Update NeurIPS 2026 submission Zpjtkfd60y: 3 notes
@openreview[bot] · 2026-11-24 15:52 UTC · cb44224bd54f ·
reviews/openreview/zpjtkfd60y/notes/fmo2c4gnqt.json modified
+++ b/reviews/openreview/zpjtkfd60y/notes/fmo2c4gnqt.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair HF85","content": {- "metareview": "The reviewers recognize the paper as a well-motivated and technically plausible framework for left-ventricular echocardiography video segmentation. However, the current discussion hinges on whether the evidence sufficiently supports the paper’s main claims. At this stage, the authors should focus the rebuttal on the following points, which are most relevant to the final discussion:\n1. Please address Reviewer 2abz’s concern about the clinical significance of the reported gains.\n2. Please address Reviewer w9sD’s concern about the strength of the evidence for the proposed “What Where Boundary” cognitive decomposition. \n3. Please respond to Reviewer Eyad’s and Reviewer w9sD’s concerns regarding the dependence on the first-frame anchor.\n4. Please address Reviewer 2abz’s and Reviewer w9sD’s concerns about the fairness and interpretability of the empirical comparisons."+ "metareview": "The reviewers recognize the paper as a well-motivated and technically plausible framework for left-ventricular echocardiography video segmentation. However, the current discussion hinges on whether the evidence sufficiently supports the paper’s main claims. At this stage, the authors should focus the rebuttal on the following points, which are most relevant to the final discussion:\n1. Please address Reviewer 2abz’s concern about the clinical significance of the reported gains.\n2. Please address Reviewer w9sD’s concern about the strength of the evidence for the proposed “What Where Boundary” cognitive decomposition. \n3. Please respond to Reviewer Eyad’s and Reviewer w9sD’s concerns regarding the dependence on the first-frame anchor.\n4. Please address Reviewer 2abz’s and Reviewer w9sD’s concerns about the fairness and interpretability of the empirical comparisons.",+ "final_justification": "In the rebuttal, the authors resolved most of the concerns raised by the reviewers. Given its strong empirical validation and clear practical utility, the paper is recommended for acceptance."},"createdAt": "2026-07-22T07:45:17.550Z",- "modifiedAt": "2026-11-18T15:23:39.462Z",+ "modifiedAt": "2026-11-19T05:02:17.242Z","url": "https://openreview.net/forum?id=Zpjtkfd60y¬eId=Fmo2c4gnQt","license": "CC-BY-4.0"}
reviews/openreview/zpjtkfd60y/notes/kukw0glvxz.json added
+++ b/reviews/openreview/zpjtkfd60y/notes/kukw0glvxz.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "KuKW0gLvXz",+ "replyTo": "hyrSqGgUTL",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Figure 3: the underlying per-patient LVEF values",+ "comment": "As requested, below are all 50 per-patient LVEF values underlying Fig. 3 and the Table 2 entry for HCD. Identifiers are the public CAMUS test-split patient IDs; ground-truth LVEF is computed from the released CAMUS annotations with the same Simpson's-rule implementation as in the paper. These predictions come from the submitted single-structure checkpoint.\n\n```\npatient0027 40.64 39.49 patient0227 60.70 51.61\npatient0047 41.13 37.45 patient0228 45.14 38.88\npatient0051 33.93 28.33 patient0231 50.86 44.63\npatient0052 18.75 5.56 patient0234 48.90 43.88\npatient0187 40.02 38.47 patient0237 57.64 55.88\npatient0189 75.40 69.33 patient0238 43.15 35.39\npatient0191 28.06 26.48 patient0239 55.75 53.01\npatient0194 60.59 63.05 patient0240 39.07 32.05\npatient0197 59.64 57.81 patient0241 48.39 30.11\npatient0199 57.96 59.36 patient0242 46.08 49.76\npatient0201 41.36 42.12 patient0243 58.90 55.22\npatient0208 51.29 45.45 patient0246 51.04 48.03\npatient0213 46.55 38.48 patient0248 49.50 50.11\npatient0214 42.06 44.16 patient0251 66.28 