CORTEG: Foundation Models Enable Cross-Modality Representation Transfer from Scalp to Intracranial Brain Recordings

Update NeurIPS 2026 submission ChfliH0uB0: 17 notes

@openreview[bot] · 2026-11-24 15:47 UTC · b8e03e92d6a0 ·

Evidence

reviews/openreview/chflih0ub0/notes/1sjflyv6ym.json added

+++ b/reviews/openreview/chflih0ub0/notes/1sjflyv6ym.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "1SJflYv6yM",
+ "replyTo": "TYsM4D9OwY",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer NvGg",
+ "content": {
+ "comment": "Thank you for the comprehensive rebuttal. The new comparisons with intracranial foundation models and the public BrainTreebank experiment address my main concerns. I will consider raising my score accordingly."
+ },
+ "createdAt": "2026-08-03T13:04:28.384Z",
+ "modifiedAt": "2026-11-19T17:12:36.787Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=1SJflYv6yM",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/1t6x3ojpbw.json added

+++ b/reviews/openreview/chflih0ub0/notes/1t6x3ojpbw.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "1T6X3OJpbw",
+ "replyTo": "XnOjX87XnB",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to reviewer w24A [part2]",
+ "comment": "### 3. BrainTreebank evaluation\n\nThe BrainTreebank experiment partly follows prior work, but the task and evaluation protocol are ours. For seven of the ten subjects we take the subject and session choices directly from PopT's held-out split (`trial_selections/test_trials.json`, also BrainBERT's), and we use PopT's `clean_laplacian` electrode list. The remaining three subjects (sub_5, sub_8, sub_9) are not in that split. They appear in those models' pretraining data, and each has only one session in the dataset. We use one session per subject throughout, which for the seven is exactly PopT's evaluation protocol. Published BrainTreebank numbers are not directly comparable because we chose a slightly different classification task: sentence onset vs. mid-sentence. The original word vs. non-word is an easier task, using a simple high gamma logistic regression, the word vs. non-word could achieve 0.843 (0.75–0.94), yet our task can only achieve 0.508 (0.48–0.52). We chose to run a more challenging task to better evaluate foudnation models. For the camera-ready version, we will report results for both tasks to enable direct comparison with previously published values.\n\n\n### 4. Scope and interpretation\n\nWe do not want to claim that intracranial foundation models cannot become competitive after task-specific retraining or target-corpus pretraining. Our result is narrower: their released representations do not transfer competitively (or at least easily) to our new datasets and tasks under the evaluated settings (a common standard one).\n\nTheir above-chance performance on BrainTreebank also serves as a useful positive control. It reduces concern that the weak regression results come from incorrect checkpoint loading or feature extraction.\n\nThe BrainTreebank experiment is also not intended as a leaderboard result. Its purpose is to test whether CORTEG's transfer benefit remains after changing the recording modality, task, and dataset. The matched pretrained-versus-random result supports that conclusion.\n\nWe appreciate this discussion, as it has helped us clarify our findings. A direct evaluation on Neuroprobe would be a valuable next step, but we believe it should be conducted carefully rather than added hastily during the final hours of the rebuttal period."
+ },
+ "createdAt": "2026-08-04T08:50:41.767Z",
+ "modifiedAt": "2026-11-19T17:12:36.590Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=1T6X3OJpbw",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/2o8selmiwn.json added

+++ b/reviews/openreview/chflih0ub0/notes/2o8selmiwn.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "2o8selMIwN",
+ "replyTo": "1T6X3OJpbw",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer w24A",
+ "content": {
+ "comment": "Thank you for your response, and for agreeing to rescope certain aspects based on our discussion. I am very happy with the work done during this rebuttal to extend the experimental setup, and especially in clarifying many of the points and positioning the paper properly. Most of my concerns have been addressed, and I am inclined to raise my score.\n\nOne final point about the BrainTreebank evaluation: I would like to note that the PopT BrainTreebank splits are well-known to contain significant train/test leakage [1, 2, 3], and have been corrected independently [1, 2]. The purpose of my question was to clarify whether these splits were used, since while existing works have pointed it out it is a subtle point that not everyone in the broader community may be aware of. That said, I know we're coming close to the end of the discussion portion, but if possible before it ends I'd like confirmation from the authors that they will check on this matter and promise to update their evaluation to a newer set of splits without leakage, without reporting any of the results containing leakage, in the revised manuscript.\n\n---\n\n[1] Zahorodnii, Andrii, Christopher Wang, Geeling Chau, Bennett Stankovits, Charikleia Moraitaki, Eli Gross, Alexander Brady, Andrei Barbu, Boris Katz, and Ila R. Fiete. \"Neuroprobe: Evaluating Intracranial Brain Responses to Naturalistic Stimuli.\" arXiv preprint arXiv:2509.21671 (2025).\n\n[2] Oganesian, Lucine L., Saba Hashemi, and Maryam Shanechi. \"BaRISTA: Brain scale informed spatiotemporal representation of human intracranial neural activity.\" Advances in Neural Information Processing Systems 38 (2026): 167161-167194.\n\n[3] Han, Danny Dongyeop, Yonghyeon Gwon, Ahhyun Lucy Lee, Taeyang Lee, Seong Jin Lee, Jubin Choi, Sebin Lee et al. \"DIVER-1: Scaling Intracranial EEG Foundation Models for Transferable Representations.\" arXiv preprint arXiv:2512.19097 (2025)."
+ },
+ "createdAt": "2026-08-04T10:02:34.137Z",
+ "modifiedAt": "2026-11-19T17:12:36.677Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=2o8selMIwN",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/5mzss3zga3.json added

