+ "title": "Follow-up: inversion on 50k images and cell-shape MRA",
+ "comment": "We are adding a short follow up to point out further experiemnts demonstrating numerical accuracy of the inversion, as well as MRA on microscopy cell shapes demonstrating its practical application. Reviewer 2hsc asked about the numerical accuracy of our inversion. To answer this, we took the full test sets of MNIST, Fashion-MNIST, CIFAR10, rotated and translated MNIST, and rotated and translated Fashion-MNIST ($10{,}000$ images each), plus all $650$ osteosarcoma cell images, for $50{,}650$ images in total. For each image we computed its SDB and used our inversion to reconstruct the image. We report the median relative $\\ell_2$ reconstruction error after rotation registration, at resolutions $L\\in\\{28,56,112,256,500\\}$. As a baseline, we also map each image to its disk harmonic coefficients and back, without forming the bispectrum. Full tables are in our Official Comment to Reviewer 2hsc. At $L{=}500$, every dataset has median SDB error at most $0.08$, and much of that error is already present in the disk-harmonic round trip.\n\nTo show a practical use of SDB beyond a compact descriptor for classification, we also run multi-reference alignment on osteosarcoma cell shapes. Microscopy often yields many randomly rotated noisy copies of one morphology, and the goal is to recover a clean template without knowing the rotations. Because SDB is rotation-invariant, we average SDB coefficients across observations and invert the average to get an image-space template. The 1D translation-invariant bispectrum has been used for this task in several scientific settings, but MRA for rotated 2D images was previously impossible because the recovery step requires analytic inversion. Without inversion, an average in bispectrum space does not yield a usable cell image. At $L{=}500$, centered control templates have relative MRA error about $0.05$ to $0.07$ under mild noise. Details are again in the comment to Reviewer 2hsc."
+ },
+ "createdAt": "2026-08-03T01:47:36.431Z",
+ "modifiedAt": "2026-11-19T16:58:23.722Z",
+ "url": "https://openreview.net/forum?id=ZBFrV7kiwX&noteId=3ocwwbkB9b",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/zbfrv7kiwx/notes/4vv4q3qdzi.json added

+++ b/reviews/openreview/zbfrv7kiwx/notes/4vv4q3qdzi.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "4VV4q3qdzi",
+ "replyTo": "kYnB3pVQjC",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Gentle follow-up on SE(2) / Harmonic baselines and MRA scope",
+ "comment": "Dear Reviewer oCu4,\n\nWith the discussion period closing Monday (AoE), we wanted to gently follow up on our rebuttal. It responds to your requests for stronger equivariant baselines and for clarifying the scope of the MRA section, including new SE(2) and Harmonic Network comparisons on rotated and translated MNIST and a rewritten MRA discussion.\n\nWe have sincerely appreciated your feedback, and we believe addressing it has strengthened the paper. Thank you.\n\nIf you confirm that our rebuttal resolves your concerns, we would be grateful for a brief acknowledgment and, should you judge it warranted, an updated score. If any questions remain, we would be very happy to clarify them before the deadline.\n\nAll the best and thanks again,\nThe Authors"
+ },
+ "createdAt": "2026-08-01T23:46:34.956Z",
+ "modifiedAt": "2026-11-19T16:58:23.820Z",
+ "url": "https://openreview.net/forum?id=ZBFrV7kiwX&noteId=4VV4q3qdzi",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/zbfrv7kiwx/notes/axbh5jqnjc.json added

+++ b/reviews/openreview/zbfrv7kiwx/notes/axbh5jqnjc.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "AxbH5JqnJC",
+ "replyTo": "V35XaTpjZm",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Reconstruction stats across 6 datasets, total of 50650 images (inversion accuracy). New experiment: MRA on cell shape images (practical application)",
