Evidence

reviews/openreview/sfz1prmige/notes/3z6n9aeq7a.json added

+++ b/reviews/openreview/sfz1prmige/notes/3z6n9aeq7a.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "3z6N9aEQ7A",
+ "replyTo": "8UNfyJE6VK",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "comment": "Thank you for maintaining your rating, and for the specific figure critique. Below we report the lesion-stratified evaluation and describe the figure revisions.\n\n**Lesion-stratified evaluation.** The held-out missing-MR subjects have no released lesion masks, so we built a separate leakage-free split: 200 mask-bearing subjects, stratified by whole-tumour-volume decile, were held out, and both the full model and a no-mapper control were retrained per contrast without them. Lesions follow the BraTS-2023 lesion-wise convention (26-connectivity components, ground-truth dilation, 2 mm³ threshold) on the whole-tumour region. Measurements are aggregated within each patient, so patients are the sampling unit; p-values are two-sided paired Wilcoxon and intervals are 95% percentile bootstrap.\n\n| Contrast | Δ lesion PSNR (dB) | 95% CI | p | Δ lesion SSIM | Δz error reduction |\n| :------- | ---------: | :--------------- | --------: | ---------: | -----------------: |\n| t2f | +0.469 | [+0.268, +0.677] | 2.7×10⁻⁵ | +0.0166 | 3.6% |\n| t1c | +0.038 | [−0.073, +0.150] | 0.64 | +0.0070 | 2.2% |\n| t2w | −0.084 | [−0.194, +0.025] | 0.16 | +0.0048 | 3.7% |\n| t1n | +0.255 | [+0.103, +0.410] | 0.0016 | +0.0061 | 2.8% |\n\nLesion SSIM improves significantly on all four contrasts (all p < 10⁻⁵), as does lesion-region through-plane error — the adjacent-slice derivative error |Δ_z Ŷ − Δ_z Y| restricted to the lesion region (all p < 10⁻¹⁸). Lesion PSNR improves significantly for t2f and t1n, while the differences for t1c and t2w are statistically inconclusive. The structural measures most directly related to the concern raised therefore improve consistently, whereas the lesion-PSNR evidence is contrast dependent.\n\n**The sharpest transitions specifically.** An average over the whole lesion can obscure the abrupt transitions most susceptible to smoothing. Within each patient, we ranked lesion-region through-plane transitions by the ground-truth magnitude |Δ_z Y| and retained the top 10% before comparing the models. Measurements are aggregated per patient, so patients remain the sampling unit.\n\n| Contrast | Δz error reduction | Relative | 95% CI | p | Bonferroni |\n| :------- | -----------------: | -------: | :------------------- | --------: | ---------: |\n| t2f | +0.00196 | 2.6% | [+0.00149, +0.00245] | 2×10⁻¹⁶ | 9×10⁻¹⁶ |\n| t1n | +0.00030 | 0.5% | [+0.00004, +0.00056] | 0.003 | 0.011 |\n| t2w | +0.00031 | 0.5% | [+0.00006, +0.00054] | 0.007 | 0.029 |\n| t1c | −0.00004 | −0.03% | [−0.00026, +0.00016] | 0.84 | 1.0 |\n\nThree contrasts improve and remain significant after Bonferroni correction across the four tests. For t1c the estimated difference is near zero and statistically inconclusive, the interval bounding it between −0.17% and +0.10% of that contrast's baseline error.\n\nAlthough neighbouring conditioning vectors are organised along depth, the output is not constrained to change smoothly. Slice-specific information reaches the decoder through the unchanged 2D encoder and skip connections, while the through-plane loss matches the prediction's slice-to-slice derivative to the ground-truth derivative rather than penalising large derivatives. Abrupt changes in the target therefore remain part of the training signal.\n\nThis controlled comparison directly tests whether the trajectory module smooths lesion transitions. It improves sharp-transition reconstruction on three contrasts, while the t1c estimate is near zero and tightly bounded. The comparison isolates the module's effect but does not by itself establish absolute lesion fidelity.\n\n**Figures 1 and 2.** We sincerely appreciate the reviewer identifying these presentation issues. We have rebuilt both figures in our working revision, though the discussion period does not permit uploading the revised PDF. One shape and stroke grammar now distinguishes frozen from learned components and data flow from gradient flow, with a single palette across both figures. The layout runs left to right on a shared column grid, so the pipeline reads in one direction. Every thumbnail carries its tensor shape and is marked as either a real sample or a schematic. Panel indices are referenced explicitly in the captions or removed. Both figures are rebuilt as vector art, so text is rendered as text rather than as an image. Figure 1 is additionally labelled a conceptual overview and split into separate LiFT-U and LiFT-C diagrams, so the shared principle and the task-specific realisations no longer share one panel.\n\nWe thank the reviewer for these questions, which helped us evaluate the specific failure mode more directly."
+ },
+ "createdAt": "2026-08-04T06:15:37.743Z",
+ "modifiedAt": "2026-11-19T16:46:16.870Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=3z6N9aEQ7A",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sfz1prmige/notes/8eclzouj1r.json added