+++ b/reviews/openreview/chflih0ub0/notes/5mzss3zga3.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "5mzsS3zgA3",
+ "replyTo": "8QudQdMDyz",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "# Letter to the Area Chair — Submission 27804 (CORTEG)",
+ "comment": "# Letter to the Area Chair — Submission 27804 (CORTEG) [part 3]\n## Why we believe this paper should be considered\n\n**1. It establishes a new research direction.**\nTo our knowledge, this is the first systematic study of transferring scalp-EEG foundation models to intracranial decoding across multiple datasets, modalities, and task types, with comparisons against task-specific ECoG models, random initialization, alternative scalp-EEG backbones, and three intracranial foundation models. The results open several concrete research directions, including improved backbone selection, adaptive fusion, task-specific feature streams, and analysis of which pretrained representations transfer across modalities.\n\n**2. It demonstrates that large pretrained models can be competitive on challenging continuous ECoG regression tasks.**\nContinuous finger-trajectory and auditory-envelope decoding have long been dominated by compact, participant-specific models. CORTEG reaches the strongest mean performance on both tasks while reusing a pretrained cross-subject representation. The additional BrainTreebank results further show that the framework generalizes from ECoG regression to sEEG classification and that pretrained initialization provides a substantial advantage over the same architecture trained from scratch.\n\n**3. It provides evidence that cross-subject data scaling matters for intracranial decoding.**\nAcross the evaluated datasets, pooled training improves the decoding performance. This suggests that assembling larger and more diverse intracranial datasets may be at least as important as increasing model size, which is an important but comparatively understudied direction in ECoG and sEEG research.\n\n**4. It provides a geometry-aware solution for heterogeneous ECoG recordings.**\nECoG electrode layouts vary substantially across patients because grids are implanted at different locations and with different geometries. CORTEG addresses this variability through a simple geometry-conditioned adapter that maps patient-specific electrode coordinates into a shared representation space. Our ablations show that this spatial adapter is critical to performance, providing an effective way to reuse cross-subject recordings despite heterogeneous electrode placement.\n\nTaken together, we believe the paper provides both strong empirical results and a credible foundation for a new line of work on cross-modality foundation-model transfer for intracranial decoding."
+ },
+ "createdAt": "2026-08-02T16:38:33.662Z",
+ "modifiedAt": "2026-11-19T17:12:36.914Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=5mzsS3zgA3",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/7dnrr0lhgh.json added

+++ b/reviews/openreview/chflih0ub0/notes/7dnrr0lhgh.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "7DNrr0LHgH",
+ "replyTo": "Pw5RZ4UfjP",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer w24A",
+ "content": {
+ "comment": "Thank you for confirming this. As to your own splits and evaluation setup, I can say, to the best of my memory, the main issue with PopT's splits is they had randomized selection of word onsets throughout the sessions, with no temporal blocking in place to prevent a 5s context window around one word in train from overlapping with 5s context of an adjacent test word. As long as you use a blocked design, or, better, causal/chronological train/val/test splits, and ensure no temporal overlap between context windows, then you should be fine."
+ },
+ "createdAt": "2026-08-04T10:29:34.973Z",
+ "modifiedAt": "2026-11-19T17:12:36.481Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=7DNrr0LHgH",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/7fdplhg5q1.json added

+++ b/reviews/openreview/chflih0ub0/notes/7fdplhg5q1.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "7fdPLHg5q1",
+ "replyTo": "1SJflYv6yM",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to reviewer NvGg",
+ "comment": "Dear Reviewer NvGg,\n\nThank you for your thoughtful reconsideration and for acknowledging the additional evidence. We appreciate your careful review and are pleased that the new comparisons with intracranial foundation models and the BrainTreebank evaluation have addressed your main concerns.\n\nBest regards,\n\nThe Authors"
+ },
+ "createdAt": "2026-08-04T08:53:40.583Z",
+ "modifiedAt": "2026-11-19T17:12:36.578Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=7fdPLHg5q1",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/8qudqdmdyz.json added

