potentialpaper

Certified Single-Level Reformulation for Tri-Level Cyber-Physical Grid Security

Update NeurIPS 2026 submission UZCoLnaUiy: 8 notes

@openreview[bot] · 2026-11-24 15:51 UTC · b91949dac49c ·

Evidence

reviews/openreview/uzcolnauiy/notes/1uudnihjpp.json added

+++ b/reviews/openreview/uzcolnauiy/notes/1uudnihjpp.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "1UudNIhjpp",
+ "replyTo": "Yyvrbwn6kh",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We sincerely thank the reviewer for the positive follow-up and are encouraged that the rebuttal has addressed the major concerns regarding notation, certification, objective formulation, and relaxation gaps.\n\n---\n\n**Regarding W3 (Big-$M$):** Yes. Under the DC-OPF assumptions, the required bounds are already established in **Lemma R1** from the physics of the load-shedding OPF, while **Algorithm 1** provides a constructive procedure for computing every Big-$M$ constant. The final a-posteriori verification is a **sufficient certificate of exactness of the Big-$M$ reformulation**: if none of the Big-$M$ envelopes is active at the optimum, then the linearized MILP coincides with the original complementarity-constrained formulation for that instance, i.e., no artificial constraint affects the returned optimum. This verification is independent of how conservative the analytic bounds are. We will explicitly clarify this point in the revised manuscript.\n\n---\n\n\n**Regarding W5 (larger-scale systems):** We thank the reviewer for this valuable suggestion. Following the reviewer's recommendation, we have run the tri-level DC-OPF on the **IEEE 118-bus** system with settings similar to those in Table 4 of the paper (and the table in response to **Q3** of the Reviewer **3m6F**). The proposed SL-MILP continues to produce conservative certificates, with all reported instances satisfying $\\Delta_C \\ge 0$ and $\\Delta_0 \\ge 0$ (and close to zero).\n\n| $D$ | $S_{SL}$ | $S_{true}(d_{SL}^* )$ | $\\Delta_C$ | $S^*$ | $\\Delta_0$ |\n|:-:|--:|--:|--:|--:|--:|\n|0|110.0|110.0|0.0|110.0|0.0|\n|1|105.2|104.8|0.4|104.0|0.8|\n|2|51.6|49.3|2.3|48.1|1.2|\n|3|45.0|43.6|1.4|42.1|1.5|\n|4|44.8|43.1|1.7|42.0|1.1|\n|5|43.8|42.3|1.5|41.0|1.3|\n\nWe agree that even larger, industry-oriented benchmark suites such as **ARPA-E** and **PFΔ** would provide an important next step. Unlike the classical IEEE test cases, these datasets incorporate significantly richer operational complexity (e.g., security-constrained AC-OPF, multiple operating scenarios and contingencies, and additional discrete controls), resulting in substantially larger mixed-integer optimization problems. Extending our compact single-level reformulation to these realistic benchmark suites is therefore a natural and important direction for future work, and we will explicitly acknowledge this as one of the limitations of the current work in the revised manuscript."
+ },
+ "createdAt": "2026-08-04T02:04:42.406Z",
+ "modifiedAt": "2026-11-19T17:01:25.857Z",
+ "url": "https://openreview.net/forum?id=UZCoLnaUiy&noteId=1UudNIhjpp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/uzcolnauiy/notes/obmtr3fg6s.json added

