Aegis: Generative Gradient Masking for Privacy-Preserving Medical Federated Learning
Update NeurIPS 2026 submission vUlQnQztWO: 14 notes
@openreview[bot] · 2026-11-24 15:57 UTC · 5067fac39421 ·
reviews/openreview/vulqnqztwo/notes/6rwb2h8h8s.json modified
+++ b/reviews/openreview/vulqnqztwo/notes/6rwb2h8h8s.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair beB9","content": {- "metareview": "The authors tackle the problem of model inversion attacks in the context of federated learning; and motivate their work primarily for medical domain/applications. The proposal is based on gradient mixing strategy that relies on using a synthetic data at each client to generate fake/synthetic gradients that break the batch size limits when pooled across federation; which essentially drives non-identifiability of the input samples. The proposal is evaluated on various standard datasets (including 3 medical ones). \n\nThe paper received valuable feedback, and the reviewers highlighted various critical pieces. I would request the authors to take a read of the comments/questions and address them to improve the case for publication. Specifically, the comments are on missing technical details (e.g., hyperparameter choices/tuning on attack bins size), a potential missing baseline, clarity on generator configuration, and mainly the generalization capacity to more in the wild medical data beyond medMNIST and possibly needing more quantitative evidence here (especially given that the motivation is anchored on medical settings)."+ "metareview": "The authors tackle the problem of model inversion attacks in the context of federated learning; and motivate their work primarily for medical domain/applications. The proposal is based on gradient mixing strategy that relies on using a synthetic data at each client to generate fake/synthetic gradients that break the batch size limits when pooled across federation; which essentially drives non-identifiability of the input samples. The proposal is evaluated on various standard datasets (including 3 medical ones). \n\nThe paper received valuable feedback, and the reviewers highlighted various critical pieces. I would request the authors to take a read of the comments/questions and address them to improve the case for publication. Specifically, the comments are on missing technical details (e.g., hyperparameter choices/tuning on attack bins size), a potential missing baseline, clarity on generator configuration, and mainly the generalization capacity to more in the wild medical data beyond medMNIST and possibly needing more quantitative evidence here (especially given that the motivation is anchored on medical settings).",+ "final_justification": "The authors addressed the critical concerns and issues raised by the reviewers; specifically on the technical details, missing baseline and clarifications on evaluations setups/interpretations; and they provided sufficient evidence on generator capacity (related to generalization). There is still the question of level of impact for the work; but as things stand, the authors' made the case for publication. \n\nI request the authors to appropriately reflect any relevant changes/additions to the final camera ready (tables, results etc.) so we capture the commentary that happened here via author-reviewer discussions."},"createdAt": "2026-07-21T21:45:07.700Z",- "modifiedAt": "2026-11-18T15:23:46.760Z",+ "modifiedAt": "2026-11-19T05:02:21.680Z","url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=6RwB2h8H8S","license": "CC-BY-4.0"}
reviews/openreview/vulqnqztwo/notes/alhc1hibql.json added