+ "comment": "We thank the reviewer for the updated assessment. We address the remaining reservations on reconstruction accuracy and broader applicability of SDB below. Side-by-side reconstructions will appear in the camera-ready. We are happy to provide anonymized links to these figures. Per NeurIPS guidelines we should not post links unless you explicitly request them. Please ask if you would like them.\n\n**1. Practical numerical accuracy.**\nOur reconstruction is only as exact as our bispectrum map. Theorem 3 bounds the error between the exact bispectrum and the bandlimited implemented bispectrum by a term that shrinks as the number of pixels grows. We demonstrate this on full evaluation sets across six datasets at $L\\in\\{28,56,112,256,500\\}$, using all $N{=}650$ osteosarcoma cell silhouettes and the full $10{,}000$-image test sets for MNIST, Fashion-MNIST, rotated and translated MNIST, rotated and translated Fashion-MNIST, and CIFAR10. Errors are median relative $\\ell_2$ after rotation registration. Each entry is SDB inversion error (with DHC round-trip error in parentheses).\n\n| dataset | $L{=}28$ | $L{=}56$ | $L{=}112$ | $L{=}256$ | $L{=}500$ |\n|---|---|---|---|---|---|\n| osteosarcoma cells | 0.259 (0.051) | 0.153 (0.073) | 0.076 (0.030) | 0.086 (0.056) | 0.079 (0.038) |\n| CIFAR10 | 0.281 (0.133) | 0.207 (0.160) | 0.144 (0.121) | 0.077 (0.061) | 0.055 (0.044) |\n| Fashion-MNIST | 0.342 (0.123) | 0.245 (0.178) | 0.153 (0.115) | 0.059 (0.019) | 0.038 (0.009) |\n| rotated and translated Fashion-MNIST | 0.360 (0.138) | 0.305 (0.242) | 0.206 (0.171) | 0.088 (0.044) | 0.053 (0.015) |\n| MNIST | 0.446 (0.134) | 0.250 (0.158) | 0.136 (0.085) | 0.064 (0.017) | 0.043 (0.007) |\n| rotated and translated MNIST | 0.481 (0.163) | 0.315 (0.203) | 0.163 (0.102) | 0.069 (0.022) | 0.046 (0.009) |\n\nAt $L{=}500$, a common microscopy image size, every dataset has median SDB error at most $0.08$. The highest is osteosarcoma cells at $0.079$ and the lowest is Fashion-MNIST at $0.038$. Osteosarcoma cells already reach $0.076$ at $L{=}112$. At this resolution the reconstructed cell morphology is visually not distinguishable from the original. Most residual numerical error is an intensity fade, for example white turning to grey, while structure is preserved. We can corroborate this with an anonymized link to the side-by-side figures if you request it, per NeurIPS guidelines on not sharing links except upon request.\n\nThe key point is that SDB error stays close to DHC round-trip error at large $L$. Much of the reconstruction error is already present when we project onto disk harmonics and reconstruct the image, without ever forming the SDB. Selective inversion does not introduce a large new failure mode on top of bandlimiting.\n\n**2. Broader applicability of SDB.** On real osteosarcoma cell imaging, two tasks show that SDB is usable in the scientific domain.\n\n**(A) Cell treatment classification.** We classify real mouse osteosarcoma cell silhouettes by treatment on $N{=}650$ cells, using a $70/30$ split. This is a typical scientific dataset size. Here, there is no canonical upright orientation, so rotation invariance is scientifically meaningful. At $L{=}56$, SDB reaches $0.727{\\pm}0.093$ classification accuracy, whereas trained G-CNN, select_gbisp, and tc baselines and frozen DINOv3, EVA, and OpenCLIP encoders near $0.68$ to $0.69$. At $L{=}112$, SDB reaches $0.768{\\pm}0.189$, again the strongest among those methods. Full tables appear in our response to Reviewer jqS8.\n\n**(B) Cell MRA.** A second scientific use is multi-reference alignment of cell shapes. Microscopy often yields many randomly rotated noisy copies of one morphology, and the goal is to recover a clean template without knowing the rotations. Because SDB is rotation-invariant, one can average SDB coefficients across observations to suppress noise and then invert the average to obtain an image-space template. The 1D translation invariant bispectrum has been used for this task, but it was not possible for rotated noisy image because the recovery step requires analytic inversion. Without inversion, an average in bispectrum space would not produce a usable cell image.\n\nCentered relative MRA errors on osteosarcoma templates at $L{=}500$ are reported below. This is a new experiment relative to the Tuesday rebuttal.\n\n| treatment | $\\sigma{=}0$ | $\\sigma{=}0.05$ | $\\sigma{=}0.1$ |\n|---|---|---|---|\n| control | 0.064 | 0.051 | 0.068 |\n| jasp | 0.084 | 0.067 | 0.110 |\n| cytd | 0.152 | 0.252 | 0.207 |\n\nSingle-image inversion of control templates stays near $0.055$ to $0.059$ across the same noise levels.\n\nCell classification and cell MRA are concrete scientific use-cases under the stated assumptions.\n\nIf these additions resolve your reservations we would be grateful if you would consider raising your score further. If anything else remains a concern please let us know so we can address it."