56.15\npatient0215 58.87 52.41 patient0252 54.44 43.52\npatient0217 43.78 49.95 patient0254 48.70 45.04\npatient0218 29.75 19.40 patient0258 48.28 46.53\npatient0219 60.06 52.29 patient0260 51.07 51.56\npatient0220 51.43 48.12 patient0261 48.85 45.61\npatient0221 53.57 51.94 patient0262 48.90 41.36\npatient0223 56.78 56.72 patient0263 59.96 65.92\npatient0224 37.09 37.35 patient0266 36.08 25.83\npatient0225 59.34 46.25 patient0269 51.87 48.85\npatient0226 63.18 60.07 patient0273 33.57 26.86\n patient0275 56.49 46.72\n patient0276 31.12 30.00\n```\n\n(each triplet: patient ID, predicted LVEF, ground-truth LVEF; LVEF values are in percentage points)\n\nFor d = predicted minus ground-truth LVEF, direct recomputation gives mean(d) = 4.1882 percentage points, SD(d) = 4.93 under the denominator-n convention of Table 2, Pearson r = 0.914, and the least-squares fit predicted = 0.81 x ground truth + 12.50. With the n-1 denominator, SD(d) is 4.98. Figure 3 reports the mean difference as 0.0419 in fractional LVEF units; Table 2 currently truncates 4.1882 to 4.18, and we will correct it to 4.19.\n\nThese predictions come from the submitted checkpoint underlying Fig. 3 and Table 2. The three-run segmentation summaries in our main reply come from independent retrainings performed for the rebuttal, which we ran to establish whether the gain is stable rather than relying on published values. Separately, the paired downstream analysis used a protocol-matched retrained HCD/GDKVM pair (HCD: 95.24 mDice / 2.557 mm HD95; GDKVM: 95.01 / 2.700 mm). That pair yielded LVEF MAE values of 4.33 versus 5.32 and 3/50 versus 9/50 patients with absolute LVEF error above 10 points. These values are not computed from the submitted-checkpoint list above, which yields an MAE of 5.14 and 7/50 such patients.\n\nWe apologize for the watermark. Fig. 3 was first generated from the values above using our plotting code. We then applied an AI-based super-resolution tool only to the rendered raster image; it inadvertently introduced the watermark, which we failed to notice. The enhanced image was not used to derive or alter any prediction, measurement, or statistic. We will replace it with a watermark-free vector plot generated directly from these values."+ },+ "createdAt": "2026-07-29T10:54:25.676Z",+ "modifiedAt": "2026-11-19T16:58:00.927Z",+ "url": "https://openreview.net/forum?id=Zpjtkfd60y¬eId=KuKW0gLvXz",+ "license": "CC-BY-4.0"+}
reviews/openreview/zpjtkfd60y/notes/rxgjzihxvi.json added
+++ b/reviews/openreview/zpjtkfd60y/notes/rxgjzihxvi.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "RXGJziHXVI",+ "replyTo": "Fmo2c4gnQt",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "title": "Response to the Area Chair: the four decision-relevant points",+ "comment": "We address the four points in order, full protocols and results are in the reviewer-specific replies.\n\n**1. Clinical significance of the reported gains.** Across three independent controlled runs under GDKVM's protocol, HCD reached 95.27+-0.03 mDice / 2.573+-0.025 mm HD95 versus 95.00+-0.04 / 2.703+-0.015 for GDKVM, ranking better in every run. Table 1's +- values describe frame-level dispersion, whereas these analyses evaluate run-to-run variability and uncertainty in paired patient-level effects. Accounting for correlated 2CH/4CH views, both paired effects favoured HCD (+0.23 mDice points, -0.143 mm HD95; Holm-adjusted p=0.077 for both). Error-tail and downstream measures pointed the same way but were likewise inconclusive; patients with absolute LVEF error above 10 points fell from 9/50 to 3/50. These results support a reproducible technical improvement, while clinical benefit requires larger-cohort validation. The contribution also rests on cost and scope: 1.35M trainable parameters (3.8% of the model) at 68 FPS on one RTX 2080 Ti, and a joint LV-cavity/myocardium/left-atrium model adding 585 trainable parameters that reaches 92.05+-0.09 macro mDice.