+++ b/reviews/openreview/chflih0ub0/notes/8qudqdmdyz.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "8QudQdMDyz",
+ "replyTo": "qncTcg7IYP",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "# Letter to the Area Chair — Submission 27804 (CORTEG)",
+ "comment": "# Letter to the Area Chair — Submission 27804 (CORTEG) [part 2]\n\n### C. Dual stream fusion and backbone model choice\n\n(1) Early fusion ablation was in our submission manuscript: `Appendix Table9`. Since we believe the choice of K is a hyperparameter, we provided our sweep in the appendix. Now, we additionally evaluated a layer-wise gated fusion variant CORTEG that learns the fusion at each layer and therefore avoids a separate manual sweep over K. As shown in Table 2, the gated model can perform as good as the original CORTEG. \n\n**Table 2. Layer-wise gated fusion compared with fixed-\\(K\\) mean-pooling.**\n\n| Task | Model size | Mean-pool \\(r\\) | Gated \\(r\\) | \\(Delta r\\) | Adjusted \\(p\\) | Subjects improved | Note |\n|---|---|---:|---:|---:|---:|---:|---|\n| Finger | Small | 0.5724 | 0.5747 | +0.002 | 0.73 | — | No meaningful change |\n| Finger | **Base** | 0.5732 | **0.5915** | **+0.018** | **0.008** | **8/9** | Significant improvement |\n| Finger | Large | 0.5691 | 0.5789 | +0.010 | 0.08 | — | No meaningful change |\n| Audio | Small | 0.3366 | 0.3220 | **−0.015** | **0.013** | 3/16 | Significant degradation |\n| Audio | Base | 0.2372 | **0.2814** | **+0.044** | **<0.001** | **15/16** | Significant improvement |\n| Audio | Large | 0.1940 | **0.3228** | **+0.129** | **<0.001** | **16/16** | Significant improvement |\n\n(2) To address the reviewer's concern about the EEG foundation model choice, and test if CORTEG highly depends on ST-EEGFormer, we repeated the full pipeline with REVE, another strong EEG FM. As shown in Table 3, REVE performs much better than CBraMod and LaBram. The dual-stream fusion strategy remains the strongest. These results show that CORTEG is not specific to ST-EEGFormer, while also indicating that effective transfer requires backbone-specific optimization and task-relevant feature design.\n\n**Table 3. CORTEG with REVE as the backbone model.**\n| Stream | Finger (r) | Audio (r) |\n| ------------------------------ | ---------: | --------: |\n| **Dual-stream CORTEG** | **0.529** | **0.293** |\n| High-gamma only | 0.514 | 0.190 |\n| Low-frequency only | 0.353 | 0.288 |\n| ST-EEGFormer CORTEG, submitted | 0.554 | 0.339 |\n| Ridge on raw high-gamma | 0.336 | 0.175 |\n\n\n## Camera-ready revisions\n\nThe camera-ready version will incorporate the main findings from the rebuttal:\n\n* **Add comparisons with intracranial foundation models.** BrainBERT, PopT, and Brant results will be added to the original finger and audio tasks and on BrainTreebank, clarifying how scalp-to-intracranial transfer compares with within-modality pretraining.\n* **Add public BrainTreebank validation.** The new sEEG sentence-onset experiment will provide additional evidence that CORTEG generalizes across intracranial modalities and from regression to classification.\n* **Extend the backbone ablation with REVE.** This experiment will show that the framework is not specific to ST-EEGFormer, while emphasizing the need for backbone-specific adaptation.\n* **Clarify the dual-stream interpretation.** We will highlight the task-dependent roles of the two streams: high-gamma is most important for finger decoding, whereas low-frequency representations dominate auditory envelope decoding. Early/late fusion, no-separation, and gated-fusion results will also be included."
+ },
+ "createdAt": "2026-08-02T16:37:20.809Z",
+ "modifiedAt": "2026-11-19T17:12:37.155Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=8QudQdMDyz",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/cfoc7pcq96.json added

+++ b/reviews/openreview/chflih0ub0/notes/cfoc7pcq96.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "cFoC7pcQ96",
+ "replyTo": "7DNrr0LHgH",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Thank you for your clear explaination",
+ "comment": "Thank you again for explaining this mechanism so clearly. This is indeed a subtle issue, and we appreciate the reviewer for bringing it to our attention. In the camera-ready version, we will rerun all comparisons using chronological splits with a sufficient gap between the training and test blocks. We will also explicitly verify that no training and test windows overlap and report only the results obtained under this revised protocol."
+ },
+ "createdAt": "2026-08-04T11:31:19.622Z",
+ "modifiedAt": "2026-11-19T17:12:36.451Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=cFoC7pcQ96",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/drnqtxhsgb.json added

+++ b/reviews/openreview/chflih0ub0/notes/drnqtxhsgb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "drNQtxHSgb",
+ "replyTo": "NO9rxhUvuG",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Additional ablation: REVE as a second EEG foundation model",
+ "comment": "## Additional ablation: REVE as a second EEG foundation model\n\nTo address the reviewer's concern about the EEG foundation model choice, and test if CORTEG highly depends on ST-EEGFormer, we repeated the full pipeline with REVE using pooled training and LoRA-only adaptation (479K trainable parameters, seed 42).\n\n| Stream | Finger (r) | Audio (r) |\n| ------------------------------ | ---------: | --------: |\n| **Dual-stream CORTEG** | **0.529** | **0.293** |\n| High-gamma only | 0.514 | 0.190 |\n| Low-frequency only | 0.353 | 0.288 |\n| ST-EEGFormer CORTEG, submitted | 0.554 | 0.339 |\n| Ridge on raw high-gamma | 0.336 | 0.175 |\n\n**1. The transfer framework generalizes to a second scalp-EEG backbone.**\nWith REVE replacing ST-EEGFormer, CORTEG retains 95% of the submitted finger-decoding performance and 86% of the auditory-decoding performance, while outperforming the raw high-gamma ridge baseline on both tasks. Achieving this performance required two REVE-specific adjustments: matching its documented input-magnitude convention and using denser training windows. This result suggests that the framework is not tied to a single pretrained backbone, although effective transfer still requires adaptation choices that respect each model’s original input and training conventions.\n\n**2. The dual-stream configuration remains the strongest on both tasks.**\nFor REVE, the dual-stream model achieves the highest mean performance for both finger and auditory decoding. Its advantage over the stronger single stream is modest and not statistically significant: (+0.015) for finger decoding ((p=0.20)) and (+0.005) for auditory decoding ((p=0.32)). This is consistent with the similarly modest, non-significant dual-stream advantage observed with ST-EEGFormer. We therefore interpret the two-stream design as providing a small but consistent benefit that is task-dependent.\n\n**3. The contribution of high-gamma information is strongly task-dependent.**\nFor finger decoding, the high-gamma-only stream substantially outperforms the low-frequency-only stream ((0.514) versus (0.353); (Delta r=+0.162)), with improvements for all 9 subjects and an exact Wilcoxon (p=0.004). For auditory decoding, the ordering reverses: the low-frequency-only stream outperforms the high-gamma-only stream ((0.288) versus (0.190); (Delta r=+0.098)), with improvements for 13 of 16 subjects ((p=0.003)).\n\nThis phenomenon again supports our task-dependent interpretation: finger decoding relies more strongly on focal high-gamma activity, whereas auditory decoding benefits primarily from low-frequency structure that is more closely aligned with the representations learned during scalp-EEG pretraining.\n\nWe believe this additional ablation provides strong evidence that CORTEG’s transferability is not specific to ST-EEGFormer and extends to a second scalp-EEG foundation model. Further gains may come from improved backbone selection, model-specific optimization, and alternative feature engineering, including replacing the fixed high-gamma stream with more task-relevant features."
+ },
+ "createdAt": "2026-07-31T06:42:44.684Z",
+ "modifiedAt": "2026-11-19T17:12:37.254Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=drNQtxHSgb",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/eycjgcdtmd.json modified

