Multi-Level Alignment Framework for Long-Term Olfactory Neural Decoding
Update NeurIPS 2026 submission 7mDyFYDgoM: 20 notes
@openreview[bot] · 2026-11-24 15:46 UTC · bc8bbfb132d9 ·
reviews/openreview/7mdyfydgom/notes/2niwhnghfg.json added
+++ b/reviews/openreview/7mdyfydgom/notes/2niwhnghfg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "2NIwHnghfG",+ "replyTo": "HRhJKF6lVM",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q2: Temporal Shift Augmentation\n\n**Author Response:**\nWe appreciate the reviewer's insightful question regarding the biological validity of the temporal shift augmentation. In fact, this mechanism was explicitly designed to help the model exploit true respiration phase-locked information while discarding arbitrary experimental timing artifacts.\n\nIn free-breathing rodents, the absolute timing of the odor valve opening varies randomly relative to the animal's ongoing respiratory phase. Consequently, the *absolute* temporal latency of odor-evoked spikes (relative to trial onset) fluctuates across trials of the exact same odor. The model must learn the invariant *relative* sequence of neuronal activations within a respiratory cycle, rather than their absolute timing relative to the arbitrary valve trigger. Our stochastic temporal shift ($\\pm 200$ ms) shifts the *entire* population firing matrix simultaneously (Equation 2 in Section 3.2).Therefore, the internal temporal structure and relative phase-locking relationships between all neurons within a trial are perfectly preserved, effectively preventing the model from overfitting to the biologically irrelevant absolute phase.\n\nThe $\\pm 200$ ms magnitude was chosen because it roughly corresponds to one complete basal respiratory cycle of a mouse ($\\sim$5 Hz). To quantitatively validate this parameter, we conducted the suggested ablation study varying the shift magnitude:\n\n| Shift Magnitude | Accuracy | Precision | F1-Score |\n| :-------------- | :-------------- | :-------------- | :-------------- |\n| 0 ms | 80.93% ± 15.45% | 81.22% ± 15.97% | 80.44% ± 15.94% |\n| 50 ms | 81.34% ± 16.27% | 81.77% ± 16.49% | 80.90% ± 16.65% |\n| 100 ms | 82.49% ± 16.36% | 82.82% ± 16.82% | 82.00% ± 16.86% |\n| 200 ms | 83.67% ± 16.44% | 83.86% ± 16.83% | 82.98% ± 17.02% |\n| 300 ms | 83.43% ± 16.23% | 83.71% ± 16.62% | 82.91% ± 16.78% |\n\nAs shown, performance improves as the shift increases, plateauing around our selected 200 ms mark. This confirms that an insufficient shift fails to decouple the neural code from the absolute onset artifact, whereas a full respiratory cycle shift optimally forces the model to rely on robust relative temporal dynamics. We will incorporate this biological justification and ablation table into the revised Appendix."+ },+ "createdAt": "2026-07-30T12:35:41.297Z",+ "modifiedAt": "2026-11-19T17:15:54.896Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=2NIwHnghfG",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/5t4bnbgpus.json added
+++ b/reviews/openreview/7mdyfydgom/notes/5t4bnbgpus.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "5t4BNBGPUs",+ "replyTo": "HRhJKF6lVM",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q3: Severe Signal Degradation\n\n**Author Response:**\nWe are grateful to the reviewer for raising this highly practical consideration regarding late-stage chronic interface degradation. To quantitatively explore LNDN's robustness boundaries and address your question about physical layer input fidelity, we conducted a comprehensive Signal-to-Noise Ratio (SNR) stress test.\n\nUsing the pre-trained LNDN model (trained strictly on clean data from Weeks 1-4), we artificially injected varying levels of additive Gaussian white noise to the spike waveforms ($W$), applied spatial jitter to the neuron positions ($P$), and degraded the firing activity matrices ($X$) during inference on the completely unseen future sessions (Weeks 5-12).\n\n| Configuration | Waveform SNR | Position Jitter | Activity SNR | Accuracy | $\\Delta$ Accuracy |\n| :-------------------- | :----------- | :-------------- | :----------- | :-------------- | :---------------- |\n| Clean (Baseline) | - | - | - | 83.67% ± 16.44% | 0.00% |\n| W + P Degraded | 20 dB | 5 $\\mu$m | - | 69.78% ± 17.43% | -13.89% |\n| W + P Degraded | 10 dB | 10 $\\mu$m | - | 67.79% ± 17.72% | -15.88% |\n| W + P Degraded | 5 dB | 20 $\\mu$m | - | 66.22% ± 17.77% | -17.45% |\n| W + P Degraded | 0 dB | 40 $\\mu$m | - | 64.48% ± 17.66% | -19.19% |\n| W + P Degraded | -5 dB | 80 $\\mu$m | - | 62.88% ± 17.76% | -20.79% |\n| X (Activity) Degraded | - | - | 10 dB | 82.18% ± 16.53% | -1.49% |\n| X (Activity) Degraded | - | - | 0 dB | 78.06% ± 16.63% | -5.61% |\n| All Degraded | 10 dB | 10 $\\mu$m | 10 dB | 65.02% ± 17.14% | -18.65% |\n| All Degraded | 0 dB | 20 $\\mu$m | 0 dB | 56.80% ± 15.29% | -26.87% |\n\nThe results show a sharp initial drop in decoding accuracy when noise is introduced to the waveform and position features; however, the subsequent rate of degradation slows down significantly as noise levels increase further. Notably, the model exhibits high robustness when noise is applied exclusively to the firing activity, maintaining an accuracy of 78.06% even at an extreme 0 dB SNR. Severe performance degradation occurs primarily when extreme noise is simultaneously applied across all three modalities (\"All Degraded\"). Furthermore, a cross-comparison between the 'W+P Degraded' and 'All Degraded' conditions under identical noise levels (67.79% vs. 65.02% at 10 dB; 64.48% vs. 56.80% at 0 dB) demonstrates that when only the physical layer's neuron identity fidelity decreases, the firing activity features exhibit a degree of compensatory resilience against interference."+ },+ "createdAt": "2026-07-30T12:34:02.830Z",+ "modifiedAt": "2026-11-19T17:15:54.945Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=5t4BNBGPUs",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/6wcxdgbwkj.json added
+++ b/reviews/openreview/7mdyfydgom/notes/6wcxdgbwkj.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "6wCXDgBwKJ",+ "replyTo": "Tu9fmwm9Wz",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Concern (1): Outdated baselines and lack of recent SOTA comparisons.\n\nWe sincerely thank the reviewer for this constructive and valuable comment. This concern is also shared by Reviewer hxAG, and we have therefore supplemented state-of-the-art models from the past five years that are highly relevant to the field. In the revised manuscript, we have added several highly relevant representative baseline methods from recent years, covering the few-shot decoding and unsupervised domain adaptation tracks that are most comparable to our work. The newly added baselines are detailed as follows:\n\n- **amLDS (NeurIPS 2021)**: A few-shot cross-animal manifold alignment model designed for olfactory neural decoding, which achieves cross-session representation alignment via an aligned mixture of latent dynamical systems.\n- **CAPTIVATE (PMLR 2023)**: A representative zero-target unsupervised domain adaptation method in the brain-computer interface field, which learns domain-invariant neural representations in a self-supervised manner without target labels.\n- **SPINT (NeurIPS 2025)**: A cutting-edge few-shot decoding method for motor BCIs, which incorporates structured inductive bias to enable efficient adaptation across subjects with limited labeled data.\n- **POYO (NeurIPS 2023)** and **CEBRA (Nature 2023)** :the recent strong baseline models included in our original manuscript.\n\nBelow we present the comparison results between our method and representative SOTA baselines in the relevant field over the past five years.\n\n| Model | Pub Year | Accuracy (Mean $\\pm$ SD) | Precision (Mean $\\pm$ SD) | F1-Score (Mean $\\pm$ SD) |\n| :------------------- | :----------- | :----------------------: | :-----------------------: | :----------------------: |\n| **LNDN (Ours)** | / | $0.8367 \\pm 0.1644$ | $0.8386 \\pm 0.1683$ | $0.8298 \\pm 0.1702$ |\n| **CEBRA** | Nature 2023 | $0.7881 \\pm 0.1990$ | $0.8064 \\pm 0.1997$ | $0.7626 \\pm 0.2293$ |\n| **SPINT** | NeurIPS 2025 | $0.6739 \\pm 0.1663$ | $0.7061 \\pm 0.1658$ | $0.6585 \\pm 0.1713$ |\n| **amLDS** | NeurIPS 2021 | $0.6514 \\pm 0.2080$ | $0.6811 \\pm 0.2373$ | $0.6110 \\pm 0.2374$ |\n| **CAPTIVATE** | PMLR 2023 | $0.5386 \\pm 0.1548$ | $0.5590 \\pm 0.1807$ | $0.5085 \\pm 0.1682$ |\n| **POYO(Scratch)** | NeurIPS 2023 | $0.5089 \\pm 0.1041$ | $0.5296 \\pm 0.1355$ | $0.4820 \\pm 0.1183$ |\n| **POYO(Pretrained)** | NeurIPS 2023 | $0.5046 \\pm 0.1082$ | $0.5138 \\pm 0.1297$ | $0.4702 \\pm 0.1258$ |\n\n\n\n### Response to Concern (2): Unexplained acronyms affecting readability.\n\nWe sincerely apologize for the confusion caused by the undefined acronyms. Since the manuscript cannot be revised during the current rebuttal phase, we commit to refining the presentation and minimizing unnecessary acronyms to the fullest extent possible in the revised version."+ },+ "createdAt": "2026-08-04T09:33:44.929Z",+ "modifiedAt": "2026-11-19T17:15:54.465Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=6wCXDgBwKJ",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/82eicvylx8.json added