+ },
+ "createdAt": "2026-07-31T14:56:45.102Z",
+ "modifiedAt": "2026-11-19T16:58:23.998Z",
+ "url": "https://openreview.net/forum?id=ZBFrV7kiwX&noteId=AxbH5JqnJC",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/zbfrv7kiwx/notes/dencuvlcdp.json added

+++ b/reviews/openreview/zbfrv7kiwx/notes/dencuvlcdp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "DENcuvlCdP",
+ "replyTo": "V35XaTpjZm",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer 2hsc",
+ "content": {
+ "title": "I have updated the assessment.",
+ "comment": "Thank you for the detailed rebuttal and the additional reconstruction and practical-scope results. I have updated my assessment to reflect the Theory contribution type and have given less weight to empirical competitiveness against pretrained features.\n\nThe rebuttal clarified the main sources of reconstruction error and provided useful additional comparisons between SDB and the underlying disk-harmonic reconstruction. I also appreciate the clarification of the intended application scope and the additional osteosarcoma-cell experiment.\n\nAccordingly, I revised the significance score to 2, the overall recommendation to Borderline Reject, and the confidence to 3. My remaining reservations concern the practical numerical accuracy of inversion and the limited evidence for broader applicability, but these now carry less weight than in my initial assessment."
+ },
+ "createdAt": "2026-07-30T08:21:23.123Z",
+ "modifiedAt": "2026-11-19T16:58:23.970Z",
+ "url": "https://openreview.net/forum?id=ZBFrV7kiwX&noteId=DENcuvlCdP",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/zbfrv7kiwx/notes/ewy1x4pcri.json added

+++ b/reviews/openreview/zbfrv7kiwx/notes/ewy1x4pcri.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "eWY1X4pCRI",
+ "replyTo": "AfDpL7Wvf9",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Gentle follow-up on translation, inversion assumptions, and cell experiments",
+ "comment": "Dear Reviewer jqS8,\n\nAs the discussion period ends Monday (AoE), we wanted to gently follow up on our rebuttal. It addresses your concerns about translation and centering, the $a_{n,1}\\neq 0$ inversion assumption, and practical scientific scope, including admissible-translation separability experiments, classification on rotated and translated MNIST, and osteosarcoma cell treatment classification.\n\nWe have sincerely appreciated your careful reading, and we believe these additions have strengthened the paper. Thank you.\n\nIf you confirm that our rebuttal resolves your concerns, we would be grateful for a brief acknowledgment and, should you judge it warranted, an updated score. If any questions remain, we would be very happy to clarify them before the deadline.\n\nAll the best and thanks again,\nThe Authors"
+ },
+ "createdAt": "2026-08-01T23:48:15.201Z",
+ "modifiedAt": "2026-11-19T16:58:24.583Z",
+ "url": "https://openreview.net/forum?id=ZBFrV7kiwX&noteId=eWY1X4pCRI",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/zbfrv7kiwx/notes/jiueqjazxa.json modified

+++ b/reviews/openreview/zbfrv7kiwx/notes/jiueqjazxa.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair 6xwc",
"content": {
- "metareview": "This paper introduces the Selective Disk Bispectrum (SDB), a complex-valued, rotation-invariant image descriptor designed to reduce the computational and spatial complexity of the full disk bispectrum. The authors present strong theoretical contributions, including the first analytic inversion formula for the disk bispectrum, the identification of a minimal sufficient subset of coefficients for exact reconstruction, and a characterization of the descriptor's behavior. The method is evaluated on rotated, noisy MNIST and FashionMNIST datasets, as well as a multi-reference alignment (MRA) task.\n\nThe reviewers agree that the paper presents an elegant and mathematically sound theoretical framework. The derivation of an analytic inversion formula is a notable milestone, proving that the disk bispectrum is a complete rotation-invariant representation. Identifying a minimal subset of coefficients successfully reduces the computational bottleneck associated with the traditional disk bispectrum. Moreover, deriving the expectation and variance of the SDB under Gaussian noise provides a rigorous foundation for its application in noisy imaging environments.\n\nPrimary weaknesses:\nDespite the strong theoretical backing, all three reviewers raised significant concerns regarding the method's practical utility and the weakness of its empirical validation.\n\nThe most critical flaw identified by the reviewers is that the SDB is strictly invariant to global, perfectly centered rotations. It cannot handle translations, off-center rotations, or local feature rotations. Because real-world applications (like the paper's motivated use cases of cryo-EM and satellite imagery) rarely feature perfectly centered, single-object data, this omission severely limits the descriptor's practical applicability.\n\nThe experiments are restricted to low-resolution (up to 112x112), simplistic datasets (MNIST and FashionMNIST) and the paper lacks comparisons to contemporary, learning-based equivariant models (e.g., Steerable CNNs, Harmonic Networks). Finally, reviewer jqS8 questioned whether the mathematical assumptions required for inversion hold reliably in practical image data, and what the consequences are when inversion yields non-zero errors.\n\nFollowing the detailed rebuttal and the lack of answers from the reviewers, after additional reading I changed the decision to \"accept\"."