+++ b/reviews/openreview/chflih0ub0/notes/eycjgcdtmd.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair PXsu",
"content": {
- "metareview": "### Summary\nThis paper proposes CORTEG, a framework for adapting pretrained scalp-EEG foundation models (ST-EEGFormer) to intracranial ECoG decoding. The approach addresses modality gaps via: (1) a KNNSoftFourier spatial adapter mapping ECoG electrode coordinates into the EEG channel codebook, (2) a dual-stream tokenizer separating low-frequency and high-gamma activity, and (3) LoRA-based fine-tuning with a leave-one-subject-out (LOO-FT) strategy enabling rapid per-patient calibration. Evaluation on finger trajectory regression (public, n=9) and audio envelope regression (private, n=16) shows CORTEG achieves the highest mean correlation among compared methods, with statistically significant gains only on the audio task. Ablations reveal that the pretraining benefit is task-dependent — large for the audio task but modest for motor — raising questions about what fraction of performance stems from pretrained representations versus architectural innovations.\n\n### Strengths\n- Important and well-motivated problem. The paper addresses ECoG data scarcity and electrode variability — a genuine BCI deployment bottleneck (7Gx5: \"critical bottleneck in ECoG BCIs\"; NvGg: \"first systematic study of scalp-EEG → ECoG transfer\").\n- Well-designed spatial adapter. The KNNSoftFourier adapter provides a principled geometry bridge with Nadaraya-Watson initialization (7Gx5: \"interpretable, principled way to interpolate\"; NvGg: \"well-justified by neuroanatomy\").\n- Comprehensive and rigorous evaluation. 10+ baselines including ECoG-native task-specific models (DeepFingerNet, HiLoFuseNet), statistical testing, per-subject breakdowns, and thorough ablations (w24A: \"attention to detail in the experimental setup\"; 7Gx5: \"leave-one-subject-out setup paired with thorough ablations\").\n- Practical deployment contribution. LOO-FT achieves competitive performance with 10–30 minute calibration on a single GPU (NvGg).\nNeurophysiologically grounded analysis. Manifold analyses and electrode importance maps align with known neuroanatomy (w24A: \"promising to see emergent properties reflecting biological priors\").\n\n### Weaknesses\n- Core transfer claim weakly supported — non-significant on the public benchmark and reliant on private data for statistical significance. On the reproducible finger task, gains over the best baseline are non-significant, and the ablation reveals only a modest drop when removing pretraining, suggesting architecture and population training account for most performance (7Gx5: \"architectural design...not EEG pretraining — account for much of the observed performance\"; w24A: \"large gap in the fundamental argument\"). The statistically significant audio result, which provides the paper's strongest evidence, cannot be independently verified (7Gx5: \"strongest evidence relies on a private audio dataset\"; NvGg: \"no anonymized assets or URL were provided\").\n- No comparison with iEEG/ECoG foundation models. While the paper includes ECoG-native task-specific baselines and a from-scratch ablation (random init), it does not compare against existing intracranial foundation models. This comparison would directly test whether scalp-EEG FM transfer can compete with within-modality self-supervised pretraining on iEEG data (7Gx5: \"absence of a competitive ECoG-only population model weakens external validity\").\n- Dual-stream architecture incompletely ablated. No comparison against early fusion or no frequency separation, leaving late-fusion benefit unestablished (w24A: \"ablations only show the benefit over HF and LF components alone, not the combination with early fusion or no separation\"; NvGg: \"the paper does not verify the design intuition\").\n- Absence of scaling benefit undermines the foundation-model framing. Small, Base, and Large backbones perform equivalently (NvGg: \"Does the lack of scaling indicate limited ECoG data, architectural mismatch...or that scalp-EEG pretraining does not scale cleanly to ECoG?\").\n\n### What Would Change Acceptance Odds\nThis paper needs further clarification. To increase the odds toward acceptance, I suggest to prioritize these focus areas in the rebuttal:\nCompare against iEEG foundation models: The random-init ablation already shows the architecture trained from scratch on pooled ECoG. What remains unclear is how the proposed approach compares against existing iEEG FMs (e.g., Brant, BrainBERT).\nValidate on an additional public ECoG/iEEG dataset with the pretraining ablation: Since the statistically significant result relies on private data, demonstrating CORTEG on another publicly available ECoG dataset — and showing that EEG pretraining helps compared to random initialization on that dataset — would substantially strengthen the transfer claim on reproducible data."
