underlying image restoration and generation models.\n\nSecond, the notion of \"co-evolution\" appears somewhat overstated. In practice, the interaction largely consists of a verification module providing rewards and feedback to a processing module, together with memory updates that influence future planning. While useful, this resembles a feedback-driven optimization loop more than the stronger notion of co-evolving agent policies. The paper would benefit from a clearer discussion of what distinguishes its formulation from existing agent-verifier or RL-based refinement frameworks.\n\nThird, although the proposed biological fidelity metrics are intuitively reasonable, it remains unclear whether they truly capture biological correctness. Metrics such as color consistency, segmentation overlap, and texture similarity may correlate with image quality, but they do not necessarily guarantee that biologically meaningful structures are preserved. This concern is particularly important for virtual staining and super-resolution tasks, where hallucinated features may appear plausible while being biologically incorrect.\n\nFourth, the evaluation focuses primarily on image-level metrics and downstream segmentation/counting performance. There is limited evidence that domain experts would prefer the generated results or consider them biologically more trustworthy. Given the paper's emphasis on biological fidelity, some form of expert assessment or biological validation would substantially strengthen the results/claims.\n\nFinally, the framework is computationally heavy and operationally complex. It combines multiple foundation models, retrieval systems, memory mechanisms, and RL-based optimization. The paper does not sufficiently discuss computational costs, deployment complexity, or whether the gains justify the additional system overhead compared to simpler task-specific approaches.\n\nThe work presents an ambitious and creative agentic framework tailored to microscopy imaging workflows. The motivation is compelling, the evaluation is extensive, and the idea of integrating planning, memory, verification, and biological constraints is interesting. However, the current presentation does not fully establish that the complexity of the proposed multi-agent system is necessary, nor does it completely validate that the proposed fidelity mechanisms reliably preserve biological correctness. Stronger evidence regarding the unique benefits of the agentic design and more direct biological validation would strengthen the paper considerably.",+ "quality": 3,+ "clarity": 3,+ "significance": 3,+ "originality": 3,+ "questions": "1. Can the authors provide stronger evidence that the agentic framework itself is responsible for the observed gains?\n\nThe proposed system combines multiple components, including multimodal RAG, memory, rollback mechanisms, custom fidelity metrics, reinforcement learning, and strong underlying restoration/generation models. While the ablation studies are helpful, it remains difficult to determine which components contribute most to performance improvements. Additional analysis clarifying the relative contribution of the agentic workflow versus the underlying expert models would strengthen the paper.\n\n2. What distinguishes the proposed co-evolution mechanism from existing agent-verifier or feedback-based optimization frameworks?\n\nThe paper repeatedly emphasizes co-evolution between MicroNavigator, MicroProcessor, and MicroAuthenticator. However, the interaction appears largely driven by reward feedback and memory updates. Could the authors clarify the conceptual and empirical differences between their formulation and existing agent-verifier or RL-based refinement frameworks? \n\n3. How well do the proposed biological fidelity metrics correlate with actual biological correctness?\n\nThe proposed metrics (Cellular Morphological Integrity, Chromatographic Consistency, and Histological Texture Authenticity) are biologically motivated and constitute an important part of the framework. However, it remains unclear whether improvements in these metrics correspond to improved biological validity. \n\n4. Can the authors provide evidence that the generated outputs are preferred by domain experts?