+++ b/reviews/openreview/vulqnqztwo/notes/alhc1hibql.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ALHc1hIbql",+ "replyTo": "LxAv8xH0vW",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer hnbp",+ "content": {+ "comment": "Thank you for the authors’ response. Given the additional results, I have raised my score. However, the baseline comparison, trade-off curve, and medical-dataset accuracy should have been included in the original submission, not rebuttal. \nIf accepted, all rebuttal results and clarifications should be incorporated into the camera-ready version."+ },+ "createdAt": "2026-07-30T00:58:48.967Z",+ "modifiedAt": "2026-11-19T16:43:50.921Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=ALHc1hIbql",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/h1utzvlh9r.json added
+++ b/reviews/openreview/vulqnqztwo/notes/h1utzvlh9r.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "H1uTZVLH9R",+ "replyTo": "O03LbjS8y1",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the constructive comments.\n\n**1. Evaluation under realistic non-IID partitions**\n\nWe agree that non-IID evaluation is important. Following Li et al., *Federated Learning on Non-IID Data Silos: An Experimental Study*, we add distribution-based label skew with $p_c\\sim Dir(0.5)$ and $Dir(0.1)$, quantity-based label skew with two classes per client (#C=2), noise-based feature skew $x\\sim Gau(0.1)$, and quantity skew $q\\sim Dir(0.5)$. Our original setting is already non-IID and closest to their quantity-based label-skew family: 100 clients have disjoint data, each restricted to at most five classes, with 10% participation. All other settings remain fixed, including $B=64$, $M=2048$, and $k=1024$.\n\n**Table 1. Non-IID sensitivity of Aegis. ACC and RR are percentages.**\n\n| Partition | Chest ACC↑ | Chest RR↓ | Chest PSNR↓ | Chest SSIM↓ | OrganA ACC↑ | OrganA RR↓ | OrganA PSNR↓ | OrganA SSIM↓ | Path ACC↑ | Path RR↓ | Path PSNR↓ | Path SSIM↓ |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| Original: #C≤5 | 55.5 | 9.50 | 18.70 | 0.46 | 58.8 | 11.63 | 20.10 | 0.51 | 57.2 | 9.38 | 17.30 | 0.38 |\n| Label Dir(0.5) | 58.8 | 9.38 | 18.61 | 0.45 | 62.1 | 11.48 | 19.95 | 0.50 | 60.5 | 9.25 | 17.18 | 0.37 |\n| Label Dir(0.1) | 53.8 | 9.62 | 18.82 | 0.47 | 57.0 | 11.78 | 20.25 | 0.52 | 55.4 | 9.51 | 17.42 | 0.39 |\n| Label qty. #C=2 | 43.6 | 9.71 | 18.91 | 0.47 | 46.4 | 11.91 | 20.37 | 0.52 | 44.8 | 9.62 | 17.54 | 0.39 |\n| Feature Gau(0.1) | 59.5 | 9.94 | 19.05 | 0.48 | 62.8 | 12.08 | 20.51 | 0.53 | 61.2 | 9.78 | 17.72 | 0.40 |\n| Quantity Dir(0.5) | 60.2 | 9.44 | 18.66 | 0.46 | 63.5 | 11.57 | 20.04 | 0.51 | 61.9 | 9.34 | 17.28 | 0.38 |\n\nThe hard two-class constraint causes the largest ACC drop. Dirichlet label skew is milder at 0.5 and more concentrated at 0.1; feature and quantity skew retain broad label coverage and therefore outperform our original five-class cap. Defense data use only client-visible labels and remain within the same client-side distribution bound, so they do not remove the non-IID skew. Privacy remains stable because each partition retains $B+M>k$. We will cite the study and include these experiments.\n\n**2. Comparison with conditional secure aggregation**\n\nWe thank the reviewer for pointing us to this important work and will cite and discuss it. MPC-based secure aggregation hides each individual update as ciphertext; reconstruction instead operates on the plaintext aggregate/global update. That aggregate is numerically identical with or without secure aggregation, so an empirical comparison would reproduce the same RR/PSNR/SSIM. Conditional secure aggregation adds integrity checks against model inconsistency, whereas our threat model allows the server to send the same crafted model to all clients. The mechanisms therefore address complementary attack surfaces.\n\n**3. Evaluation beyond CNN backbones**\n\nWe replace the task backbone while retaining the original non-IID partition, $M=2048$, and the same crafted FC leakage front-end. All classifiers use dataset-native resolution and no classifier pretraining; the low-resolution ViT uses 4×4 patches.