+++ b/reviews/openreview/sfz1prmige/notes/8eclzouj1r.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "8ecLzoUj1r",
+ "replyTo": "dMqlKJloiz",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer PQnz",
+ "content": {
+ "comment": "Thank you for the detailed response. The additional coherence evaluation, architectural clarification, and depth-only ablation address several of my concerns. However, some important issues remain. The comparison with competitive 2D-lifting methods is still incomplete, and the new coherence results would benefit from stronger statistical analysis and more meaningful baselines. The exact implementation details and revised figures should also be included in the paper.\n\nA major concern is still the lack of care in the current figures. The inconsistent legends and unclear correspondence between the diagrams and equations suggest that the possibly AI-assisted figures were not carefully checked or post-edited. Since the figures describe the central method, this significantly affects the clarity and reliability of the presentation.\n\nOverall, the rebuttal provides useful new evidence, so I am willing to raise my score to 3. The paper still requires further refinement before it can be accepted."
+ },
+ "createdAt": "2026-08-01T06:56:18.219Z",
+ "modifiedAt": "2026-11-19T16:46:17.005Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=8ecLzoUj1r",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sfz1prmige/notes/8unfyje6vk.json added

+++ b/reviews/openreview/sfz1prmige/notes/8unfyje6vk.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "8UNfyJE6VK",
+ "replyTo": "4j3FbXMiHM",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer Ps2v",
+ "content": {
+ "comment": "Thank you for these insights. New quantitative evidence and details provided to other reviewers further strengthens the paper from our point of view. We maintain our rating.\n\nFrom our side, we also see improvement potential in figures 1 and 2, and we also believe these are AI-generated and need some additional work. The issue is primarily in the lack of a single visual vocabulary and of a clear flow/rhythm in the layout. One also gets an ambiguous feeling whether the image thumbnails represent real tensors. Internal indexing (a-b-c), (1-2-3) is never used in the caption, and text is poorly rasterized. We believe these figures should be carefully re-done, however this is not a ground for reducing the rating from our side."
+ },
+ "createdAt": "2026-08-03T00:00:38.431Z",
+ "modifiedAt": "2026-11-19T16:46:17.010Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=8UNfyJE6VK",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sfz1prmige/notes/crvgibr5e2.json modified

+++ b/reviews/openreview/sfz1prmige/notes/crvgibr5e2.json
@@ -5,11 +5,12 @@
"kind": "meta_review",
"invitation": "Meta_Review",
"signature": "Area Chair 844g",
"content": {
- "metareview": "This paper proposes a 3D medical image synthesis method by integrating 2D slice generators. While the reviewers agree that the task is well motivated and the proposed solution is generally sound, they also raised concerns regarding the missing comparisons against SOTA methods, inadequate analysis, insufficient technical innovations, insufficient clinical evidence, and missing technical details and confusing presentation. The authors are encouraged to carefully review the reviewers' comments and address all concerns in the rebuttal.\n\n---\n\nFinal meta-review: the rebuttal provided additional results, including new baselines, statistical analysis, coherence and lesion-level evaluations, and the requested ablations, directly addressing the reviewers' concerns. Nevertheless, several limitations still remain: there newly provided results weren't sufficiently documented, the revised model differs somewhat from the submitted one, and the anatomical/clinical evaluation is still fairly coarse. As a result of the rebuttal, two reviewers increased their scores after the rebuttal, resulting in final ratings of 4/5/3.\n\nOverall, the area chairs agree with the reviewers' assessments and find the merits outweigh the current limitations. The factorization is simple, the efficiency gains are large, and what's left is mostly documentation and scoping rather than the validity of the results. Hence, the area chairs recommend to accept the submission. However, the authors will have to incorporate substantial changes in the revision, including the new benchmark results, ablations, and revised figures, documenting the new protocols and flag which configuration was used where, and carefully scoping their claims to the evaluated brain-imaging tasks rather than broad clinical validity."
+ "metareview": "This paper proposes a 3D medical image synthesis method by integrating 2D slice generators. While the reviewers agree that the task is well motivated and the proposed solution is generally sound, they also raised concerns regarding the missing comparisons against SOTA methods, inadequate analysis, insufficient technical innovations, insufficient clinical evidence, and missing technical details and confusing presentation. The authors are encouraged to carefully review the reviewers' comments and address all concerns in the rebuttal.\n\n---\n\nFinal meta-review: the rebuttal provided additional results, including new baselines, statistical analysis, coherence and lesion-level evaluations, and the requested ablations, directly addressing the reviewers' concerns. Nevertheless, several limitations still remain: there newly provided results weren't sufficiently documented, the revised model differs somewhat from the submitted one, and the anatomical/clinical evaluation is still fairly coarse. As a result of the rebuttal, two reviewers increased their scores after the rebuttal, resulting in final ratings of 4/5/3.\n\nOverall, the area chairs agree with the reviewers' assessments and find the merits outweigh the current limitations. The factorization is simple, the efficiency gains are large, and what's left is mostly documentation and scoping rather than the validity of the results. Hence, the area chairs recommend to accept the submission. However, the authors will have to incorporate substantial changes in the revision, including the new benchmark results, ablations, and revised figures, documenting the new protocols and flag which configuration was used where, and carefully scoping their claims to the evaluated brain-imaging tasks rather than broad clinical validity.",
+ "final_justification": "Overall, the area chairs agree with the reviewers' assessments and find the merits outweigh the current limitations. The factorization is simple, the efficiency gains are large, and what's left is mostly documentation and scoping rather than the validity of the results. Hence, the area chairs recommend to accept the submission. However, the authors will have to incorporate substantial changes in the revision, including the new benchmark results, ablations, and revised figures, documenting the new protocols and flag which configuration was used where, and carefully scoping their claims to the evaluated brain-imaging tasks rather than broad clinical validity."
},
"createdAt": "2026-07-22T13:37:58.470Z",
- "modifiedAt": "2026-11-18T15:25:03.411Z",
+ "modifiedAt": "2026-11-19T05:03:11.564Z",
"url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=CrVGIBR5E2",
"license": "CC-BY-4.0"
}