\n\n\n5. Will the datasets, memory traces, and code be publicly released?",+ "limitations": "The authors acknowledge the limited scale and diversity of the available datasets and note that broader validation remains future work. However, several important limitations are not sufficiently discussed. First, the framework relies on a large number of interacting components, including retrieval systems, memory modules, reinforcement learning, verification metrics, and multiple expert models, yet the computational cost and deployment complexity of the full system are not analyzed. Second, the paper assumes that the proposed biological fidelity metrics correlate with biological correctness, but the limitations of these proxy metrics and their potential failure modes are not discussed. Third, for tasks such as super-resolution and virtual staining, the possibility of generating biologically plausible but incorrect structures should be explicitly acknowledged, particularly if the outputs are intended to support downstream scientific or clinical interpretation. Finally, the paper would benefit from a discussion of reproducibility, including dataset availability and the practical challenges of reproducing a complex multi-agent workflow.",+ "rating": 5,+ "confidence": 4,+ "ethical_concerns": [+ "NO or VERY MINOR ethics concerns only"+ ],+ "paper_formatting_concerns": "NA",+ "code_of_conduct_acknowledgement": "Yes",+ "responsible_reviewing_acknowledgement": "Yes",+ "final_justification": "After considering the authors' rebuttal and additional experimental results, I have made my recommendation to accept.\n\n-The authors provided extra evidence that the proposed agentic framework, rather than only the underlying foundation models, contributes to the observed performance gains. The additional ablations (e.g., removing key expert models, fixed planning, VLP planning, and Coev.-RL) consistently demonstrate the importance of the collaborative multi-agent design.\n-The rebuttal clarified how the proposed co-evolution mechanism differs from conventional planner/verifier or feedback-based frameworks. The explanation of the coupled optimization between the navigator and processor, together with the additional rollback analysis, better motivates the proposed design.\n-My concern regarding biological fidelity was partially addressed. While the proposed metrics remain proxy measures rather than guarantees of biological correctness, the newly provided expert evaluations, Turing test, and downstream validation offer stronger empirical evidence that the generated results are biologically meaningful.\n-The authors also clarified their plans for releasing the datasets and code and provided additional discussion on computational complexity and deployment trade-offs.\n\nSome limitations remain, including the lack of formal guarantees for biological correctness and the increased computational overhead of the framework. However, these concerns are outweighed by the strengthened empirical validation, the practical relevance of the problem, and the potential impact of the proposed framework. Overall, I believe the revised paper meets the bar for an accept recommendation."+ },+ "createdAt": "2026-06-22T10:21:00.113Z",+ "modifiedAt": "2026-11-18T13:42:31.669Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=u957WcrSgV",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/notes/yw7ipy06yi.json added
+++ b/reviews/openreview/2ibxepvy2x/notes/yw7ipy06yi.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Yw7ipy06YI",+ "replyTo": "u957WcrSgV",+ "kind": "comment",+ "invitation": "Rebuttal",+ "signature": "Authors",+ "content": {+ "rebuttal": "Thank you for your careful and constructive review. Below, we address each of your concerns.\n\n1. **Can the authors provide stronger evidence that the agentic framework itself is responsible for the observed gains?**\n\nOur core insight is to model the professional biological microscopy imaging workflow as a collaborative multi-agent process that emulates how experts iteratively observe, validate, and adjustment. The ablation in Table 7 modify only the workflow mechanisms while keeping the task settings. On the HE virtual staining task, removing RL-based co-evolution decreases CLIPIQA from 0.435 to 0.363 and ACC from 0.895 to 0.883. Removing multimodal RAG decreases ACC from 0.895 to 0.871 and DICE from 0.782 to 0.738. Removing memories likewise degrades the primary biological-fidelity and downstream-task metrics. Furthermore, in the experiment shown in Fig. 5(b), all model parameters were frozen, and memory write-back was disabled during testing. This design disentangles the benefits of historical memory retrieval from those attributable to a stronger parameterized model. The experiment in Fig. 5(a) further demonstrates the effect of the co-evolution process on performance. Notably, some of the strong underlying expert models used in our framework, such as Qwen-VL, were also included in the baseline comparisons, naturally providing an additional ablation-like evaluation. Nevertheless, our full model still achieved superior results, as shown in Tables 1 and 3.