+++ b/reviews/openreview/7mdyfydgom/notes/82eicvylx8.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "82eIcVylx8",+ "replyTo": "OCdyh6YXMQ",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Thank you very much for reviewing our rebuttal and for your positive feedback. We are glad to hear that our additional data and explanations have successfully addressed your initial concerns.\n\nWe will strictly ensure that all the new efficiency metrics, ablation tables, and detailed biological explanations provided during the rebuttal phase are comprehensively incorporated into the revised Appendix, exactly as indicated.\n\nFurthermore, to provide a more intuitive understanding of the robustness boundaries discussed in our \"Response to Q3: Severe Signal Degradation\", we will visually present the waveform and position noise degradation settings as a figure (with detailed legends) in the revised manuscript.\n\nThank you again for your constructive guidance, which has greatly helped us improve the quality and rigor of our work!"+ },+ "createdAt": "2026-08-02T15:06:36.152Z",+ "modifiedAt": "2026-11-19T17:15:54.642Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=82eIcVylx8",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/bsb4unnc3n.json added
+++ b/reviews/openreview/7mdyfydgom/notes/bsb4unnc3n.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Bsb4uNNC3n",+ "replyTo": "fF3pzS8L1m",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We sincerely thank you for recognizing the importance of our research and for your constructive guidance in the Meta Review. We have now responded to all the preliminary comments raised by the reviewers and provided detailed supplementary experiments and analyses. To address your specific concerns, we provide the following detailed clarifications:\n\n**① \"The paper offers relatively little motivation about why their approach is appropriate.\"**\n\nIn our \"Response to Q3, Q4, Q8: Lack of Theoretical Motivation and Biological Incorporation\" to Reviewer 3gev, we thoroughly clarified how our proposed tri-level alignment strategy maps to and resolves the specific biological challenges inherent in long-term olfactory recordings:\n\n* **Physical Level:** Our design addresses electrode micro-motions and signal amplitude fluctuations induced by respiratory rhythms. Simultaneously, it allows the model to effectively process mixed and unordered neural activity signals across different weeks, thereby enabling an end-to-end decoding pipeline directly from spike sorting outputs without the need for manual alignment or tracking.\n* **Decision Level:** This alignment targets the issues of localized adult neurogenesis and neural signal decay over extended periods. It utilizes parallel expert networks to mitigate the high variance caused by local feature distortions.\n* **Manifold Level:** Regarding the losses at this level, we provided detailed mathematical explanations of how they ensure the formation of an odor-invariant latent manifold space while maintaining separable boundaries between odor categories during the encoding process.\n\n**② \"The reviewers raised several q uestions related to the methodology and comparisons to baselines.\"**\n\n* **Comparison with Domain Baselines:** In our \"Response to Q4, W4: Comparison Experiments with Domain Baselines\" to Reviewer hxAG, we supplemented our evaluation with strong domain-relevant baselines, including amLDS, SPINT, and CAPTIVATE. The results verify the efficacy of our method. \n* **Statistical Significance:** A detailed significance analysis was also presented in \"Response to Q1, W1: Statistical Significance Testing\" for Reviewer hxAG. We employed four statistical significance metrics to demonstrate that our model's performance advantage is statistically significant ($p < 0.05$) alongside reported effect sizes. We also provided a granular comparison of decoding accuracy per mouse and per week. \n* **Ablation Studies:** In response to Reviewer 3gev, we supplemented comprehensive ablation studies, including both \"leave-one-out\" (w/o) and \"add-one-in\" (w/) configurations, thoroughly validating the effectiveness of each individual module within our model.\n\n**③ Fairness of Baseline Settings:**\n\nWe noted that two reviewers raised concerns regarding the baseline configurations. In fact, the chaotic and unordered nature of neural information in cross-session decoding without neuron tracking has always been a critical challenge in the field. Our initial decision to provide baseline models with cross-session tracked and aligned neural data was explicitly intended to allow all comparative models to achieve their optimal performance, preventing them from suffering severe overfitting due to unordered input data. In our \"Response to Q1: Unfair Baseline Comparisons\" to Reviewer 3gev, we comprehensively demonstrated that if tracking is omitted and all baseline models are fed the exact same raw data inputs as LNDN, they suffer from a severe degradation in classification accuracy.\n\n**④ How Our Model Outperforms Current Models:**\n\nBeyond its decoding accuracy, our model possesses several objective structural strengths:\n\n1. **Utilization of Biological Priors:** In the field of Brain-Computer Interface (BCI) decoding, data acquisition in many brain regions is severely constrained by implantation difficulties and biological sensory adaptation limitations, leading to an extreme scarcity of large-scale data. Our design intentionally leverages biological prior constraints (e.g., waveform and position information synchronously output from spike sorting, latent manifold stability) to learn stable and robust classification features under a small-sample regime, rather than relying purely on data-driven generalization.\n2. **Tracking-Free Architecture:** Cross-session data acquisition routinely faces inconsistencies in neuron detection. If unordered cross-week information is not tracked and aligned, it leads to severe model overfitting. However, forced tracking and alignment inevitably result in the loss of valuable input information (as evidenced by the performance drop in the \"LNDN (CU Data)\" group compared to the \"LNDN (Full Data)\" group, detailed in our \"Response to Q3, W3\" to Reviewer hxAG). Therefore, our architecture is specifically designed to directly ingest spike-sorted outputs for end-to-end decoding, preventing data attrition without sacrificing, and indeed enhancing, decoding accuracy."+ },+ "createdAt": "2026-07-31T09:42:45.447Z",+ "modifiedAt": "2026-11-19T17:15:54.660Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=Bsb4uNNC3n",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/ff3pzs8l1m.json modified