+++ b/reviews/openreview/uzcolnauiy/notes/obmtr3fg6s.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "OBmTR3FG6S",
+ "replyTo": "ZQFzttHpIi",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to the Meta Review",
+ "comment": "We thank the Area Chair for the constructive meta-review. We address the major concerns below and clarify the scope of our theoretical guarantees.\n\n- **The certification guarantee is clarified precisely.** \n The only approximation in the DC pipeline is the attacker relaxation, which can only enlarge the attack set and therefore yields a **conservative** certificate. The selected defense is then certified exactly via the merged defender-operator problem.\n(See our response to Reviewer **L6eE: W2, W6, Q** and Reviewer **Qe5o: Q(ii), Q(v)**)\n\n- **All Big-M constants are derived analytically.** \n We derive closed-form bounds from physical limits and dual feasibility, prove boundedness (Lemma R1), provide an explicit construction algorithm, and add an a-posteriori envelope-activity check. No heuristic tuning is required.\n (See our response to Reviewer **L6eE: W3**, Reviewer **3m6F: W2, Q2**, and **Reviewer Qe5o: Q(iv)**.)\n\n- **The certificate gap is now quantified.** \n We report the exact merged-problem value $S_{\\mathrm true}(d_{SL}^* )$, the certificate gap $\\Delta_C$, and the gap to the original tri-level optimum $\\Delta_0$ for every benchmark, directly validating Theorem 5.4.\n (See our response to **Reviewer L6eE: W6, Q** and Reviewer **3m6F: Q3**)\n\n- **The SOCP-versus-AC gap is evaluated explicitly.** \n We compare the SOCP relaxation with the exact AC-OPF on the IEEE 9-bus system. Both attain the same optimal objective with zero load shedding. Active-power dispatch, voltage magnitudes, and phase angles are nearly identical.\n (See our response to Reviewer **3m6F: W3**)\n\n- **The experimental scope is clarified.** \n The DC formulation is evaluated on **seven IEEE systems (5, 9, 14, 22, 30, 57, and 69 buses)**. For the AC formulation, we also include AC results for the IEEE 14-, 30-, and 57-bus systems.\n (See our response to Reviewer **L6eE: W5** and Reviewer **Qe5o: Q(i).(c)**)\n\n- **Notation has been unified.** \n We will correct all typographical inconsistencies, unify the notation, and add complete variable lists and a glossary. These changes are editorial only; the derivations, implementation, and results are unchanged. (See our response to **Reviewer L6eE: W1** and **Reviewer 3m6F: W1**)\n\nOverall, we believe the rebuttal resolves the technical concerns raised in the reviews and the meta-review. The certification guarantee is now stated precisely, the Big-M construction is fully justified, the conservative gaps are quantified, and the AC relaxation is evaluated empirically."
+ },
+ "createdAt": "2026-08-01T05:09:00.027Z",
+ "modifiedAt": "2026-11-19T17:01:26.058Z",
+ "url": "https://openreview.net/forum?id=UZCoLnaUiy&noteId=OBmTR3FG6S",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/uzcolnauiy/notes/qm0gokvhjb.json added

+++ b/reviews/openreview/uzcolnauiy/notes/qm0gokvhjb.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "qM0GoKvHjb",
+ "replyTo": "UAE59uq249",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "We are glad to know that the concerns regarding the Big-$M$ construction, certificate-gap reporting, DC certification, experimental scope, and notation have been resolved.\n\nWe agree that our current theory does not establish the certificate for the original nonconvex AC-OPF under all operating conditions. And we confirm that we do NOT solve the nonlinear AC-OPF globally, hence we **do not claim a theoretical certificate** for the nonconvex AC model.\n\nThe proven upper-bound and certification guarantees apply to the **SOCP-relaxed AC operator model**, where every dualization step is exact by strong duality. We will revise the manuscript to state this explicitly after *Theorem 5.4* and in the abstract.\n\nFinally we regret any inconvenience caused by the cross-references. Given the strict rebuttal character limit, we used them solely to avoid repetition."
+ },
+ "createdAt": "2026-08-03T04:18:38.199Z",
+ "modifiedAt": "2026-11-19T17:01:26.085Z",
+ "url": "https://openreview.net/forum?id=UZCoLnaUiy&noteId=qM0GoKvHjb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/uzcolnauiy/notes/uae59uq249.json added

+++ b/reviews/openreview/uzcolnauiy/notes/uae59uq249.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "UAE59uq249",
+ "replyTo": "l4grrrwFs5",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer Qe5o",
+ "content": {
+ "comment": "Thank you for the clarifications. The concerns regarding the Big-(M) construction, certificate-gap reporting, DC certification, experimental scope, and notation have been largely addressed.\n\nOne major issue remains. The comparison on the IEEE 9-bus system does not establish that the SOCP-based certificate is valid for the original nonconvex AC model, especially under stressed post-attack conditions. Please clarify whether “exact AC-OPF” is globally solved and, unless stronger evidence is provided, state explicitly that the AC certificate applies only to the SOCP-relaxed model.\n\nFinally, future responses should reproduce all substantive answers directly. Reviewers are not obligated to search across separate response threads referenced only by labels."
+ },
+ "createdAt": "2026-08-03T01:14:02.666Z",
+ "modifiedAt": "2026-11-19T17:01:26.089Z",
+ "url": "https://openreview.net/forum?id=UZCoLnaUiy&noteId=UAE59uq249",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/uzcolnauiy/notes/ui57vzeokb.json added