+ "metareview": "### Summary\nThis paper proposes CORTEG, a framework for adapting pretrained scalp-EEG foundation models (ST-EEGFormer) to intracranial ECoG decoding. The approach addresses modality gaps via: (1) a KNNSoftFourier spatial adapter mapping ECoG electrode coordinates into the EEG channel codebook, (2) a dual-stream tokenizer separating low-frequency and high-gamma activity, and (3) LoRA-based fine-tuning with a leave-one-subject-out (LOO-FT) strategy enabling rapid per-patient calibration. Evaluation on finger trajectory regression (public, n=9) and audio envelope regression (private, n=16) shows CORTEG achieves the highest mean correlation among compared methods, with statistically significant gains only on the audio task. Ablations reveal that the pretraining benefit is task-dependent — large for the audio task but modest for motor — raising questions about what fraction of performance stems from pretrained representations versus architectural innovations.\n\n### Strengths\n- Important and well-motivated problem. The paper addresses ECoG data scarcity and electrode variability — a genuine BCI deployment bottleneck (7Gx5: \"critical bottleneck in ECoG BCIs\"; NvGg: \"first systematic study of scalp-EEG → ECoG transfer\").\n- Well-designed spatial adapter. The KNNSoftFourier adapter provides a principled geometry bridge with Nadaraya-Watson initialization (7Gx5: \"interpretable, principled way to interpolate\"; NvGg: \"well-justified by neuroanatomy\").\n- Comprehensive and rigorous evaluation. 10+ baselines including ECoG-native task-specific models (DeepFingerNet, HiLoFuseNet), statistical testing, per-subject breakdowns, and thorough ablations (w24A: \"attention to detail in the experimental setup\"; 7Gx5: \"leave-one-subject-out setup paired with thorough ablations\").\n- Practical deployment contribution. LOO-FT achieves competitive performance with 10–30 minute calibration on a single GPU (NvGg).\nNeurophysiologically grounded analysis. Manifold analyses and electrode importance maps align with known neuroanatomy (w24A: \"promising to see emergent properties reflecting biological priors\").\n\n### Weaknesses\n- Core transfer claim weakly supported — non-significant on the public benchmark and reliant on private data for statistical significance. On the reproducible finger task, gains over the best baseline are non-significant, and the ablation reveals only a modest drop when removing pretraining, suggesting architecture and population training account for most performance (7Gx5: \"architectural design...not EEG pretraining — account for much of the observed performance\"; w24A: \"large gap in the fundamental argument\"). The statistically significant audio result, which provides the paper's strongest evidence, cannot be independently verified (7Gx5: \"strongest evidence relies on a private audio dataset\"; NvGg: \"no anonymized assets or URL were provided\").\n- No comparison with iEEG/ECoG foundation models. While the paper includes ECoG-native task-specific baselines and a from-scratch ablation (random init), it does not compare against existing intracranial foundation models. This comparison would directly test whether scalp-EEG FM transfer can compete with within-modality self-supervised pretraining on iEEG data (7Gx5: \"absence of a competitive ECoG-only population model weakens external validity\").\n- Dual-stream architecture incompletely ablated. No comparison against early fusion or no frequency separation, leaving late-fusion benefit unestablished (w24A: \"ablations only show the benefit over HF and LF components alone, not the combination with early fusion or no separation\"; NvGg: \"the paper does not verify the design intuition\").\n- Absence of scaling benefit undermines the foundation-model framing. Small, Base, and Large backbones perform equivalently (NvGg: \"Does the lack of scaling indicate limited ECoG data, architectural mismatch...or that scalp-EEG pretraining does not scale cleanly to ECoG?\").\n\n### What Would Change Acceptance Odds\nThis paper needs further clarification. To increase the odds toward acceptance, I suggest to prioritize these focus areas in the rebuttal:\nCompare against iEEG foundation models: The random-init ablation already shows the architecture trained from scratch on pooled ECoG. What remains unclear is how the proposed approach compares against existing iEEG FMs (e.g., Brant, BrainBERT).\nValidate on an additional public ECoG/iEEG dataset with the pretraining ablation: Since the statistically significant result relies on private data, demonstrating CORTEG on another publicly available ECoG dataset — and showing that EEG pretraining helps compared to random initialization on that dataset — would substantially strengthen the transfer claim on reproducible data.",
+ "final_justification": "The authors were highly responsive, providing extensive new experiments directly addressing both prioritized questions from the initial meta-review. Reviewer engagement was asymmetric: w24A engaged deeply and raised their score from 3 to 5, championing acceptance; NvGg responded after a 6-day delay and raised from 3 to 4; 7Gx5 was unresponsive throughout the discussion period and is flagged accordingly.\n\nBoth critical rebuttal questions were satisfactorily addressed:\n- iEEG FM comparison: Brant, BrainBERT, and Population Transformer all performed below a simple ridge baseline on the paper's tasks, demonstrating that existing iEEG FMs do not transfer to continuous decoding — validating the cross-modality approach.\n- Additional public dataset with pretraining ablation: on BrainTreebank (public sEEG), CORTEG achieved 0.683 AUROC vs. 0.547 for random initialization, confirming pretraining benefit on reproducible data. CORTEG also outperformed all iEEG FMs on this benchmark.\n\nAdditionally, the REVE backbone ablation demonstrates framework generality beyond ST-EEGFormer.\n\nThe authors’ excellent rebuttal resolves the primary weaknesses identified in the initial meta-review. The paper now demonstrates that EEG FM transfer to ECoG/iEEG (a) outperforms domain-specific FMs, (b) benefits from pretraining on an additional public dataset, and (c) generalizes across FM backbones. Combined with the thorough evaluation, practical LOO-FT contribution, and honest reporting, the paper merits acceptance, conditioned on incorporating the new results in the final manuscript."
},
"createdAt": "2026-07-22T19:25:37.388Z",
- "modifiedAt": "2026-11-18T15:24:34.067Z",
+ "modifiedAt": "2026-11-19T05:02:53.125Z",
"url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=eyCJgCDTmD",
"license": "CC-BY-4.0"
}