\n\n**2. Evidence for the What-Where-Boundary decomposition.** The contribution is the explicit decomposition into target identity, spatial localization, and boundary delineation, not novelty in the lightweight operators instantiating it; it derives from the clinical reading workflow rather than from architecture search, so the controls below evaluate the design rather than define it. Our eight-configuration ablation covers every SIA/AGP/SBP combination: the full model is best on both metrics (95.21 mDice / 2.59 mm HD95), removing any one module worsens both, and the complete configuration improves on the no-module baseline by 1.22 mDice and 0.90 mm. Over three runs the sequential form beat a parallel variant on both metrics (95.27+-0.03 / 2.573+-0.025 mm versus 95.13+-0.02 / 2.727+-0.049 mm), and across all six stage orders the three placing localization before boundary refinement took the top three positions on both metrics. Margins among the leading orders were close, however, and exchanging identity conditioning with localization showed no consistent advantage. SIA and AGP attention maps and an SBP boundary-confidence comparison show each module acting where intended. We therefore claim the decomposition as implemented in HCD and a design preference for localization before boundary refinement, not a uniquely necessary order, and we do not claim that the architecture reproduces expert cognition.\n\n**3. Dependence on the first-frame anchor.** Degradation under an imperfect first-frame annotation is graded, monotonic in perturbation strength, and error-type dependent rather than all-or-nothing. Without retraining we perturbed only the annotation across five error families (anchor Dice = Dice against the first-frame ground-truth mask). For the submitted checkpoint, performance was 95.21 mDice / 2.59 mm HD95 with a clean anchor; at anchor Dice 0.90-0.92 the largest degradation across the five families was 2.20 mDice and 1.01 mm. Error type mattered more than anchor Dice alone: at 0.840 versus 0.838, systematic dilation cost 6.2 mDice points against 1.8 for irregular contour noise. A 14-pixel translation (anchor Dice 0.70) gave 85.9 mDice. This is consistent with SIA retrieving features softly rather than imposing the annotation as a hard pixel mask. In a further control, over three runs a fixed-crop variant reached 94.99+-0.05 mDice / 2.673+-0.032 mm against HCD's 95.27 / 2.573 mm, so in this implementation a fixed region of interest did not match identity conditioning.\n\n**4. Fairness and interpretability of the comparisons.** HCD is evaluated strictly under GDKVM's protocol: the same split, preprocessing, test cases, and metric implementation. Table 1's baseline values are therefore taken from GDKVM's published comparison table rather than assembled across papers with differing protocols, with E3SAM2 and EchoVim the only additions; as we did not reproduce those two, they will be labelled *Reported* from their original papers and used only as supplementary context. We also retrained HCD and GDKVM three times each under this protocol, each keeping its own architecture and optimization settings. Our GDKVM reproduction closely matched its published mDice (95.00+-0.04 versus 95.11) and achieved better HD95 (2.703+-0.015 versus 3.05 mm), so it was not uniformly weaker than the published result. The 68 FPS above and GDKVM's published 37 FPS come from different hardware and timing setups, so cross-hardware differences remain indicative rather than controlled.\n\nTogether these controls support a parameter-efficient, clinically motivated framework with reproducible gains and quantified anchor sensitivity."+ },+ "createdAt": "2026-07-29T09:43:34.699Z",+ "modifiedAt": "2026-11-19T16:58:00.851Z",+ "url": "https://openreview.net/forum?id=Zpjtkfd60y¬eId=RXGJziHXVI",+ "license": "CC-BY-4.0"+}