reviews/openreview/sfz1prmige/notes/d5dfeyfckq.json added

+++ b/reviews/openreview/sfz1prmige/notes/d5dfeyfckq.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "d5DfEyfckQ",
+ "replyTo": "Hhp4SjmdMS",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response 4/4",
+ "comment": "**Lesion-level evaluation.** Where lesion ground truth exists, we evaluate pathology directly. The 219 missing-MR evaluation subjects have no released lesion masks, so this uses a separate leakage-free split: 200 mask-bearing subjects, stratified by whole-tumour-volume decile (20 per decile), were held out, and both the full model and the no-mapper control were retrained per contrast without them. Lesions are defined using the BraTS-2023 lesion-wise convention (26-connectivity components, ground-truth dilation, 2 mm³ expert-panel threshold) applied to the whole-tumour region, yielding 257 components across the 200 patients. PSNR is computed per component; SSIM and through-plane error are computed over each patient's whole lesion region. All measurements are aggregated within each patient, so patients are the sampling unit; p-values are two-sided paired Wilcoxon and intervals are 95% percentile bootstrap (10,000 resamples).\n\n| Contrast | ΔPSNR (dB) | 95% CI | p | Δ lesion SSIM | Δz error reduction |\n| :------- | ---------: | :--------------- | --------: | ------------: | -----------------: |\n| t2f | +0.469 | [+0.268, +0.677] | 2.7×10⁻⁵ | +0.0166 | 3.6% |\n| t1c | +0.038 | [−0.073, +0.150] | 0.64 | +0.0070 | 2.2% |\n| t2w | −0.084 | [−0.194, +0.025] | 0.16 | +0.0048 | 3.7% |\n| t1n | +0.255 | [+0.103, +0.410] | 0.0016 | +0.0061 | 2.8% |\n\nLesion SSIM improves significantly on all four contrasts (all p < 10⁻⁵), as does through-plane error — the adjacent-slice derivative error |Δ_z Ŷ − Δ_z Y| restricted to the lesion region, which is the quantity the through-plane loss optimizes (all p < 10⁻¹⁸). The two contrasts without a PSNR gain still improve on both structural measures. This analysis addresses lesion preservation in paired missing-MR synthesis; it does not provide pathology-aware validation of unconditional LiFT-U.\n\n**Make-A-Volume comparison.** Beyond the architectural distinction described in our previous response, the matched inference-cost measurements are now complete:\n\n| Model | Time/volume | Parameters |\n| :------------ | ------------: | -----------: |\n| LiFT-C | 1.159 s | 41.3 M |\n| Fast-cWDM | 15.53 s | 81.5 M |\n| cWDM | 156.4 s | 81.5 M |\n| Make-A-Volume | 192.9 s | 423.2 M |\n\nMake-A-Volume is 166× slower and 10.2× larger than LiFT-C under the matched inference setup. We began training it for the matched quality comparison as well, but the compute it requires is more than the discussion window allows, so we report cost only. That row does not depend on training state: parameter count and per-volume latency are fixed by the architecture and the sampler, and Make-A-Volume's second-stage temporal parameters are identity-initialized, so an untrained second stage executes the same sequence of operations as a trained one. This is therefore a matched inference-cost comparison, not a matched quality comparison.\n\n**Relationship to 2D-lifting models.** TCAM-Diff uses triplanes as the generative representation from which the volume is decoded, with diffusion operating directly on the plane features. In LiFT-U, axial, coronal, and sagittal features are used only in the training objective; no triplane representation exists at inference, and synthesis remains slice-based. TCAM-Diff therefore reduces the cost of volumetric diffusion, whereas LiFT-U learns through-plane organization for a 2D generator.\n\n**The contribution.** The result we report is that the third dimension of a medical volume can be carried by a low-dimensional trajectory rather than reconstructed by volumetric computation: anatomy varies smoothly along the through-plane axis, and a lightweight module, sitting outside the synthesis path, organizes independently synthesized slices into volumes whose inter-slice consistency and midplane symmetry are comparable to the corresponding real-data reference values, and the trajectory representation demonstrably encodes anatomical content such as lesion location. This is a statement about the problem, not only about our architecture, and it has a direct consequence: the volumetric and 2D-lifting baselines we measured place 3D capacity inside the generative path, and against every volumetric baseline we evaluated on quality, LiFT is comparable at 13–390× lower inference cost. We therefore regard the factorization, rather than any individual component, as the contribution, and we agree with the reviewer that its significance is practical.\n\nWe have carefully revised the manuscript to incorporate the updated analyses and will ensure that all corresponding changes are reflected accurately. We sincerely appreciate the reviewer’s comments, which have significantly strengthened this work."
+ },
+ "createdAt": "2026-08-03T22:08:48.193Z",
+ "modifiedAt": "2026-11-19T16:46:16.897Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=d5DfEyfckQ",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sfz1prmige/notes/dcorsfukx8.json added