reviews/openreview/chflih0ub0/notes/no9rxhuvug.json added

+++ b/reviews/openreview/chflih0ub0/notes/no9rxhuvug.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "NO9rxhUvuG",
+ "replyTo": "8nqSvR89ec",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "References",
+ "comment": "### References\n[1]Aristimunha, Bruno, et al. \"EEGDash: An open-source platform for machine learning on public neurophysiological data.\" arXiv preprint arXiv:2606.16041 (2026).\\\n[2]Willsey, Matthew S., et al. \"A high-performance brain–computer interface for finger decoding and quadcopter game control in an individual with paralysis.\" Nature Medicine 31.1 (2025): 96-104.\\\n[3]Littlejohn, Kaylo T., et al. \"A streaming brain-to-voice neuroprosthesis to restore naturalistic communication.\" Nature neuroscience 28.4 (2025): 902-912.\\\n[4]Ryoo, A. H. W., Krishna, N. H., Mao, X., Azabou, M., Dyer, E. L., Perich, M. G., & Lajoie, G. (2026). Generalizable, real-time neural decoding with hybrid state-space models. Advances in Neural Information Processing Systems, 38, 51764-51791.\\\n[5]Yang, Liuyin, et al. \"Are EEG foundation models worth it? comparative evaluation with traditional decoders in diverse BCI tasks.\" The Fourteenth International Conference on Learning Representations. 2026.\\\n[6]Aristimunha, Bruno, et al. \"Eeg foundation challenge: from cross-task to cross-subject eeg decoding.\" arXiv preprint arXiv:2506.19141 (2025).\\"
+ },
+ "createdAt": "2026-07-29T09:17:16.342Z",
+ "modifiedAt": "2026-11-19T17:12:37.036Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=NO9rxhUvuG",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/pw5rz4ufjp.json added

+++ b/reviews/openreview/chflih0ub0/notes/pw5rz4ufjp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Pw5RZ4UfjP",
+ "replyTo": "2o8selMIwN",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to reviewer w24A",
+ "comment": "Thank you for raising this important issue. We confirm that we did **not** use PopT’s train/test splits. We used only its subject/session selections for seven subjects and its `clean_laplacian` electrode list. Because our evaluation protocol was developed independently, we do not expect the same leakage issue to affect our current results.\n\nNevertheless, as we plan to report results for both our task and the original BrainTreebank task in the camera-ready version, we will thoroughly verify the splitting procedure and reproduce the published task using leakage-free splits. We will also document the evaluation protocol clearly in the revised manuscript.\n\nWe sincerely thank the reviewer for bringing this subtle but important issue to our attention, as we were not previously aware of it."
+ },
+ "createdAt": "2026-08-04T10:18:09.066Z",
+ "modifiedAt": "2026-11-19T17:12:36.627Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=Pw5RZ4UfjP",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/qnctcg7iyp.json added