+++ b/reviews/openreview/uzcolnauiy/notes/ui57vzeokb.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "ui57VZeoKB",
+ "replyTo": "vJBFfrRjGL",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you for your positive consideration of our revisions."
+ },
+ "createdAt": "2026-08-04T11:48:01.802Z",
+ "modifiedAt": "2026-11-19T17:01:25.839Z",
+ "url": "https://openreview.net/forum?id=UZCoLnaUiy&noteId=ui57VZeoKB",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/uzcolnauiy/notes/vjbffrrjgl.json added

+++ b/reviews/openreview/uzcolnauiy/notes/vjbffrrjgl.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "vJBFfrRjGL",
+ "replyTo": "1UudNIhjpp",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer L6eE",
+ "content": {
+ "comment": "Thank the authors for the clarifications. I will take them into account when preparing my final comments and adjust my score accordingly."
+ },
+ "createdAt": "2026-08-04T09:42:35.439Z",
+ "modifiedAt": "2026-11-19T17:01:25.849Z",
+ "url": "https://openreview.net/forum?id=UZCoLnaUiy&noteId=vJBFfrRjGL",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/uzcolnauiy/notes/yyvrbwn6kh.json added

+++ b/reviews/openreview/uzcolnauiy/notes/yyvrbwn6kh.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "Yyvrbwn6kh",
+ "replyTo": "n8j25NGe0K",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer L6eE",
+ "content": {
+ "comment": "Thank the authors for the detailed rebuttal. The rebuttal has clarified several of previous concerns, including the notations in W1, certificate in W2, clarity of load shedding and generation cost in W4, and gap in W6. I'm considering raising the score but would like to follow up on the Big-M in W3 and test cases in W5.\n\nIs a proof under the exact DC-OPF assumptions needed or already provided, as the line-flow dual variables satisfying $\\phi_{ij}^{\\pm}\\leq w$ looks intuitive. Does the check that no (M)-bound is active at the returned solution establish global exactness? Authors can choose to clarify or adjust the claim.\n\nThe additional 14-, 30-, and 57-bus results improve the evaluation, but these are still considered as small-scale test systems. Usually, some representative larger benchmarks, such as IEEE 118/300 or a PGLib/ACTIVSg cases would be necessary, in particular for the DC case. For example, the ARPA-E Grid Optimization Competition provides test systems with network sizes ranging from 500 to 30,000 buses. A recent benchmark paper PFΔ: A Benchmark Dataset for Power Flow under Load, Generation, and Topology Variations in NeurIPS 2025 considered IEEE-14, IEEE-30, IEEE-57, IEEE118, GOC-500, and GOC-2000. Given the limited time, authors can consider this as a limitation."
+ },
+ "createdAt": "2026-08-03T16:15:22.624Z",
+ "modifiedAt": "2026-11-19T17:01:26.475Z",
+ "url": "https://openreview.net/forum?id=UZCoLnaUiy&noteId=Yyvrbwn6kh",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/uzcolnauiy/notes/zqfztthpii.json modified

+++ b/reviews/openreview/uzcolnauiy/notes/zqfztthpii.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair r4sy",
"content": {
- "metareview": "This paper develops certified single-level reformulations of a tri-level grid-defense problem for DC and SOCP-relaxed AC models. The rebuttal largely addresses the concerns about notation, Big-M bounds, certificate gaps, and experimental scope. It also appropriately clarifies that the AC certificate applies only to the SOCP model, not the nonconvex AC-OPF. Although AC validation and large-scale evaluation remain limited, these are limitations rather than fundamental flaws. I recommend acceptance."
+ "metareview": "This paper develops certified single-level reformulations of a tri-level grid-defense problem for DC and SOCP-relaxed AC models. The rebuttal largely addresses the concerns about notation, Big-M bounds, certificate gaps, and experimental scope. It also appropriately clarifies that the AC certificate applies only to the SOCP model, not the nonconvex AC-OPF. Although AC validation and large-scale evaluation remain limited, these are limitations rather than fundamental flaws. I recommend acceptance.",
+ "final_justification": "The rebuttal resolves the main technical concerns and appropriately narrows the AC guarantee. The remaining limitations do not undermine the core DC and SOCP contributions."
},
"createdAt": "2026-07-20T13:23:25.075Z",
- "modifiedAt": "2026-11-18T15:24:09.503Z",
+ "modifiedAt": "2026-11-19T05:02:36.941Z",
"url": "https://openreview.net/forum?id=UZCoLnaUiy&noteId=ZQFzttHpIi",
"license": "CC-BY-4.0"
}