+ "metareview": "This paper introduces the Selective Disk Bispectrum (SDB), a complex-valued, rotation-invariant image descriptor designed to reduce the computational and spatial complexity of the full disk bispectrum. The authors present strong theoretical contributions, including the first analytic inversion formula for the disk bispectrum, the identification of a minimal sufficient subset of coefficients for exact reconstruction, and a characterization of the descriptor's behavior. The method is evaluated on rotated, noisy MNIST and FashionMNIST datasets, as well as a multi-reference alignment (MRA) task.\n\nThe reviewers agree that the paper presents an elegant and mathematically sound theoretical framework. The derivation of an analytic inversion formula is a notable milestone, proving that the disk bispectrum is a complete rotation-invariant representation. Identifying a minimal subset of coefficients successfully reduces the computational bottleneck associated with the traditional disk bispectrum. Moreover, deriving the expectation and variance of the SDB under Gaussian noise provides a rigorous foundation for its application in noisy imaging environments.\n\nPrimary weaknesses:\nDespite the strong theoretical backing, all three reviewers raised significant concerns regarding the method's practical utility and the weakness of its empirical validation.\n\nThe most critical flaw identified by the reviewers is that the SDB is strictly invariant to global, perfectly centered rotations. It cannot handle translations, off-center rotations, or local feature rotations. Because real-world applications (like the paper's motivated use cases of cryo-EM and satellite imagery) rarely feature perfectly centered, single-object data, this omission severely limits the descriptor's practical applicability.\n\nThe experiments are restricted to low-resolution (up to 112x112), simplistic datasets (MNIST and FashionMNIST) and the paper lacks comparisons to contemporary, learning-based equivariant models (e.g., Steerable CNNs, Harmonic Networks). Finally, reviewer jqS8 questioned whether the mathematical assumptions required for inversion hold reliably in practical image data, and what the consequences are when inversion yields non-zero errors.\n\nFollowing the detailed rebuttal and the lack of answers from the reviewers, after additional reading I changed the decision to \"accept\".",
+ "final_justification": "The authors send a very detailed rebuttal, and mentioned the focus on theory. After additional reading, I changed the final decision to \"accept\"."