+++ b/reviews/openreview/7mdyfydgom/notes/ff3pzs8l1m.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair Ve7M","content": {- "metareview": "**Initial meta-review**\n\nThis paper addresses the problem of designing long-term olfactory bulb neural decoders that do not require realignment.\n\nThe problem is important, yet challenging because biological variability (due to neurogenesis) and measurement variability (due to electrode movement) are entangled. Moreover, there is limited available training data.\n\nThe main strength of the paper is that the method outperforms previous approaches (that were tested).\n\nThe main weaknesses are:\n- The paper offers relatively little motivation about why their approach is appropriate (most of the paper is Methods, Experiments, Results).\n- The reviewers raised several questions related to the methodology and comparisons to baselines.\n\nMy overall impression is that if the method robustly outperforms existing approaches, then that is a meaningful result (though a theoretical understanding of why would be more satisfying). However, the authors need to address the reviewers' concerns about the efficacy of their method.\n\n**Final meta-review**\n\nI have read the authors' rebuttal and the reviewers' responses. The final assessments by the reviewers are mixed. \n\n**Reviewer hxAG** wrote\n> The authors ran every analysis I asked for, including the ones that did not favour them.\n\nThe authors addressed most of their concerns.\n\n**Reviewer TmZf** maintained a positive assessment, but lowered their score from a 5 to a 4, writing\n> The framework primarily assembles existing well-established techniques (lightweight cross-attention, AdaBN, Deep CORAL, and template matching) into a systematic pipeline, rather than introducing a fundamentally novel computational paradigm \n\n**Reviewer 3gev** stated that they still have concerns, writing\n> The manuscript still contains a large number of unexplained acronyms and requires significant changes. This paper should compare the proposed approach with more recent methods that were published in 2026. Due to these reasons, I do not change my score.\n\nFirst, regarding the acronyms, according to the NeurIPS guidelines \"authors may not submit revisions of their paper or supplemental material\", so they are unable to edit the acronyms. Instead, they wrote \"In the revised manuscript, we will expand less common acronyms (e.g., SSHD to \"Small-Sample, High-Dimensional\", OB to \"Olfactory Bulb\") throughout the text to improve readability.\" \n\nSecond, regarding comparing to baselines, the authors added baselines from 2021-2025. In addition, the guidelines state \n>For the purpose of the reviewing process, papers that appeared online after March 1st, 2026 will generally be considered \"contemporaneous\" in the sense that the submission will not be rejected on the basis of the comparison to contemporaneous work. Authors are still expected to cite and discuss contemporaneous work and perform empirical comparisons to the degree feasible.\n\n**Incorrect references**\nThe automated citation checked flagged the following ostensibly hallucinated reference:\n>The title 'Poyo: Spatiotemporal models for objective brain-computer interfaces' does not exist. The actual paper by Mehdi Azabou et al. introducing POYO is titled 'A unified, scalable framework for neural population decoding' (published in NeurIPS 2023, arXiv:2310.16046). Furthermore, the arXiv ID 2311.00423 corresponds to an unrelated paper titled 'LLMRec: Large Language Models with Graph Augmentation for Recommendation'.\n\nThe authors should correct this reference."+ "metareview": "**Initial meta-review**\n\nThis paper addresses the problem of designing long-term olfactory bulb neural decoders that do not require realignment.\n\nThe problem is important, yet challenging because biological variability (due to neurogenesis) and measurement variability (due to electrode movement) are entangled. Moreover, there is limited available training data.\n\nThe main strength of the paper is that the method outperforms previous approaches (that were tested).\n\nThe main weaknesses are:\n- The paper offers relatively little motivation about why their approach is appropriate (most of the paper is Methods, Experiments, Results).\n- The reviewers raised several questions related to the methodology and comparisons to baselines.\n\nMy overall impression is that if the method robustly outperforms existing approaches, then that is a meaningful result (though a theoretical understanding of why would be more satisfying). However, the authors need to address the reviewers' concerns about the efficacy of their method.\n\n**Final meta-review**\n\nI have read the authors' rebuttal and the reviewers' responses. The final assessments by the reviewers are mixed. \n\n**Reviewer hxAG** wrote\n> The authors ran every analysis I asked for, including the ones that did not favour them.\n\nThe authors addressed most of their concerns.\n\n**Reviewer TmZf** maintained a positive assessment, but lowered their score from a 5 to a 4, writing\n> The framework primarily assembles existing well-established techniques (lightweight cross-attention, AdaBN, Deep CORAL, and template matching) into a systematic pipeline, rather than introducing a fundamentally novel computational paradigm \n\n**Reviewer 3gev** stated that they still have concerns, writing\n> The manuscript still contains a large number of unexplained acronyms and requires significant changes. This paper should compare the proposed approach with more recent methods that were published in 2026. Due to these reasons, I do not change my score.\n\nFirst, regarding the acronyms, according to the NeurIPS guidelines \"authors may not submit revisions of their paper or supplemental material\", so they are unable to edit the acronyms. Instead, they wrote \"In the revised manuscript, we will expand less common acronyms (e.g., SSHD to \"Small-Sample, High-Dimensional\", OB to \"Olfactory Bulb\") throughout the text to improve readability.\" \n\nSecond, regarding comparing to baselines, the authors added baselines from 2021-2025. In addition, the guidelines state \n>For the purpose of the reviewing process, papers that appeared online after March 1st, 2026 will generally be considered \"contemporaneous\" in the sense that the submission will not be rejected on the basis of the comparison to contemporaneous work. Authors are still expected to cite and discuss contemporaneous work and perform empirical comparisons to the degree feasible.\n\n**Incorrect references**\nThe automated citation checked flagged the following ostensibly hallucinated reference:\n>The title 'Poyo: Spatiotemporal models for objective brain-computer interfaces' does not exist. The actual paper by Mehdi Azabou et al. introducing POYO is titled 'A unified, scalable framework for neural population decoding' (published in NeurIPS 2023, arXiv:2310.16046). Furthermore, the arXiv ID 2311.00423 corresponds to an unrelated paper titled 'LLMRec: Large Language Models with Graph Augmentation for Recommendation'.\n\nThe authors should correct this reference.",+ "final_justification": "As stated in the meta-review, the final reviews are mixed, with 2 reviewers recommending boderline accept and one reviewer recommending reject (Reviewer 3gev). Reviewer 3gev had 2 main concerns, one of which the authors promised to address and the other which falls outside the NeurIPS guidelines. Therefore, despite the negative review, I am recommending acceptance."},"createdAt": "2026-07-22T16:12:24.172Z",- "modifiedAt": "2026-11-18T15:25:20.871Z",+ "modifiedAt": "2026-11-19T05:03:23.286Z","url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=fF3pzS8L1m","license": "CC-BY-4.0"}
reviews/openreview/7mdyfydgom/notes/gm9ii0jhbu.json added
+++ b/reviews/openreview/7mdyfydgom/notes/gm9ii0jhbu.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "gm9II0Jhbu",+ "replyTo": "lUNzQwPncG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q4、W4: Comparison Experiments with Domain Baselines (amLDS, SPINT, CAPTIVATE)\n\nWe are grateful to the reviewer for highlighting the importance of evaluating LNDN against domain-relevant baselines (amLDS, SPINT, and CAPTIVATE). We have incorporated head-to-head evaluations against these models:\n\n1. **amLDS (Few-Shot Benchmark):** The training pipeline of amLDS is kept identical to that of LNDN. Given the recalibration requirement of amLDS during inference, we perform independent recalibration and testing on a weekly basis, where 10% labeled trials from each target week are adopted for recalibration. The hyperparameters (latent dimension = 8, EM iterations = 10) are selected via training on Weeks 1–3 data and validation on Week 4 data, consistent with our universal hyperparameter screening strategy. For the configuration of EM iterations, we initially followed the original amLDS implementation by setting the convergence tolerance to $10^{-4}$ with a maximum iteration number of 50. Nevertheless, this configuration yielded severely degraded decoding performance (see the amLDS_convergence group in the corresponding table). Accordingly, we treated EM iteration count as a tunable hyperparameter and determined the optimal value of 10 through formal validation screening.