+++ b/reviews/openreview/sfz1prmige/notes/dcorsfukx8.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "DcorsfUKx8",
+ "replyTo": "Yl68EKRCNV",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response 3/4",
+ "comment": "**Anatomy-aware evaluation.** We added two measures of coarse whole-brain structural coherence, computed on SynthSeg brain masks. Both are available from T1n alone, which is all that unconditional LiFT-U produces. (BraTS tumour segmentation requires T1c, T2w and T2f, so tumour-shape statistics are not obtainable for unconditional samples.) All groups use 200 volumes.\n\nInter-slice consistency (ISC) measures the overlap between the brain masks of adjacent slices, computed separately along each axis. Midplane-symmetry Dice measures the overlap between the brain mask and its mirror image across the mid-sagittal plane.\n\n| Group | ISC sagittal | ISC coronal | ISC axial | ISC-min | Symmetry Dice | Segmented |\n| :------------------------------- | -----------: | ----------: | --------: | ------: | ------------: | --------: |\n| Real | 0.855 | 0.875 | 0.864 | 0.854 | 0.895 | 200/200 |\n| LiFT-U | 0.859 | 0.874 | 0.872 | 0.859 | 0.897 | 200/200 |\n| WDM | 0.856 | 0.874 | 0.864 | 0.855 | 0.907 | 200/200 |\n| MAISI-v2 | 0.863 | 0.888 | 0.874 | 0.863 | 0.878 | 200/200 |\n| 3D MedDiffusion | 0.853 | 0.873 | 0.865 | 0.853 | 0.912 | 200/200 |\n| Shuffle sagittal (within-volume) | 0.000 | 0.773 | 0.739 | 0.000 | 0.000 | 170/200 |\n| Shuffle coronal (within-volume) | 0.746 | 0.601 | 0.764 | 0.601 | 0.064 | 132/200 |\n| Shuffle axial (within-volume) | 0.717 | 0.691 | 0.069 | 0.069 | 0.210 | 151/200 |\n| Shuffle axial (cross-volume) | 0.649 | 0.667 | 0.325 | 0.323 | 0.081 | 22/200 |\n\nLiFT-U synthesizes volumes by stacking axial slices, so any artefact of that stacking would appear in the axial column; LiFT-U scores 0.872 there, against 0.864 for real data. All four generators show broadly similar whole-brain-mask consistency to real data across the three axes and are segmented in every case, 200 of 200. We report these as evidence of coarse whole-brain structural coherence rather than as a ranking of the generators. The shuffled rows are negative controls: each takes a real volume and permutes its own slices along one axis, leaving the slice content unchanged and destroying only the ordering. SynthSeg failed to segment 15–34% of the within-volume controls and 89% of the cross-volume control; among those that did segment, consistency falls furthest on the axis that was shuffled — 0.000, 0.601 and 0.069 respectively. In the cross-volume control, each slice remains at its correct anatomical depth but is drawn from a different subject. Any evaluation that treats axial slices independently and aggregates over the preserved slice distribution therefore cannot distinguish this control by construction. Its values are computed over the 22 volumes that segmented. These mask-based measures do not establish tumour validity, detailed anatomical equivalence, or clinical utility. We agree with the reviewer on the importance of clinical review and are actively pursuing it, but completing that evaluation is beyond the scope of this revision."
+ },
+ "createdAt": "2026-08-03T22:03:36.527Z",
+ "modifiedAt": "2026-11-19T16:46:17.202Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=DcorsfUKx8",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sfz1prmige/notes/joh7fspzmx.json added

