GLINT: Sparsely Gated Vision-Language Alignment for Fine-Grained Radiology Representations
Update NeurIPS 2026 submission GLHgQkefOp: 2 notes
@openreview[bot] · 2026-11-24 15:48 UTC · d8f96f4fc583 ·
reviews/openreview/glhgqkefop/notes/cxgjlqdkbl.json modified
+++ b/reviews/openreview/glhgqkefop/notes/cxgjlqdkbl.json@@ -5,11 +5,12 @@"kind": "meta_review","invitation": "Meta_Review","signature": "Area Chair YgCq","content": {- "metareview": "This paper introduces a sigmoid-gated alignment module and a teacher-anchored feature regularizer for fine-grained radiology vision-language learning, and reports broad gains on chest X-ray and chest CT. It received one accept, one borderline accept, and one reject.\n\nI have read the authors' response, and it resolved the two validity questions and the clarity questions from my initial meta-review. On data splits, the authors audited every dataset for patient-level disjointness, found that one dataset had been split at the volume level, corrected it to a patient-level split, re-evaluated all methods, and the conclusions held. The chest CT dataset was already patient-level, with the official validation split used as the test set. On the initialization concern, they showed the gains survive when the larger teacher is removed. Even an ImageNet-pretrained variant that uses only a frozen copy of itself as the teacher, with no larger model involved, still exceeds the best prior results on every task group. So the advantage is not merely inherited from a strong backbone. They also defined the notation, separated the standard from the multi-positive contrastive branch, and reworded the sparsity claim to reflect that the sparsity is observed rather than imposed. The borderline-accept reviewer confirmed the response addressed their concerns.\n\nI recommend acceptance. Two reviewers are positive, the results are broad and internally consistent, the leakage and fairness questions were answered on existing data, and the first zero-shot free-text segmentation on 3D CT is a real capability. The remaining reject did not respond during the discussion period, and its points about clarity, notation, and a possibly machine-drawn figure are the ones the response directly addressed, so I do not find them decisive against the two positive assessments.\n\nThe authors should redraw the architecture figure with a full legend, define all notation at first use, move the variance and significance numbers into the main tables, and add the missing early fine-grained-alignment baseline to the zero-shot table."+ "metareview": "This paper introduces a sigmoid-gated alignment module and a teacher-anchored feature regularizer for fine-grained radiology vision-language learning, and reports broad gains on chest X-ray and chest CT. It received one accept, one borderline accept, and one reject.\n\nI have read the authors' response, and it resolved the two validity questions and the clarity questions from my initial meta-review. On data splits, the authors audited every dataset for patient-level disjointness, found that one dataset had been split at the volume level, corrected it to a patient-level split, re-evaluated all methods, and the conclusions held. The chest CT dataset was already patient-level, with the official validation split used as the test set. On the initialization concern, they showed the gains survive when the larger teacher is removed. Even an ImageNet-pretrained variant that uses only a frozen copy of itself as the teacher, with no larger model involved, still exceeds the best prior results on every task group. So the advantage is not merely inherited from a strong backbone. They also defined the notation, separated the standard from the multi-positive contrastive branch, and reworded the sparsity claim to reflect that the sparsity is observed rather than imposed. The borderline-accept reviewer confirmed the response addressed their concerns.\n\nI recommend acceptance. Two reviewers are positive, the results are broad and internally consistent, the leakage and fairness questions were answered on existing data, and the first zero-shot free-text segmentation on 3D CT is a real capability. The remaining reject did not respond during the discussion period, and its points about clarity, notation, and a possibly machine-drawn figure are the ones the response directly addressed, so I do not find them decisive against the two positive assessments.\n\nThe authors should redraw the architecture figure with a full legend, define all notation at first use, move the variance and significance numbers into the main tables, and add the missing early fine-grained-alignment baseline to the zero-shot table.",+ "final_justification": "Accept. The rebuttal resolved both validity questions (a patient-level split audit that corrected one dataset with unchanged conclusions, and an initialization isolation showing the gains survive without the larger teacher) and the notation and sparsity clarity items. Two reviewers are positive; the confident reject did not engage during discussion and its points were the ones the response addressed. The score-discrepancy flag on the accepting reviewer is resolved, since the review text justifies the score."},"createdAt": "2026-07-23T15:08:05.489Z",- "modifiedAt": "2026-11-18T15:25:35.482Z",+ "modifiedAt": "2026-11-19T05:03:32.766Z","url": "https://openreview.net/forum?id=GLHgQkefOp¬eId=CxGjLQdKbL","license": "CC-BY-4.0"}
reviews/openreview/glhgqkefop/notes/rr8jwho0ow.json added
+++ b/reviews/openreview/glhgqkefop/notes/rr8jwho0ow.json@@ -0,0 +1,15 @@+{+ "schema": "review/1",+ "id": "rr8jWho0Ow",+ "replyTo": "CxGjLQdKbL",+ "kind": "comment",+ "invitation": "Official_Comment",+ "signature": "Authors",+ "content": {+ "comment": "We thank the AC for prioritizing these three points. All three points have been addressed in detail in the corresponding reviewer threads. We briefly summarize them here.\n\n**Q1.** We re-checked patient-level disjointness across all datasets. CT-RATE, which the reviewer raised, is unaffected: our splits are patient-level, and our test set is the official validation split. In LIDC-IDRI the split had been constructed at the volume level. This affected only 7 of the 1,010 volumes. We moved them into the test set (709 / 151 / 150 → 705 / 148 / 157), re-evaluated all methods on the corrected split, and the conclusions are unchanged. All dataset splits have now been re-verified.\n\n**Q2.** We report three settings. (i) Even without the larger teacher, our model outperforms the best prior work. (ii) Under matched initialization, it improves over both CARZero and RadZero — backbone and resolution matched exactly for CARZero, and for RadZero the comparison is conservative since RadZero benefits from a radiology-adapted XrayDINOv2 initialization, whereas ours uses the generic DINOv2 checkpoint. (iii) Even an ImageNet-21k SSL initialization with a frozen copy of itself as the teacher, with no medical pretraining and no larger teacher, surpasses the best prior result.\n\n**Q3.** We have clarified where the notation and the loss formulation could cause confusion, and will state both in the paper. On \"explicit sparsity\": the sparsity is by design but is not enforced by a penalty, so we will revise the wording. Figure 3 shows that the sparsity emerges empirically from the design. \n\nWe thank the AC and all reviewers for their careful consideration. We hope the detailed responses provided in each thread will be taken into account during the final assessment."+ },+ "createdAt": "2026-08-04T08:40:07.303Z",+ "modifiedAt": "2026-11-19T17:10:08.161Z",+ "url": "https://openreview.net/forum?id=GLHgQkefOp¬eId=rr8jWho0Ow",+ "license": "CC-BY-4.0"+}