\n2. **SPINT (Few-Shot Benchmark):** The original SPINT framework is designed for continuous movement decoding. To adapt it to our discrete odor classification task, we modified the original output heads into scalar logit branches, with each odor category assigned a corresponding learnable query vector. CrossEntropyLoss is utilized as the objective function to fit the discrete classification task, while all remaining network architectures strictly follow the native implementation of SPINT without extra modifications. For fair comparison, we adopt the same weekly calibration strategy as amLDS, using 10% trials(unlabeled) from each target week during the calibration phase.\n3. **CAPTIVATE (Zero-Target Benchmark):** We reproduced CAPTIVATE strictly following the network architecture and training pipeline detailed in its original paper. The backbone of the model consists of a GRU-based neuron locator, a sequential variational autoencoder, and a downstream classifier as proposed in the original work. We adopted the six perturbation types and loss functions specified in the paper throughout training.\n\n| Model | Category / Target Supervision | Accuracy (Mean $\\pm$ SD) | Precision (Mean $\\pm$ SD) | F1-Score (Mean $\\pm$ SD) |\n| :---------------------- | :--------------------------------- | :----------------------: | :-----------------------: | :----------------------: |\n| **LNDN (Ours)** | Transductive Test-Time Adaptation | $0.8367 \\pm 0.1644$ | $0.8386 \\pm 0.1683$ | $0.8298 \\pm 0.1702$ |\n| **SPINT** | Few-Shot (Label-guided) | $0.6739 \\pm 0.1663$ | $0.7061 \\pm 0.1658$ | $0.6585 \\pm 0.1713$ |\n| **amLDS (EM=10)** | Few-Shot (10% Labeled Target Data) | $0.6514 \\pm 0.2080$ | $0.6811 \\pm 0.2373$ | $0.6110 \\pm 0.2374$ |\n| **amLDS (Convergence)** | Few-Shot (10% Labeled Target Data) | $0.3573 \\pm 0.1683$ | $0.2471 \\pm 0.2352$ | $0.2448 \\pm 0.1965$ |\n| **CAPTIVATE** | Zero-Target (Self-Supervised) | $0.5386 \\pm 0.1548$ | $0.5590 \\pm 0.1807$ | $0.5085 \\pm 0.1682$ |\n\nAll quantitative metrics consistently verify the effectiveness of LNDN. We will integrate all the above baseline comparison results(best) into the main text of the revised manuscript.\n\n### Response to Minor Comments: Figure Labeling Clarification and Citation Issue Rectification\n\n**Author Response:**\n\nWe sincerely thank the reviewer for carefully reading the manuscript and pointing out these details.\n\nWe would like to clarify that the notations `(q1/q2/q3)` in Figures 1(c) and 2 were originally intended to denote the dedicated learnable query vectors ($q^{(1)}, q^{(2)}, q^{(3)}$) associated with each respective expert in the Mixture-of-Experts (MoE) cross-attention module (as defined in Section 3.3). Comprehensive checks and revisions will be implemented for all citation concerns addressed in your review comments within the revised manuscript."+ },+ "createdAt": "2026-07-30T13:23:26.501Z",+ "modifiedAt": "2026-11-19T17:15:54.895Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=gm9II0Jhbu",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/l1lrfodhjy.json added
+++ b/reviews/openreview/7mdyfydgom/notes/l1lrfodhjy.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "L1lRFODHjy",+ "replyTo": "Tu9fmwm9Wz",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Concern (3、4): Computational costs and real-time application feasibility.\n\nWe sincerely thank the reviewer for raising the concern regarding computational cost. Reviewer TmZf has also posed a question about the implementation feasibility of our model when deployed on edge hardware. From the initial stage of model design, we have fully considered the demand for real-time decoding, and all components are engineered to minimize computational resource consumption as much as possible. For instance, instead of adopting the standard self-attention mechanism, each expert only employs a single-layer cross-attention mechanism paired with a static 1D learnable query vector. This structural simplification effectively reduces the computational complexity from \\(\\mathcal{O}(N^2 \\cdot d)\\) in standard Transformers to \\(\\mathcal{O}(N \\cdot d)\\).\n\nTo quantitatively address the power consumption concerns, we evaluated the inference Floating Point Operations (FLOPs) and CPU latency per trial for LNDN under varying tracked neuron counts (N). In our dataset, valid neuron counts strictly ranged between 46 and 68 per session:\n\n| Tracked Neurons (N) | Total Parameters | Inference FLOPs | CPU Latency (ms/trial) |\n| ------------------- | ---------------- | --------------- | ---------------------- |\n| 50 | 278,892 | 15.47 M | 2.16 ms |\n| 100 | 278,892 | 30.69 M | 2.17 ms |\n| 200 | 278,892 | 61.13 M | 2.63 ms |\n\nTo assess the deployment constraints raised in your comment, we further provide the parameter sizes of various models:\n\n| Model | Total Parameters(Neurons = 50) |\n| ------------- | -------------------------------- |\n| **LNDN** | 278,892 |\n| **amLDS** | 4,070 |\n| **SPINT** | 639,096 |\n| **POYO** | 1,279,876 |\n| **CEBRA** | 2,061,732 |\n| **CAPTIVATE** | 6,982,454 |\n\nLNDN is lightweight (approximately 280,000 parameters) and computationally efficient, with a per-trial CPU latency of around 2.16 ms, making it highly suitable for real-time deployment on resource-constrained edge devices such as MCUs (e.g., STM32). As a probabilistic graphical model, amLDS has an extremely small parameter count. Its primary computational burden lies in the Expectation–Maximization algorithm during the calibration procedure: training on 12,500 trials takes approximately 58 minutes. In this respect, our method enjoys a significant advantage, as it requires no additional calibration time. We commit to including all the aforementioned metrics for computational efficiency and deployment feasibility in the appendix of the revised manuscript."+ },+ "createdAt": "2026-08-04T09:34:23.496Z",+ "modifiedAt": "2026-11-19T17:15:54.469Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=L1lRFODHjy",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/nnu0xpyhpe.json added
+++ b/reviews/openreview/7mdyfydgom/notes/nnu0xpyhpe.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "NnU0XPYHpe",+ "replyTo": "yt2Eob759U",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q5、Q7: Incomplete Ablation Study\n\n**Author Response:**\nThank you for pointing this out. To provide deeper insights into individual component contributions, we conducted both \"Leave-One-Out\" (w/o) ablations from the full LNDN and \"Add-One-In\"(w/) ablations starting from the baseline.\n\n| Model Variant | Accuracy | Precision | F1-Score |\n| :--------------------- | :------------------ | :------------------ | :------------------ |\n| **LNDN (Full)** | **0.8367 ± 0.1644** | **0.8386 ± 0.1683** | **0.8298 ± 0.1702** |\n| w/o Block 1 (Physical) | 0.7509 ± 0.1948 | 0.7573 ± 0.1948 | 0.7455 ± 0.1972 |\n| w/o Block 2 (MoE) | 0.8184 ± 0.1733 | 0.8236 ± 0.1761 | 0.8142 ± 0.1778 |\n| w/o Block 3 (Manifold) | 0.7901 ± 0.1798 | 0.8038 ± 0.1854 | 0.7734 ± 0.1992 |\n| w/o Spatial Dropout | 0.8319 ± 0.1701 | 0.8374 ± 0.1711 | 0.8270 ± 0.1756 |\n| w/o Temporal Shift | 0.8093 ± 0.1545 | 0.8122 ± 0.1597 | 0.8044 ± 0.1594 |\n\n| Model Variant | Accuracy | Precision | F1-Score |\n| :----------------- | :------------------ | :------------------ | :------------------ |\n| **Baseline (MLP)** | **0.5924 ± 0.2016** | **0.5938 ± 0.2139** | **0.5785 ± 0.2067** |\n| w/ Block 1 | 0.7682 ± 0.1634 | 0.7710 ± 0.1697 | 0.7632 ± 0.1680 |\n| w/ Block 2 | 0.6385 ± 0.1681 | 0.6677 ± 0.1753 | 0.6223 ± 0.1798 |\n| w/ Block 3 | 0.6109 ± 0.1696 | 0.6313 ± 0.1802 | 0.5970 ± 0.1742 |\n| w/ Spatial Dropout | 0.6277 ± 0.1656 | 0.6527 ± 0.1690 | 0.6144 ± 0.1728 |\n| w/ Temporal Shift | 0.6795 ± 0.1832 | 0.7028 ± 0.1962 | 0.6592 ± 0.1982 |\n\nThese tables clearly isolate the impact of each module. Notably, Block 1 provides the largest independent boost (from 59.24% to 76.82%), confirming that decoupling physical identity from transient state is the most critical step for combating representational drift. We will replace the cumulative ablation table with these comprehensive results in the revision.\n\n---\n\n### Response to Q6: Heavy Use of Acronyms\n\n**Author Response:**\nWe apologize for the readability issues caused by excessive acronyms. While all acronyms were defined upon their first use, we agree this creates a dense reading experience. In the revised manuscript, we will expand less common acronyms (e.g., SSHD to \"Small-Sample, High-Dimensional\", OB to \"Olfactory Bulb\") throughout the text to improve readability."+ },+ "createdAt": "2026-07-30T12:33:05.744Z",+ "modifiedAt": "2026-11-19T17:15:54.949Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=NnU0XPYHpe",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/ny5wjprhho.json added