+++ b/reviews/openreview/chflih0ub0/notes/qnctcg7iyp.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "qncTcg7IYP",
+ "replyTo": "eyCJgCDTmD",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "# Letter to the Area Chair — Submission 27804 (CORTEG)",
+ "comment": "# Letter to the Area Chair — Submission 27804 (CORTEG) [part 1]\n\n\nFirst, we thank the reviewers and AC for their time and constructive feedback, which helped us substantially strengthen the paper. The meta-review highlights two central priorities: comparison with intracranial foundation models and validation on an additional public dataset. We addressed both through extensive new experiments. Although we regret that no further reviewer responses were posted to discuss this evidence, we use this final statement to summarize the main findings and their implications for the paper.\n\n\n## New evidence\n\n### A. Comparison with intracranial foundation models\n\nWe first benchmarked BrainBERT, PopT, and Brant on our finger-trajectory and auditory-envelope regression tasks. As shown in Table 1, all three intracranial foundation models underperform a simple high-gamma ridge baseline, revealing a clear gap in adapting current intracranial foundation models to challenging continuous ECoG regression.\n\n\n**Table 1: within-modality comparison results, across evaluation splits (mean Pearson *r*)**\n\nSplits: **pop** = pooled/population, **p-s** = per-subject, **LOSO** = leave-one-subject-out (for CORTEG: pooled / per-subject / LOO-FT). The frozen-probe rows and CORTEG cover all three splits.\n\n| Model (~total trainable) | Adaptation (trainable) | Finger · pop | · p-s | · LOSO | Audio · pop | · p-s | · LOSO |\n|---|---|---|---|---|---|---|---|\n| **BrainBERT** (~43 M) | frozen probe (**~3.8 K** head) | 0.030 | 0.039 | 0.044 | 0.031 | 0.052 | 0.050 |\n| **PopT** (~20 M) | frozen probe (**~2.6 K** head) | 0.040 | 0.049 | 0.050 | 0.031 | 0.038 | 0.039 |\n| **CORTEG (ours)** (~33 M) | LoRA + adapter (**297 K**) | **0.554** | 0.539 | 0.551 | **0.339** | 0.250 | 0.331 |\n| **Raw-HGA baseline** | ridge / linear | 0.336 | | | 0.175 | | |\n\n*Bigger models and more adaptation do not close the gap.* **Brant** (~506 M, frozen, ~10 K linear head, native 6 s context) reaches only **0.028 / 0.022**; and for BrainBERT / PopT, **full fine-tuning** (finger 0.040 / 0.053), a **trained BiLSTM temporal head** (0.053 / 0.063), and **end-to-end last-*N* fine-tuning** (collapses to ≤0.012) all stay **≤0.063 on finger and ≤0.057 on audio — below even the raw-HGA ridge**. \n\n### B. Validation on the BrainTreebank sEEG classification task\n\nTo verify our approach's generalization, we evaluated CORTEG against three pretrained intracranial foundation models on the 10-subject BrainTreebank sentence-onset classification task.\n\n| Model | AUROC |\n| ----------------------------- | --------: |\n| **CORTEG** | **0.683** |\n| PopT | 0.605 |\n| BrainBERT | 0.565 |\n| Brant | 0.519 |\n| CORTEG, random initialization | 0.547 |\n| HiLoFuseNet | 0.566 |\n| CNN_LSTM | 0.526 |\n| Raw band-power ridge | 0.535 |\n\nThese results show that CORTEG generalizes beyond the original ECoG regression setting to sEEG classification, while maintaining strong performance across different intracranial modalities and task formulations. Under the evaluated protocols, all three iEEG-pretrained models perform worse than CORTEG, further supporting the effectiveness of transferring a scalp-EEG foundation model through the proposed framework."
+ },
+ "createdAt": "2026-08-02T16:35:49.388Z",
+ "modifiedAt": "2026-11-19T17:12:37.160Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=qncTcg7IYP",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/t7qcwwrsso.json added

+++ b/reviews/openreview/chflih0ub0/notes/t7qcwwrsso.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "t7qCwwRSSo",
+ "replyTo": "cFoC7pcQ96",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer w24A",
+ "content": {
+ "comment": "Excellent. Thank you for your all your work and attention to detail. I will raise my score to a 5 in my final assessment."
+ },
+ "createdAt": "2026-08-04T11:36:09.896Z",
+ "modifiedAt": "2026-11-19T17:12:36.319Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=t7qCwwRSSo",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/vdmmpjjiop.json added

+++ b/reviews/openreview/chflih0ub0/notes/vdmmpjjiop.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "vdMmpjjIOp",
+ "replyTo": null,
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Area Chair PXsu",
+ "content": {
+ "title": "Gentle Reminder that Author and Reviewer Discussion Period is Ending",
+ "comment": "Dear Reviewers and Authors of Submission #27804 ,\n\nThis is a quick reminder that the discussion period with authors is ending on August 3rd. If you are a reviewer and need any clarifications based on the authors' rebuttal, please reach out soon.\n\nYour, AC"
+ },
+ "createdAt": "2026-08-02T20:44:55.102Z",
+ "modifiedAt": "2026-11-19T17:12:36.911Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=vdMmpjjIOp",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/wabqeffwnc.json added

+++ b/reviews/openreview/chflih0ub0/notes/wabqeffwnc.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "wABQefFwnc",
+ "replyTo": "8nqSvR89ec",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer w24A",
+ "content": {
+ "comment": "I would like to thank the authors for their extensive work on this rebuttal and new experiments. Below I comment one each of my prior concerns following the authors' responses.\n\n**(W1)**: Thank you for clarifying and expanding on the motivation. I think this vastly improves the scope of the paper. One point I especially appreciate is that while iEEG foundation models are far from being able to be used out-of-the-box and prior works sometimes neglected to account for this in comparisons (c.f. Neuroprobe's most recent manuscript and leaderboard results, comparing off-the-shelf variants of some pretrained models versus new ones trained from scratch on Brain Treebank, and showing a significant gap in performance [1]), EEG foundation models can be transferred off-the-shelf quite well to iEEG. Consider this concern addressed.\n\n**(W2)**: Thank you for including these new experiments. One clarifying question here: are the iEEG pretrained models you're using here taken off-the-shelf or re-pretrained on the training set of the ECoG data? Referring back to my last comment on W1, I think either direction is fine based on my new understanding of the scope of this paper, but it should at least be clarified. I also think discussing the point that pretraining on the downstream ECoG data is not really the purpose of this study could be helpful, as I'm sure some readers might initially have this concern. Nonetheless, consider this concern addressed.\n\n**(W3)**: Thank you for clarifying this, I did not see Appendix Table 9 before. Also I appreciate the addition of the gated fusion mechanism, and agree this would be an interesting subject of future work. Just make sure to mention that the fusion is only needed because of transfer from EEG (or at least that is what the current results support), but the fact that this surfaced from this study, being the first in-depth study of EEG-to-iEEG transfer, is quite interesting in its own rite. Consider this concern addressed.\n\n**(Q1)**: Thank you for including the comparison with REVE. I agree this confirms that CORTEG is a general framework that can enable strong cross-modality transfer from EEG foundation models in general, not just ST-EEGFormer, and I think this preliminary backbone comparison opens the door for thinking about EEG models from a modality transfer perspective, which can be useful for future works on making EEG FMs more general along new axes. Consider this concern addressed.\n\n**(Q2/3)**: Thank you for clarifying. Please make sure to include these details in the manuscript if not there already. Consider this concern addressed.\n\n---\n\nI also noticed on the rebuttal for 7Gx5's review that you included BrainTreebank as an additional downstream evaluation. I think this is a very nice result to add, since it demonstrates CORTEG's transfer capability on a new task domain as well as a new intracranial modality.\n\nI'm wondering how you defined the splits for this evaluation? Were they borrowed from another paper/codebase?\n\nI see this comment from your response:\n\n> ... because of rebuttal-time compute constraints, we did not exhaustively fine-tune every intracranial FM on BrainTreebank. We therefore do not use Table 3 to claim that CORTEG universally outperforms these models. \n\nIf splits were borrowed from another paper, did that paper not already feature iEEG FM baselines you can directly compare to? \n\n---\n\n[1] Zahorodnii, Andrii, Christopher Wang, Geeling Chau, Bennett Stankovits, Charikleia Moraitaki, Eli Gross, Alexander Brady, Andrei Barbu, Boris Katz, and Ila R. Fiete. \"Neuroprobe: Evaluating Intracranial Brain Responses to Naturalistic Stimuli.\" arXiv preprint arXiv:2509.21671 (2025)."
+ },
+ "createdAt": "2026-08-03T15:54:02.832Z",
+ "modifiedAt": "2026-11-19T17:12:36.923Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=wABQefFwnc",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/chflih0ub0/notes/xnojx87xnb.json added