\n\n**Table 2. Backbone sensitivity under the same Aegis/Robbing-the-Fed setting**\n\n| Backbone | Chest ACC↑ | Chest RR↓ | Chest PSNR↓ | Chest SSIM↓ | OrganA ACC↑ | OrganA RR↓ | OrganA PSNR↓ | OrganA SSIM↓ | Path ACC↑ | Path RR↓ | Path PSNR↓ | Path SSIM↓ |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| 3-layer CNN | 55.5 | 9.50 | 18.70 | 0.46 | 58.8 | 11.63 | 20.10 | 0.51 | 57.2 | 9.38 | 17.30 | 0.38 |\n| ResNet-18 | 57.8 | 9.47 | 18.68 | 0.46 | 61.4 | 11.59 | 20.07 | 0.51 | 60.1 | 9.35 | 17.27 | 0.38 |\n| ViT-S/4 | 56.4 | 9.54 | 18.74 | 0.46 | 59.9 | 11.67 | 20.14 | 0.51 | 58.4 | 9.42 | 17.35 | 0.38 |\n| Swin-T | 57.2 | 9.49 | 18.69 | 0.46 | 60.7 | 11.61 | 20.09 | 0.51 | 59.4 | 9.37 | 17.29 | 0.38 |\n\nThe backbone changes ACC, whereas privacy metrics remain within run-to-run variation. Robbing-the-Fed reconstructs from the same crafted first-FC gradients. For an isolated bin, the downstream scalar occurs in both weight and bias gradients and cancels in their ratio. Under Aegis, $B+M>k$ forces real–synthetic collisions; the backbone may slightly reweight a collided mixture but does not change leakage-bin capacity. The defense is therefore not CNN-specific."+ },+ "createdAt": "2026-07-30T00:58:44.122Z",+ "modifiedAt": "2026-11-19T16:43:50.905Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=H1uTZVLH9R",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/jpe2uapedu.json added
+++ b/reviews/openreview/vulqnqztwo/notes/jpe2uapedu.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "JpE2uaPEDU",+ "replyTo": "R72yQKeSfX",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for your review and valuable feedback!"+ },+ "createdAt": "2026-08-01T17:52:12.340Z",+ "modifiedAt": "2026-11-19T16:43:49.443Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=JpE2uaPEDU",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/kp9nv3styq.json added
+++ b/reviews/openreview/vulqnqztwo/notes/kp9nv3styq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "kp9NV3STyQ",+ "replyTo": "H1uTZVLH9R",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer tAou",+ "content": {+ "comment": "Thanks for the answers:\n1. 3. My concerns are addressed.\n2. Thanks for the clarification. Please make it clear in the paper the difference between your Threat model (same global model for all clients) and that of [23] (different global model for some clients)."+ },+ "createdAt": "2026-07-30T09:27:00.085Z",+ "modifiedAt": "2026-11-19T16:43:50.914Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=kp9NV3STyQ",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/lxav8xh0vw.json added
+++ b/reviews/openreview/vulqnqztwo/notes/lxav8xh0vw.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "LxAv8xH0vW",+ "replyTo": "yEtoGOO9X5",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the constructive comments.\n\n**1. Lack of comparison with previous gradient-mixing work**\n\nWe completely agree and thank the reviewer for identifying Eloul et al.; we will cite and discuss this important precursor. As the reviewer notes, both works share the philosophy that gradient mixing reduces reconstruction: Eloul et al. mix private-sample gradients through the local training strategy, whereas Aegis adds an auxiliary-data gradient. The distinction is the attack regime and enforcement mechanism. Eloul et al. evaluate conventional optimization-based MIAs, while Table A.2 shows that utility-preserving changes to local training settings do not stop the state-of-the-art linear-leakage attack Robbing-the-Fed (SSIM remains 0.99 across batch sizes 32–128). Aegis explicitly adds task-relevant synthetic contributions so that the private plus defense batch exceeds the $k$ leakage bins, protecting against both attack families. We also evaluate their strongest configuration (MSE with same-label batching) under our unchanged FL and Robbing-the-Fed protocol. It preserves utility but only marginally reduces reconstruction because it does not enforce $B+M>k$. We will add this direct baseline and make the connection explicit.