+++ b/reviews/openreview/7mdyfydgom/notes/ny5wjprhho.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "Ny5wjPRhhO",+ "replyTo": "yt2Eob759U",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q2: Limited Experimental Setup\n\n**Author Response:**\nWe understand the reviewer's perspective regarding dataset scale from a general ML standpoint. However, we wish to clarify the unique difficulty and extreme scarcity of longitudinal invasive recordings:\n\n1. **Task Difficulty:** While a static 4-class decoding task is trivial on a single day, maintaining stability over 12 weeks under severe neural drift is an unsolved challenge. As shown in our Figure 3, the initial neural code completely decorrelates by week 8. Prior studies (e.g., Schoonover et al., Nature 2021) report that static decoders drop to chance levels after just 32 days.\n2. **Dataset Scale:** In chronic olfactory electrophysiology, tracking 9 mice for 12 weeks represents an exceptionally rare and challenging longitudinal dataset in the field. The vast majority of existing studies in this domain typically track only 4 to 8 animals over 2 to 6 weeks. For instance, *Schoonover et al.* (Nature 2021) investigated long-term olfactory representational drift using 6 mice over 32 days (3 with 8 odors and 3 with 4 odors), while *Herrero-Vidal et al.* (NeurIPS 2021) focused on olfactory decoding across 5 animals without longitudinal tracking. Therefore, our dataset of 9 mice across 12 weeks provides an exceptionally demanding benchmark environment along the temporal dimension. Furthermore, the constraint of 40 trials per session is directly mandated by biological sensory adaptation in the olfactory system. Excessive odor trials within a single session induce severe olfactory bulb neuron desensitization, introducing non-task-related response decay—which is precisely why single-session trial counts remain naturally limited in olfactory electrophysiology literature.\n3. **Diversity vs. Focus:** Olfactory BCIs hold immense practical value, especially given the current lack of effective artificial chemical sensors. However, olfactory decoding faces strict physiological constraints: due to rapid sensory adaptation, animals cannot be continuously exposed to odor stimuli without inducing neural desensitization. Furthermore, chronic electrode implantation in the Olfactory Bulb is exceptionally challenging anatomically, resulting in an extreme scarcity of publicly available chronic electrophysiological datasets. Unlike motor BCIs, olfactory BCIs currently lack the large-scale, long-term public datasets required to pre-train generalized neural foundation models. We deliberately focused on odor decoding precisely to address this sensory BCI bottleneck marked by the coexistence of data scarcity and severe long-term representational drift, thereby providing a targeted, domain-specific solution."+ },+ "createdAt": "2026-07-30T12:12:55.982Z",+ "modifiedAt": "2026-11-19T17:15:54.974Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=Ny5wjPRhhO",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/ocdyh6yxmq.json added
+++ b/reviews/openreview/7mdyfydgom/notes/ocdyh6yxmq.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "OCdyh6YXMQ",+ "replyTo": "HRhJKF6lVM",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer TmZf",+ "content": {+ "comment": "Thank you for the rebuttal. The provided data and explanations address my initial concerns. Please ensure these new metrics, ablation tables, and explanations are included in the revised Appendix as indicated. I have no further questions."+ },+ "createdAt": "2026-08-01T12:34:45.053Z",+ "modifiedAt": "2026-11-19T17:15:54.655Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=OCdyh6YXMQ",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/ok5edpcqhc.json added
+++ b/reviews/openreview/7mdyfydgom/notes/ok5edpcqhc.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "ok5EdPcqhC",+ "replyTo": "lUNzQwPncG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q3、W3: Input Modality Ablation and Baseline Configuration Fairness\n\nWe thank the reviewer for the comments on input fairness. Regarding the discrepancy raised in Weakness (iii): the \"MLP (base)\" ablation condition achieves an accuracy of 59.24%, while the static baselines reach 67–77%. This gap is primarily attributed to the fact that the MLP (base) ablation experiment employs the same neural activity data as LNDN, without any cross-session neuronal tracking or alignment.\n\nWithout cross-session neuronal tracking and alignment, baseline models suffer from severe overfitting when fed with mixed and unordered neural activity signals. Our model is specifically designed to address this limitation: it leverages neuronal identity information output from spike sorting to enable decoding from neuronal populations of arbitrary size and ordering.\n\n(a) To further address your question and verify whether LNDN’s superior performance stems from access to additional input information, we have supplemented the following comparison groups:\n\n1. **Baselines (Full Data):** All baselines (except POYO) use the same input as LNDN: firing matrices are zero-padded to capacity, with waveform and position vectors prepended to prevent temporal model (e.g., RNN/LSTM) hidden state collapse. Since native POYO requires continuous spike tokens and cannot accommodate auxiliary physical features, it is evaluated on its native raw spike tokens for comparison.\n2. **LNDN (CU Data):** LNDN restricted to Common Units, utilizing both activity and physical features.\n3. **LNDN (CU Activity Only):** LNDN restricted strictly to Common Unit firing rates (identical input to standard baselines).\n\n| Model Variant | Accuracy (Mean $\\pm$ SD) | Precision (Mean $\\pm$ SD) | F1-Score (Mean $\\pm$ SD) |\n| :-------------------------- | :----------------------: | :-----------------------: | :----------------------: |\n| **LNDN (Full Data)** | $0.8367 \\pm 0.1644$ | $0.8386 \\pm 0.1683$ | $0.8298 \\pm 0.1702$ |\n| **SVM (Full Data)** | $0.4625 \\pm 0.0961$ | $0.4248 \\pm 0.1570$ | $0.3803 \\pm 0.1152$ |\n| **CEBRA (Full Data)** | $0.4412 \\pm 0.1092$ | $0.3994 \\pm 0.1365$ | $0.3596 \\pm 0.1216$ |\n| **LDA (Full Data)** | $0.4258 \\pm 0.0871$ | $0.4180 \\pm 0.1060$ | $0.3498 \\pm 0.0949$ |\n| **RF (Full Data)** | $0.4248 \\pm 0.0740$ | $0.4311 \\pm 0.1051$ | $0.3677 \\pm 0.0888$ |\n| **XGBoost (Full Data)** | $0.3878 \\pm 0.0698$ | $0.3728 \\pm 0.1246$ | $0.3218 \\pm 0.0916$ |\n| **LSTM (Full Data)** | $0.3564 \\pm 0.0852$ | $0.3100 \\pm 0.1077$ | $0.2755 \\pm 0.0914$ |\n| **Transformer (Full Data)** | $0.3431 \\pm 0.0663$ | $0.2471 \\pm 0.0736$ | $0.2387 \\pm 0.0654$ |\n| **RNN (Full Data)** | $0.3200 \\pm 0.0677$ | $0.2615 \\pm 0.0886$ | $0.2339 \\pm 0.0675$ |\n| **POYO(Scratch)** | $0.5089 \\pm 0.1041$ | $0.5296 \\pm 0.1355$ | $0.4820 \\pm 0.1183$ |\n| **POYO(Pretrained)** | $0.5046 \\pm 0.1082$ | $0.5138 \\pm 0.1297$ | $0.4702 \\pm 0.1258$ |\n| **LNDN (CU Data)** | $0.8256 \\pm 0.1692$ | $0.8300 \\pm 0.1717$ | $0.8214 \\pm 0.1740$ |\n| **LNDN (CU Activity Only)** | $0.7554 \\pm 0.2077$ | $0.7560 \\pm 0.2120$ | $0.7484 \\pm 0.2119$ |\n\n\tThe results demonstrate that standard baselines suffer severe performance degradation (falling below 50%) when exposed to the raw, un-tracked cross-week data due to severe noise overfitting. For this reason, we utilize cross-week aligned neurons specifically to ensure baseline models can be fairly compared against our method at their best achievable performance. \n\n(b) We apologize for the insufficient clarity in our manuscript regarding the input data configuration for POYO. In fact, we evaluated POYO strictly using its native spike tokenization setup. We attribute the underperformance of POYO primarily to the limited scale of the olfactory dataset. Converting individual spike events into discrete tokens, the core paradigm of POYO, is prone to overfitting on small datasets; in contrast, the bin-based tokenization approach adopted by SPINT(in Q4) achieves relatively better performance in this low-data regime. The original POYO model was trained on nearly 29,453 units to construct a stable global attention map over discrete spike tokens. Furthermore, there exists a substantial discrepancy between our target brain region and the motor cortex that POYO was designed for. As explicitly stated in the POYO work, all data in its multi-laboratory dataset were collected from the motor cortex. This mismatch in brain regions is likely a key reason for its limited applicability to our olfactory decoding task.\n\nWe will supplement the above baseline comparisons in the revised manuscript and specify the data input format adopted by POYO.\n\n---\n\n###"+ },+ "createdAt": "2026-07-30T13:24:04.846Z",+ "modifiedAt": "2026-11-19T17:15:55.012Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=ok5EdPcqhC",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/orokyz0rp5.json added