\n\nWe further conducted an additional ablation study by removing several strong expert models.\n\n| Task (IHC2Lap) | NIQE ↓ | CLIPIQA ↑ | SSIM ↑ | PSNR ↑ | Dice ↑ | ACC ↑ |\n| -------------- | ------ | --------- | ------ | ------ | ------ | ----- |\n| -MicroEdit-VS | 2.85 | 0.391 | 0.910 | 35.05 | 0.779 | 0.892 |\n| -MicroEdit-SR | 2.87 | 0.388 | 0.906 | 34.94 | 0.778 | 0.887 |\n| BioMicroAgents | 2.81 | 0.394 | 0.912 | 35.12 | 0.781 | 0.892 |\n\nWe further provide results from two additional ablation experiments: (i) removing MicroNavigator and applying a fixed plan (FIX); and (ii) using Qwen3-VL to provide prior knowledge of biological microscopy and the plan (VLP). \n\n| Task (IHC2Lap) | NIQE ↓ | CLIPIQA ↑ | ACC↑ | DICE ↑ |\n| -------------- | ------ | --------- | ----- | ------ |\n| FIX | 3.56 | 0.321 | 0.783 | 0.694 |\n| VLP | 3.29 | 0.351 | 0.850 | 0.738 |\n| BioMicroAgents | 2.81 | 0.394 | 0.892 | 0.781 |\n\n2. **How does the proposed “co-evolution” mechanism differ from existing verifier- or feedback-based optimization frameworks?**\n\nUnlike conventional unidirectional verifier–executor loops that provide only post hoc scores, or isolated reward optimization, BioMicroAgents enables biological-fidelity-driven co-adaptation by jointly optimizing $\\pi_p$ and $\\pi_n$ under rigorous verification. This design mirrors expert workflows and is further tailored to the biological domain (Eq. 6, Fig. 2).\n\nIn this work, co-evolution refers to the coupled improvement of different groups of agents. This coupling is achieved through two pathways:\n\t(1) MicroAuthenticator converts biological-fidelity evaluations into rewards that are used to optimize the processor policy, $\\pi_p$.\n\t(2) The feedback—including evaluation scores, failure reasons, erroneous regions, and processing trajectories—is stored as experience and retrieved in subsequent tasks to improve the navigator policy $\\pi_n$.\nThe effectiveness of the proposed method is further demonstrated by the ablation studies(tab.7). \n\nMoreover, our additional experiments further demonstrate how our approach differs from existing planner-processer–verifier frameworks.\n\n| Task (IHC2Lap) | NIQE ↓ | CLIPIQA ↑ | ACC ↑ | DICE ↑ |\n| -------------- | ------ | --------- | ----- | ------ |\n| FIX | 3.56 | 0.321 | 0.783 | 0.694 |\n| VLP | 3.29 | 0.351 | 0.850 | 0.738 |\n| BioMicroAgents | 2.81 | 0.394 | 0.892 | 0.781 |\n\nWe also report the effect of Coev.-RL on the number of rollbacks, as shown below.\n\n| | with Coev.-RL | without Coev.-RL |\n| ------- | ------------- | ---------------- |\n| Rollout | 1.12 | 3.67 |\n\n\n3. **Can the proposed biological-fidelity metrics guarantee biological correctness? Are the generated results more favorably evaluated by domain experts?**\n\nWe agree that the metrics proposed in this work are proxy measures of biological fidelity, however, they are biologically meaningful. They are designed to capture complementary failure modes that conventional perceptual-quality metrics may overlook:\n- $H_{\\mathrm{CMI}}$ evaluates cellular morphological integrity;\n- $H_{\\mathrm{CC}}$ evaluates staining consistency \n- $H_{\\mathrm{HTA}}$ evaluates the histological textures.\n\nDuring validation, these metrics are combined with perceptual-quality measures and downstream segmentation and cell-counting results, since visually plausible outputs may still alter cell boundaries, hallucinate subcellular textures, or distort biologically meaningful staining patterns. Such downstream validation is well established and widely used in prior studies (e.g., [13, 14]).