\n\n**2. Medical utility is not evaluated**\n\nWe now report final accuracy under the same 100-client non-IID FedAvg setting. Aegis closely matches no defense, while perturbation/pruning defenses incur larger losses.\n\n**Table 1. Final medical test accuracy (%)**\n\n| Defense | Chest | OrganA | Path |\n|---|---:|---:|---:|\n| None | 55.8 | 58.6 | 57.3 |\n| Eloul et al. | 55.7 | 58.5 | 57.2 |\n| Aegis | 55.5 | 58.8 | 57.2 |\n| Soteria | 53.8 | 56.6 | 55.3 |\n| GC | 51.9 | 54.7 | 53.4 |\n| GD | 47.2 | 50.0 | 48.7 |\n| Outpost | 49.0 | 51.8 | 50.5 |\n| DP | 44.7 | 47.5 | 46.2 |\n\nWe will include the corresponding round-to-accuracy curves in the revision.\n\n**3. Lack of generator analysis**\n\nThe reported pipeline is identical across MNIST, CIFAR-10, and the three MedMNIST modalities: public Stable Diffusion 2.0 with OpenCLIP ViT-H/14. Each client uses only locally visible labels for class-aligned prompts, resizes/crops candidates to the target tensor layout, and applies an in-distribution filter estimated from a small held-out slice of its training partition. The public checkpoint is used without dataset-specific fine-tuning; no separate medical generator or test image is used. All artifacts remain local. Optional adaptation on a sanctioned in-domain corpus is supported but unused here.\n\n**4. No privacy–utility trade-off analysis**\n\nThe manuscript reports the medical RR/PSNR/SSIM endpoints without defense and at $M=2048$. We add the Eloul et al. baseline, the masking-batch sweep, and final task accuracy below. ACC and RR are percentages.\n\n**Table 2. Privacy–utility trade-off against Robbing-the-Fed**\n\n| Setting | Chest ACC↑ | Chest RR↓ | Chest PSNR↓ | Chest SSIM↓ | OrganA ACC↑ | OrganA RR↓ | OrganA PSNR↓ | OrganA SSIM↓ | Path ACC↑ | Path RR↓ | Path PSNR↓ | Path SSIM↓ |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| None | 55.8 | 89.06 | 62.40 | 0.94 | 58.6 | 82.81 | 50.60 | 0.89 | 57.3 | 78.13 | 45.20 | 0.86 |\n| Eloul et al. | 55.7 | 85.94 | 58.90 | 0.92 | 58.5 | 79.69 | 47.90 | 0.87 | 57.2 | 75.00 | 42.60 | 0.83 |\n| Aegis-512 | 56.0 | 49.95 | 34.59 | 0.69 | 58.8 | 47.82 | 31.19 | 0.69 | 57.5 | 44.34 | 27.45 | 0.61 |\n| Aegis-1024 | 55.9 | 27.03 | 25.06 | 0.55 | 59.0 | 27.31 | 24.54 | 0.58 | 57.6 | 24.53 | 21.36 | 0.47 |\n| Aegis-1536 | 55.7 | 16.24 | 21.08 | 0.49 | 58.9 | 17.66 | 21.76 | 0.53 | 57.4 | 15.21 | 18.82 | 0.41 |\n| Aegis-2048 | 55.5 | 9.50 | 18.70 | 0.46 | 58.8 | 11.63 | 20.10 | 0.51 | 57.2 | 9.38 | 17.30 | 0.38 |\n\nEloul et al. preserves utility but only modestly reduces RR. Consistent with Fig. 4, Aegis reconstruction metrics fall steeply through $M=1024$ and then taper, while accuracy remains within a fraction of a point of no defense.\n\n**5. Gradient weighting and minor clarifications**\n\nNo mixing coefficient is tuned. In each epoch, the client completes the real-data mini-batches and then applies one defense update with the same optimizer and learning rate; defense micro-batches are accumulated into that update. The $\\lambda=M/(B+M)$ in the effective-gradient view only normalizes this unweighted sequence by sample count; it is not an implementation multiplier. Optional scaling is unused. We will correct the SSIM range to $[0,1]$, define RR at first use, and add accuracy-versus-wall-clock curves."+ },+ "createdAt": "2026-07-30T00:45:37.641Z",+ "modifiedAt": "2026-11-19T16:43:53.529Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=LxAv8xH0vW",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/mmmjlszk1w.json added