+++ b/reviews/openreview/sfz1prmige/notes/joh7fspzmx.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "JOH7FsPZmx",
+ "replyTo": "XJIdAFHUnT",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response 3/3",
+ "comment": "**Direct coherence evaluation for LiFT-U, against competing generators.** For the unconditional setting the comparison is against real data and three 3D-native generators rather than an ablation, over 200 volumes per group. On SynthSeg brain masks we measure inter-slice consistency (overlap between adjacent slices' masks, per axis) and midplane-symmetry Dice. The shuffle controls permute a real volume's own slices along one axis, changing only the ordering.\n\n| Group | ISC sagittal | ISC coronal | ISC axial | ISC-min | Symmetry Dice | Segmented |\n| :------------------------------- | -----------: | ----------: | --------: | ------: | ------------: | --------: |\n| Real | 0.855 | 0.875 | 0.864 | 0.854 | 0.895 | 200/200 |\n| LiFT-U | 0.859 | 0.874 | 0.872 | 0.859 | 0.897 | 200/200 |\n| WDM | 0.856 | 0.874 | 0.864 | 0.855 | 0.907 | 200/200 |\n| MAISI-v2 | 0.863 | 0.888 | 0.874 | 0.863 | 0.878 | 200/200 |\n| 3D MedDiffusion | 0.853 | 0.873 | 0.865 | 0.853 | 0.912 | 200/200 |\n| Shuffle sagittal (within-volume) | 0.000 | 0.773 | 0.739 | 0.000 | 0.000 | 170/200 |\n| Shuffle coronal (within-volume) | 0.746 | 0.601 | 0.764 | 0.601 | 0.064 | 132/200 |\n| Shuffle axial (within-volume) | 0.717 | 0.691 | 0.069 | 0.069 | 0.210 | 151/200 |\n| Shuffle axial (cross-volume) | 0.649 | 0.667 | 0.325 | 0.323 | 0.081 | 22/200 |\n\nEach shuffle collapses on the axis it permuted while staying near-real on the other two, so the measure tracks 3D ordering rather than slice content; paired against their source volumes these controls differ at p ≤ 2×10⁻²³. With 200 volumes per group a few thousandths reaches nominal significance, so we report distance from real in real-data SDs: every generator is within ±2 SD on inter-slice consistency, and on symmetry LiFT-U is +0.03 SD from real. These coarse mask-based measures do not establish anatomical equivalence, tumour validity, or clinical utility. The cross-volume control segmented in only 22 of 200 cases, so its row reflects a subset selected for being brain-like.\n\n**Comparison with 2D-lifting methods.** The distinction is where cross-slice computation lives. Make-A-Volume inserts volumetric layers — 1D convolutions along the slice axis — into the latent-diffusion U-Net, so slices interact at every denoising step; TCAM-Diff makes the triplane the generative representation itself, decoding every voxel from three orthogonal feature planes with diffusion operating on those planes. Both place 3D capacity inside the generative path. LiFT does not: LiFT-U leaves the frozen 2D generator unchanged, and LiFT-C preserves the 2D encoder, decoder and skip pathways while restricting cross-slice interaction to a bottleneck context module. The 3D capacity is factored out of the synthesis path rather than embedded in it, and is small relative to the synthesis network.\n\nEmpirically, we measured Make-A-Volume's inference cost under our matched setup: 192.9 s per volume and 423.2 M parameters, against 1.159 s and 41.3 M for LiFT-C. On quality, Make-A-Volume finished training to convergence on the t2f target since our previous comment. It was evaluated on the same 219 held-out subjects, at the same native 240×240×155 resolution, under the same intensity normalisation and with the same metric code as every other method in the tables above. LiFT-C reaches 28.02 dB PSNR and 0.9430 SSIM against 23.62 dB and 0.9249, paired by subject, with LiFT-C ahead in 200 of 219 on PSNR and 215 of 219 on SSIM (p ≤ 10⁻³²). Make-A-Volume synthesises at 256² and its volumes were resampled to the evaluation grid; scoring both methods at 256² instead gives the same conclusion (a 4.7 dB gap). This covers one of the four missing-MR targets, so it is not yet the matched four-contrast comparison the tables above report.\n\nThese results address the four points in the follow-up: the figures and the implementation details, the statistical strength of the coherence evaluation, and its comparison against published methods rather than our own ablation alone. The matched 2D-lifting quality comparison remains partial at one of four targets, and we will complete it in the revised manuscript. We are grateful for the specificity of this review, which has improved both the evidence and how it is presented."
+ },
+ "createdAt": "2026-08-04T07:11:07.016Z",
+ "modifiedAt": "2026-11-19T16:46:16.858Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=JOH7FsPZmx",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sfz1prmige/notes/pzxapyb4jj.json added