+++ b/reviews/openreview/7mdyfydgom/notes/orokyz0rp5.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "orokYZ0rp5",+ "replyTo": "lUNzQwPncG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q2、W2: Conceptual Clarification on \"Zero-Shot\" Claim and AdaBN Batch Dynamics\n\nWe sincerely thank the reviewer for correcting the terminology in our work and for the constructive feedback. We have conducted supplementary experiments and detailed clarifications to fully address your concerns. Following your suggestion, given the design of AdaBN in our framework, we will revise the description from \"recalibration-free / zero-shot\" to transductive test-time adaptation (TTA) in the revised manuscript. For all models, hyperparameter tuning was uniformly performed by training on data from the first three weeks of each mouse and validating on Week 4 data.\n\nWe provide detailed responses to your specific questions below:\n\n1. During hyperparameter tuning, we applied a consistent batch size to both the training and validation sets, and the final optimal batch size was determined to be 32. Accordingly, the main experimental results reported in our original manuscript reflect the performance of AdaBN with a batch size of 32. In response to your question regarding the required target data scale for AdaBN, we carried out supplementary experiments on the test set, including a strictly frozen end-to-end variant without AdaBN, as well as AdaBN configurations with batch sizes of 4, 8, 16, and 32. We obtained several noteworthy findings, summarized in the table below:\n\n\n| AdaBN Batch Size | Accuracy (Mean $\\pm$ SD) | Precision (Mean $\\pm$ SD) | F1-Score (Mean $\\pm$ SD) |\n| :----------------------------: | :----------------------: | :-----------------------: | :----------------------: |\n| **No AdaBN** | $0.8008 \\pm 0.1817$ | $0.8193 \\pm 0.1778$ | $0.7871 \\pm 0.1987$ |\n| **$N = 4$** | $0.8786 \\pm 0.1626$ | $0.8790 \\pm 0.1661$ | $0.8744 \\pm 0.1670$ |\n| **$N = 8$** | $0.8559 \\pm 0.1654$ | $0.8582 \\pm 0.1683$ | $0.8523 \\pm 0.1693$ |\n| **$N = 16$** | $0.8411 \\pm 0.1637$ | $0.8446 \\pm 0.1667$ | $0.8369 \\pm 0.1682$ |\n| **$N = 32$ (Default)** | $0.8367 \\pm 0.1644$ | $0.8386 \\pm 0.1683$ | $0.8298 \\pm 0.1702$ |\n\n\tWe have confirmed that the data loading order of the test set matches the original trial sequence in the experiment, and the odor presentation order across trials was randomized. This rules out the possibility that performance improvements stem from balanced class representation within each batch. We attribute this pattern to sensory adaptation in olfactory bulb neurons. A batch of 32 trials spans a relatively long time window, and batch statistics computed over such a tens-of-minutes timescale may conflate neural drift driven by sensory adaptation. In contrast, the shorter 4-trial window provides a background baseline with finer temporal resolution, preventing the model from misinterpreting \"attenuated neural responses due to sensory adaptation\" as a change in odor category.\n\n2. The comparative experiments with the zero-target baseline will be presented together with the amLDS results in \"Response to Q4\".\n3. For all models, hyperparameter tuning was uniformly conducted using Weeks 1–3 data for training and Week 4 data for validation per mouse. The results across different AdaBN batch sizes also confirm that our hyperparameter tuning process did not leverage any data from Weeks 5–12.\n\nExperiments on AdaBN will be supplemented in the appendix of the revised manuscript."+ },+ "createdAt": "2026-07-30T13:24:50.788Z",+ "modifiedAt": "2026-11-19T17:15:54.788Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=orokYZ0rp5",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/p7k2ieyvdg.json added
+++ b/reviews/openreview/7mdyfydgom/notes/p7k2ieyvdg.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "P7K2ieyvDG",+ "replyTo": "lUNzQwPncG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer hxAG,\n\nThank you once again for your valuable feedback on our submission **[Manuscript ID: 31383, Title: Multi-Level Alignment Framework for Long-Term Olfactory Neural Decoding]**.\n\nAs the discussion phase is approaching its end, we would like to gently follow up on whether our response has adequately addressed your concerns. Should there be any remaining questions or areas requiring further clarification, please do not hesitate to let us know. \n\nWe greatly appreciate your time and effort in reviewing our work, and we sincerely look forward to your feedback.\n\nBest regards,\n\nThe Authors"+ },+ "createdAt": "2026-08-03T11:38:29.244Z",+ "modifiedAt": "2026-11-19T17:15:54.616Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=P7K2ieyvDG",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/qaaplwgcfy.json added
+++ b/reviews/openreview/7mdyfydgom/notes/qaaplwgcfy.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "QaaPlwgCFy",+ "replyTo": "yt2Eob759U",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q3、Q4、Q8: Lack of Theoretical Motivation and Biological Incorporation\n\n**Author Response:**\nWe sincerely appreciate this constructive feedback. The tri-level alignment strategy was explicitly designed from the outset to directly counteract the biophysically motivated challenges inherent to long-term chronic electrode implants. Each level of our alignment framework directly maps to one or more of these concrete biological challenges:\n* **Physical-Level Alignment (Addressing respiration-coupled micro-motion and signal decay):**\n The Olfactory Bulb resides in a mechanically unstable environment where ongoing respiratory rhythms induce continuous physiological motion, leading to electrode micro-motion. Furthermore, glial encapsulation and changing cellular states cause signal decay. The \"Decoupling and Dynamic Gating\" module at the physical level counteracts these issues via the dynamic gating formulation:\n\n $$K_{\\mathrm{final}} = K_{\\mathrm{id}} + G \\odot V_{\\mathrm{state}}$$\n\n The gating matrix $G \\in (0,1)^{N \\times d}$ functions as a differentiable biological confidence filter. When neuronal activity decays or drifts out of a recording channel's effective range, the resulting identity distortion forces $G \\rightarrow 0$. This effectively cuts off noisy features and compels the network to rely solely on invariant physical identities ($K_{\\mathrm{id}}$).\n\n* **Decision-Level Alignment (Addressing localized neurogenesis and neural remodeling):**\n The Olfactory Bulb is a rare site of active adult neurogenesis, where continuous granule cell turnover dynamically reshapes local circuit connectivity. Consequently, specific local neural features distort or become obsolete over weeks. The parallel Mixture-of-Experts architecture at the decision level is deployed not merely for standard model ensembling, but to achieve biological fault tolerance. When neurogenesis causes localized channel silence or structural distortion, taking the expectation over parallel expert subspaces attenuates the high variance introduced by local circuit restructuring.