+++ b/reviews/openreview/chflih0ub0/notes/xnojx87xnb.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "XnOjX87XnB",
+ "replyTo": "wABQefFwnc",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response to reviewer w24A [part1]",
+ "comment": "We first would love to thank the reviewer for his/her careful follow-up review and for pointing us to Neuroprobe. Your comment helped us clarify the main question of the paper: **can an already released neural-signal foundation model transfer to a new intracranial cohort without another large pretraining stage?** We provide additional clarification below in response to the reviewer’s questions.\n### 1. Off-the-shelf initialization, with downstream adaptation\n\nBrainBERT, PopT, and Brant all start from their officially released pretrained checkpoints. None was re-pretrained on our downstream task data.\n\nBy *off-the-shelf*, we mean that we did not perform another self-supervised pretraining on the target dataset. It does not mean that every model stayed frozen during downstream evaluation. For BrainBERT and PopT, we tested frozen probing, a trained temporal head, full fine-tuning, and last-\\(N\\)-layer fine-tuning where supported. Brant was evaluated using the frozen representation exposed by its released code. None of these settings became competitive with CORTEG on the two continuous regression tasks.\n\nWe agree that re-pretraining an intracranial model on the downstream corpus would answer a different and valuable question. Our study instead focuses on the practical case in which a group starts from a released checkpoint and adapts it to a new cohort. We will make this distinction explicit and cite Neuroprobe as related evidence that off-the-shelf transfer and target-corpus training can lead to very different results.\n\n#### Additional interesting findings\nWe also would like to mention that we did not stop at the shipped configurations. The unexpectedly low performance from the pretrained intracranial foundation models prompted further investigation, we therefore ran a dense sweep over how each model is *used*: including window length, temporal pooling, and representation readout. We did find improved decoding performance with model-specific optimization. For example, the representation readout is very important, by replacing a pooled embedding with a per-electrode ridge ensemble, we could lift frozen BrainBERT from r = 0.033 to **0.166** and PopT from 0.046 to **0.179** (p < 0.0001). As for Brant, the lever is window length, by increasing the window length from 1 s to 6 s, we could improve the correlation from 0.059 to **0.107** (p = 0.029). \n\nThese results suggest that intracranial foundation models (or neural foundation models in general) still have substantial room for improvement, particularly through model- and task-specific optimization such as window length and representation readout. They also indicate that benchmarks based on a single fixed configuration may disadvantage models whose optimal use differs from the default setting. More broadly, understanding how to use existing neural foundation models effectively may be as important as developing new ones. We would welcome the opportunity to discuss these findings with researchers working on intracranial foundation models and benchmarking at the conference.\n\n### 2. Fusion is specific to EEG-to-iEEG transfer\n\nWe agree with this interpretation. The high-gamma stream is needed because the scalp-EEG backbone was pretrained in a frequency range that does not include the high-gamma activity important for finger decoding. The additional stream therefore supplies information that the transferred EEG representation does not adequately preserve.\n\nOur results support this design for EEG-to-iEEG transfer. They do not show that an intracranially pretrained model would need the same fusion mechanism. We will make this scope clear. The experiments also reveal a clear task-dependent difference: high-gamma activity contributes more to finger decoding, whereas low-frequency activity is more informative for auditory-envelope decoding. This suggests that other task-specific features could be designed and integrated within the CORTEG framework."
+ },
+ "createdAt": "2026-08-04T08:49:49.032Z",
+ "modifiedAt": "2026-11-19T17:12:36.598Z",
+ "url": "https://openreview.net/forum?id=ChfliH0uB0&noteId=XnOjX87XnB",
+ "license": "CC-BY-4.0"
+}