+++ b/reviews/openreview/vulqnqztwo/notes/mmmjlszk1w.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "MmMjLszk1w",+ "replyTo": "yDoqCek8Wx",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer veVQ",+ "content": {+ "comment": "Thanks for the clarification and addressing my concerns."+ },+ "createdAt": "2026-07-31T10:57:59.531Z",+ "modifiedAt": "2026-11-19T16:43:49.668Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=MmMjLszk1w",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/nbgrjvg498.json added
+++ b/reviews/openreview/vulqnqztwo/notes/nbgrjvg498.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "NbGRJVG498",+ "replyTo": "MmMjLszk1w",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for your time and constructive feedback."+ },+ "createdAt": "2026-07-31T17:11:04.468Z",+ "modifiedAt": "2026-11-19T16:43:49.442Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=NbGRJVG498",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/pixniycvw4.json added
+++ b/reviews/openreview/vulqnqztwo/notes/pixniycvw4.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "piXNiYCvW4",+ "replyTo": "ALHc1hIbql",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for your constructive feedback. If accepted, we will incorporate all additional results and clarifications into the camera-ready version."+ },+ "createdAt": "2026-07-30T17:02:00.231Z",+ "modifiedAt": "2026-11-19T16:43:50.908Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=piXNiYCvW4",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/r72yqkesfx.json added
+++ b/reviews/openreview/vulqnqztwo/notes/r72yqkesfx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "R72yQKeSfX",+ "replyTo": "VI1HBKlUof",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer MUKd",+ "content": {+ "comment": "Thank you for the explanation. Your clarifications have addressed my concerns, and I am willing to increase my score to 4."+ },+ "createdAt": "2026-08-01T16:22:47.573Z",+ "modifiedAt": "2026-11-19T16:43:49.454Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=R72yQKeSfX",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/uxiawzjhsu.json added
+++ b/reviews/openreview/vulqnqztwo/notes/uxiawzjhsu.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "UxiaWzJHsU",+ "replyTo": "kp9NV3STyQ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you for your feedback. We will further polish the paper and clearly distinguish our threat model from that of [23] in the final version."+ },+ "createdAt": "2026-07-30T17:03:37.229Z",+ "modifiedAt": "2026-11-19T16:43:52.800Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=UxiaWzJHsU",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/vi1hbkluof.json added
+++ b/reviews/openreview/vulqnqztwo/notes/vi1hbkluof.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "VI1HBKlUof",+ "replyTo": "sa0re4O9QY",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the constructive comments.\n\nWe clarify the assumptions below.\n\n**1. Mismatch between the threat model and defense condition**\n\nWe clarify that $k$ is not hidden: it is simply the number of neurons in the first crafted fully connected layer of the broadcast global model. The client receives the complete architecture before local training and reads $k$ directly from that broadcast. If the server changes the layer width, the changed $k$ is immediately visible. Thus, the client does not need to infer or upper-bound an unknown server-side quantity. We will state this and the scope of the evaluated FC-based linear-leakage attacks explicitly.\n\n**2. Limited medical realism**\n\nWe agree that MedMNIST is a processed benchmark rather than raw clinical data. We use its chest X-ray, abdominal CT, and histopathology tasks to evaluate defense effectiveness and utility impact in a common, controlled medical-FL classification setting. This does not replace validation on full-resolution clinical data. However, Aegis acts on gradients of data already prepared for FL training and is not restricted to MedMNIST resolution. Full-resolution DICOM studies, 3D volumes, and whole-slide pathology are important large-scale extensions.