+++ b/reviews/openreview/sfz1prmige/notes/pzxapyb4jj.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "pZxApyb4jj",
+ "replyTo": "8ecLzoUj1r",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response 1/3",
+ "comment": "Thank you for raising your score and for identifying precisely what remains. Below, we present the analyses completed since our last response.\n\n**Figures and manuscript.** We sincerely appreciate the reviewer identifying these presentation issues. We have revised both figures rather than correcting them element by element: a consistent visual language across both figures, every symbol checked against the equations, and text rendered as text rather than as an image. The discussion period does not permit uploading a revised PDF, so we describe the changes here. In the revision, Figure 2 no longer carries the legend strip that produced the duplicated \"local mean\" entries; the panel labels the projection operators explicitly as π_xy (axial), π_yz (sagittal) and π_xz (coronal), names the generated feature banks, and every remaining marker corresponds to one of the three quantities in Eq. (4) — the generated feature g, the real feature bank {r_k}, and the kernel-weighted local target μ. Figure 1 is labelled a conceptual overview and split into two implementation diagrams, one for LiFT-U and one for LiFT-C, so the shared principle and the task-specific realizations are no longer combined in a single panel. The related-work and motivation sections state the factorization question directly, and the mapper architecture, depth encoding, conditioning interface and context-merge layer are specified in the method section and appendix. On the qualitative side, Appendix Figure 4 already shows the missing-MR case in axial, coronal and sagittal reformats, with the no-mapper ablation alongside the full model and per-method error maps over the same volume; the revision promotes that comparison into the main text and frames it explicitly as through-plane evidence rather than general qualitative results. These changes are incorporated in our working revision and will appear in the revised manuscript.\n\n**Paired upper confidence bounds against cWDM.** Matching LiFT-C and cWDM subject by subject across all 219 held-out cases, the one-sided 95% upper confidence bound on cWDM's advantage is 0.10 dB for average PSNR and 0.0002 for average SSIM, and the observed average SSIM difference in fact favours LiFT-C. Per-subject correlations are 0.80–0.97, so the paired analysis removes much of the between-patient variation. We report confidence bounds rather than testing against a fixed margin because no standard non-inferiority margin exists for this task; a bound of 0.10 dB is a stronger statement than a non-significant test, since it limits how large the difference could be rather than only failing to detect one.\n\n**Matched recent baselines.** These evaluations use the same held-out subjects with identical preprocessing and metric code, and for unconditional generation all models were trained on the same BraTS T1n split. The FID values differ from our preliminary response because every method was reevaluated against the same 219-subject real reference used for the real-versus-real calibration.\n\n| Model | FID ×10³ | Time/volume | Parameters |\n| :------------------------ | ---------: | ----------: | ---------: |\n| Real held-out calibration | 0.056 | — | — |\n| LiFT-U | 0.086 | 0.039 s | 30.3 M |\n| 3D MedDiffusion | 0.085 | 15.37 s | 166.3 M |\n| MAISI-v2 | 0.279 | 0.506 s | 201.4 M |\n\nLiFT-U and 3D MedDiffusion reach essentially the same FID, against a real-versus-real calibration floor of 0.056. For missing-MR, on all 219 subjects and all four targets:\n\n| Model | Avg. PSNR | Avg. SSIM | Time/volume | Parameters | Steps |\n| :-------- | --------: | --------: | ----------: | ---------: | ----: |\n| LiFT-C | 28.417 | 0.9528 | 1.159 s | 41.3 M | 1 |\n| cWDM | 28.425 | 0.9525 | 156.4 s | 81.5 M | 1000 |\n| Fast-cWDM | 28.233 | 0.9456 | 15.53 s | 81.5 M | 100 |\n\nLiFT-C is within 0.008 dB of cWDM on average PSNR and slightly ahead on average SSIM at 135× the speed, and improves on Fast-cWDM by 0.184 dB and 0.0072 SSIM at 13.4× the speed with about half the parameters."
+ },
+ "createdAt": "2026-08-04T07:10:14.390Z",
+ "modifiedAt": "2026-11-19T16:46:16.862Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=pZxApyb4jj",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sfz1prmige/notes/vqcvw1cvr4.json added