\n\nWe conducted additional evaluations involving independent human experts and report the corresponding rating-scale statistics to further validate our experimental findings. \n\nTuring Test: \n\n| Expert | Real (90) | SwinIR (30) | 4KAgent (30) | BioMicroAgents (30) | Sensitivity | Overall Accuracy |\n| ------------------ | --------- | ----------- | ------------ | ------------------- | ----------- | ---------------- |\n| 1 | 27/90 | 21/30 | 29/30 | 16/30 | 0.733 | 0.717 |\n| 2 | 6/90 | 12/30 | 28/30 | 7/30 | 0.522 | 0.728 |\n| 3 | 42/90 | 17/30 | 30/30 | 9/30 | 0.622 | 0.578 |\n| AI Pass Rate | – | 0.444 | 0.033 | 0.644 | – | – |\n| Standard Deviation | – | 0.150 | 0.033 | 0.158 | – | – |\n\nScoring evaluation: The scoring rubric evaluates the images across three dimensions: image quality, artifacts, and usefulness for biological assessment. Each dimension is rated on a scale from 1 to 5.\n\n| Expert | Scoring Rubric | DiffBIR + ImageEdit (50) | 4KAgent + ImageEdit (50) | BioMicroAgents (50) |\n| ------ | ---------------- | -----------------------: | -----------------------: | ------------------: |\n| 1 | Quality | 3.68/0.59 | 3.92/0.28 | 4.24/0.23 |\n| | Artifact | 2.86/0.33 | 3.10/0.30 | 4.08/0.32 |\n| | Constructiveness | 2.94/0.63 | 3.52/0.54 | 4.10/0.30 |\n| 2 | Q | 3.86/0.34 | 3.74/0.69 | 4.36/0.24 |\n| | A | 3.08/0.32 | 2.94/0.34 | 4.20/0.26 |\n| | C | 3.28/0.74 | 3.16/0.63 | 4.34/0.23 |\n| 3 | Q | 3.58/0.78 | 4.02/0.26 | 4.18/0.35 |\n| | A | 2.64/1.09 | 3.26/0.48 | 3.98/0.43 |\n| | C | 2.82/0.76 | 3.70/0.62 | 4.06/0.38 |\n\nSwap experiment: Experts were divided into AB groups to count cells in either original or AI images, and accuracy was calculated. The groups then switched conditions and evaluated unseen slides to avoid bias from prior exposure.\n\n| Expert | Origin | 4KAgent | ImageEdit | DiffBIR + ImageEdit | 4KAgent + ImageEdit | BioMicroAgents |\n| ------ | ------ | ------- | --------- | ------------------- | ------------------- | -------------- |\n| A-B | 0.787 | 0.715 | 0.812 | 0.627 | 0.684 | 0.823 |\n| B-A | 0.776 | 0.683 | 0.793 | 0.632 | 0.688 | 0.830 |\n\n4. Will the datasets, memory traces, and code be publicly released?\n\nYes. Most of the datasets used in our experiments are publicly available, and the manuscript reports the dataset splits and computational environments for the different tasks.The AppendixB also provides the main configurations of the RAG and memory. A mini version of the proposed MicroBrighten dataset has been submitted as supplementary material, and its scale and composition are described in the appendix. The complete version will be released subsequently.\n\n5. Computational and deployment complexity\n\nRAG, memory, and rigorous verifier-based fidelity checks introduce additional computational overhead compared with conventional multi-agent methods such as 4KAgent (106.31 s). However, microscopy image processing prioritizes fidelity over efficiency, and reducing cost at the expense of artifacts is unacceptable, as shown in Appendix D. For 4× tasks, with each workflow including a valid virtual-staining step, we performed inference on an NVIDIA PRO 6000 GPU:\n\n| Model | MircoNavigator | | | MircoProcessor | MircoAuthenticator | Total |\n| --------- | -------------- | ----- | ----- | -------------- | ------------------ | ----- |\n| Component | RAG | Mem | Plan | Process | Verify | |\n| Time(s) | 51.32 | 23.74 | 16.96 | 35.63 | 12.58 | 140.2 |\n \nWhen biological-fidelity metrics are used for verification, 4KAgent triggers frequent artifact-induced rollbacks, increasing computational complexity. Our method reduces these repeated rollbacks and achieves more efficient inference under the same fidelity requirements."+ },+ "createdAt": "2026-07-28T11:18:59.187Z",+ "modifiedAt": "2026-11-18T17:19:08.501Z",+ "url": "https://openreview.net/forum?id=2IBxEPvy2X¬eId=Yw7ipy06YI",+ "license": "CC-BY-4.0"+}
reviews/openreview/2ibxepvy2x/submission.json added
+++ b/reviews/openreview/2ibxepvy2x/submission.json@@ -0,0 +1,12 @@+{+ "schema": "submission/1",+ "id": "2IBxEPvy2X",+ "venue": {+ "id": "NeurIPS.cc/2026/Conference",+ "name": "NeurIPS 2026",+ "url": "https://openreview.net/group?id=NeurIPS.cc%2F2026%2FConference"+ },+ "number": 23870,+ "url": "https://openreview.net/forum?id=2IBxEPvy2X",+ "license": "CC-BY-4.0"+}
versions/v_q78tny2z.json added
+++ b/versions/v_q78tny2z.json@@ -0,0 +1,22 @@+{+ "date": "2026-05-04",+ "kind": "submitted",+ "label": "NeurIPS 2026",+ "submissions": [+ {+ "venue": "NeurIPS 2026",+ "status": "accepted",+ "decision": "Accept (poster)",+ "number": 23870,+ "url": "https://openreview.net/forum?id=2IBxEPvy2X",+ "reviews": "openreview/2ibxepvy2x",+ "evidence": [+ "https://openreview.net/forum?id=2IBxEPvy2X"+ ]+ }+ ],+ "url": "https://openreview.net/forum?id=2IBxEPvy2X",+ "evidence": [+ "https://openreview.net/forum?id=2IBxEPvy2X"+ ]+}