\n\n**3. Generator assumption and memorization risk**\n\nThe reported implementation uses public Stable Diffusion 2.0 with OpenCLIP ViT-H/14, without dataset-specific fine-tuning, a separate medical generator, or test images. Each client uses only locally visible labels to form prompts and a small held-out slice of its training partition for the in-distribution check. An out-of-distribution candidate is discarded and never enters the defense cache or masking update. The generator, held-out slice, and accepted cache remain local; the server receives only the protected model update. Thus, no generator or synthetic/private sample creates a separate server-visible release channel under our threat model. We will clarify this filtering step and trust boundary.\n\n**4. Practicality for resource-constrained medical FL clients**\n\nOur clients are hospitals, laboratories, or healthcare organizations in cross-silo FL, rather than phones or IoT devices. We therefore assume each institutional client has sufficient compute and memory for local generation and training. For one client, the one-time generation phase runs on a single 10-GB RTX 3080. Generating 2,048 accepted images takes approximately 2.8 hours; they are then reused across all FL rounds. The MedMNIST-size cache occupies only 1.6–4.8 MB as uint8 images (6.4–19.3 MB as float32 tensors). A client need not train a generator from scratch, and optional adaptation is offline. During FL, the generator is unloaded and only one masking pass is added per local epoch. Gradient accumulation uses small physical micro-batches, keeping peak memory within the local training GPU."+ },+ "createdAt": "2026-07-30T00:55:15.650Z",+ "modifiedAt": "2026-11-19T16:43:50.923Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=VI1HBKlUof",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/whog60wzmp.json added
+++ b/reviews/openreview/vulqnqztwo/notes/whog60wzmp.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "WHOg60wZMP",+ "replyTo": "6RwB2h8H8S",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank the Area Chair and all reviewers for the constructive comments and the time devoted to evaluating our work. After carefully considering the feedback, we have provided detailed clarifications and conducted additional experiments that address the main concerns:\n\n1. **Technical details.** We clarify how the defense batch is selected relative to the attack-bin width $k$, that $k$ is directly visible from the first crafted fully connected layer in the broadcast model, and that our implementation applies an unweighted defense-gradient update after the real-data mini-batches in each local epoch.\n\n2. **Missing baseline.** We add the suggested prior gradient-mixing method as a direct baseline under the same federated-learning and Robbing-the-Fed protocol, and clarify its relationship to and distinction from Aegis.\n\n3. **Generator configuration.** We specify the exact reported pipeline—public Stable Diffusion 2.0 with OpenCLIP ViT-H/14, locally visible labels, and client-side in-distribution filtering—and clarify that no test images or dataset-specific generator fine-tuning are used. We also add an ablation using alternative diffusion-, VAE-, and GAN-based generators.\n\n4. **Medical evidence and generalization.** We add final task accuracy and privacy–utility results (RR, PSNR, and SSIM) on ChestMNIST, OrganAMNIST, and PathMNIST, together with sensitivity studies over masking-batch size, non-IID partitions, and CNN/Transformer backbones. We also clarify that MedMNIST provides a controlled evaluation across three medical modalities, while validation on full-resolution DICOM studies, 3D volumes, and whole-slide pathology remains an important extension rather than a claim made by the current paper.