+++ b/reviews/openreview/sfz1prmige/notes/vqcvw1cvr4.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "VqCVW1CVR4",
+ "replyTo": "Hhp4SjmdMS",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response 1/4",
+ "comment": "Thank you for the follow-up and for identifying the additional details needed to assess the new results. Below, we present the results and analyses completed since our previous response to address the remaining concerns.\n\n\n**Recent-baseline protocol and completed results.** Models compared below were trained on the same BraTS T1n training split at (128^3); the 219 held-out subjects were used only for final evaluation. All unconditional models were evaluated against the same held-out real reference using identical MedicalNet feature extraction and metric code. MAISI-v2 and 3D MedDiffusion were retrained on this split rather than used off-the-shelf; for MAISI-v2 we ran both from-scratch and warm-started training and report the better of the two.\n\n| Model | FID ×10³ | Recall | Precision | Coverage | Time/volume | Parameters |\n| :------------------------ | ---------: | ------------: | ----------: | ---------: | ------------: | ---------: |\n| Real held-out calibration | 0.056 | 0.890 | 0.904 | 0.954 | — | — |\n| LiFT-U | 0.086 | 0.877 ± 0.016 | 0.977 | 0.990 | 0.039 s | 30.3 M |\n| 3D MedDiffusion | 0.085 | 0.861 ± 0.026 | 0.935 | 0.963 | 15.37 s | 166.3 M |\n| MAISI-v2 | 0.279 | 0.616 ± 0.043 | 0.902 | 0.794 | 0.506 s | 201.4 M |\n\nLiFT-U obtains essentially the same FID as 3D MedDiffusion while being approximately 394× faster and using 5.5× fewer parameters. Relative to the real-data calibration, LiFT-U achieves recall 0.877 versus 0.890, precision 0.977 versus 0.904, and coverage 0.990 versus 0.954. The FID values differ from our preliminary response because all methods were reevaluated against the same 219-subject real reference used for the real-versus-real calibration.\n\n**Consolidated design.** The submitted missing-MR model used recurrence over pooled slice descriptors, whereas the MR-to-CT model used a spatial bottleneck map. In analysis performed in response to the lesion-fidelity question, a linear probe showed that the spatial representation preserves within-slice lesion localization (per-pixel tumour-occupancy AUC 0.973). We therefore standardized both tasks on the spatial configuration for the new analyses reported below. This raises the missing-MR average PSNR from 28.31 dB for the submitted pooled configuration to 28.42 dB for the spatial configuration, while leaving the quality–efficiency conclusion unchanged.\n\nWe also completed our matched Fast-cWDM evaluation on all 219 held-out subjects and all four missing-MR targets. All methods use identical preprocessing and metric code.\n\n| Model | Avg. PSNR | Avg. SSIM | Time/volume | Parameters | Steps |\n| :-------- | ----------: | ----------: | ------------: | ---------: | ----: |\n| LiFT-C | 28.417 | 0.9528 | 1.159 s | 41.3 M | 1 |\n| cWDM | 28.425 | 0.9525 | 156.4 s | 81.5 M | 1000 |\n| Fast-cWDM | 28.233 | 0.9456 | 15.53 s | 81.5 M | 100 |\n\nLiFT-C differs from cWDM by 0.008 dB in average PSNR, slightly exceeds it in average SSIM, and is 135× faster. Compared with Fast-cWDM, LiFT-C improves average PSNR by 0.184 dB and SSIM by 0.0072 while being 13.4× faster and using about half the parameters. Fast-cWDM trains and samples with 100 rather than 1000 steps while retaining the same 81.5 M-parameter network, whereas LiFT-C synthesizes the volume in a single pass. The reconstruction-quality differences between LiFT-C and cWDM are small. Our claim is that LiFT achieves competitive quality with substantially lower computational cost, not that it is superior on every reconstruction metric."
+ },
+ "createdAt": "2026-08-03T21:58:24.152Z",
+ "modifiedAt": "2026-11-19T16:46:16.974Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=VqCVW1CVR4",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sfz1prmige/notes/xjidafhunt.json added

+++ b/reviews/openreview/sfz1prmige/notes/xjidafhunt.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "XJIdAFHUnT",
+ "replyTo": "pZxApyb4jj",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response 2/3",
+ "comment": "**Statistical analysis of the coherence results.** All measures are computed per subject and paired across the 219-subject validation set, with bootstrap 95% confidence intervals (10,000 resamples) and paired Wilcoxon tests.\n\n| Coherence metric (lower = better) | Improvement over no-mapper | 95% CI | p | Subjects improved |\n| :-------------------------------- | -------------------------: | :------------------- | ---------: | ----------------: |\n| Axial-bias SSIM gap | +0.00036 | [+0.00033, +0.00040] | 3.5×10⁻³⁶ | 206 / 219 |\n| Normalized adjacent-slice error | +0.01120 | [+0.00908, +0.01361] | 2.2×10⁻²⁹ | 190 / 219 |\n| Absolute adjacent-slice error | +0.00006 | [+0.00005, +0.00006] | 3.5×10⁻³⁰ | 194 / 219 |\n\nAll twelve per-contrast cells (four contrasts × three metrics) are significant in the same direction and remain so after Bonferroni correction. Every confidence interval excludes zero. The axial-bias gap, the measure most directly sensitive to slice-stacking, narrows by 13% relative to the no-mapper control.\n\n**Coherence against published methods.** The comparison above is against our own ablation. Scoring published methods with the same code on the same 219 subjects places LiFT-C as follows.\n\n| Model | Normalized adj-slice error ↓ | Absolute adj-slice error ↓ |\n| :-------- | ---------------------------: | -------------------------: |\n| cWDM | 0.56933 | 0.00376 |\n| LiFT-C | 0.60147 | 0.00393 |\n| Fast-cWDM | 0.61268 | 0.00400 |\n| pix2pix | 0.73038 | 0.00468 |\n\nTests average the four contrasts within each subject and are paired across the 219 subjects. LiFT-C improves on pix2pix in every subject (p < 10⁻³⁶) and on Fast-cWDM by a smaller margin (p = 0.037 and 0.003), while 1000-step cWDM is better than LiFT-C on both measures at 135× the inference cost. The axial-bias gap is reported for the ablation, where the two models reconstruct at matched quality; it is not comparable across models at different quality levels, since a uniformly weaker model exhibits little anisotropy."
+ },
+ "createdAt": "2026-08-04T07:10:40.448Z",
+ "modifiedAt": "2026-11-19T16:46:16.902Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=XJIdAFHUnT",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sfz1prmige/notes/xki2rnkby6.json added