\n\n* **Manifold-Level Alignment (Addressing low-dimensional representational drift geometry):**\n Existing literature (*Gallego et al., Nature Neuroscience, 2020*) has established that despite continuous neural turnover over long timescales, there exist stable low-dimensional latent dynamics. Therefore, our manifold alignment is designed precisely to identify a latent space $\\mathbf{z}$ composed of stable low-dimensional manifolds. Driven by chronic baseline fluctuations, electrode impedance changes, and neural remodeling, representational drift can be decomposed into a **translation vector $\\mathbf{b}$** in the latent space (capturing baseline firing rate shifts) and a **transformation matrix $A_{i \\to j}$** (capturing gain changes and feature rotation). Consequently, we formalize the neural manifold mapping for the same odor across different time points (Session $i$ to Session $j$) as a complete affine transformation:\n\n $$z_j \\approx A_{i \\to j} z_i + b$$\n\n The vector $b$ causes a rigid shift in the mean feature distribution across weeks. We employ Adaptive Batch Normalization (AdaBN) to re-center the target manifold:\n\n $$\\hat{h}^{(l)} = \\frac{h^{(l)} - \\mu_{\\mathrm{target}}^{(l)}}{\\sqrt{\\sigma_{\\mathrm{target}}^{2(l)} + \\epsilon}} \\odot \\gamma^{(l)} + \\beta^{(l)}$$\n\n Subtracting the target domain mean $\\mu_{\\mathrm{target}}$ mathematically cancels out the rigid translation bias $b$ in expectation. However, even after eliminating $b$, the manifold remains distorted by $A_{i \\to j}$ (encompassing rotation and scaling, akin to amLDS). Assuming $z_j = A z_i$, the source and target covariance matrices satisfy $\\Sigma_j = A \\Sigma_i A^\\top$. To eliminate the distortion caused by $A$, we must minimize the discrepancy between $\\Sigma_j$ and $\\Sigma_i$, directly motivating the Deep CORAL loss:\n\n $$\\frac{1}{4d^2} \\sum_{i \\neq j} \\|\\Sigma_i - \\Sigma_j\\|_F^2$$\n\n By minimizing the Frobenius norm discrepancy between cross-session covariance matrices, the network theoretically learns an inverse transformation to neutralize the geometric deformations (rotation and scaling) induced by $A_{i \\to j}$.\n\n However, relying solely on AdaBN and CORAL introduces a theoretical vulnerability: both are global unsupervised constraints. Forcing global covariance alignment under small-sample regimes easily leads to inter-class manifold collapse or overlap. To safeguard discriminative geometric boundaries between odor categories during global alignment, an inter-class repulsive loss is theoretically required. Supervised Contrastive Learning serves this explicit purpose. This objective ensures that intra-class samples cluster together in the latent space while inter-class manifolds repel one another, explicitly preserving discriminative margins during global alignment.\n\nWe will add these formal theoretical proofs and biological mappings to a dedicated Appendix section."+ },+ "createdAt": "2026-07-30T12:32:24.429Z",+ "modifiedAt": "2026-11-19T17:15:54.969Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=QaaPlwgCFy",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/rwn3w84bae.json added
+++ b/reviews/openreview/7mdyfydgom/notes/rwn3w84bae.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "RwN3W84bae",+ "replyTo": "yt2Eob759U",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q1: Unfair Baseline Comparisons\n\n**Author Response:**\nWe appreciate the reviewer's attention to fair benchmarking. Our original decision to restrict baselines to \"manually tracked common units\" was driven by three practical constraints: (1) Without cross-week common-unit tracking and alignment, traditional models incorporate chaotic and uninformative signals, ultimately leading to severe overfitting; (2) Standard decoders lack the architectural mechanisms to process multi-modal, variable-dimension inputs natively; (3) We used manual tracking to implicitly provide baselines with the benefit of waveform and position stability.\n\nTo address your concern regarding input parity, we have conducted multiple sets of new experiments evaluating the baselines under identical full-data conditions: All baselines use the same input as LNDN: firing matrices are zero-padded to capacity, with waveform and position vectors prepended to prevent temporal model (e.g., RNN/LSTM) hidden state collapse. Since native POYO requires continuous spike tokens and cannot accommodate auxiliary physical features, it is evaluated on its native raw spike tokens for comparison.\n\n| Model Configuration | Accuracy | Precision | F1-Score |\n| :---------------------- | :------------------ | :------------------ | :------------------ |\n| **LNDN (full data)** | **0.8367 ± 0.1644** | **0.8386 ± 0.1683** | **0.8298 ± 0.1702** |\n| SVM (full data) | 0.4625 ± 0.0961 | 0.4248 ± 0.1570 | 0.3803 ± 0.1152 |\n| CEBRA (full data) | 0.4412 ± 0.1092 | 0.3994 ± 0.1365 | 0.3596 ± 0.1216 |\n| LDA (full data) | 0.4258 ± 0.0871 | 0.4180 ± 0.1060 | 0.3498 ± 0.0949 |\n| RF (full data) | 0.4248 ± 0.0740 | 0.4311 ± 0.1051 | 0.3677 ± 0.0888 |\n| XGBoost (full data) | 0.3878 ± 0.0698 | 0.3728 ± 0.1246 | 0.3218 ± 0.0916 |\n| LSTM (full data) | 0.3564 ± 0.0852 | 0.3100 ± 0.1077 | 0.2755 ± 0.0914 |\n| Transformer (full data) | 0.3431 ± 0.0663 | 0.2471 ± 0.0736 | 0.2387 ± 0.0654 |\n| RNN (full data) | 0.3200 ± 0.0677 | 0.2615 ± 0.0886 | 0.2339 ± 0.0675 |\n| POYO(Scratch) | 0.5089 ± 0.1041 | 0.5296 ± 0.1355 | 0.4820 ± 0.1183 |\n| POYO(Pretrained) | 0.5046 ± 0.1082 | 0.5138 ± 0.1297 | 0.4702 ± 0.1258 |\n\nThe results demonstrate that standard baselines suffer severe performance degradation (falling below 50%) when exposed to the raw, un-tracked cross-week data due to severe noise overfitting. For this reason, we utilize cross-week aligned neurons specifically to ensure baseline models can be fairly compared against our method at their best achievable performance. We will include this exhaustive parity benchmark in the revised manuscript."+ },+ "createdAt": "2026-07-30T12:10:34.406Z",+ "modifiedAt": "2026-11-19T17:15:54.973Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=RwN3W84bae",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/tu9fmwm9wz.json added
+++ b/reviews/openreview/7mdyfydgom/notes/tu9fmwm9wz.json@@ -0,0 +1,16 @@+{+ "schema": "review/1",+ "id": "Tu9fmwm9Wz",+ "replyTo": "uQTJDhIviy",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Reviewer 3gev",+ "content": {+ "title": "Official Comment by Reviewer",+ "comment": "Thank you for addressing the questions raised in the previous review. However, the authors’ responses only partially address my concerns, and several important issues remain unresolved.\n\n(1) Although the authors have conducted additional experiments, the selected baselines are relatively outdated and may not be sufficient to demonstrate the superiority and effectiveness of the proposed method. More comparisons with recent state-of-the-art approaches are needed to validate the advantages of the proposed framework.\n\n(2) The manuscript still contains a large number of unexplained acronyms (e.g., SSHD, LNDN, MoE, AdaBN, CORAL), which significantly affects readability and makes the proposed method difficult to follow. The revised manuscript requires substantial improvement in terms of presentation and clarity.\n\n(3) The proposed framework consists of multiple components, resulting in considerable computational complexity. The authors should provide a more detailed analysis of computational costs, including inference time and resource consumption, to demonstrate whether the proposed method is suitable for real-time applications.\n\n(4) Compared with existing baseline methods, the proposed framework introduces additional complexity, which may limit its deployment on resource-constrained devices. The authors should discuss the practical feasibility of deployment and provide relevant experimental results or model efficiency analysis."+ },+ "createdAt": "2026-08-04T07:05:17.198Z",+ "modifiedAt": "2026-11-19T17:15:54.492Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=Tu9fmwm9Wz",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/uqtjdhiviy.json added