},
"createdAt": "2026-07-24T10:11:09.431Z",
- "modifiedAt": "2026-11-18T15:24:12.826Z",
+ "modifiedAt": "2026-11-19T05:02:41.458Z",
"url": "https://openreview.net/forum?id=ZBFrV7kiwX&noteId=jiUEqjaZxA",
"license": "CC-BY-4.0"
}

reviews/openreview/zbfrv7kiwx/notes/zw0z8q0fcq.json added

+++ b/reviews/openreview/zbfrv7kiwx/notes/zw0z8q0fcq.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Zw0z8Q0FCQ",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Additional experiments on translated+rotated images, SE(2) and Harmonic baselines, cell data, and reconstruction, completed at the reviewers’ request",
+ "comment": "We thank the Area Chair and all reviewers for careful reading and constructive feedback. This global note summarizes the additional work completed during the rebuttal. Detailed numbers, tables, and proofs appear in the individual responses to Reviewers oCu4, jqS8, and 2hsc.\n\n**Theory-track framing (Area Chair and all reviewers).**\nThis paper was submitted to the Theory track. Its primary contributions are analytic inversion of the disk bispectrum, identification of a minimal complete subset of coefficients called the Selective Disk Bispectrum (SDB), complexity reduction with completeness guarantees, and noise expectation and variance results. The experiments illustrate these claims under the stated single-object and disk-support assumptions. We ask that significance be weighed under Theory-track criteria. At the same time, we treated the reviewers' experimental requests as genuine opportunities to strengthen the paper, and we carried them out.\n\n**Translation and centering (Reviewer jqS8).**\nWe define a translation as admissible when the object's support remains inside the computational disk after the translation. We measure SDB $\\ell_2$ separability under residual admissible translations on centered MNIST prototypes. For maximum translation radii from 1 to 8 pixels on a disk of diameter 56, the between-digit to within-digit separability ratios range from 22.6 down to 3.7 (Large = better. 1 is bad). Same-digit SDBs therefore remain clustered at moderate residual translations. We also clarify the theory. Under an in-disk support condition, SDB is translation-equivariant rather than translation-invariant. A short proof appears in our response to Reviewer jqS8.\n\n**Classification under rotation and translation (Reviewers jqS8 and oCu4).**\nWe compare SDB to G-CNN, select_gbisp, tc, SE(2) Networks, Harmonic Networks, and pretrained DINOv3, EVA, and OpenCLIP encoders on translated and rotated MNIST. We report results at resolutions $L\\in\\{28,56,112\\}$ and noise levels $\\sigma\\in\\{0,0.2,0.4\\}$. The full table is in our response to Reviewer jqS8, and a high-resolution summary is in our response to Reviewer oCu4. At high resolution with noise, SDB remains far above the G-CNN family and Harmonic Networks. SE(2) is strongest overall. Reviewer jqS8 requested the translated setting, and Reviewer oCu4 requested the SE(2) and Harmonic baselines.\n\n**Scientific cell-shape evaluation (Reviewer jqS8).**\nWe added a real scientific evaluation on osteosarcoma cell shapes. The dataset has $N=650$ cells with three treatment classes, namely control, jasp, and cytd. At $L=56$ and $L=112$, SDB with a small MLP is competitive with trained G-CNN, select_gbisp, and tc baselines, and with frozen pretrained encoders. Details appear in our response to Reviewer jqS8.\n\n**Reconstruction quality (Reviewer 2hsc).**\nOn 500 MNIST digits, we compute both disk-harmonic coefficient round-trip error and SDB inversion error across resolutions and noise levels. Most of the observed error comes from the bandlimited disk-harmonic projection. SDB medians are about $1.3$ to $1.6$ times the corresponding disk-harmonic medians, while coarse structure is preserved. We link these numbers to the visual quality of the paper's MRA reconstructions. In the camera-ready we will add histograms and side-by-side examples using the allowed extra content page.\n\n**Inversion assumption (Reviewer jqS8).**\nWe checked the inversion assumption $a_{1,1}\\neq 0$. On 500 MNIST images and all 650 cell silhouettes at $L=56$, the minimum absolute value of $a_{1,1}$ exceeds $10^{-2}$, and the fraction of near-zero coefficients is zero. For rare pathological cases we document a simple radial-index fallback in our response to Reviewer jqS8.\n\n**Practical scope and MRA (Reviewers oCu4 and 2hsc).**\nSDB targets single-object images with meaningful global rotation, such as cell microscopy. It is not intended for general natural scenes where upright orientation is already defined. We also affirm that the MRA section is a valued proof of concept in the spirit of prior translation-bispectrum MRA work.\n\n**Conclusion** These additions directly address the shared concerns on translation, stronger baselines, reconstruction quality, assumption validity, and scientific scope, while keeping the theoretical contributions central. We would be grateful if the Area Chair and reviewers would reconsider their assessments in light of this additional work."
+ },
+ "createdAt": "2026-07-29T01:23:24.812Z",
+ "modifiedAt": "2026-11-19T16:58:23.987Z",
+ "url": "https://openreview.net/forum?id=ZBFrV7kiwX&noteId=Zw0z8Q0FCQ",
+ "license": "CC-BY-4.0"
+}