+++ b/reviews/openreview/sfz1prmige/notes/xki2rnkby6.json
@@ -0,0 +1,15 @@
+{
+ "schema": "review/1",
+ "id": "xki2RnKby6",
+ "replyTo": "Hhp4SjmdMS",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Reviewer kg5B",
+ "content": {
+ "comment": "Thank you for the response, it clarifies that the intended claim is a quality-efficiency trade-off rather than universal SOTA, and provides clarifications on architectural distinctions from Make-A-Volume. The new benchmarks are potentially important, but hard to judge without more details, e.g. whether MAISI-v2 was tuned on BraTS T1n etc, and some SOTA comparisons remain in progress. The new SynthRad results are also interesting and while numerically true that LiFT-C seem to have the highest scores, the differences are small enough that it could be well within the variance. Also these rebuttal numbers differ substantially from Table 6. Finally, the response acknowledges that FID is insufficient for anatomical validity but provides no new unconditional anatomy/pathology-aware metrics or real-vs-real calibration. I therefore view the rebuttal positively but retain my overall rating of 3, while increasing my assessment of the potential significance of the efficiency result."
+ },
+ "createdAt": "2026-08-03T09:20:33.289Z",
+ "modifiedAt": "2026-11-19T16:46:17.002Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=xki2RnKby6",
+ "license": "CC-BY-4.0"
+}

reviews/openreview/sfz1prmige/notes/yl68ekrcnv.json added

+++ b/reviews/openreview/sfz1prmige/notes/yl68ekrcnv.json
@@ -0,0 +1,16 @@
+{
+ "schema": "review/1",
+ "id": "Yl68EKRCNV",
+ "replyTo": "VqCVW1CVR4",
+ "kind": "comment",
+ "invitation": "Official_Comment",
+ "signature": "Authors",
+ "content": {
+ "title": "Response 2/4",
+ "comment": "**Statistical significance of the differences.** As the reviewer notes, a non-significant difference is not evidence of equivalence. For missing-MR we therefore report how large the difference could be, rather than whether a test rejects it; for MR-to-CT, where the reviewer asks whether the differences lie within the variance, we report paired significance directly.\n\nMissing-MR. Matching LiFT-C and cWDM subject by subject across all 219 cases, the one-sided 95% upper confidence bound on cWDM's advantage is 0.10 dB for average PSNR and 0.0002 for average SSIM; the observed average SSIM difference in fact favours LiFT-C. The largest per-contrast bounds are 0.43 dB for t1n PSNR and 0.0016 for t2f SSIM. The two models score the same patients similarly, with per-subject correlations of 0.80–0.97, so the paired analysis removes much of the between-patient variation. We use confidence bounds rather than testing against a fixed non-inferiority margin because no standard margin exists for this task.\n\nMR-to-CT. Across the 36 paired test patients, LiFT-C has lower MAE than the strongest baseline, Pix2pix-ResNet, in 29 of 36 cases with a median improvement of 2.95 HU (paired Wilcoxon p = 0.013), and higher SSIM in 31 of 36 (median +0.008, p = 5×10⁻⁵); PSNR favours LiFT-C in 27 of 36 patients but does not reach two-sided significance (p = 0.054). Against the no-mapper control all three metrics improve at p = 3×10⁻¹¹. The statistically supported gains over Pix2pix-ResNet are in MAE and SSIM; the PSNR difference is inconclusive at the 0.05 threshold. On the difference from Table 6: the rebuttal values were recomputed using the official SynthRAD image-metric implementation, including evaluation within the body mask specified by the challenge, whereas Table 6 predates this analysis and used our original evaluation code adapted from CBAM3D-UNet. The baselines, prediction volumes, and 36 held-out patients are identical; only the metric implementation changed, and Table 6 has been updated accordingly in the revised manuscript."
+ },
+ "createdAt": "2026-08-03T21:59:34.229Z",
+ "modifiedAt": "2026-11-19T16:46:17.197Z",
+ "url": "https://openreview.net/forum?id=sFZ1pRmigE&noteId=Yl68EKRCNV",
+ "license": "CC-BY-4.0"
+}