\n\nWe believe these clarifications and additional results substantially address the concerns raised in the reviews and strengthen the technical and empirical case for the paper. We would be very happy to discuss any remaining questions with the Area Chair and reviewers. Thank you again for your careful assessment and valuable feedback."+ },+ "createdAt": "2026-07-30T01:04:35.668Z",+ "modifiedAt": "2026-11-19T16:43:50.915Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=WHOg60wZMP",+ "license": "CC-BY-4.0"+}
reviews/openreview/vulqnqztwo/notes/ydoqcek8wx.json added
+++ b/reviews/openreview/vulqnqztwo/notes/ydoqcek8wx.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "yDoqCek8Wx",+ "replyTo": "Fn8XfrIPkm",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the reviewer for the constructive comments.\n\n**Generator configuration.** The reported implementation uses one pipeline across MNIST, CIFAR-10, and all three MedMNIST modalities: the public Stable Diffusion 2.0 latent-diffusion model with OpenCLIP ViT-H/14. Each client constructs class-aligned prompts only from locally visible labels, resizes/crops candidates to the target tensor layout, and applies a client-side in-distribution filter estimated from a small held-out slice of its training partition. The public checkpoint is used without dataset-specific fine-tuning; no separate medical generator or test image is used. The generator, held-out training slice, and accepted defense cache remain local.\n\n**Generator ablation.** We additionally evaluate three architecturally diverse alternatives: **SDXL 1.0** (text-conditioned latent diffusion), **VQ-VAE-2** (hierarchical discrete VAE), and **StyleGAN2-ADA** (conditional GAN). Each alternative is conditioned or, where needed, adapted using a sanctioned client-side training split; no test image is used. We apply the same locally visible labels, preprocessing, acceptance filter, and $M=2048$ cache. All variants use the same 100-client non-IID FedAvg and Robbing-the-Fed configuration ($B=64$, $E=3$, $k=1024$). Generation is offline and cached; online, every variant adds the same masking-gradient pass per local epoch. Thus, the reported online cost is independent of generator family.\n\n**Table 1. Generator ablation under the same Aegis/attack configuration. ACC and RR are percentages.**\n\n| Generator | Chest ACC↑ | Chest RR↓ | Chest PSNR↓ | Chest SSIM↓ | OrganA ACC↑ | OrganA RR↓ | OrganA PSNR↓ | OrganA SSIM↓ | Path ACC↑ | Path RR↓ | Path PSNR↓ | Path SSIM↓ |\n|---|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|---:|\n| No defense | 55.8 | 89.06 | 62.40 | 0.94 | 58.6 | 82.81 | 50.60 | 0.89 | 57.3 | 78.13 | 45.20 | 0.86 |\n| Stable Diffusion 2.0 | 55.5 | 9.50 | 18.70 | 0.46 | 58.8 | 11.63 | 20.10 | 0.51 | 57.2 | 9.38 | 17.30 | 0.38 |\n| SDXL 1.0 | 55.6 | 9.06 | 18.30 | 0.44 | 58.7 | 10.94 | 19.60 | 0.49 | 57.3 | 8.75 | 16.90 | 0.36 |\n| VQ-VAE-2 | 55.4 | 10.63 | 19.20 | 0.48 | 58.6 | 12.50 | 20.70 | 0.53 | 57.1 | 10.31 | 17.90 | 0.41 |\n| StyleGAN2-ADA | 55.3 | 11.25 | 19.60 | 0.49 | 58.5 | 12.81 | 21.10 | 0.54 | 57.0 | 10.63 | 18.20 | 0.42 |\n\nAcross generators, final accuracy changes by at most 0.4 points and RR by at most 2.2 points, while all reduce RR from 78.13–89.06% to 8.75–12.81%. This stability is expected: the accepted cache size leaves $B+M>k$ unchanged, while the common client-side filter limits distributional mismatch. Generator choice therefore causes only small variation after the same acceptance protocol. We will add this ablation and the exact configurations to the revision."+ },+ "createdAt": "2026-07-30T00:52:29.803Z",+ "modifiedAt": "2026-11-19T16:43:50.901Z",+ "url": "https://openreview.net/forum?id=vUlQnQztWO¬eId=yDoqCek8Wx",+ "license": "CC-BY-4.0"+}