+++ b/reviews/openreview/7mdyfydgom/notes/uqtjdhiviy.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "uQTJDhIviy",+ "replyTo": "yt2Eob759U",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "Dear Reviewer 3gev,\n\nThank you once again for your valuable feedback on our submission **[Manuscript ID: 31383, Title: Multi-Level Alignment Framework for Long-Term Olfactory Neural Decoding]**.\n\nAs the discussion phase is approaching its end, we would like to gently follow up on whether our response has adequately addressed your concerns. Should there be any remaining questions or areas requiring further clarification, please do not hesitate to let us know. \n\nWe greatly appreciate your time and effort in reviewing our work, and we sincerely look forward to your feedback.\n\nBest regards,\n\nThe Authors"+ },+ "createdAt": "2026-08-03T11:37:49.308Z",+ "modifiedAt": "2026-11-19T17:15:54.625Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=uQTJDhIviy",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/wnw1jfwx3h.json added
+++ b/reviews/openreview/7mdyfydgom/notes/wnw1jfwx3h.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "wNw1JfwX3h",+ "replyTo": "HRhJKF6lVM",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q1: Hardware Efficiency and Real-time Deployment\n\nWe sincerely thank the reviewer for highlighting the critical requirement of hardware efficiency in practical Brain-Computer Interface (BCI) deployment. We completely understand the concerns regarding execution on resource-constrained edge platforms and would like to provide the following clarifications regarding our real-time deployment strategy:\n\n1. **Manifold Layer (Deep CORAL):** The high-dimensional covariance computations in the manifold layer are *exclusively* utilized during the training phase to compute the alignment loss ($\\mathcal{L}_{coral}$, Section 3.3). They are entirely bypassed during real-time inference, thus incurring zero overhead during edge deployment.\n2. **Physical Layer (Spike Sorting):** On power-constrained edge devices, we can perform offline updates for $W$ and $P$ only when severe signal drift is detected. During the inference phase, only low-power online template matching is required to extract the firing activity ($X$). In fact, all trials within a recording week in our dataset share the exact same static $W$ and $P$ matrices, which further demonstrates the feasibility of deploying our physical layer design on low-power devices.\n3. **Decision Layer (MoE):** To mitigate the computational resource consumption introduced by the MoE architecture, the individual expert classifiers were intentionally designed to be highly lightweight. Rather than employing standard self-attention, each expert utilizes only a single-layer Cross-Attention mechanism with a static 1D learnable query vector (Figure 2). This structural simplification effectively reduces the computational complexity from $\\mathcal{O}(N^2 \\cdot d)$ (as seen in standard Transformers) to $\\mathcal{O}(N \\cdot d)$.\n\nTo quantitatively address the power consumption concerns, we evaluated the inference Floating Point Operations (FLOPs) and CPU latency per trial for LNDN under varying tracked neuron counts ($N$). In our dataset, valid neuron counts strictly ranged between 46 and 68 per session.\n\n| Tracked Neurons ($N$) | Total Parameters | Inference FLOPs | CPU Latency (ms/trial) |\n| :-------------------- | :--------------- | :-------------- | :--------------------- |\n| 50 | 278,892 | 15.47 M | 2.16 ms |\n| 100 | 278,892 | 30.69 M | 2.17 ms |\n| 200 | 278,892 | 61.13 M | 2.63 ms |\n\nThese results confirm that LNDN maintains a modest computational footprint suitable for real-time edge processing.We will include these efficiency metrics in the revised Appendix."+ },+ "createdAt": "2026-07-30T12:35:58.743Z",+ "modifiedAt": "2026-11-19T17:15:54.901Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=wNw1JfwX3h",+ "license": "CC-BY-4.0"+}
reviews/openreview/7mdyfydgom/notes/xud1vfvpiy.json added
+++ b/reviews/openreview/7mdyfydgom/notes/xud1vfvpiy.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "xUd1vFvPIY",+ "replyTo": "lUNzQwPncG",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "### Response to Q1、W1: Statistical Significance Testing\n\nWe sincerely thank the reviewer for raising the crucial point regarding statistical rigor and the distribution of performance gains across individual subjects and recording weeks. To address this concern, we evaluated model performance using both a Linear Mixed-Effects Model and a non-parametric paired Wilcoxon signed-rank test, accompanied by Holm-Bonferroni correction for multiple comparisons and 10,000 bootstrap iterations 95% confidence intervals for Cohen's $d$ effect sizes.\n\n1. **Statistical Model Specifications:**\n * **Linear Mixed-Effects Model (LMM):**\n $$\\text{Accuracy} = \\beta_0 + \\beta_{\\text{Model}} + \\beta_{\\text{Week}} \\cdot \\text{Weeks Elapsed} + (1 \\mid \\text{Subject})$$\n\n * **Paired Wilcoxon Signed-Rank Test:** Applied directly to paired prediction differences across all mouse-week-seed evaluation instances.\n * **Multiple Comparisons Control:** Family-Wise Error Rate controlled via Holm-Bonferroni adjusted $p$-values.\n * **Effect Size:** Cohen's $d$ calculated on paired differences, with 95% CIs estimated via non-parametric percentile bootstrapping (10,000 iterations with replacement).\n\n| Baseline Model | LMM Significance ($p$-value) | Wilcoxon Raw $P$-value | Holm Adjusted $P$-value | Cohen's $d$ Effect Size [Bootstrap 95% CI] |\n| :--------------------- | :----------------------------: | :----------------------------: | :----------------------------: | :----------------------------------------: |\n| **CEBRA** | $3.9 \\times 10^{-2}$ (\\*) | $7.2 \\times 10^{-4}$ (\\*\\*\\*) | $1.4 \\times 10^{-3}$ (\\*\\*) | 0.2381 [0.0048, 0.5646] |\n| **SVM** | $7.8 \\times 10^{-3}$ (\\*\\*) | $1.6 \\times 10^{-3}$ (\\*\\*) | $1.6 \\times 10^{-3}$ (\\*\\*) | 0.4192 [0.1879, 0.6695] |\n| **Random Forest** | $1.1 \\times 10^{-5}$ (\\*\\*\\*) | $1.2 \\times 10^{-8}$ (\\*\\*\\*) | $4.9 \\times 10^{-8}$ (\\*\\*\\*) | 0.7860 [0.6130, 1.0041] |\n| **LDA** | $3.2 \\times 10^{-6}$ (\\*\\*\\*) | $9.3 \\times 10^{-8}$ (\\*\\*\\*) | $2.8 \\times 10^{-7}$ (\\*\\*\\*) | 0.7227 [0.5106, 0.9872] |\n| **XGBoost** | $1.4 \\times 10^{-12}$ (\\*\\*\\*) | $1.5 \\times 10^{-12}$ (\\*\\*\\*) | $8.9 \\times 10^{-12}$ (\\*\\*\\*) | 1.2581 [1.0449, 1.5587] |\n| **LSTM** | $3.9 \\times 10^{-16}$ (\\*\\*\\*) | $4.1 \\times 10^{-13}$ (\\*\\*\\*) | $2.8 \\times 10^{-12}$ (\\*\\*\\*) | 1.2709 [1.0934, 1.5067] |\n| **Transformer** | $9.1 \\times 10^{-30}$ (\\*\\*\\*) | $1.6 \\times 10^{-12}$ (\\*\\*\\*) | $8.9 \\times 10^{-12}$ (\\*\\*\\*) | 1.3822 [1.1494, 1.6975] |\n| **RNN** | $4.2 \\times 10^{-38}$ (\\*\\*\\*) | $1.7 \\times 10^{-13}$ (\\*\\*\\*) | $1.7 \\times 10^{-12}$ (\\*\\*\\*) | 2.1261 [1.8276, 2.5680] |\n| **POYO (Pretrained)** | $1.5 \\times 10^{-62}$ (\\*\\*\\*) | $2.1 \\times 10^{-13}$ (\\*\\*\\*) | $1.7 \\times 10^{-12}$ (\\*\\*\\*) | 2.1932 [1.8017, 2.7875] |\n| **POYO (Scratch)** | $2.4 \\times 10^{-64}$ (\\*\\*\\*) | $1.8 \\times 10^{-13}$ (\\*\\*\\*) | $1.7 \\times 10^{-12}$ (\\*\\*\\*) | 2.2508 [1.8681, 2.8199] |\n\nTo directly address whether LNDN’s gains are concentrated in a small subset of subjects, we constructed a granular breakdown across **9 mice $\\times$ 8 weeks** (averaged across 3 random seeds):\n\n| Mouse ID (Subject) | Mean Accuracy Gain (LNDN vs. CEBRA) | LNDN Winning Weeks Ratio |\n| :----------------: | :---------------------------------: | :----------------------: |\n| **OB #1** | +3.65% | 5 / 8 |\n| **OB #2** | -14.79% | 3 / 8 |\n| **OB #3** | +6.74% | 5 / 8 |\n| **OB #4** | +10.42% | 7 / 8 |\n| **OB #5** | +5.21% | 7 / 8 |\n| **OB #6** | +10.83% | 7 / 8 |\n| **OB #7** | -4.06% | 5 / 8 |\n| **OB #8** | +10.00% | 7 / 8 |\n| **OB #9** | +15.73% | 8 / 8 |\n\nThese results confirm that LNDN outperforms CEBRA in **7 out of 9 mice**, demonstrating strong temporal persistence across individual recording weeks (typically 5/8 to 8/8 winning weeks per animal). Statistical significance of all ablation comparisons was verified via linear mixed-effects model tests, with all corresponding p-values < 0.05. We will incorporate these statistical significance markers, effect sizes, and per-mouse breakdown tables into Section 5 and Appendix of the revised manuscript."+ },+ "createdAt": "2026-07-30T13:27:21.785Z",+ "modifiedAt": "2026-11-19T17:15:54.742Z",+ "url": "https://openreview.net/forum?id=7mDyFYDgoM¬eId=xUd1vFvPIY",+ "license": "CC-BY-4.0"+}